Imron Corporation SI-16 User manual

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
Installation and Specification
1. General:
The SI-16 sub-controller provides sensor interface and output controls for system integrators in
security/access control and other application. The controller has 16 input channels for supervised contact
monitoring and 2 form-C contacts for load switching. In addition, 2 digital inputs may be used for tamper
and UPS status monitoring. The sub-controller requires either 12Vdc or 12Vac for power.

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
2. Supply Power to the Interface:
The sub-controller accepts either 12Vdc or 12Vac for power. Locate power source as closed to the unit
as possible. Connect power with minimum of 18AWG wires.
Observe POLARITY for 12Vdc application!
3. Communication Wiring:
The SI-16 communicates to host via a RS-485 interface, which may be configured for either 2-wire or 4-
wire operation. The interface allows multi-drop communication on a single bus of up to 4,000 feet (1,200
m). Use twisted pair(s) (minimum 24 AWG) with shield for the communication.
Install the following jumpers for the RS-485 interface according to the selected configuration:

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
4. Alarm Inputs Wiring:
Inputs 1 to 16 may be configured to use or not to use End of Line (EOL) resistors and to use normally
open or normally closed contacts. Input CT and input BA are typically used for monitoring cabinet tamper
and power failure respectively. These two inputs are for contact closure monitoring only, and do not use
EOL resistor(s).
5. Relay Outputs:
The following show typical use of the relay outputs. DC source is recommended whenever it is possible.
Transient clamping must be provided to protect the contact and to reduce EMI emission. Use sufficiently
large wires for the load current to avoid voltage loss.

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
6. DIP Switch Usage:
Switches 1 to 5 select the devices communication address. Switches 6 to 7 select the communication
baud rate. Communication on the RS-485 serial port is asynchronous, half-duplex with 1 start bit, 8 data
bits and 1 stop bit.
S8 S7 S6 S5 S4 S3 S2 S1
SELECTION
OFF OFF OFF OFF OFF ADDRESS 0
OFF OFF OFF OFF ON ADDRESS 1
OFF OFF OFF ON OFF ADDRESS 2
OFF OFF OFF ON ON ADDRESS 3
OFF OFF ON OFF OFF ADDRESS 4
OFF OFF ON OFF ON ADDRESS 5
OFF OFF ON ON OFF ADDRESS 6
OFF OFF ON ON ON ADDRESS 7
OFF ON OFF OFF OFF ADDRESS 8
OFF ON OFF OFF ON ADDRESS 9
OFF ON OFF ON OFF ADDRESS 10
OFF ON OFF ON ON ADDRESS 11
OFF ON ON OFF OFF ADDRESS 12
OFF ON ON OFF ON ADDRESS 13
OFF ON ON ON OFF ADDRESS 14
OFF ON ON ON ON ADDRESS 15
ON OFF OFF OFF OFF ADDRESS 16
ON OFF OFF OFF ON ADDRESS 17
ON OFF OFF ON OFF ADDRESS 18
ON OFF OFF ON ON ADDRESS 19
ON OFF ON OFF OFF ADDRESS 20
ON OFF ON OFF ON ADDRESS 21
ON OFF ON ON OFF ADDRESS 22
ON OFF ON ON ON ADDRESS 23
ON ON OFF OFF OFF ADDRESS 24
ON ON OFF OFF ON ADDRESS 25
ON ON OFF ON OFF ADDRESS 26
ON ON OFF ON ON ADDRESS 27
ON ON ON OFF OFF ADDRESS 28
ON ON ON OFF ON ADDRESS 29
ON ON ON ON OFF ADDRESS 30
ON ON ON ON ON ADDRESS 31
OFF OFF 2,400 BPS
OFF ON 9,600 BPS
ON OFF 19,200 BPS
ON ON 38,400 BPS
OFF NOT USED

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
7. Specification:
The sub-controller is for use in low voltage, class 2 circuit only.
Primary power: (DC or AC)
DC input: 12Vdc±10%, 350mA
AC input: 12Vac±15%, 500mA RMS
Relay Contacts: 2 form C, 5A 28Vdc, Resistive.
Inputs: 16 supervised, EOL 1,000 OHM/1,000 OHM standard
2 non-supervised
Wire requirement:
Power: 1 twisted pair, 18 AWG
RS-485: 24AWG, 4,000ft (1,200m) max., twisted pair(s) with shield.
Alarm input: 1 twisted pair, 30 ohms max.
Output: As required for the load
Environmental:
Temperature: 0 to 70 °C, operating
-55 to +85 °C, storage
Humidity: 0 to 95% RHNC
Mechanical:
Dimension: 6 in. (152mm) W x 8 in. (203mm) L x 1 in. (25mm) H
Weight: 10 oz (290 gm) nominal
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation.

Imron Corporation
15375 Barranca Pkwy, Suite B-106
Irvine, CA 92618
Phone 949-341-0947
Fax 949-341-0949
INTEGRATED SYSTEM 2000 SI-16 INPUT PROCESSOR
System Control Processor
Warranty
Imron Corporation warrants the product is free from defects in material and workmanship under normal
use and service with proper maintenance for one year from the date of factory shipment. Imron
Corporation assumes no responsibility for products damaged by improper handling or installation. This
warranty is limited to the repair or replacement of the defective unit.
There are no expressed warranties other than set forth herein. Imron Corporation does not make, nor
intends, nor does it authorize any agent or representative to make any other warranties, or implied
warranties, and expressly excludes and disclaims all implied warranties of merchantability or fitness for a
particular purpose.
Returned units are repaired or replaced from a stock of reconditioned units. Returns must be
accompanied by a return authorization number (RMA) obtained from customer service, and prepaid
postage and insurance.
Liability
The Interface should only be used to control exits from areas where an alternative method for exit is
available. This product is not intended for, nor is rated for operation in life-critical control applications.
Imron Corporation is not liable under any circumstances for loss or damage caused by or partially caused
by the misapplication or malfunction of the product. Imron Corporation's liability does not extend beyond
the purchase price of the product.
Table of contents
Other Imron Corporation Controllers manuals
Popular Controllers manuals by other brands

Dyna-Flo
Dyna-Flo DFC Parts and instruction manual

iLight
iLight SCMH1200 installation guide

EquipSolutions
EquipSolutions Tempest 2.0 Operation & programming manual

ACUVANCE
ACUVANCE Rapida Series instruction manual

Texas Instruments
Texas Instruments DLP LightCrafter Dual DLPC900 Read this first

Mitsubishi Electric
Mitsubishi Electric MELSEC iQ-R Series Programming manual