Nozzle Leak Detector Operators Instructions
A. Without machine interface
1. Attach Bracket Assembly to Nozzle with hose clamp (sold
separately).
2. Affix the thermocouple into bracket and tighten in place with
set screw .
3. With unit toggled to OFF position, plug thermocouple into the
thermocouple socket located on the right side of the unit.
4. Plug the leak detector unit into a standard 120V grounded
receptacle.
5. Toggle switch to ON position to power up the unit.
6. Adjust the set point on the controller to approximately 100 to
150°F below the nozzle zone temperature.
• To adjust the set point temperature on the controller, refer
to the Model 3300 Controller instruction manual.
• Instructions to lock the set point temperature are included
in the Model 3300 Controller Instruction manual.
7. When a leak is detected, the audible alarm will sound and the
LED will light up. Turn unit OFF and repair leak.
• NOTE: Do not just toggle switch to OFF position without
repairing leak.
• To reset controller, follow instructions on the Model 3300
Controller Instruction manual
• Audible alarm volume can be adjusted by rotating the
louver on alarm face.
8. After the leak is fixed and the controller is reset turn unit back
ON. The audible alarm will remain silent and the LED warning
light will remain off until another leak is detected.
B. With Machine Interface
1. Attach Bracket Assembly to Nozzle with hose clamp (sold
separately).
2. Affix the thermocouple into bracket and tighten in place with
set screw.
3. With unit toggled to OFF position, plug thermocouple into the
thermocouple socket located on the right side of the unit.
4. Wire plugs (included with unit) to use for input and output.
• Hot wire goes to brass screw
• Neutral wire goes to silver screw
NOTE: there is no ground for input and output
CAUTION: ONLY WIRE PLUGS WHEN THERE IS NO
VOLTAGE PRESENT
5. Insert plugs from machine into appropriate receptacles
located on side of unit.
• Input receptacle is for input voltage at standard 120v non
grounded power.
• Output receptacle is for output voltage at standard 120v
non grounded power.
Note: Input receptacle will always have power and Output
receptacle will have no power until a leak is detected.
6. Plug the leak detector unit into a standard 120V grounded
receptacle.
7. Toggle the switch to ON position to power up the unit.
8. Adjust the set point on the controller to approximately 100 to
150°F below the nozzle zone temperature.
• To adjust the set point temperature on the controller, refer
to the Model 3300 Controller instruction manual.
• Instructions to lock the set point temperature are included
in the Model 3300 Controller Instruction manual.
9. When a leak is detected, the audible alarm will sound and the
LED will light up. Turn unit OFF and repair leak.
• NOTE: Do not just toggle switch to OFF position without
repairing leak.
• To reset controller, follow instructions on the Model 3300
Controller Instruction manual.
• Audible alarm volume can be adjusted by rotating the
louver on alarm face.
10. After the leak is fixed and the controller is reset, toggle
switch back to ON position. The audible alarm will remain
silent and the LED warning light will remain off until another
leak is detected.
Nozzle Leak Detector Specifications
Unit ON with NO Leaks
Sonalert Alarm OFF/LED OFF/Output
Receptacle has NO power
Voltage: 120V
Amperage: (PEAK) 0.022 amps
(AVERAGE) 0.016 amps
Power/Wattage: (PEAK) 1.4 W
(AVERAGE) 1 W
Unit ON DETECTING Leaks
Sonalert Alarm ON/LED ON/Output
Receptacle HAS power
Voltage: 120V
Amperage: (PEAK) 0.034 amps
(AVERAGE) 0.032 amps
Power/Wattage: (PEAK) 3.5 W
(AVERAGE) 3.4 W

Nozzle Leak Detector Controller
Controller Model 3300
#171707
January 2020
Industrial Molding Supplies
10373 Stafford Road
Chagrin Falls, OH 44023-5296
Telephone: (440) 543-1615
Fax: (440) 543-1069
Email: sales@imscompany.com
Website: www.imscompany.com
© Copyright 2019 IMS Company. All rights reserved.

Model 3300 Controller Programming
Instructions
To Program the Set Point Temperature:
1. Press and hold the “*” button.
• “°F” and the temperature flash back and forth in the display
2. While holding the “*” button, press button to move set
point temperature up, or press button to move set point
temperature down
• Holding the or button while holding the “*” button
will change the temperature continuously
• Quickly pressing the or button while holding the “*”
button will change the temperature in 1-degree increments
with each press
3. After you reach the desired set point temperature, release the
“*” button; your set point temperature is now programmed.
Note: The current thermocouple temperature is displayed.
To Lock the Set Point Temperature:
After you set the temperature, you can lock it by following
the instructions below:
1. Press and hold both or buttons together until “tune” is
displayed, then release both buttons.
• The word “tune” and the word “off” flash back and forth in
the display
2. Press the button until you see “SP.Lk” in the display.
• “SP.Lk” and the word “off” should be flashing back and
forth in the display
3. When “SP.L” is displayed, press and hold the “*” button and
the or button to select off or on.
4. Select “on” and release the “*” button; the set point is now
locked.
5. Press and hold the or buttons together until the
thermocouple temperature is displayed, then release the
buttons.
6. To verify that the set point is locked, press and hold the “*”
button, and while holding the “*” button, quickly press either
the or button.
• If the set point is locked, the temperature will not move
• If the temperature changes, repeat steps 1-5
To Reset Controller:
1. After the unit detects a leak, the audible alarm and LED will
activate and remain on until the controller is reset.
Caution: Only reset controller after the leak is fixed.
2. Before the temperature can be reset, the temperature of the
thermocouple displayed on the controller must be below the
set point temperature; the controller cannot be reset until this
happens.
3. To reset the controller, press the and buttons together
and release quickly. The controller will reset and both audible
alert and LED will turn off.
Other IMS Security Sensor manuals
Popular Security Sensor manuals by other brands

Niko
Niko SERVODAN user manual

Agilent Technologies
Agilent Technologies 5977C Series operating manual

Intelbras
Intelbras IVP 4101 PET user manual

LST
LST OH-13001 Specification sheet

Notch
Notch Sentinel Arborist Harness manual

ITALIANA SENSORI
ITALIANA SENSORI 8057-ISR043 Installation, operation and maintenance manual