Nozzle Leak Detector Operators Instructions
#171707
January 2020
Industrial Molding Supplies
10373 Stafford Road
Chagrin Falls, OH 44023-5296
Telephone: (440) 543-1615
Fax: (440) 543-1069
Email: sales@imscompany.com
Website: www.imscompany.com
© Copyright 2019 IMS Company. All rights reserved.
Nozzle Leak Detector Operators Instructions
A. Without machine interface
1. Attach Bracket Assembly to Nozzle with hose clamp (sold
separately).
2. Affix the thermocouple into bracket and tighten in place with
set screw .
3. With unit toggled to OFF position, plug thermocouple into the
thermocouple socket located on the right side of the unit.
4. Plug the leak detector unit into a standard 120V grounded
receptacle.
5. Toggle switch to ON position to power up the unit.
6. Adjust the set point on the controller to approximately 100 to
150°F below the nozzle zone temperature.
• To adjust the set point temperature on the controller, refer
to the Model 3300 Controller instruction manual.
• Instructions to lock the set point temperature are included
in the Model 3300 Controller Instruction manual.
7. When a leak is detected, the audible alarm will sound and the
LED will light up. Turn unit OFF and repair leak.
• NOTE: Do not just toggle switch to OFF position without
repairing leak.
• To reset controller, follow instructions on the Model 3300
Controller Instruction manual
• Audible alarm volume can be adjusted by rotating the
louver on alarm face.
8. After the leak is fixed and the controller is reset turn unit back
ON. The audible alarm will remain silent and the LED warning
light will remain off until another leak is detected.
B. With Machine Interface
1. Attach Bracket Assembly to Nozzle with hose clamp (sold
separately).
2. Affix the thermocouple into bracket and tighten in place with
set screw.
3. With unit toggled to OFF position, plug thermocouple into the
thermocouple socket located on the right side of the unit.
4. Wire plugs (included with unit) to use for input and output.
• Hot wire goes to brass screw
• Neutral wire goes to silver screw
NOTE: there is no ground for input and output
CAUTION: ONLY WIRE PLUGS WHEN THERE IS NO
VOLTAGE PRESENT
5. Insert plugs from machine into appropriate receptacles
located on side of unit.
• Input receptacle is for input voltage at standard 120v non
grounded power.
• Output receptacle is for output voltage at standard 120v
non grounded power.
Note: Input receptacle will always have power and Output
receptacle will have no power until a leak is detected.
6. Plug the leak detector unit into a standard 120V grounded
receptacle.
7. Toggle the switch to ON position to power up the unit.
8. Adjust the set point on the controller to approximately 100 to
150°F below the nozzle zone temperature.
• To adjust the set point temperature on the controller, refer
to the Model 3300 Controller instruction manual.
• Instructions to lock the set point temperature are included
in the Model 3300 Controller Instruction manual.
9. When a leak is detected, the audible alarm will sound and the
LED will light up. Turn unit OFF and repair leak.
• NOTE: Do not just toggle switch to OFF position without
repairing leak.
• To reset controller, follow instructions on the Model 3300
Controller Instruction manual.
• Audible alarm volume can be adjusted by rotating the
louver on alarm face.
10. After the leak is fixed and the controller is reset, toggle
switch back to ON position. The audible alarm will remain
silent and the LED warning light will remain off until another
leak is detected.
Nozzle Leak Detector Specifications
Unit ON with NO Leaks
Sonalert Alarm OFF/LED OFF/Output
Receptacle has NO power
Voltage: 120V
Amperage: (PEAK) 0.022 amps
(AVERAGE) 0.016 amps
Power/Wattage: (PEAK) 1.4 W
(AVERAGE) 1 W
Unit ON DETECTING Leaks
Sonalert Alarm ON/LED ON/Output
Receptacle HAS power
Voltage: 120V
Amperage: (PEAK) 0.034 amps
(AVERAGE) 0.032 amps
Power/Wattage: (PEAK) 3.5 W
(AVERAGE) 3.4 W
Nozzle Leak Detector Controller
Controller Model 3300
#171707
January 2020
Industrial Molding Supplies
10373 Stafford Road
Chagrin Falls, OH 44023-5296
Telephone: (440) 543-1615
Fax: (440) 543-1069
Email: sales@imscompany.com
Website: www.imscompany.com
© Copyright 2019 IMS Company. All rights reserved.
Model 3300 Controller Programming
Instructions
To Program the Set Point Temperature:
1. Press and hold the “*” button.
• “°F” and the temperature flash back and forth in the display
2. While holding the “*” button, press button to move set
point temperature up, or press button to move set point
temperature down
• Holding the or button while holding the “*” button
will change the temperature continuously
• Quickly pressing the or button while holding the “*”
button will change the temperature in 1-degree increments
with each press
3. After you reach the desired set point temperature, release the
“*” button; your set point temperature is now programmed.
Note: The current thermocouple temperature is displayed.
To Lock the Set Point Temperature:
After you set the temperature, you can lock it by following
the instructions below:
1. Press and hold both or buttons together until “tune” is
displayed, then release both buttons.
• The word “tune” and the word “off” flash back and forth in
the display
2. Press the button until you see “SP.Lk” in the display.
• “SP.Lk” and the word “off” should be flashing back and
forth in the display
3. When “SP.L” is displayed, press and hold the “*” button and
the or button to select off or on.
4. Select “on” and release the “*” button; the set point is now
locked.
5. Press and hold the or buttons together until the
thermocouple temperature is displayed, then release the
buttons.
6. To verify that the set point is locked, press and hold the “*”
button, and while holding the “*” button, quickly press either
the or button.
• If the set point is locked, the temperature will not move
• If the temperature changes, repeat steps 1-5
To Reset Controller:
1. After the unit detects a leak, the audible alarm and LED will
activate and remain on until the controller is reset.
Caution: Only reset controller after the leak is fixed.
2. Before the temperature can be reset, the temperature of the
thermocouple displayed on the controller must be below the
set point temperature; the controller cannot be reset until this
happens.
3. To reset the controller, press the and buttons together
and release quickly. The controller will reset and both audible
alert and LED will turn off.

Other IMS Security Sensor manuals

IMS E3TA Series User manual

IMS

IMS E3TA Series User manual

IMS CX3068 User manual

IMS

IMS CX3068 User manual

Popular Security Sensor manuals by other brands

Geca Beta 760 CO manual

Geca

Geca Beta 760 CO manual

GEV TITAN FLAT180 LBB 16859 user manual

GEV

GEV TITAN FLAT180 LBB 16859 user manual

Lamtec F152 manual

Lamtec

Lamtec F152 manual

koban KDP-DALI 01 manual

koban

koban KDP-DALI 01 manual

Dräger Pac 7000 Instructions for use

Dräger

Dräger Pac 7000 Instructions for use

Climax EIR-32 manual

Climax

Climax EIR-32 manual

Roland Double Sheet Detector I100 manual

Roland

Roland Double Sheet Detector I100 manual

Doka Staxo 40 Instructions for assembly and use

Doka

Doka Staxo 40 Instructions for assembly and use

Stanley IntelliLaser Pro user manual

Stanley

Stanley IntelliLaser Pro user manual

quiko QK-FTP40 Operating and installation instructions

quiko

quiko QK-FTP40 Operating and installation instructions

Optex Smart Line SL-350 QNR installation instructions

Optex

Optex Smart Line SL-350 QNR installation instructions

Orbis EBR-2 Instructions for use

Orbis

Orbis EBR-2 Instructions for use

Niko SERVODAN user manual

Niko

Niko SERVODAN user manual

Agilent Technologies 5977C Series operating manual

Agilent Technologies

Agilent Technologies 5977C Series operating manual

Intelbras IVP 4101 PET user manual

Intelbras

Intelbras IVP 4101 PET user manual

LST OH-13001 Specification sheet

LST

LST OH-13001 Specification sheet

Notch Sentinel Arborist Harness manual

Notch

Notch Sentinel Arborist Harness manual

ITALIANA SENSORI 8057-ISR043 Installation, operation and maintenance manual

ITALIANA SENSORI

ITALIANA SENSORI 8057-ISR043 Installation, operation and maintenance manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.