Frame Counting Sensor
Control output circuit diagram(NPN)
*(1) :Accuracy refers to the smallest particle size to achieve no blind area detection;
*(2) :Non-standard structure can be designed.
Model CX3068 CX6080
Accuracy
*(3)
100mA Max.
0~20ms
0~50ms
NPN(PNP type can be customized)Output
Circuit protection
Response time
Parameter
adjustment
Power supply
Sensing area*(2)
Connection
Current consumption
Load current
Line
color
definition
Protection degree
Weight
Single channel
Accessory
M8 connector, 4P M12 connector, 7P
40mA 90mA 70mA
DC10~30V(including voltage ripple of 10%(p-p)max.)*(4)
Operation: black; Alarm: red or white
Power: brown; ground: blue
Instruction, screwdriver
IEC IP64
414g
223g 395g 558g
Four channels*(1)
28*68 57.6*91.5 87*147 20*50
φ3mm φ3/φ5mm φ4mm
φ1.5/φ5mm
EX6080 CX90150
60.6*80
φ1.5/φ5mm
Individual
Common
Material
Case: aluminum, Black anode
Power on delay, power supply reverse polarity protection, output
short-circuit protection, output reverse polarity protection
1ms1.6ms
Indicators
Power indicator
(
green
)
, operation indicator
(
red
)
, Alarm
(
yellow
)
Ambient illumination
Ambient temperature
Ambient humidity
Incandescent lamp: Max. 5,000lx /Sunlight: Max. 50,000lx
Operation: -20~65 ℃; Storage: -30~80 ℃(with no icing and
condensation)
Operation: 45~85 %RH; Storage: 35%~95%RH (with no condensation)
Operation: black, white,
red, green; Alarm: yellow
*(1): The product has 26mm and 30mm channel spacing, which can be expanded into 8
channels and 12 channels;*(2): Effective areas for material testing should be large enough
to ensure that no collision or overlap occurs in the area;*(3): Minimum material size without
leakage or miscounted in sensing area;*(4): Customizable 5V low-power products for
battery-powered outdoor environments.
Non
Alarm output
A
CX 30 68 Tn Vn 3NF
Reset time
O
Fixing
On-delay function
A
Response time
Item
*(2)
Number Unit:mm
Vn Channel spacing
nNumber,4、6、8...
Number Unit:mm
Number Unit:mm
V:Channel spacing ,n:number(mm)
Tn:channel number,no need to fill in single channel
Length of sensing area,no need to fill in the ring series
Width of sensing area
Accuracy/Sensitivity
*(1)
Output
CX
RX
EX
Frame series
Ring series
Slot series
PG Miniature
Fixing
Off-delay functionF
NPN
PNPP
N
O
Alarm
INSTRUCTION MANUAL
! WARNING
! CAUTION
Thank for you selecting IMS product.This sheet primarily describes precautions
required in installing and operating the product.Before operating the product,read
the sheet thoroughly to acquire sufficient knowledge of the product.For your
convenience,keep the sheet at your disposal.
Failure to follow these instructions may result in serious injury or death:
Fail-safe device must be installed when using the unit with machinery that may
cause serious injury or substantial economic loss. (e.g. nuclear power control,
medical equipment, ships, vehicles, railways, aircraft, combustion apparatus,
safety equipment, crime/disaster prevention devices,etc.)
Failure to follow these instructions may result in product damage:
Do not use this unit over rated voltage;
Do not use this unit where there is flammable or explosive gas;
Do not use this unit where there is vibration or impact;
In cleaning the unit, do not use water or an oil-based detergent.
Features
Ordering information
Suitable for all types of materials, metal or non-metal
Fast Response time, down to 1ms
On-delay、Off-delay can be set
High performance ASIC with high immunity to EMI and environmental
interference
Built in algorithm to calculate the volume of passing object
Strong metal structure with M8 connector
Specifications
On-delay
Off-delay
Four channels
Alarm
indicator
(yellow)
Load
Brown(+)+V
10~30VDC
+
-
White/Green/Black/Red
(OUT)output
Blue(- )0V
Load
Yellow(ALARM)output
Operation
indicator
(red)
Main circuit
主
电
路
短路保护
黑色 : 动作输出 NPN
白色 : 稳定输出 NPN
棕色 : 12 ~ 30 VDC
①
②
③
④蓝色 : GND
电源指示灯
动作指示灯
上电调节及警报指示灯
Power
indicator
(green)
Operation
indicator
(red)
Alarm indicator
(yellow)
Main
circuit
Short circuit
protection
Black:Operation
output NPN
White:Stability
output NPN
Blue:GND
Brown:10~30VDC
Parameter adjustement
Max Max
1、The sensor has the function of automatic adjustment and can actively identify the
operating environment. Please fix the sensor before power on.
2、When powered on, in the first 3 to 5 second, the yellow LED in sensor will blink – sensor
is adjusting itself to optimal setting. During this period of time, do not do anything that
can influence the operation of the sensor, leave the sensor to itself until the yellow LED
stop blinking. If the yellow light keeping blinking for a long time without stopping,
please power off the sensor and power on again. If the problem remains, this means
sensor can’t adjust itself to optimal working condition. If this occurs, please contact us.
3、As the sensor’s optimal setting is influenced by its environment, after powered on, do
not move sensor to another place. If you move sensor to another place, please power
off and power on again.
4、The sensor has alarm output, when the sensor optimal working condition is degraded
due to factors such as dust accumulated on optical window, the sensor will have alarm
output – the yellow LED will light up and the Output of Red wire will changed(depends
on the mode of the sensor operation). If after cleaning the optical window, the sensor
still can not work, please contact us.
5、If encounting noise problem, please try to isolated high current from the sensor ground
loop. Try to use start connection, ground equipment with high current directly to ground,
ground the case of inductive motor to ground.
6、You can seek technical support by email us. [email protected].
CX6080
EX6080
Connector
CX90150
CX2050T4V30
Operation indicator
(red)
Alarm indicator
(yellow)
Power indicator
(green)
Operation indicator
(red)
Alarm indicator
(yellow)
Adjuster
Power indicator
(green)
Operation indicator
(red)
Alarm indicator
(yellow)
Adjuster
Intellisense Microelectronics
Tel:0592-8268993
Tax:0592-8268997
Web:www.chinasensors.cn
E-mail:[email protected]
Add:1F NO. 34 Guanri Rd, Xiamen software Park,Xiamen P.R. China
Caution for using
Dimensions
CX3068-3
Adjuster
Power indicator
(green)
Operation indicator
(red)
Alarm indicator
(yellow)
CX2050T4V26
Operation indicator(red)
Alarm indicator(yellow)
Port number Wire color
1 ---------------Brown
2 ---------------White
3 ---------------Black
4 ---------------Blue
Patent No. ZL 2015 2 0958415.X

This manual suits for next models

3

Other IMS Security Sensor manuals

IMS 171707 Specifications

IMS

IMS 171707 Specifications

IMS E3TA Series User manual

IMS

IMS E3TA Series User manual

Popular Security Sensor manuals by other brands

SOMFY 5012939 manual

SOMFY

SOMFY 5012939 manual

Huazheng HZJF-9011D user manual

Huazheng

Huazheng HZJF-9011D user manual

Gewiss Chorus GW 10 786 Technical manual

Gewiss

Gewiss Chorus GW 10 786 Technical manual

EGON HARIG flamtron FL (Ex) d 07 Series Assembly, Installation and Commissioning Instructions

EGON HARIG

EGON HARIG flamtron FL (Ex) d 07 Series Assembly, Installation and Commissioning Instructions

Major tech MT405EX instruction manual

Major tech

Major tech MT405EX instruction manual

MSA Altair operating manual

MSA

MSA Altair operating manual

Convoy Security WT105 Installation and maintenance instructions

Convoy Security

Convoy Security WT105 Installation and maintenance instructions

Visonic MCT-425 brochure

Visonic

Visonic MCT-425 brochure

Honeywell Eclipse Installing

Honeywell

Honeywell Eclipse Installing

DSC LC-120-PI installation manual

DSC

DSC LC-120-PI installation manual

Aritech GS620N installation manual

Aritech

Aritech GS620N installation manual

Berker Radio Detector 180 operating instructions

Berker

Berker Radio Detector 180 operating instructions

ELRO FH721011 instruction manual

ELRO

ELRO FH721011 instruction manual

Stahl FL6S Series operating instructions

Stahl

Stahl FL6S Series operating instructions

Bosch DS820i Series installation instructions

Bosch

Bosch DS820i Series installation instructions

Bircher Reglomat Hercules 2 Translation of the original operation instructions

Bircher Reglomat

Bircher Reglomat Hercules 2 Translation of the original operation instructions

ESYLUX EP10425806 installation instructions

ESYLUX

ESYLUX EP10425806 installation instructions

Van Walt Tetra 3 quick start guide

Van Walt

Van Walt Tetra 3 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.