Ref. FTA_GS_M_SC-PSA-en Rev: 0 23/06/23 9of 10
SC-PSA INSTALLATION MANUAL
G. Option 2, If a connection acting as an expansion joint is required: Insert the protruding part of the PSA-A joint
PSA-UN into the second PSE-C profile, leaving a gap between the ends of the two profiles of between 4 and 6
mm, in this case the screws are not installed to allow longitudinal displacements between the two profiles.
Is recommended for this type of connection a maximum distance to the nearest fixing point of
300 mm
INSTALLATION OF CLAMPS ON THE PROFILES
To mount the clamp on the profiles, the following steps are necessary:
1. Place the clamp in the profile
with the lower nut parallel to
the profile.
2. To fix the clamp to the
profile, the lower nut must be
turned perpendicular to the
profile by means of the screw,
the screw head is pressed down
and turned. The nut has a
serrated rail to secure the
fixing.
3. Insert the corresponding
elements, two panels in the
case of an intermediate clamp,
or a panel and a gauge in the
case of a lateral clamp.
4. To fix the inserted elements
it is necessary to turn the screw
until they meet the profile.
Check that the lower nut
remains perpendicular to the
profile.