Industrial Test Systems eXact iDip User manual

™
QUICK START GUIDE
TM

2
©2015, Industrial Test Systems, Inc. Printed in USA
CONTENTS
Welcome. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Warranty (2 years)....................................4
For Best Accuracy ....................................5
eXact iDip®Smart Photometer System™ Overview ..........6
Install “AAA” Batteries ...............................6
Getting Started
Download the App ...................................7
Download Additional Tests .............................7
Compatible Smart Devices ........................... 8-9
iDip®App Overview ..................................10
Using the iDip®App
Menu ............................................11
Test ..............................................11
History ...........................................12
Customers ........................................12
Calendar..........................................13
Store .............................................13
Results ...........................................13
Select, Fill, Dip, Read - Test Procedure
Select Customer....................................14
Power on eXact iDip®................................14
Select Bluetooth® Test ...............................15
Connect eXact iDip®................................15
Fill Cell ...........................................16
Select Test ........................................16
Zero Meter ........................................17
Parameter Test Methods .............................17
Standard Strip Method...............................18
Standard Liquid Method .............................19
Auto-Calculated Methods ......................... 20-21
Managing Data
Save/Send/Share ................................ 22-24
Troubleshooting .....................................25
Technical Support ..................................25
About
Bluetooth® SMART Technology........................26
Built-in Sample Cell .................................26
Making Calls.......................................26
eXact®Strip Micro CL Interferences ....................26
Compliance Testing (USEPA) .........................27
R&D 100 Award ....................................27
eXact iDip® Accuracy ................................28
Method Verication Ready Snap®......................28
Kits and Accessories
Easy Rell Box .....................................29
Dry Case for Smartphone or Tablet .....................29
Starter Kits ........................................30
Carrying Case for eXact iDip®.........................30
eXact® Micro Tests & Reagents ..................... 31-32

3
Sensafe.com
WELCOME TO YOUR NEW EXACT IDIP®
SMART PHOTOMETER SYSTEM™.
Thank you for your eXact iDip®purchase! This guide will quickly
walk you through the technical details of your new eXact iDip®.
This guide includes initial set-up, downloading the app, test
procedures, and tips. You are on your way to smart digital water
testing! Currently we offer two iDip®models: eXact iDip®(525nm)
and eXact iDip®570 (570nm). Please ensure you purchase the
compatible premium tests and strips/reagents according to the
iDip®model you are using.
eXact iDip
®
eXact iDip
®
570
YOUR EXACT IDIP®COMES WITH
:
•Cleaning Brush
•Quick Start Guide (this booklet)
•24 foil packet strips (6 of each): Free Chlorine (DPD-1),
Combined/Total Chlorine (DPD-3), pH, and Total Alkalinity
Note: The iDip®Starter Kits include eXact®Strip/Reagent
bottles with 25 tests each (reagents vary with each kit) and
not individual foil packets listed above.
WHAT YOU WILL NEED TO GET STARTED:
•Four (4) AAA batteries
•#4 Phillips head screwdriver
• eXact iDip®app
Visit sensafe.com to download the app, or see page 7 for app
download instructions
•Compatible smart device
For a list of compatible smart devices,
see pages 8-9
.
We are constantly adding new devices to this list. View the
most up-to-date list at sensafe.com/compatible-devices.
WELCOME
US Designed and US and International Patent-Protected by Industrial Test Systems, Inc. 1875 Langston Street, Rock
Hill, SC USA.
EXACT®, IDIP® , EXACT IDIP®, and READY SNAP®are registered trademarks and SMART PHOTOMETER SYSTEM™,
SMART BREW™, and SMART DIGITAL WATER TESTING™are trademarks of Industrial Test Systems, Inc. Rock Hill, SC USA. Apple, the
Apple logo, iPad, iPhone, and iPod touch are trademarks of Apple Inc., Android, Google, and Google play are trademarks of Google
Inc., Registered in the U.S. Bluetooth®word mark and logos are owned by Bluetooth SIG and any use of such marks is under license.
MarketWatch and R&D 100 are registered trademarks of each.

4
©2015, Industrial Test Systems, Inc. Printed in USA
THE EXACT IDIP®
SMART PHOTOMETER SYSTEM™
Using eXact® Micro reagents in combination with the
app and photometer completes the eXact iDip®Smart
Photometer System™. Each test will require the use of one or
more of the testing methods outlined in this manual.
This system’s unique and innovative technologies have
earned the eXact iDip®US and international patents (US
Patents #7,333,194 and #7,491,546, Euro Pat No. 1 725
864 DE FR UK, and South African Patent #2007/0628) for
underlying technology, and currently pending are US Pat
App 13/651305 and Euro Pat App 2 906 942 for technical
features relating to two-way data communication between a
photometer and a smart device.
Note:
This system has been manufactured for use with only
our eXact®Micro reagents.
WARRANTY (2 YEARS)
Registration of your eXact®photometer must be received within 30
days from date of purchase to activate the warranty. Registration
is available over the phone (+1-803-329-9712 Ext. 0) or online at
sensafe.com/micro/warranty/ (Personal data is kept condential).
The eXact®photometer is warranted to be free from defects in
materials and workmanship for a period of two (2) years from
the date of purchase by the customer. ITS will repair or replace,
at its discretion, product which is deemed to be faulty due to
manufacturing defect. Warranty does not cover product damage
caused by abuse (such as crushing a tablet in the cell), battery
corrosion damage, or improper use. If the meter is faulty or
otherwise defective contact ITS by phone (1-803-329-9712 Ext. 0)
or email (its@sensafe.com) to describe the problem and obtain a
return authorization form before returning the photometer to ITS.
Damage caused by improper packing of the photometer for return
shipment to ITS will not be covered by the warranty. Customer is
responsible for shipping charges to ITS. ITS pays postage when
photometer is returned to customer. A maximum processing fee
of $75 will be charged for repair or replacement of non-registered
photometers and damages not covered by this warranty. The repair
or replacement of the photometer will not extend or renew the
period of guarantee. This warranty does not affect your statutory
rights. The warranty is not transferable.
WELCOME

5
Sensafe.com
FOR BEST ACCURACY
All tests that begin with 570 are for use with the eXact iDip
®
570 Smart
Photometer only.
Visit sensafe.com/idip/ for individual test instructions.
The meter has a default 3 minute automatic shutoff timer. You can change
the duration in the ‘Settings’ menu located within the eXact iDip
®
app.
Always ll the cell to capacity (4mL).
Test immediately after lling the cell with the water sample.
When testing pH, it is recommended to run the pH test prior to running
Chlorine. If you choose to run the pH after Chlorine, ensure you
thoroughly clean the cell with water and the brush provided.
To obtain optimal accuracy when testing outdoors (sunlight), use the
Cell Cover when zeroing and reading the sample.
Due to the strip slitting process, you may nd one or two strips that are
noticeably smaller or larger in width than the normal strips in the bottle.
These should be discarded. Using these strips may give unreliable results.
Meter is not compatible for use with powder pillows, tablets, and liquids
from other manufacturers.
Dip strip for entire countdown.
Each eXact
®
Strip Micro is valid for ONLY one test. Discard strip after use.
Dry the outside of the meter before storage.
Remove batteries before storing for prolonged periods.
Store the meter and test materials out of direct sunlight and away from
chemical storage areas.
Minimize exposure of meter and test reagents to heat above 90°F (32°C).
When installing batteries, make sure that the O-ring is still attached to
the screw before tightening.
To pair the eXact iDip
®
Smart Photometer with your smart device, open
the app and connect through the app. You cannot connect the devices
in the settings section of your smart device.
All results must be saved from the results page to history in order to
permanently save to your smart device.
The eXact iDip
®
Smart Photometer may experience Bluetooth
®
disconnection when submerged in water too deep. To avoid this,
collect water sample in a small container/cup and pour or pipette
(contact us for ordering) the water into the Sample Cell.
To ensure lab quality results, it is recommended to clean the cell with
the brush provided after every test.
Cleaning the cell with water and brush after each test and prior to
storage of unit is recommended. Use Distilled White Vinegar to clean
the cell after testing for Phosphate or Iron to remove reagent deposits
from the cell wall.

6
©2015, Industrial Test Systems, Inc. Printed in USA
IDIP® SMART PHOTOMETER OVERVIEW
YOUR NEW EXact iDip®SmaRt phOtOmEtER iS iDEaL
FOR tEStiNg aND maiNtaiNiNg DRiNKiNg WatER, pOOLS,
SpaS, pONDS, aqUaRiUmS, FOOD pROcESS WatER,
ENviRONmENtaL WatERS, aND mORE!
SampLE cELL - 4 mL
Built-in plastic 4mL cell
for collecting your water
sample
LcD DiSpLaY
Displays results
and test name
Light SOURcE
Uses 525nm or
570nm wavelength,
depending on model
purchased, and
11mm path-length
for testing
REaD BUttON
Starts test timer
BaSE
Install/replace batteries here
(IP67 rated waterproof)
RESULt
UNitS
LOW
BattERY
BLUEtOOth
cONNEctED
LCD DISPLAY
ZERO/ON BUttON
Powers on the
meter and creates
a baseline for your
water testing
cELL cOvER
Covers the cell for
mixing and bright
light situations
Protected against the effects
of immersion in water to depth
between 15 cm and 1 meter
ScREW
Unscrew to
remove base
Part no. 486101
iNStaLL “aaa” BattERiES (NOt iNcLUDED)
1. Use a #4 Phillips head screwdriver to remove the screw
from the base of your eXact iDip®
.
2. Remove the base.
3. Install Four (4) new AAA batteries as illustrated inside
your iDip’s battery compartment. We recommend using
high quality batteries.
4. Replace the base rmly with pressure while tightening the
screw. The meter will turn on automatically.
5. Tighten the screw with #4 Phillips head screwdriver. Be
sure not to over tighten.

7
Sensafe.com
DOWNLOAD THE APP
Using your Smart Device, download the eXact iDip®
app. The eXact iDip®application is the brain for this
system, download the latest update to ensure you are
using the current version with up-to-date tests and
features. To see if your smart device is compatible,
reference our table on pages 8 and 9 of this manual.
We are constantly improving the
eXact iDip®app and welcome your
suggestions. Visit www.sensafe.com/idip
or e-mail your feedback to exactidip@
sensafe.com.
DOWNLOAD ADDITIONAL TESTS
The app comes pre-installed with tests for Total Alkalinity,
Free Chlorine, Combined Chlorine, and pH. Ensure you
have any additional tests you need by visiting the Store in
the eXact iDip®app. All tests that begin with 570 are for
use with the eXact iDip®570 Smart Photometer only.
Step-by-step instructions on using the Store function of the
app can be found on page 13.
APP STORE
DOWNLOAD GOOGLE PLAY
DOWNLOAD
To view an instructional video,
please visit sensafe.com/idip.
Note:
If using an Apple®iPad™, ensure you select 'iPhone
only app' when searching from the App Store, or scan the
QR code above.
GETTING STARTED

8
©2015, Industrial Test Systems, Inc. Printed in USA
COMPATIBLE SMART DEVICES
SMART PHONE COMPATIBILITY
Updated 07/15/15
For updated list visit www.sensafe.com/compatible-devices
APPLE SAMSUNG MOTOROLA DROID MOTOROLA HTC
LG SONY GOOGLE LENOVO ZTE
iPhone 4s Galaxy Ace Style Maxx Moto E Desire 610
F70 Xperia AX Nexus 4 Vibe X2 Pro Grand S II
iPod touch 5th Galaxy Core II Mini Moto G Desire 816
G Pro2 Xperia E1 Nexus 5 Vibe Z Grand S3
iPhone 5 Galaxy Core Lite Razr HD Moto X One
G2 Xperia M Nexus 6 Vibe Z2 Nubia X6
iPhone 5c Galaxy Core Prime Razr HD Maxx One (E8)
G2 Mini Xperia M2 Vibe Z2 Pro Nubia Z5S Mini
iPhone 5s Galaxy Grand 2 Razr M One (M7)
G3 Xperia SP Vibe Z3 Pro Nubia Z7
iPhone 6 Galaxy Grand Duos Ultra One (M8)
Optimus Exceed 2 Xperia T2 Ultra Nubia Z7 Max
iPhone 6+ Galaxy Grand Neo One Max
Optimus Fuel Xperia VL Nubia Z7 Mini
Galaxy J One Mini
Optimus G Xperia Z Nubia Z9 Mini
Galaxy Mega One Mini 2
Optimus G Pro Xperia Z ULTRA
Galaxy Mega 2
Optimus L35 Xperia Z1
Galaxy S3
Optimus L40 Xperia Z1 Compact
Galaxy S3 Neo
Optimus L65 Xperia Z1F
Galaxy S4
Optimus L70 Xperia Z1S
Galaxy S4 Active
Optimus L80 Xperia Z2
Galaxy S4 Mini
Optimus L90 Xperia Z3
Galaxy S4 Zoom
Optimus Zone 2 Xperia ZL
Galaxy S5
Volt Xperia ZR
Galaxy S5 Active
Xperia ZR
Galaxy S5 Sport
Galaxy Xcover 3
Galaxy Young II Duos
TABLET COMPATIBILITY
APPLE SAMSUNG MOTOROLA DROID MOTOROLA HTC
LG SONY GOOGLE LENOVO ZTE
iPad (3rd) Galaxy Note 10.1
G Pad Xperia Tablet Z Nexus 7 (2013)
iPad (4th) Galaxy Note 3 Neo
Xperia Tablet Z2 Nexus 9
iPad Air
Galaxy Note 3 Neo Duos
iPad Air II Galaxy Note 4
iPad Mini Galaxy Note 8.0
iPad Mini II Galaxy Note II
iPad Mini Retina Galaxy Note II Duos
Galaxy Note III
Galaxy Note III Round
Galaxy Note Pro
Galaxy Tab 3 V
Galaxy Tab 4
Galaxy Tab Pro
Galaxy Tab S
This list is current as of July, 2015. To view the most up-to-date list of compatible
devices, please visit sensafe.com/compatible-devices.
VIEW INSTRUCTIONAL VIDEO

9
Sensafe.com
VIEW EXACT IDIP
®
COMMERCIAL
SMART PHONE COMPATIBILITY
Updated 07/15/15
For updated list visit www.sensafe.com/compatible-devices
APPLE SAMSUNG MOTOROLA DROID MOTOROLA HTC
LG SONY GOOGLE LENOVO ZTE
iPhone 4s Galaxy Ace Style Maxx Moto E Desire 610
F70 Xperia AX Nexus 4 Vibe X2 Pro Grand S II
iPod touch 5th Galaxy Core II Mini Moto G Desire 816
G Pro2 Xperia E1 Nexus 5 Vibe Z Grand S3
iPhone 5 Galaxy Core Lite Razr HD Moto X One
G2 Xperia M Nexus 6 Vibe Z2 Nubia X6
iPhone 5c Galaxy Core Prime Razr HD Maxx One (E8)
G2 Mini Xperia M2 Vibe Z2 Pro Nubia Z5S Mini
iPhone 5s Galaxy Grand 2 Razr M One (M7)
G3 Xperia SP Vibe Z3 Pro Nubia Z7
iPhone 6 Galaxy Grand Duos Ultra One (M8)
Optimus Exceed 2 Xperia T2 Ultra Nubia Z7 Max
iPhone 6+ Galaxy Grand Neo One Max
Optimus Fuel Xperia VL Nubia Z7 Mini
Galaxy J One Mini
Optimus G Xperia Z Nubia Z9 Mini
Galaxy Mega One Mini 2
Optimus G Pro Xperia Z ULTRA
Galaxy Mega 2
Optimus L35 Xperia Z1
Galaxy S3
Optimus L40 Xperia Z1 Compact
Galaxy S3 Neo
Optimus L65 Xperia Z1F
Galaxy S4
Optimus L70 Xperia Z1S
Galaxy S4 Active
Optimus L80 Xperia Z2
Galaxy S4 Mini
Optimus L90 Xperia Z3
Galaxy S4 Zoom
Optimus Zone 2 Xperia ZL
Galaxy S5
Volt Xperia ZR
Galaxy S5 Active
Xperia ZR
Galaxy S5 Sport
Galaxy Xcover 3
Galaxy Young II Duos
TABLET COMPATIBILITY
APPLE SAMSUNG MOTOROLA DROID MOTOROLA HTC
LG SONY GOOGLE LENOVO ZTE
iPad (3rd) Galaxy Note 10.1
G Pad Xperia Tablet Z Nexus 7 (2013)
iPad (4th) Galaxy Note 3 Neo
Xperia Tablet Z2 Nexus 9
iPad Air
Galaxy Note 3 Neo Duos
iPad Air II Galaxy Note 4
iPad Mini Galaxy Note 8.0
iPad Mini II Galaxy Note II
iPad Mini Retina Galaxy Note II Duos
Galaxy Note III
Galaxy Note III Round
Galaxy Note Pro
Galaxy Tab 3 V
Galaxy Tab 4
Galaxy Tab Pro
Galaxy Tab S
The eXact iDip®Smart Photometer requires the use of a smart device with
Bluetooth®4.0 and Android 4.3 or greater.
COMPATIBLE SMART DEVICES

10
©2015, Industrial Test Systems, Inc. Printed in USA
hiStORY:
Accesses
saved results
which can be
sorted, edited,
and emailed.
Also accesses
History Map
caLENDaR:
Displays your
schedule/
appointments
StORE:
Opens store
to unlock
additional tests
cUStOmERS:
Attaches
results to
people and/or
locations from
your
smart
device contacts
tESt:
Initiates water
testing
RESULtS:
Accesses temporary
results that have
not been saved to
history
mENU:
Opens
slide-out for
easy access to
all app features
BLUEtOOth
DEvicE
tEStiNg
paRamEtER
tESt RESULt
HOME SCREEN
TEST RESuLT SCREEN
tESt
aBBREviatiON
paRamEtER
UNit OF mEaSURE DOtS iNDicatE
mULtipLE UNitS OF mEaSURE
Swipe unit of measure values.
(Available for some tests)
®
®
IDIP®APP OVERVIEW

11
Sensafe.com
MENU
The Menu slide-out is available from any
screen within the app. The Menu
allows you
to access any of the app’s features with ease.
HOW TO CHANGE THE TIMEOUT DURATION
The timeout setting is used to turn off the eXact iDip®Smart
Photometer. The default setting is 3 minutes, however this
can be adjusted. To do this, tap 'Settings' in the Menu
slide-out
and tap either '+' or '–'.
Note: You may need to change the Auto-Lock time on your
smart device to allow for testing time (instructions will vary for
phone or tablet make/model)
HOW TO VIEW YOUR GPS LOCATION
ln the Settings screen you can view your current GPS
coordinates and/or refresh your current location coordinates.
In order to take advantage of the GPS feature, make sure to
allow eXact iDip app to access your location.
ABOUT
Access the End-User License Agreement and contact
information to reach our ofces in the USA and Europe from
the About section, located in the Menu slide-out.
Located in the About section you can nd the version of the
app you are running. Be sure to check for updates and install
the latest version before running a test as we are constantly
updating and adding more features to the app!
FAQS
Here you will nd videos, downloads, links, and answers to
the most frequently asked questions.
TEST
You can utilize two different testing methods
under Test:Manual Entry or Bluetooth Device.
BLUETOOTH TEST
Tests will be performed with your eXact iDip®Smart
Photometer using the
STANDARD STRIP METHOD
(page 18),
STANDARD LIQuID METHOD
(page 19),
NON-STANDARD METHODS
, or
AuTO-CALCuLATE METHODS
(pages 20-21) test procedure.
MANUAL TEST
This feature allows you to utilize other testing methods and
manually enter your results into the app. Begin by selecting
'Test', 'Manual Entry',and select your desired test. Enter the
value obtained. Once nished, tap 'SAVE' at the top left. If the
test you need to enter is not available on the list, tap 'Custom*'.
Enter the type of test that was run, the value obtained, and the
unit of measure used. Then, tap 'SAVE' at the top left.
USING THE IDIP®APP

12
©2015, Industrial Test Systems, Inc. Printed in USA
USING THE IDIP®APP
HISTORY
The History stores all your saved test result
information and allows you to sort by date,
customer name, or test type.
HOW TO SORT BY CUSTOMER
To sort by Customer begin by selecting 'History', then
'Sort by', 'Customer'.You can then scroll through your list of
customers by name, to nd a specic test result.
HOW TO SORT BY DATE
To sort by Date begin by selecting 'History' then 'Sort by',
'Date'. You can then scroll through a list of tests performed
by date. You can also set a specic date range by selecting
'Date range'. Then set your From and To dates.
HOW TO SORT BY TEST
To sort by Test begin by selecting 'History' then 'Sort by',
'Test'.You can then scroll through a list of tests sorted in
alphabetical order.
HOW TO ACCESS HISTORY MAP
The History Map stores GPS locations of testing sites. See
page 24 for instructions on how to utilize this feature.
HOW TO EMAIL AND SHARE DATA
See page 23 for instructions on how to utilize these features.
CUSTOMERS
Customers attaches results to people and/or
locations in your smart device. In order to fully
utilize the features and capabilities of the app, each test
result will need to be stored (linked) to a prole.You can add
customers in two ways. 1. By adding from your existing contact
list on your smartphone/tablet or 2. You can create a new contact.
HOW TO ADD EXISTING CONTACTS
To add current contact information already stored on
your device, begin by selecting 'Customers' then 'Add
customers from contacts'.
HOW TO CREATE A NEW CONTACT
To create a new contact, select 'Customers', tap the '+',
then enter all of the customers contact information. Once
nished tap 'Done'.

13
Sensafe.com
USING THE IDIP®APP
CALENDAR
Never miss an appointment! With the app’s
Calendar feature, you can access your device’s
calendar directly from the app. View by date range
to see past entries or future appointments.
STORE
The eXact iDip®app comes pre-installed with
tests for Total Alkalinity, Free Chlorine, Combined
Chlorine, and pH. You can purchase and unlock
over 30 additional tests from the Store located in
the app (eXact®Strips/reagents not included).
To purchase additional tests, begin by selecting 'Store',
scroll to the test you would like to purchase, and tap 'Buy'
(this will unlock the test in the app). When purchasing
tests in the app, be sure to select the appropriate test for
your eXact iDip®Smart Photometer. To order eXact®Strips/
reagents, contact your local supplier or order online (see
pages 31-32 for a list of available reagents).
RESULTS
You can view details for tests that have not been
saved to History, add notes, or clear recent test
history from the Results section.
HOW TO ADD NOTES
To add notes begin by selecting 'Results' then select the
test result you would like to add notes to. Tap inside the blue
note section of the Results screen and add your notes. The
app will automatically save the information you enter.
Tap 'Results' to return to the previous screen.
HOW TO CLEAR PREVIOUS TEST RESULTS
To clear ALL recent test results, tap 'Results', then 'Reset'.
A notication screen will display 'Reset data results'
.
“Are
you sure you want to reset all the results and notes?” Tap
'Yes'
to clear.
If no entries are visible in the app, you may need to
allow the app to access your calendar. You can do this
in the settings and security section of your smartphone/
tablet (instructions for each will vary by make/model).
TIP

14
©2015, Industrial Test Systems, Inc. Printed in USA
SELECT, FILL, DIP, READ
SELECT CUSTOMER
a. Select
'Customers'
from the
'Home'
screen.
b. Tap
'Add customer from contacts'.
c. Select a contact from your list. After selecting a
contact, tap on the customer's address if shown.
Android users: If no address is found, tap "No
addresses found"
d. Verify customer has been selected.
Note:
In order to take full advantage of the GPS and Data
Storage features, each test result is linked to a contact.
POWER ON EXACT IDIP®
Press the button to power on the eXact iDip
®
.
Before you begin, ensure you have downloaded the app and all
necessary tests you require. For helpful tips regarding test procedures,
refer to tips “FOR BEST ACCURACY” on page 5.
After adding a customer, a test will need to be conducted
and a result saved in order for the customer’s information to
display in the app’s customers list.
TIP
You can also choose to complete this step after testing.
TIP
b
d
c
a
Apple
b
d
c
a
Android

15
Sensafe.com
SELECT, FILL, DIP, READ
SELECT
BLUETOOTH®TEST
Tap the menu slide out ‘ ’
and select
'Bluetooth Test'
from the choices shown.
CONNECT EXACT IDIP®
The eXact iDip
®
app will automatically connect to the
most recently used eXact iDip
®
Smart Photometer.
If not, select your eXact iDip
®
from the bottom of the
screen. Verify it has connected and tap 'OK'.
Note: Ensure you always connect your eXact iDip®
Photometer via the Bluetooth® connection within the app.
To verify connection look for the Bluetooth icon in the
upper right corner of your photometer.
If you experience an issue connecting your device,
check to ensure that your smartphone/tablet’s Bluetooth®
function is turned on and your device is compatible.
Refer to the back of your
eXact iDip
®
to determine the
serial number for your device.
This will also be the name for
the Bluetooth
®
connection.
Bluetooth®SMART is a low–power
wireless networking standard which
uses short radio waves to allow
electronic devices to communicate with each other. For more
information regarding Bluetooth®SMART, see page 26.
TIP
Easily verify your device.
Date/Time Sync Successful
Check LCD display for Bluetooth icon.

16
©2015, Industrial Test Systems, Inc. Printed in USA
SELECT TEST
Tap
'Select Test'
at the top (e.g. Alkalinity, Total).
The eXact iDip
®
and app will both display the
test being run. If using the eXact iDip
®
570, all
available tests will begin with 570 (see below).
FILL CELL
Rinse the cell 3 times with the water sample to
be tested and fILL to the top to begin test.
Use the included cleaning brush to clean the cell after
each test to achieve the most accurate result.
TIP
Alkalinity, Total AL
Bluetooth Test
Alkalinity, Total AL Selected
SELECT, FILL, DIP, READ

17
Sensafe.com
ZERO METER
Press and the iDip®display reads 0PPM
indicating the meter is ready for testing.
In bright light situations use cell cover for zeroing and reading.
TIP
NON-STANDARD
METHODS
Download at sensafe.com/idip
Ammonia (eXact iDip
®
570 only) Sulde (as S
2-
) (180 sec)
Chloride, HR (as NaCl) Turbidity
Chlorine, Combined SPA Alkalinity, Total
Chlorine Dioxide SPA Bromine, Total
Hardness, Total (when AL >200 ppm)
SPA Hardness, Calcium
Iron, Total SPA Chlorine, Free
Manganese (as Mn
+2
) SPA pH
Molybdate (120 sec)
AUTO-CALCULATED
METHODS
Chlorine, Combined Hardness, Magnesium Reserve Alkalinity
Chlorine, Total Langelier Saturation Index (LSI) Sodium
See pages 20-21
Alkalinity, Total
Bromine, Total
Chloride (as NaCl) Nitrate (as NO
3
) (600 sec)
Chlorine, Free Nitrite (as NO
2
) (360 sec)
Chlorine, Total (120 sec) Ozone
Chlorine, Total High (120 sec) Peracetic Acid Low
Chromium (VI) (240 sec) Peracetic Acid
Copper (as Cu
+2
)(120 sec) Permanganate
Hardness, Calcium (as CaCO
3
) pH
Hardness, Total High (as CaCO
3
) pH, Acid
Hardness, Total Low (as CaCO
3
) pH, Alkali
Hydrogen Peroxide (100 sec) Phosphate (as PO
4
) (120 sec)
Hydrogen Peroxide High Sodium Bromide (as NaBr)
Hydrogen Peroxide Low (120 sec) Sulfate (as SO
4
)
Iodine
Proceed to step 8 on page 18
STANDARD STRIP METHOD
The STANDARD STRIP METHOD (page 18) applies to both the eXact
iDip
®
Smart Photometer and the eXact iDip 570 Smart Photometer
(some tests require a count-up time, listed below).
STANDARD LIQUID METHOD
Cyanuric Acid (5 drops, 60 sec) pH-BT
(eXact iDip
®
570 only)
(2 drops)
Fluoride
(eXact iDip
®
570 only)
(10 drops)
Metals (2 drops, 120 sec)
The
STANDARD LIQuID METHOD
(page 19) involves adding the specied
number of drops (below) and mixing for a 20 second count-down (some
tests require a count-up time, listed below).
Proceed to Step 8 on page 19
SELECT, FILL, DIP, READ

18
©2015, Industrial Test Systems, Inc. Printed in USA
STANDARD STRIP METHOD
DIP STRIP AND PRESS READ
Press to initiate a 20 second countdown and
simultaneously DIP the eXact® strip by submerging all
pads in the sample then use a gentle constant back
and forth motion (2 strokes per second) until the timer
displays
'1'
. Remove and discard the strip. Wait for
count-up time if required.
REMOVE STRIP
Remove one eXact®Strip Micro (e.g. Total Alkalinity) and
set in a dry, convenient place. Replace cap on bottle.
READ RESULTS
READ result displayed on the iDip®and in the app.
To run additional tests, repeat steps 5-9. To save,
send, and share results, proceed to page 22 prior
to closing the app.
TIP
On the Test Result Screen, swipe the result to the left,
or right, to view alternative units of measure.

19
Sensafe.com
STANDARD LIQUID METHOD
SHAKE BOTTLE & ADD DROPS
Tilt meter to discard about 0.2mL water in order to leave
room for liquid reagent. Shake the bottle of eXact®
Reagent (e.g. Cyanuric Acid) and add drops. Ensure the
reagent bottle remains vertical while adding drops.
COVER, PRESS READ, & MIX
Place the Cell Cover onto the CELL. Press
and a 20 second countdown begins. Turn the meter
upside-down repetitively during the 20 seconds.
When the timer displays '1', place the eXact iDip
®
on
a at surface. Wait for count-up time.
READ RESULTS
READ result displayed on the eXact iDip®and in
the app. To run additional tests, repeat steps 5-9.
To save, send, and share results, proceed to page
22 prior to closing the app.
Cyanuric Acid CY
81
ppm

20
©2015, Industrial Test Systems, Inc. Printed in USA
AUTO-CALCULATED METHODS
MAGNESIUM HARDNESS
Use the STANDARD STRIP METHOD, as illustrated on page
18 to perform tests for Total Hardness and Calcium
Hardness. Then, tap Results at the bottom of the page
and a Magnesium Hardness value will be calculated
automatically.
RESERVE ALKALINITY
Use the procedure above to obtain a Magnesium Hardness
value. Then use the STANDARD STRIP METHOD as illustrated
on page 18 to perform the test for Total Alkalinity. Lastly, tap
Results at the bottom of the page and a Reserve Alkalinity
value will be calculated automatically.
SODIUM
Use the procedure above to obtain a Reserve Alkalinity
value. Then use the STANDARD STRIP METHOD as illustrated
on page 18 to perform tests for Chloride and Sulfate. Lastly,
tap Results at the bottom of the page and a Sodium value
will be calculated automatically.
If you would like to obtain all three test results listed above,
you can perform all required tests (Total Hardness, Calcium
Hardness, Total Alkalinity, Chloride, and Sulfate) and then go
to Results. At this point, all three values will be automatically
calculated simultaneously (see below).
Other manuals for eXact iDip
1
Table of contents
Other Industrial Test Systems Test Equipment manuals