Industrial Test Systems Pool eXact EZ User manual

1
QuicK stArt guiDe
ADVANCED PHOTOMETER SYSTEM
DigitAl AccurAcy For better pool cAre

2
2
Welcome to your neW pool eXAct®eZ photometer
This guide shows you the technical details on your Pool eXact®EZ
photometer and gets you started with tips for the tests you will use daily.
Your Pool eXact
®
EZ Photometer comes with:
Cleaning Brush
Quick Start Guide
6 Strips each of: Free Chlorine (DPD-1), Combined/Total Chlorine
(DPD-3), pH, Calcium Hardness, and Total Alkalinity
You will need Four (4) AAA batteries and a Phillips head screwdriver to
start testing your water.
bAttery instAllAtion (bAtteries not incluDeD)
1. Use a Phillips head screwdriver to remove the screw from the
base of your Pool eXact®EZ Photometer.
2. Remove the base.
3. Install 4 new AAA batteries as illustrated inside your Pool
eXact®EZ Photometer. We recommend using high quality
batteries.
4. Replace the base rmly with pressure while tightening the
screw. The meter will power on automatically.
COnTenTS
WelCOMe
Welcome
Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Battery Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2
Meter Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
Fill, Dip, Read
Standard Strip Method . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Combined/Total Chlorine Test . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Cyanuric Acid Test. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
About
Accuracy and Calibration. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Compliance Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
About the Built-In Sample Cell . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Assigned Value for Ready Snap
®
3 . . . . . . . . . . . . . . . . . . . . . . . . .10
Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Reorder . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Technical Support . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
SCREW
Unscrew to
remove base

3
We developed the revolutionary Pool eXact
®
EZ photometer to easily
maintain pool water quality. It uses state of the art technology to
produce lab-quality results poolside. The Pool eXact
®
EZ photometer
is waterproof (IP-67) and has a built-in sample cell to enhance
usability.
MeTer OVerVIeW
SAMPLE CELL
Built-in plastic 4ml cell for
collecting your water sample
LCD DISPLAY
Displays results and
test name
READ BUTTON
Starts test timer
MENU BUTTON
Cycles through test
menus
BASE
Install/replace batteries here
(IP67 rated waterproof)
RESULT
UNITS
LOW
BATTERY
lcD DisplAy
ZERO/ON BUTTON
Turns the meter on and
creates a baseline for
your water testing
CELL COVER
Covers the cell for
mixing and bright light
situations
*Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run first.
For resellers and distributors - products sold in case quantities (12 units per case).
PARAMETER/TEST
No. PART # RANGE
1
2
3
4
5
6
7
For use in accordance with
U.S. Patent No. 7,333,194,
U.S. Patent No. 7,491,546, South African Patent No. 2007/0628,
EU Patent #1,725,864, and International Patent Appln. No. PCT/US2005/033985
TESTS
eXact Pool Water Refill Kit
Alkalinity, Total
Calcium (as CaCO3)
Chlorine, Free (DPD-1)
Chlorine, Combined (DPD-3)*
Chlorine, Total (DPD-4)
Cyanuric Acid
pH
486211
486641
486629
486637
486638
486670
481652-II
486639-II
N/A
11 - 200 ppm
19 - 550 ppm
0.05 - 12 ppm
0.05 - 12 ppm
0.05 - 12 ppm
3 - 110 ppm
6.0 - 8.5
as below
100
50
100
100
100
60
100
R052814
Pool eXact®EZ Photometer Specifications

4
This method can be used with the following tests:
Total Alkalinity Free Chlorine (DPD-1)
pH Calcium Hardness
Total Chlorine (DPD-4)
Remove one eXact
®
Strip Micro (e.g. Free Chlorine / DPD-1)
from the bottle or foil packet and set in a dry, convenient place.
Turn meter on by pressing ZERO/ON. The display will indicate
current MENU, followed by the last test result.
Press and re-press MENU until the display shows the
parameter to be tested (e.g. CL1 matches CL on bottle).
STAnDArD STrIP MeThOD
1
2
3
FIll, DIP, reAD
CL1

5
Rinse the sample cell 3 times with the water sample you are
testing and Fill the built-in sample cell.
Press ZERO/ON. The cursor will move across the display
followed by 0 PPM or PH.
Dip the eXact
®
Strip Micro into the sample cell and
simultaneously press READ. This starts the 20 SECOND
countdown timer. During this time move the strip in a gentle
back and forth motion (approx. 2 strokes/sec). Remove and
discard the strip after “1” on the display disappears.
The cursor will move across the display while the meter
prepares to measure the sample. reAD result displayed. After
testing is complete, rinse the sample cell immediately.
5
6
7
FIll, DIP, reAD
4

6
This procedure is a continuation from Standard Strip Method
on previous page after running Free Chlorine (DPD-1). DO
NOT DISCARD SAMPLE AFTER FREE CHLORINE TEST.
Remove one (1) eXact
®
Strip Micro CL (DPD-3), Part No. 486638
from the bottle or foil packet. Set it in a dry, convenient place.
With the DPD-1 sample still in the cell, press ZERO/ON.
The display reads 0 PPM.
Dip the eXact
®
Strip Micro CL (DPD-3) into the CELL
and simultaneously press READ. This starts another 20
SECOND countdown timer. During this time move the
strip in a gentle back and forth motion (approx. 2 strokes/
sec). Remove and discard the strip after “1” on the
display disappears.
FIll, DIP, reAD
8
9
10
COMBIneD/TOTAl ChlOrIne TeST

7
The cursor will move across the display while the meter
measures the sample. reAD the Combined Chlorine value
displayed.
If you require a value for Total Chlorine, press READ
again and record result displayed. After testing is
complete, rinse the sample cell immediately.
FIll, DIP, reAD
11
12
SCAn FOr TeST
DeMO VIDeO

8
Turn meter on by pressing ZERO/ON. The display will indicate
current menu, followed by the last test result.
Press and re-press MENU until the display shows the
parameter CY5.
Rinse the sample cell 3 times with the water sample you will
be testing and ll the sample cell.
Using the cell cover, cap the sample cell and press ZERO/ON.
The cursor will move across the display, followed by 0 PPM
1
2
3
4
FIll, DIP, reAD
CY5
CYAnUrIC ACID TeST

9
Shake the bottle of eXact
®
Reagent CY II, Part No. 481652-II
to mix the suspension in the bottle. Add ve (5) drops of the
eXact
®
Reagent CY II to the sample cell. Keep reagent bottle
vertical while adding drops.
Place the cell cover onto the sample cell. Press READ and
a 20 second countdown begins. Place thumb or nger over
cap, and mix the sample by turning the meter upside-down
repetitively during the 20 second countdown.
When timer displays 1, place meter on at surface (upright)
and the meter begins a 60 second count up timing, at the
end of which, the cursor will move across the display while
the meter prepares to measure the sample. Record result
displayed (this result is automatically stored in CY5). Rinse the
cell immediately and use the cleaning brush to remove any
residue from the previous test.
5
7
6
FIll, DIP, reAD

10 ABOUT
AccurAcy & cAlibrAtion
All tests have been calibrated using certied reference standards and
standard analytical spectrophotometric methods. The algorithms in
the software reect the best correlation of the Pool eXact
®
EZ system
against the AWWA, US EPA , DIN, and ISO reference test methods
for chlorine. Studies show that the Pool eXact
®
EZ System repeatedly
agrees with an EPA Compliant reference method greater than 99%. The
Pool eXact
®
EZ meter Advanced Photometric System has been factory
calibrated and you can expect the xed calibrations in the meter to be
valid for the life of the meter because of the quality, Long-Life LED, the
photo cell, and the software.
Free & totAl chlorine testing heAlth DepArtment compliAnce
This DPD test system for Chlorine is accepted for reporting by most
health departments because the test is USEPA (DIN Standard 38 408
G4, ISO 7393/2) accepted for testing requirements for Free and Total
Chlorine. The compliance requirement is a photometer wavelength to
measure between 490 and 530nm. The Pool eXact®EZ photometer uses
a 525nm wavelength. The eXact®Strip Micro CL (DPD-1) uses the same
reagents and proportions, and the resulting solution pH is maintained
between 6.2 and 6.5 as specied by AWWA method 4500-Cl G. The
USEPA does not “approve” commercial DPD delivery systems. The
eXact®Strip Micro CL (DPD-1) for Free Chlorine, and the eXact®Strip
Micro CL (DPD-3) for Combined Chlorine or the eXact®Strip
Micro CL (DPD-4) for Total Chlorine meet your reportable
testing requirements because the eXact®Strip Micro CL
delivers the same chemicals in identical proportions.
About the built-in sAmple cell
The built-in sample cell is made of transparent plastic; the sturdy cell design
will last for over 20,000 readings. Scratches on the cell will not compromise
the accuracy of your results because of the cell’s xed position.
cleAning the sAmple cell
Fill the sample cell with water and use the enclosed cleaning brush
to scrub the sample cell thoroughly. Rinse the cell. You can use dish
soap or distilled white vinegar for cleaning the cell if needed. NEVER
use solvents such as acetone.
component
(Free chlorine)
AWWA
4500-cl g
eXAct®
DpD-1
Anhydrous DPD sulfate 1.5% 1.5%
Anhydrous Na2HPO433.4% 33.4%
Anhydrous KH2PO4Na264.0% 64.0%
EDTA 1.1% 1.1%
®

11
• The Pool eXact®EZ photometer has a 5 minute automatic shutdown timer.
• Each test menu can store 20 results. To retrieve the stored results, go to the desired
test using the MENU key. When the desired test is displayed, press and hold down the
MENU key. Continue holding down the MENU key to scroll the stored results for that
test, starting with the most recent result. The meter will display, from memory, the last
20 readings in sequence beginning with -20, which is the latest result, followed by -19,
which is the 2nd latest result, etc; and nally -01, which is the oldest result retained.
Only the last 20 readings are stored in each menu. This meter is able to store 100
results in memory (20 in each menu).
•
Before testing, rinse the meter sample cell with the sample water 3 times.
•
Pool water samples should be taken 18 inches below the surface. Submerge the meter
with open cell facing down 18 inches then turn meter upright at that depth to ll the cell.
Remove meter from water with the sample for testing.
• Always ll the cell to capacity (4ml); be careful not to splash liquid over the side.
• Test immediately after lling the cell with the water sample.
• To obtain optimal accuracy when testing outdoors (sunlight), use the cell cover when
zeroing and reading the sample.
• Due to the strip slitting process, you may nd one or two strips that are noticeably
smaller or larger in width than the normal strips in the bottle. These should be
discarded. Using these strips may give unreliable results.
• Meter is not compatible for use with powder pillows, tablets, or liquids from other
manufacturers.
• Dip strip for entire countdown.
• Each eXact®Strip Micro is valid for ONLY one test. Discard strip after use.
• Dry the outside of the meter before storage.
• Remove batteries before storing for prolonged periods.
• Store the meter and test materials out of direct sunlight and away from chemical
storage areas.
• Minimize exposure of meter and test reagents to heat above 90°F (32°C).
• When installing batteries, verify the O-ring is still attached to the screw before
tightening.
• Cleaning the cell with water and brush after each test is recommended for best
accuracy and prior to storage of unit.
TIPS
Issue Cause Solution
Dim screen or no Low battery Replace batteries
response from meter
Low battery Replace batteries
LO on LCD Display Dirty cell Clean cell (see pg.15)
while zeroing Cloudy sample Dilute sample or use sieve
Bad LED Contact ITS.
HI on LCD Display Result above
while reading detection level Re-run test to verify result
LO on LCD Display Result below
while reading detection level Re-run test to verify result
LO ashes on LCD Improper test procedure Re-read test procedure
Display, then Err for Combined Chlorine
and follow directions carefully
HI ashes on LCD Combined Chlorine result Re-run test to verify result
Display, then Err above detection level Dilute and re-run test
Total Chlorine result
Improper test procedure Re-read test procedure
less than Free Chlorine
and follow carefully
TrOUBleShOOTIng

12
1875 Langston Street
Rock Hill, SC 29730 USA
(800) 861-9712 | (803) 329-9712
UK Centre for Homeland Security
Building 7
Chilmark Salisbury, Wiltshire
SP3 5DU UK
+44 (0) 1722 717911
ITS Europe Ltd.
Innovators of Water Quality Testing
SENSAFE ITSSENSAFE
*Combined Chlorine DPD-3 Test requires Free Chlorine DPD-1 (486637) to be run first.
For resellers and distributors - products sold in case quantities (12 units per case).
PARAMETER/TEST
No. PART # RANGE
1
2
3
4
5
6
7
For use in accordance with
U.S. Patent No. 7,333,194,
U.S. Patent No. 7,491,546, South African Patent No. 2007/0628,
EU Patent #1,725,864, and International Patent Appln. No. PCT/US2005/033985
TESTS
eXact Pool Water Refill Kit
Alkalinity, Total
Calcium (as CaCO3)
Chlorine, Free (DPD-1)
Chlorine, Combined (DPD-3)*
Chlorine, Total (DPD-4)
Cyanuric Acid
pH
486211
486641
486629
486637
486638
486670
481652-II
486639-II
N/A
11 - 200 ppm
19 - 550 ppm
0.05 - 12 ppm
0.05 - 12 ppm
0.05 - 12 ppm
3 - 110 ppm
6.0 - 8.5
as below
100
50
100
100
100
60
100
R052814
Pool eXact®EZ Photometer Specifications
WArrAnTY
Registration of your eXact®photometer must be received within 30 days from date of
purchase to activate the warranty. Registration is available over the phone (+1-803-329-
9712 Ext. 0) or online at http://www.sensafe.com/product-registration-form/ (Personal
data is kept con dential). The eXact®photometer is warranted to be free from defects
in materials and workmanship for a period of two (2) years from the date of purchase by
the customer. ITS will repair or replace, at its discretion, product which is deemed to be
faulty due to manufacturing defect. Warranty does not cover product damage caused by
abuse (such as crushing a tablet in the cell), battery corrosion damage, or improper use.
If the meter is faulty or otherwise defective contact ITS by phone (+1-803-329-9712 Ext.
form before returning the photometer to ITS. Damage caused by improper packing of the
photometer for return shipment to ITS will not be covered by the warranty. Customer is
responsible for shipping charges to ITS. ITS pays postage when photometer is returned
to customer. A maximum processing fee of $75 will be charged for repair or replacement
of non-registered photometers and damages not covered by this warranty. The repair
or replacement of the photometer will not extend or renew the period of guarantee. This
warranty does not affect your statutory rights. The warranty is not transferable.
reOrDer
TeChnICAl SUPPOrT
Please visit www.sensafe.com/pool-ez for the latest technical
information and how-to videos.
For additional technical support, call (803) 329-9712 or send us an
email at its@sensafe.com.
R0614
Table of contents
Other Industrial Test Systems Test Equipment manuals
Popular Test Equipment manuals by other brands

Konica Minolta
Konica Minolta cm-5 instruction manual

Teledyne Lecroy
Teledyne Lecroy frontline TLF 3000 Reference manual

SIGLENT TECHNOLOGIES
SIGLENT TECHNOLOGIES SDS1104X-E user manual

Aktakom
Aktakom ACT-1210 user manual

Hanna Instruments
Hanna Instruments UPW HI 98309 instruction manual

Tektronix
Tektronix TDS5000B Series Read this first