- 1 -
Name: Ultraviolet Water Purification System
Applications: Drinking water, Rainwater from water tank, medical and industrial etc.
The SPS range is a combined filtration and UV water disinfection treatment system able to remove impurities
and safeguard your tank water supplies against bacteria, viruses and pathogens. With 4 models in the range, the
SPS-series provides safe, potable water for small, medium and large houses. It can also be used in any other water
treatment application where the combination of pre-filtration and UV water disinfection is required.
Complete Water Treatment is achieved in 3 steps
1. Coarse Filtration – Removes impurities and sediment larger than 20 microns.
2. Fine Filtration – Removes impurities and sediment over 1 micron, removes parasitic cysts like Giardia and
Cryptosporidium.
3. UV Disinfection – Inactivates pathogens, bacteria, and viruses.
Input: 110V to 220V 50/60Hz
○
1 Reactor Chamber (304SS)
○
2 Quartz Tube
○
3 O-ring
○
4 Open End Nut
○
5 UV Lamp
○
6 4-pin Electrical Socket
○
7 Screw Hole
○
8 Cover Cap
○
9 Earth Lead
○
10 Spring
- 2 -
System Installation
Step 12: When all plumbing connections are made, slowly turn on the water supply (install a flow controller if there is a
risk of high water flow rate)
Step 13: Allow the water to run a few minutes to clear any air or dust that may be in the reactor
Step 1: Open system box to make sure all components inside, installation parts list: SS reactor, UV lamp, Quartz
sleeve,ballast controller, big blue filter housing, pressure guage, O-ring & Washer.
Step 2: Open the black Knob on the side
of the frame to open the box
Step 3: use screw to open the
plastic cap
Step 5: Remove the bottom
nut
Step 6: Insert the Quartz Tube
into the Reactor Chamber.
Step 7: Hand-screw End Nut on
the Reactor Chamber.
Step 8: Screw the nuts tightly on the
reactor chamber.Firm hard tightness
is sufficient.Tools should not used
so as to avoid damaging the quartz
sleeve
Step 9: Carefully insert the Step 10: Install the cover cap and
UV Lamp into the Quartz tube screw the setscrew tighten on nut
through end nut
Step 11: use the plastic handle if you want to change the
filter carbon.
Step 4: remove the two nuts
Step 10: Install the earth wire
- 3 -
Step 14: Connect the power for start up.
Step 15: Do not remove the uv lamp from the chamber when applying the electrical power
Step 16: UV systems are designed for continuous operation and frequent switching will reduce ultra-violet radiation and
service life. Do not electrically cycle the uv unit more then 3 on/off cycles in a 24 hour period.
System Operation
a.Water Quality Guidelines
The Ultraviolet Disinfection System is intended for the use with visually clear water, not colored, cloudy or turbid.
Ambient Water Temperature: 2-45℃
Iron: <0.3ppm (0.3mg/l)
Hardness: <7gpg (120mg/l)
Turbidity: <1NTU
Manganese: 0.05ppm (0.05mg/l)
UV Transmittance: >75%
b. Recheck the installation before plug the sterilizer into power.
c. Do not proceed to install the equipment when UV Lamp or Sleeve Tube is broken, purchase a replacement and continue.
d. Ultraviolet Disinfection System is designed for continuous operation and frequent switching will reduce Ultraviolet
radiation and service life.
e. If this unit falls into the water, turn main power off and then retrieve it. Do not attempt to use this sterilizer if it has been submerged.
f. Do not operate this unit if it has a damaged cord or plug, if it is malfunctioning or if it has been dropped or been damaged in any
manner.
g. The UV system should be installed after the filter on the return line.
h. Always disconnect the water supply and completely drain the water purifier if it will be subjected to temperatures below freezing
for extended periods of time.
Important Safeguards
a.
b. UV light is not visible to human eye, but harmful to eyes and skin. Never look directly at the light tube while device is in
operation. Do not remove the UV Lamp from the Reactor Chamber when applying electrical power. Wear SAFETY GOGGLES if
you need to look necessary.
c. Basic safety precautions should always be followed to reduce the risk of fire, electric shock. Make sure the leakage protection
switch is installed before use.
d. Please do not touch the UV lamp directly in case of burning.
System Maintenance
a. Testing monthly or before each use.
b. Lamp replacement is recommended every 9000 hours of operation. After 9000 hours, the lamp may still light, but the UV intensity
has diminished.
c. Cleaning of the quartz sleeve once 3-6 months with alcohol or a mild detergent.
Warranty for uv chamber 2 years, uv lamp and quartz sleeve changer yearly
Note: To save the energy, turn off the power and water supply if you do not use the equipment for a long time.

Popular Water Filtration System manuals by other brands

Ziegra PE-3 manual

Ziegra

Ziegra PE-3 manual

Watts WQT4 RO Series Installation, operation and maintenance manual

Watts

Watts WQT4 RO Series Installation, operation and maintenance manual

PURAPOOL OXYGEN MINERALE INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

PURAPOOL

PURAPOOL OXYGEN MINERALE INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

Filtronic MG100S operating instructions

Filtronic

Filtronic MG100S operating instructions

Graco 24R707 instructions

Graco

Graco 24R707 instructions

Bluevua RO100ROPOT user manual

Bluevua

Bluevua RO100ROPOT user manual

Aqua TECHNOPOOL PH-RX manual

Aqua

Aqua TECHNOPOOL PH-RX manual

Emec LOTUS MINI Operation manual

Emec

Emec LOTUS MINI Operation manual

Hydac OLSW 20 Series Installation and maintenance instructions

Hydac

Hydac OLSW 20 Series Installation and maintenance instructions

Brita On Line Active Instructions for use

Brita

Brita On Line Active Instructions for use

Van Isle Water Clack WS1 Installation & start?up guide

Van Isle Water

Van Isle Water Clack WS1 Installation & start?up guide

SunSun HW-goa quick start guide

SunSun

SunSun HW-goa quick start guide

Graf MINIMAX Series Installation and maintenance instructions

Graf

Graf MINIMAX Series Installation and maintenance instructions

SuperFish FlowClear 20.000 manual

SuperFish

SuperFish FlowClear 20.000 manual

Grunbeck osmoliQ:LB Operation manual

Grunbeck

Grunbeck osmoliQ:LB Operation manual

Watts BB-C100 instruction sheet

Watts

Watts BB-C100 instruction sheet

AQUAPHOR APRO Series Installation and operation manual

AQUAPHOR

AQUAPHOR APRO Series Installation and operation manual

CASHIDO OH6800 Series user manual

CASHIDO

CASHIDO OH6800 Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.