INTRODUCTION
THE DELTA AEROBIC WASTEWATER
TREATMENT SYSTEM AND HOW IT WORKS
The ENVIRO-AIRE Aerobic Wastewater Treatment System that
you have purchased produces high quality effluent suitable
for various disposal methods. It is used to enhance your on-
site wastewater treatment system. You can be proud that in
purchasing your ENVIRO-AIRE System, with a minimum amount
of maintenance, you can directly contribute to a cleaner, safer
environment.
All wastewater treatment systems of this type work by using
the bacteria that nature has provided. By pumping air into
the system, the bacteria grow and thrive in much larger
amounts than would occur naturally. The increased population
of bacteria speeds up the process of treating domestic
wastewater which makes it safe to release into the environment.
This entire process takes place within the walls of your specially
designed ENVIRO-AIRE Treatment System.
Your ENVIRO-AIRE consists of three chambers contained
in one treatment system: pretreatment, aeration/mixing, and
clarifier. Domestic wastewater enters the pretreatment chamber
where solids settle out of the raw wastewater. The effluent then
flows into the aeration/mixing chamber. Mixing and aeration
are accomplished by air introduced by the aerator via the air
manifold located in this chamber. The mixed liquid then enters
the clarification chamber through an opening at the bottom of
the baffle wall. The quiet conditions in this chamber allows any
remaining solids to settle to the bottom and reenter the mixing
chamber before exiting to the drainfield. The result of this
process is a clear, odorless discharge, which meets or exceeds
state water quality standards for CBOD5and TSS.
By following the few simple steps that you find in this manual,
your ENVIRO-AIRE System will provide you with years of
service and the knowledge that you are doing your part to
protect our groundwater, lakes, rivers and streams.
HOMEOWNER CARE AND OPERATION
INSTRUCTIONS
The ENVIRO-AIRE System has been designed and built to
provide long term, reliable and efficient service. Once the unit
has been installed (see installation instructions), the unit will
operate with a minimal amount of attention.
Please reference the system’s Data Plates for serial
number that are located on the aerator, and the alarm
panel in the event that a problem arises or service is
required. Call (800) 221-4436 for your local service
provider’s contact information.
STANDARD MAINTENANCE SCHEDULE
Every 6 months for the first two years after installation,
annually after the initial 2 years. Performed by a certified
service provider.
• Inspect and make any necessary adjustments to mechanical
and electrical components.
• Inspect the air filter on the aerator. Rinse with warm water if
necessary. Do not use oil or other solvents. Allow the air filter
to dry before restarting the system.
• Inspect effluent quality’s color, turbidity, and check for odor.
An earthy odor is normal.
• Take a sample from the pretreatment treatment system and
aeration chamber to check the sludge level described in the
“Solids Removal” section below.
THE FOLLOWING ARE INDICATIONS THE
SYSTEM MAY REQUIRE SERVICE:
Warning Device
The visual and audio warning device comes on when the
power to the aerator has been interrupted, when the air supply
system has malfunctioned, or there is a high-water level in the
treatment plant. If the alarm is activated, check for a tripped
GFI, blown fuse or thrown circuit breaker. Ensure the aerator
is operating properly. Once accustomed to the soft humming
sound of a properly operating unit, any unusual noise is an
indication of malfunction. If an unusual noise is detected or total
failure is observed, call an authorized Delta service provider or
dealer/distributor.
Odors
Offensive odors may indicate the system is not functioning
properly. If such a condition should develop, call a certified
service provider or dealer/distributor.
The homeowner must be notified in writing if any improper
operation is observed and cannot be corrected at the time
of service.
TO KEEP MAINTENANCE TO A MINIMUM
AND ENSURE HIGH EFFLUENT QUALITY
THE FOLLOWING SHOULD NOT BE USED OR
DISCARDED INTO THE SYSTEM
Do not discard the following into the system:
• Greases, fats, oils.
• Pesticides, herbicides, or any other toxins.
• Paints, household chemicals, automobile fluids or mop water.
• Non-biodegradable items such as cigarette butts, rags,
feminine hygiene products, disposable diapers, condoms,
hair, bandages, coffee grounds, paper towels, plastic or
metallic objects, etc.
• Citrus products, oranges, lemons, grapefruit, etc.
• Septic system additives as they may do more harm than good.
• Hydraulic overload due to excessive water use or inflow from
other sources such as rain gutters or leaky fixtures (toilet,
sink).
• Home brewery waste, strong medicines, and antibiotics.
• Strong disinfectants, bleaches or laundry products.
• Discharge from water softeners.
• Antibacterial soaps should be avoided.
• Recommended detergents are powdered, low-sudsing, low
phosphates and biodegradable, washing soda ingredients.