Innova XTIRPA IN-8015 Instruction Manual

MU8015-002ANG 2017 P. 1
INSTRUCTION AND SAFETY MANUAL
Expandable davit arm system 762 mm - 1219 mm (30" - 48")
Xtirpa removable adaptor for PPE
MUST BE READ AND UNDERSTOOD BY THE USER BEFORE EACH USE
INNOVA Public Utility Products, Inc., 1040 BOUL. INDUSTRIEL, GRANBY, QUEBEC, CANADA
Tel (450) 777-1240 Fax (450) 372-9936 www.xtirpa.ca
™
IN-8015 UNIVERSAL RESCUE SYSTEM
Number:

MU8015-002ANG 2017 P. 1
INTRODUCTION
The XTIRPATM System was engineered for people needing a personal protection equipment system, a protection
system against falls, a work and safety positioning system to be used in isolation. The XTIRPATM System was
engineered to act as a supporting or anchoring structure for these uses. The XTIRPATM System is one of the lightest
and most ergonomic systems to use in its category on the market. The XTIRPATM System meets the ANSI, OSHA and
CSA. The equipment was tested in accordance with the applicable Type B EN 795:2012 standard’s requirements.
Always make this Instruction and Safety Manual available to any worker who needs to use the XTIRPATM System. .
Before each use, the user must read, understand and follow the manufacturer’s Instruction and Safety Manual.
Always keep the informative and safety labels affixed on the XTIRPATM System as well as those on the components
and parts clean and readable. Clean or replace if necessary. New labels can be obtained on demand.
Implement a regular training program on the use of the XTIRPATM System for all users, whether new or professional,
as recommended thereafter in this Instruction and Safety Manual. Implement a detailed inspection program for the
XTIRPATM System and document the results, as recommended below in this Instruction and Safety Manual. Always
inspect the XTIRPATM System before each use and at least one a year after that.
The XTIRPATM System, its components and parts have labels indicating each and everyone’s maximum capacity.
Exceeding this maximum capacity can not only provoke damages to the XTIRPATM System, or its components or
pieces, but can also lead to serious injury or death, for which the manufacturer refuses any warranty or responsibility,
the user, owner and buyer of the XTIRPATM System waiving any arising claim, right and remedy against the
manufacturer.
The XTIRPATM IN-8015 universal rescue system, including the components: IN-2240 or IN-2313 or IN-2426
(Mast for fall arrest and recuperation); IN-2237 (Extendable davit arm 762mm-1219mm (30'' - 48'')); A2237-06
(Removable Winch adapter for Davit arm IN-2237); IN-2380 (102mm (4'') Ajustable wall adapter 254mm à 432mm
(10''-17'')); MU8015-002ANG 2017.
CAUTION
The XTIRPATM System is part of a personal protection equipment system, a protection system against falls, a
work and safety positioning system to be used in isolation.
The user must read, understand and respect the manual’s instructions for each of the entire XTIRPATM system’s
components and parts. These instructions must be sent to the XTIRPATM System user. The manufacturer’s
instructions must be followed to ensure the appropriate use and maintenance of this product. Any modification or
misuse of the XTIRPATM System or of any of its components or parts or any failure to follow the manual’s
instructions can lead to serious injuries or death, for which the manufacturer refuses any warranty or responsibility,
the user, owner and buyer of the XTIRPATM System waiving any arising claim, right and remedy against the
manufacturer.
IMPORTANT: The buyer must imperatively complete and return the limited warranty’s record sheet.

MU8015-002ANG 2017 P. 2
DESCRIPTION AND INTERPRETATION OF
THE MARKING SYMBOLS
This symbol is used to attract the user’s attention on a potential danger. The latter’s safety
is at risk. It is essential to follow the manufacturer’s recommendations.
This symbol asks the user to read and understand this product’s operation manual before us-
ing it.
This symbol indicates that the system must be used by one user only.
The anchorages must be installed by a qualified and experienced staff, according to local legis-
lations, manufacturers' recommendations on anchorages must be followed at all times.
Inspect the installation as well as the adaptor's status at regular intervals or when the system
experienced a fall. In the event of a fall or of any doubt regarding the equipment's integrity,
the latter must immediately be withdrawn and inspected by a qualified person before any re-
use.
Maximum allowable arrest force.
During manoeuvres and in order to avoid any serious injury, the positioning pin must
be in place.
Adaptors are designed for XTIRPA(TM) equipments only or approved by the latter.
The manufacturer meets ISO-9001 and ISO-17025 requirements.

MU8015-002ANG 2017 P. 3
-1-
APPLICATION
The XTIRPATM System as well as its numerous components and parts (including the davit arm, safety guard,
removable adapter, permanent adapter, integrated mast and side entrance trolley) were engineered to be used as part
of a personal protection equipment system, a protection system against falls, a work and safety positioning system,
a staff management system, an equipment management system and a safeguard system to be used in isolation. The
XTIRPATM System was engineered to act as a supporting or anchoring structure for these uses. .
-2-
RESTRICTIONS
a) CAPACITY : This product’s maximum workload is 360 lbs (164 kg). Per (ANSI, OSHA, CSA).
b) The manufacturer confirms that the anchoring devices were subjected to tests in accordance with the
current European standard (EN 795: 2012 Type B) and that, unless otherwise indicated, they are
suitable for use by one person only with a shock absorber compliant with EN 355.
c) PRECAUTIONS : Take the necessary precautions to limit the user’s injuries and the XTIRPATM
System’s risks of damage.
d) Using the XTIRPATM System in hazardous environments may required additional precautions to limit
the possibility of injuries to the user or damages to the XTIRPATM System. Hazards may include but
are not limited to: high temperatures, fire, flames, fumes, caustic chemical products, corrosive
environments, high voltage electrical cables, sudden pressure changes, gas or toxic or explosive
substances, water or risks of flooding, risk of wall, ceiling or floor collapsing, mobile machinery and
sharp-edged items.
e) Install and secure all marking and other precaution and safety measures, including without limitation,
those informing users, bystanders and vehicle operators circulating near the XTIRPATM System of the
presence of the XTIRPATM System and workers before starting the works.

MU8015-002ANG 2017 P. 4
f) Wear any appropriate, certified and recommended safety equipment, including, without limitation,
safety helmet, protective glasses, leather gloves, protective clothing, safety boots, harness compliant
with EN 361, flashlight and respiratory system if necessary.
g) Always work in team composed of at least two (2) people: 1 agent and 1 worker in a closed space
(the person attached to the cable or lifeline) who must be qualified and trained in using the XTIRPATM
System and who must have read and understood the Instruction and Safety Manual before using the
XTIRPATM System. One person works inside the enclosed space (the person attached to the cable or
lifeline) and the other (the agent) is in charge of handling the lifeline and rewind, keeping contact with
the person located inside and remaining available in case of emergency. The agent ensures that, at all
times, the user who attaches his/her cable or lifeline to his/her harness compliant with EN 361 is in the
right position. The agent also ensures that the XTIRPATM System is firmly in place and that no load
imbalance can happen.
h) Only use a full body harness compliant with EN 361 as well as certified cable and lifelines for every
XTIRPATM System’s user, with appropriate specifications that were engineered and recommended for
use in specialized working conditions, such as those for which the XTIRPATM System was engineered,
as indicated in this Instruction and Safety Manual. Pour l’installation des câbles ou ligne de vie sur les
points d’ancrages certifiés 12kN de la potence, voir section 6 paragraphe 3 à 5.
i) Plan your work before starting the works. One must have the required and available equipment,
procedures and workers to perform the work and the latter must be qualified and trained in using the
XTIRPATM System and must have read and understood this Instruction and Safety Manual before using
the XTIRPATM System.
j) Always keep the informative and safety labels affixed on the XTIRPATM System as well as those on the
components and parts clean and readable. Clean or replace if necessary. New labels can be obtained on
demand.
k) Do not exceed 360 lbs. (164 kg) (CSA, ANSI, OSHA) or the system’s maximum working load.
l) Follow all the laws, regulations and standards that rule the work, entrance and exit in a closed space.
CAUTION: It is agreed and accepted that the use of the equipment (system) is limited to one person only.
CAUTION: Any alteration or addition to the equipment cannot be performed without the manufacturer’s
prior written consent and any repair must be performed in accordance with the manufacturer’s method of
operation. .
CAUTION: The equipment must only be used by trained and competent people in order for this product
to be used safely.
CAUTION: The equipment must not be used beyond its limits or for purposes other than those for which
it was originally intended.
IMPORTANT: If the anchoring device’s marking cannot be accessed after the use, an additional marking
located near the anchoring device is recommended.
IMPORTANT: During the system installation, it is important to ensure its stability.
IMPORTANT: When used as a PPE, the system must be equipped with an equipment limited the
dynamic forces that were exerted by the user to a maximum of 6 kN (1320 LbF).

MU8015-002ANG 2017 P. 5
m) Any person who hasn’t read this Instruction and Safety Manual, who hasn’t been trained in using the
XTIRPATM System and who does not understand all the instructions related to the operation, security,
maintenance, repair, and storage contained in this Instruction and Safety Manual and in any other
recommendation provided by the manufacturer or his qualified trainers, is not qualified to operate the
XTIRPATM System and does it at his/her own risks and, doing so, waives all arising claims, rights
and remedy against the Manufacturer.
n) Make sure to respect the requirements related to the anchoring device (such as the floor adapter, wall
adapter, recessed wall, etc.) or to the structure chosen to serve as an anchoring point, and in particular,
the minimum required resistance, adequacy and position.
o) The maximum force applied by the system on the structure is, a vertical force of 22 kN (5000 lbf),
per CSA, ANSI, OSHA or 12kN per EN362, EN795 on the anchorage to which the system
is fixed.
p) A safety plan must be established in order to face any emergency that could arise during work.
CAUTION: Anchoring devices must only be installed by competent people or organization.
CAUTION: Any alteration or addition to the equipment cannot be performed without the
manufacturer’s prior written consent and any repair must be performed in accordance with the
manufacturer’s method of operation.
CAUTION: It is agreed and accepted that the use of the equipment (system) is limited to one
person only.
CAUTION: The XTIRPA™ System must be placed on a hard and leveled surface. Do not use the
XTIRPA™ System on a soft ground, such as, but not limited to sand, grass, gravel and pebbles. If
you have questions related to the use, maintenance or adequacy of the XTIRPATM System for your
application, please contact the PSP INNOVA INC. Manufacturer.
CAUTION: Installation must be checked appropriately, for example, through calculations or tests.
CAUTION: The fitness for use of the base materials’, structural anchor’s or fastening component,
if any, must be considered by taking into account the loads registered on the anchoring device during
the dynamic resistance and integrity tests.
CAUTION: To ensure security during the use of the fall arrest system, it is essential to make sure that
there is enough clearance below the user, so as to avoid any injury. If any fall were to occur, there
should be enough clearance to avoid a collision between the ground and any other obstacle. See the
diagram of the air draft calculation in section 8.

MU8015-002ANG 2017 P. 6
-3-
XTIRPATM SYSTEM REQUIREMENTS
a) The XTIRPATM System was engineered to be used as part of a personal protection equipment
system, a protection system against falls, a work and safety positioning system, a staff management
system, an equipment management system and a safeguard system to be used in isolation. The
XTIRPATM System was engineered to act as a supporting or anchoring structure for these uses.
The XTIRPATM System must only be used with adaptors, anchorages, connectors (EN 362),
other components, parts or sub-systems that are certified, approved and recommended by the
manufacturer.
b) Substitutes or replacements created with adaptors, anchorages, connectors (EN 362), other
components, parts, or subsystems may not be compatible, may jeopardize the safety and reliability
of the XTIRPATM System assembly, and may cause serious injury or death, for which
the Manufacturer waives any and all warranty or responsibility, the user, owner, and buyer
of the XTIRPATM System renouncing to any arising claims, rights, and remedies against
the Manufacturer
c) The connector (EN 362) (hooks, snap hooks, D rings) must be able to withstand a weight
of at least 5,000 lbs (2,273 kg) (CSA, ANSI, OSHA)
d) Ensure that the cable or lifeline is directly placed above the working area. Only use cables or
lifelines that are certified and in perfect functioning state, with the appropriate specifications,
including the maximum lifting capacities for the XTIRPATM System’s intended use .
e) The owners must ensure that, before each use, any users of the XTIRPATM System users have read,
understood, and will follow the Manufacturer's Instruction and Safety Manual.
f) The owners must also ensure that all users were trained to use the XTIRPATM System before
allowing them to use the XTIRPATM System, as well as at least once a year thereafter.
IMPORTANT: In the event that the handling/positioning winch is required, this option is offered to you
with the addition of an adaptor located at the bottom of the davit arm. You will have to repeat steps 10-
11-12 for the installation of the lifeline/winch. Should you have any questions concerning the use, main-
tenance or appropriateness of the XTIRPATM System for your application, please contact the PSP IN-
NOVA INC. Manufacturer.
IMPORTANT : If you have questions related to the use, maintenance or adequacy of the XTIRPATM
System for your application, please contact the PSP INNOVA INC. Manufacturer.
IMPORTANT : Enter the product’s ID number indicated on the ID label on the maintenance and
inspection sheet contained in this Instruction and Safety Manual.
IMPORTANT: Enter the date of purchase as well as the date of the first use on the maintenance and
inspection sheet contained in this Instruction and Safety Manual.
CAUTION: It is imperative to never use this system both with staff and for hanling equipment purposes.

MU8015-002ANG 2017 P. 7
g) A person who hasn’t read the Instruction and Safety Manual, who hasn’t been trained to use the
XTIRPATM System and who doesn’t understand all the operation and safety instructions, is not
qualified to use the XTIRPATM System. A user who wasn’t trained exposes others and himself/
herself to serious injuries or death, for which the manufacturer refuses any warranty or
responsibility, the user, owner and buyer of the XTIRPATM System waiving any arising claim,
right and remedy against the manufacturer.
h) Refer to and follow all the ANSI, OSHA and CSA standards as well as other local standards and
regulations. Follow all requirements of your local regulations concerning your applications .
i) See the other important operating and safety instructions contained below in this Instruction and
Safety Manual.
j) Enough information must be given to ensure the compatibility of the equipment’s various items
when they are assembled into a system.
k) The service life of XTIRPATM System, and of its components, will be determined following the
conclusions of periodic and monthly verifications which determine if the product shall remain in
service or not until the system’s decommissioning.
CAUTION: Any person suffering from medical conditions that may affect the user’s safety during the
normal use of the equipment and in case of emergency must refrain from using the system.
CAUTION: It is essential for the user’s safety, if the product is resold outside the first destination
country, that the reseller provides the user guide, instructions for maintenance, for periodic exams, as
well as instructions for repairs, in the language of the country where the product is being used. It is also
important to provide any required additional information that is specific to the equipment.
CAUTION: A danger may occur during the use of several items in which the safety feature of one of
the items is affected by or interferes with the safety feature of another item.
CAUTION: If it was used to stop a fall, it should no longer be used until a qualified person authorizes
its reuse in writing.
WARNING: The user’s safety is directly associated to the efficiency of the equipment’s maintenance
and integrity.

MU8015-002ANG 2017 P. 8
-4-
MAINTENANCE/REPAIRS/STORAGE
a) Before each use, the user must read, understand and follow the manufacturer’s Instruction and Safety
Manual. Ensure that markings are visible at all times.
b) Before each use, inspect carefully the XTIRPATM System as well as all its components and parts. Any
faulty part or component could lead to serious injury or even death.
c) The ANSI, OSHA and CSA standards require a regular inspection program for any entrance/
recuperation equipment in closed space, as well as keeping the documented results of these
inspections up to date. Use the maintenance and inspection sheets included in this Instruction and
Safety Manual to document your results.
d) It is recommended to mark the next or latest inspection date on the anchoring device.
e) Decommission the XTIRPATM System if a problem, a non secure or faulty condition is discovered
during the inspection. Return to an authorized service center or to the manufacturer for repair.
f) The replacement of components and parts, as well as any additional service and repair must be
performed by an authorized service center that was approved by the manufacturer or by the
manufacturer himself.
g) If the adjustable supporting legs of the expandable coupling system for XTIRPATM vehicles and
counterbalanced forklifts do not move freely, you must lubricate them with a light machine oil.
h) Establish a yearly inspection procedure which will be performed by a competent person (someone
who is familiar with, was trained and has read and understood this Instruction and Safety Manual
completely) other than the user.
i) Clean the XTIRPATM System periodically with water and a mild detergent. Clean labels when
necessary.
j) During the descent of removable systems, it is important to place them softly on the ground in order
to avoid not to damage the components.
k) Store the XTIRPATM System in a dry and clean area, protected from direct sunlight. Avoid places
with fumes, chemical or toxic substances or environments. Do not immerse or leave in direct contact
with water since this could lead to corrosion and rust. Inspect the XTIRPATM System after every
prolonged storage period and at least once a month.
l) The XTIRPATM System was engineered to last more than 10 years in continuous service. However
the service life of XTIRPATM System, and of its components, will be determined following the
conclusions of periodic and monthly verifications which determine if the product shall remain in
service or not until the system’s decommissioning.
m) Each component of the XTIRPATM System should be stored in an individual bag to facilitate
transport and handling.
CAUTION: a periodic exam must be performed at least once every twelve months.

MU8015-002ANG 2017 P. 9
IMPORTANT: The buyer must imperatively complete and return the limited warranty’s record sheet for
each product.
WARRANTY
The XTIRPATM System, offered by the PSP INNOVA INC. Manufacturer, is warranted against all
defects in material and labor for a (2) two-year period from the date of purchase, this warranty does not
protect the XTIRPATM System’s initial buyer. The Manufacturer will promptly repair or replace all the
components or parts that he deemed faulty, the Manufacturer reserves the right to ask for the allegedly
faulty part to be return to his factory, before performing any repair or replacement.
Only the components and parts that were deemed faulty by the Manufacturer, at his sole discretion and
following any required inspection performed by the Manufacturer, will either be repaired or replaced by
the Manufacturer, whichever he chooses to perform.
Any claim must be sent in writing to the Manufacturer immediately after the owner discovered the
problem and must be accompanied by a copy of the initial buyer’s proof of purchase. The Manufacturer
will issue a complain number and will provide specific instructions related to the complains procedures
and the return of the faulty part that will have to be followed, if required by the Manufacturer. The owner
will be collaborate with the Manufacturer and his representatives in order to allow for the inspection of
every part allegedly faulty. All the incurred transport costs associated to the return of the faulty
components and parts to the Manufacturer’s factory must be paid by the owner, as the transport fees to
associated to the return of the replacement components and parts will be covered by the Manufacturer.
This warranty does not cover any damage to the equipment resulting from any cause other than a defect
in manufacturing and labor, including without limitation, any damage resulting from any abuse, lack of
maintenance, inadequate handling or storage, intentional damage, vandalism, accidental damage or
damage resulting from an impact or a collision, damage during transport, damage caused by fire, by an
explosion, by vapors, chemical, toxic or corrosive substances or environments, water, normal corrosion
and rust, storms, hail and any act of God, war, insurrection, terrorist act or any other damage beyond the
reasonable control of the Manufacturer. This warranty only applies to the initial buyer and is the only
applicable warranty of the XTIRPATM System instead of any other warranty, either express or implied.
Without limiting the generality of the foregoing, the Manufacturer will not be responsible for any costs,
damages or claims, including any special, accidental, indirect, or consequential damages, including but
not limited to any loss of revenue or anticipated profits, business interruption, personal injury, failure to
comply with any obligation, done in good faith or any neglect or default in good faith, any financial loss
or any other loss, arising from or related in any way to the use or impossibility to use the XTIRPATM
System, even in case of a fault, of a wrongdoing (including negligence), of a strict liability, of a breach
or contract or breach of warranty, and even if the Manufacturer was informed of the possibility of such
damages. The Manufacturer declines any other warranty and condition, either express, implied or
statutory, including, but not limited to, any warranty or condition of merchantability, fitness for
particular use or application and for lack of negligence or professional diligence.

MU8015-002ANG 2017 P. 10
-5-
DESCRIPTION OF THE XTIRPATM SYSTEM
DESCRIPTIONS
(See illustrations on the next page)
EXTENDABLE DAVIT ARM 762MM-1219MM (30'' - 48''): IN-2237 (see illustration 1)
MAST FOR DAVIT ARM 30'' TO 48'' 500MM (19.7) HIGH: IN-2426 (see illustration 2)
102MM (4'') MAST FOR DAVIT-ARM IN-2237 1067MM (42'') HEIGHT: IN-2240 (see illustration 3)
102MM (4'') MAST FOR DAVIT-ARM IN-2237 1524MM (60'') HEIGHT: IN-2313 (see illustration 4)
102MM (4'') AJUSTABLE WALL ADAPTER 254MM À 432MM (10''-17''): IN-2380 (see illustration 5)
REMOVABLE WINCH ADAPTER FOR DAVIT ARM IN-2237: A2237-06 (see illustration 6).
EXPANDABLE DAVIT ARM SYSTEM 762 MM - 1219 MM (30" - 48") XTIRPA REMOVABLE
ADAPTOR FOR PPE: IN-8015 (see illustration 7).
CAUTION
The XTIRPATM System is part of a personal protection equipment system, a protection system against
falls, a work and safety positioning system, a staff management system, an equipment management
system and a safeguard system to be used in isolation. The XTIRPATM System was engineered to
act as a supporting or anchoring structure for these uses. The user must read, understand and respect
the manual’s instructions for each of the entire XTIRPATM system’s components and parts. These
instructions must be communicated to the XTIRPATM System user. The manufacturer’s instructions
must be followed to ensure the appropriate use and maintenance of this product. Any modification
or misuse of the XTIRPATM System or of any of its components or parts or any failure to follow the
manual’s instructions can lead to serious injuries or death, for which the manufacturer refuses any
warranty or responsibility, the user, owner and buyer of the XTIRPATM System waiving any arising
claim, right and remedy against the manufacturer.

MU8015-002ANG 2017 P. 11
Illustration 2: IN-2426
Illustration 1: IN-2237
Illustration 4: IN-2313
Illustration 3: IN-2240
Illustration 5: IN-2380 Illustration 6: A2237-06
Illustration 7: IN-8015

MU8015-002ANG 2017 P. 12
MAST IN-2240 or IN-2313 or IN-2426
Extendable davit arm 762mm-1219mm (30'' - 48'') with the
support amovible pour treuil de potence IN-2237
102mm (4'') Ajustable wall adapter 254mm à 432mm (10''-17'')
IMPORTANT : If you have questions related to the use, maintenance or adequacy of the XTIRPATM
System for your application, please contact the PSP INNOVA INC. Manufacturer.
IMPORTANT : Enter the product’s ID number indicated on the ID label on the maintenance of the
XTIRPATM System and inspection sheet contained in this Instruction and Safety Manual.
CAUTION: The XTIRPATM System is part of a personal protection equipment system, a protection
system against falls, a work and safety positioning system, a staff management system, an equipment
management system and a safeguard system to be used in isolation. The XTIRPATM System was
engineered to act as a supporting or anchoring structure for these uses. The user must read, understand
and respect the manual’s instructions.
CAUTION: These instructions must be communicated to the XTIRPATM System user. The
manufacturer’s instructions must be followed to ensure the appropriate use and maintenance of these
products. Any modification or misuse of the XTIRPATM System or of any of its components or parts or
any failure to follow the manual’s instructions can lead to serious injuries or death, for which the
manufacturer refuses any warranty or responsibility, the user, owner and buyer of the XTIRPATM
System waiving any arising claim, right and remedy against the manufacturer.

MU8015-002ANG 2017 P. 13
3.
A. Insert the mast into the ajustable wall
adaptor’s receptacle.
B. Lock using the pin.
4.
A. Install the davit arm’s receptacle on the
mast.
B. Lock using the pin.
1. Ensure that all components
and parts are in perfect operating
condition and that everything works
properly.
2.
A. Remove the retention pins. Adjust both parts
of the adaptor to get a distance that is barely
greater than the low wall on which it is
installed. Replace the retention pins making
sure that the marble is visible from the other
side.
B. Install the adaptor onto the low wall and
tighten the 8 bolts so that they all come into
contact with the low wall.
IN-2237
IN-2380
IN-2240
SYSTEM’S OPERATION AND USE Davit arm with mast and barrel adaptor

MU8015-002ANG 2017 P. 14
7.
A. Remove the retaining pin. Pass the
cable or lifeline or winch cord through
one of the pulleys located at the end of
the davit arm. Ensure that the cable or
cord was passed through safely and is
firmly in place.
B. Replace the retaining pin.
8.
A. Remove the locking pin from its location at the
center of the davit arm.
B. Extend the davit arm to the desired length and
lock using the pin.
IMPORTANT: In the event that a handling/positioning winch is required, this option is offered to you
with the addition of an adaptor located at the bottom of the davit arm. Steps 6-7-8 to install the lifeline/
winch will have to be repeated. If you have questions related to the use, maintenance or adequacy of
the XTIRPATM System for your application, please contact the PSP INNOVA INC. Manufacturer.
To install a second handling winch or lifeline, follow the following steps using the
removable bracket for the A2237-06 handling winch
6. Install the lifeline or winch onto the davit arm
support designed to receive this type of equipment.
Use the locking pin provided along with the lifeline
or winch support and lock with the latter.

MU8015-002ANG 2017 P. 15
CAUTION: It should be noted that only the plates, supports and adaptors that were certified, approved and
recommended by the manufacturer can be used.
IMPORTANT: Ensure that the cable or lifeline is directly placed above the working area. Only use cables or
lifelines that are certified and in perfect functioning state, with the appropriate specifications, including the
maximum lifting capacities for the XTIRPATM System’s intended use.
CAUTION: The XTIRPA™ System must be placed on a hard and leveled surface. Do not use the XTIRPA™
System on a soft ground, such as, but not limited to sand, grass, gravel and pebbles. If you have questions related
to the use, maintenance or adequacy of the XTIRPATM System for your application, please contact the PSP
INNOVA INC. Manufacturer
IMPORTANT: If necessary, use a safety guard to secure the work space to avoid any falls.
CAUTION: Any system must immediately be removed from circulation: if the security is questioned or if it was
used to stop a fall. It is imperative to immediately stop using the system until a competent person authorizes in
writing the product’s integrity before it can be used again.
CAUTION: In the case of fall arrest systems and to ensure the user’s safety, the anchoring device or anchorage
point must always be placed correctly and the work must be performed in a way that reduces the risk of falls as
well as the height of falls. The anchoring device or anchorage point must imperatively be placed above the user’s
position.
CAUTION: With the use of a fall arrest system and to ensure safety, please check the clearance below the user in
the work place before every possible use, so that in case of a fall, no collision with the ground can occur and no
obstacle can be found on the trajectory.
IMPORTANT: A certified fall arrest harnessis the only body harness device that can be used in a fall arrest
system.
IMPORTANT: The fall arrest harness must be fastened to the system’s cable or lifeline by the fall arrest
suspension point of the harness.
CAUTION: The instruction and safety manual must be followed to ensure the appropriate use and maintenance of
this product. Any modification or misuse of the XTIRPATM System or of any of its components or parts or any
failure to follow the manual’s instructions can lead to serious injuries or death, for which the manufacturer refuses
any warranty or responsibility, the user, owner and buyer of the XTIRPATM System waiving any arising claim,
right and remedy against the manufacturer.

MU8015-002ANG 2017 P. 16
-7-
THE FOLLOWING INFORMATIVE AND
SAFETY LABELS MUST BE CLEAN AND
READABLE AT ALL TIMES
INSTRUCTION LABEL IN-2237 INSTRUCTION LABEL IN-2240 INSTRUCTION LABEL IN-2313

MU8015-002ANG 2017 P. 17
INSTRUCTION LABEL
IN-2237
INSTRUCTION LABEL
IN-2380
INSTRUCTION LABEL IN-2426

MU8015-002ANG 2017 P. 18
-8-
Calculation diagram

MU8015-002ANG 2017 P. 19
Other manuals for XTIRPA IN-8015
1
Table of contents