1 FUNCTION
The detector is designed to detect intrusion into the
protected area, generate an alarm notification and
transmit via radio to the receiver Astra-812 Pro, Astra-
WE 433 or Security hub.
The detector is insensitive to pets of up to 20 kg
weight.
The detector provides measurement and transmission
via radio (at intervals of 12 sec.) of the following
parameters:
a) residual capacity of the battery with display in the
event log when the values of 30, 20, 10% are reached;
b) ambient temperature.
2 DETECTION ZONE
3 SPECIFICATIONS
Range of detectable
moving speed, m/sec ............................. from 0.3 to 3.0
Wireless coverage range (line-of-sight), m..............300
Operating frequency range, MHz.............................433
Power supply voltage, V......................... from 2.2 to 3.0
Overall dimensions, mm............................ 70 × 51 × 42
Operating Conditions
Temperature range, °С.......................from - 10 to + 50
Relative air humidity, %.........................up to 98 at + 40 °С
without moisture condensation
4 DELIVERY SET
Detector delivery set includes: dowel –2 pcs., screw –
2 pcs., battery (CR123A, 3 V) - 1 pc. (installed), jump-
ers –2 pcs. (installed), user guide –1 copy.
5 MODES OF OPERATION
Setting an operating mode of the detector and
indication of notifications is possible within 10
minutes after battery insertion!
Mode
Plug
Jumper
Mode 2* (compatible with
Security Hub)
Mode 1
Rmod
Frequency1 (433,42МГц)*
(compatible with Security Hub)
Frequency3(434,42МГц)
Lit
*factory setting
6 REGISTRATION
ATTENTION!
When registering, the operating mode of the radio and
the operating frequency of the detector and the wireless
network must match.
1) Create a wireless network in accordance with the
Manual for configuring the receiver.
2) Open detector’s cover.
3) Use the jumpers to set the required radio operation
mode and the operating frequency of the detector in
accordance with the wireless network parameters.
4) Start registration procedure on the receiver according
the Manual. Registration starts for 45-60 sec.
5) Activate the battery by pulling out the protective
strip or re-install the battery.
In case of unsuccessful registration, remove the
battery and repeat procedure. Before installing it on
again, wait at least 20 sec. or briefly set the battery in
reverse polarity.
6) Make sure that the registration is successful ac-
cording the Manual.
7INSTALLATION PLACE
1) Recommended installation height is 2.25-2.35 m.
2) Install the detector on bearing walls and
carriers.
3) The detector must be installed strictly
vertical, without tilting forward.
To eliminate false alarms
1) It is recommended to close all doors,
air-vents, switch off fans, air-conditioners and other
sources of intense air flows in the room during
protection period.
2) Any furniture or interior items within 3 m of the
detector which could make possible for an animal to
climb above the floor level must be removed.
Not recommended installation places
8 INSTALLATION PROCEDURE
1) Remove cover
2) Remove PCB
3a) Installation
on the wall
3b)Installation
in the corner
ATTENTION! Fix the detector base on a hard surface
to safely break out the caps. Orient the detector base
strictly according to the drawing!
4) Seal all holes in the base with sealing material.
5) Place the PCB.
6) Perform TEST-pass (see p.9).
9 TEST-PASS
1) Power on the detector. LED will flash 1 time in 2
sec. for not more than 60 sec.
2) Close the cover of the detector.
3) After the detector enters the
standby mode, perform a TEST-
pass of the protected area at a
speed of 0.3 m / sec to
determine the sensitivity zone.
At the moment of detection (the
LED will light up for 1 sec), stop,
mark this position, then go back two steps and
continue moving. Repeat the TEST-pass in the
opposite direction.
4) Check the operability of the detector:
- perform TEST-pass,
- control:
• on the led of the detector - issuance of the indication
"Alarm" (1-time flash);
• receiving the notification “Alarm”on the receiver.
10 WARRANTY
The operation warranty period is 5 years from the date
of operation start-up but no longer than 5 years 6
months from the date of manufacturing subject to the
requirements of current User guide.

Other teko Security Sensor manuals

teko Astra-361 Installation instructions

teko

teko Astra-361 Installation instructions

teko Astra-517 ver.P User manual

teko

teko Astra-517 ver.P User manual

teko Astra-612 User manual

teko

teko Astra-612 User manual

teko Astra-GB User manual

teko

teko Astra-GB User manual

teko Astra-621 User manual

teko

teko Astra-621 User manual

teko Astra-516 User manual

teko

teko Astra-516 User manual

teko Astra-5131 User manual

teko

teko Astra-5131 User manual

teko Astra-517 User manual

teko

teko Astra-517 User manual

teko Astra-531 AC Installation instructions

teko

teko Astra-531 AC Installation instructions

teko Astra-361 User manual

teko

teko Astra-361 User manual

teko Astra-MA User manual

teko

teko Astra-MA User manual

teko Astra-Z-3645 User manual

teko

teko Astra-Z-3645 User manual

teko Astra-621 RF User manual

teko

teko Astra-621 RF User manual

teko Astra-551 User manual

teko

teko Astra-551 User manual

teko Astra-531 Ver.PIR User manual

teko

teko Astra-531 Ver.PIR User manual

teko Astra-9 User manual

teko

teko Astra-9 User manual

teko Astra-531 PIR Installation instructions

teko

teko Astra-531 PIR Installation instructions

teko Astra-8 User manual

teko

teko Astra-8 User manual

teko Astra-515 ver.A User manual

teko

teko Astra-515 ver.A User manual

teko User guide User manual

teko

teko User guide User manual

teko Astra-531 DC Installation instructions

teko

teko Astra-531 DC Installation instructions

teko Astra-5 ver.A User manual

teko

teko Astra-5 ver.A User manual

teko Astra-431 User manual

teko

teko Astra-431 User manual

teko Astra-551 User manual

teko

teko Astra-551 User manual

Popular Security Sensor manuals by other brands

HD Electric V-WATCH Operating instructions manual

HD Electric

HD Electric V-WATCH Operating instructions manual

GasTech D-GUARD2R instruction manual

GasTech

GasTech D-GUARD2R instruction manual

Hytronik HIR23 Installation and instruction manual

Hytronik

Hytronik HIR23 Installation and instruction manual

AVS Electronics JET DT manual

AVS Electronics

AVS Electronics JET DT manual

GE 250-CO Installation sheet

GE

GE 250-CO Installation sheet

Chamberlain 801CB-P installation manual

Chamberlain

Chamberlain 801CB-P installation manual

Dionex UVD 170S operating instructions

Dionex

Dionex UVD 170S operating instructions

ZIGBEE ENVILAR ZG102-BOX-UNIDIM manual

ZIGBEE

ZIGBEE ENVILAR ZG102-BOX-UNIDIM manual

Interlogix SB Series installation manual

Interlogix

Interlogix SB Series installation manual

TS-market LORNET-24 user manual

TS-market

TS-market LORNET-24 user manual

PeakTech 1030 Operation manual

PeakTech

PeakTech 1030 Operation manual

Knauer Axura DAD 6.1L user manual

Knauer

Knauer Axura DAD 6.1L user manual

HOGERT HT4M341 user manual

HOGERT

HOGERT HT4M341 user manual

Teledata SF1000E quick start guide

Teledata

Teledata SF1000E quick start guide

LMI Technologies EyeCon 2 0 Series user manual

LMI Technologies

LMI Technologies EyeCon 2 0 Series user manual

Huazheng HZJF-9011D user manual

Huazheng

Huazheng HZJF-9011D user manual

Family Safety Products Siren Pro Series 3 HS71512 manual

Family Safety Products

Family Safety Products Siren Pro Series 3 HS71512 manual

Feig Electronic VEK MNE1-R24-A operating instructions

Feig Electronic

Feig Electronic VEK MNE1-R24-A operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.