innovair SLIM24 Installation instructions

=· '\
Installation and
Owner's Manual
WIRED CONTROLLER
j',
IMPORTANT NOTE:
SLIM24

This manual gives detailed description of the precautions
that should be brought to your attention during operation.
In order to ensure correct service of the wired controller
please read this manual carefully before using the unit.
For convenience of future reference, keep this manual
after reading it.
All the pictures in this manual are for explanation purpose
only. There may be slightly dierent from the wired remote
controller you purchased (depend on model). The actual
shape shall prevail.

1. Safety precaution
2. Installation accessory
3. Installation method
4. Specification
5. Feature and function of the wired controller
6. Name on the LCD of the wired controller
7. Name of buttonson the wired controller
8. Preparatory operation
9. Operation
10. Timer functions
11. Weekly Timer 1
12. Weekly Timer 2
13. Fault alarm handing
14.Technical indication and requirement
15.Queries and settings
16. Wireless control connection
..........................................................1
................................................... 2
........................................................4
................................................................12
................13
.....................14
......................15
.................................................16
....................................................................17
...........................................................28
..........................................................31
.........................................................37
..................................................44
........................44
..................................................45
.......................................50
Table of Contents

1
1. Safety precaution
Do not uninstall the unit randomly.
Random uninstalling may lead to abnormal operation,
heating or fire of the unit.
WARNING
Please entrust the distributor or professionals to install the unit.
Installation by other persons may lead to imperfect installation,
electric shock or re.
Adhere to this installation manual.
Imporper installation may lead to electric shock or re.
Reinstallation must be performed by professionals.
•
•
•
•
•
NOTE
•
•
Do not install the unit in a place vulnerable to leakage of
flammable gases. Once flammable gases are leaked and left
around the wire controller, fire may occure.
Do not operate with wet hands or let water enter the wire
controller. Otherwise, electric shock may occur.
The wiring should adapt to the wire controller current.
Otherwise, electric leakage or heating may occur and result in
re.
•

1. Safety precaution
NOTE
The specified cables shall be applied in the wiring. No external force
may be applied to the terminal. Otherwise, wire cut and heating may
occur and result in fire.
•
2. Installation accessory
Select the installation location
Don’t install where there is a presence of heavy oil, vapor or
sulfureted gas. Otherwise, this product would be deformed, and
it could lead to a system malfunction.
Preparation before installation
1. Please verify that all the following parts have been supply.
1
2
3
4
5
3
2
M3.9*25 (For Mounting on the Wall)
M4X25 (For Mounting on switch box)
6
7
8
3
2
No. Name Qty. Remarks
Wire controller
Installation and owner’s manual
For Mounting on the Wall
Plastic screw bars
Screws
Wall plugs
For fixing on switch box
Optional
Screws
9Screw
1
1
Battery
The connective wires group
1
1
1
M4X8 (For Mounting the connective wire group)
2

3
2. Installation accessory
Precaution of installing the wire controller
1. This manual provides the installation method of wired
controller. Please refer to the wiring diagram of this installation
manual to connect the wire controller with indoor unit.
2. The wired controller works in low voltage loop circuit. For to
directly contact the cable of high voltage above, like
115V,220V,380V, and don’t wire this kind of wire in the said
loop; wiring clearance between configured tubes should be at
the range of 300~500 mm or above.
3. The shielded wire of the wired controller must be grounded
firmly.
4. Upon finish the wire controller connection, do not employed
tramegger to detect the insulation.
2. Prepare the following assemblies on the site.
1
2
1
Switch box
Wiring Tube (Insulating
Sleeve and Tightening
Screw)
Qty.(embeded
into wall)
No. Name Remarks
Specication
(only for reference)
1

4
3. Installation method
Fig 3-1
1.Wired remote controller structural dimensions
2.Remove the upper part of wired controller
Insert a slot screwdriver into the
slots in the lower part of the wired
controller (2 places), and remove
the upper part of the wire controller.
(Fig.3-2)
19mm84mm
46mm
60mm
44mm
120mm
120mm
Back cover
NOTE: Do not pry up and down, you can only rotate the screwdriver.
20.6mm
Buckling
position
(Fig.3-2)

5
3. Installation method
Fig 3-4
For exposed mounting, fasten the back plate on the wall with the
3 screws (M3.9*25) and plugs. (Fig.3-3)
Fig 3-3
Use two M4X25 screws to install the back cover on the 86 switch box,
and use one M3.9*25 screw to fix to the wall.
3. Fasten the back plate of the wired controller
Back plate
Screws (M3.9*25)
Screw hole fixed on the wall, useone M3.9*25mm
Screw hole installed on 86 switch box, use two M4X25mm
NOTE: The PCB is mounted in the upper part of the wired
controller. Be careful not to damage the board with the
slot screwdriver.

6
3. Installation method
Fig 3-5
Put the battery into the designated spot and make sure the positive
side of the battery is in accordance with the positive side. (See
Fig.3-5)
Please set the correct time on the first-time operation. Battery in the
wire controller can operate when a power failure occurs which
ensure the time is kept right. When the power restores, if the time
displayed is not correct, it means the battery is dead and should be
replaced.
4. Battery installation
NOTE: Put on a at surface. Be careful not to distort the
back plate of the wire controller by overtightening the
mounting screws.

7
3. Installation method
Fig 3-6
5. Wire with the indoor unit
44mm
60mm
Wiring
hole
switch box
AB
44mm
60mm
Wiring
hole
switch box
Model A
Model B
AB
HA HB
1
Other manuals for SLIM24
2
Table of contents
Languages:
Other innovair Controllers manuals
Popular Controllers manuals by other brands

Digiplex
Digiplex DGP-848 Programming guide

YASKAWA
YASKAWA SGM series user manual

Sinope
Sinope Calypso RM3500ZB installation guide

Isimet
Isimet DLA Series Style 2 Installation, Operations, Start-up and Maintenance Instructions

LSIS
LSIS sv-ip5a user manual

Rockwell Automation
Rockwell Automation 1769-L31 installation instructions