innovair RCTL-OASISP User manual

Remote Control
User Manual
Mini Split System
In order to get the highest performance from your system, please read this instruction manual carefully
before you start using it, and save it for future reference.
www.innovair.com

CONTENTS
Model
Rated Voltage
8m
3.0V(Dry batteries R03/LR03 2)×
RCTL-OASISP
Remote Controller Specifications
Environment
Signal Receiving
Range
MO DE
FAN
TEMP
SLEE P
TURBO
SWING DIRECT
LED
ON /OF F
SHORT
CUT
TIME R
ON
TIMER
OF F
2
3
6
7
7
7
8
9
12
Handling the remote controller ......................................................
Remote controller Specifications...................................................
Operation buttons .................. .........................................................
Indicators on LCD ..........................................................................
How to use the buttons .................................................................
Auto operation.................................................................................
Cooling/Heating/Fan operation......................................................
Dehumidifying operation ...............................................................
Timer operation...............................................................................
23 F~140 F
O O
NOTE:
Buttons design is based on typical
model and might be slightly different
from the actual one you purchased,
the actual shape shall prevail.
All the functions described are
accomplished by the unit. If the unit
has no this feature, there is no
corresponding operation happened
when press the relative button on
the remote controller.
Actual remote control may be different
from User Manual's illustrations. Please
refer to function description for better
understanding of your remote.

1
2
Press this button to modify the air conditioner
mode in a sequence of following:
3
MODE Button
4
5
ON/OFF Button
This button turns the air conditioner ON
and OFF.
AUTO
COOL
DRY
HEAT FAN
Used to select the fan speed in four steps:
AUTO LOW MED HIGH
FAN Button
SLEEP Button
NOTE: While the unit is running under SLEEP
mode, it would be cancelled if MODE, FAN
SPEED or ON/OFF button is pressed.
Active/Disable sleep function. It can
maintain the most comfortable temperature
and save energy. This function is available
on COOL, HEAT or AUTO mode only .
For the detail, see sleep operation in
USER S MANUAL.
,
,, ,,
,,
,,
NO TE:Please do not select HEAT mode if the
ma chine you purchased is cooling only type.
He at mod e is not supported by the cooling only
appliance.
NOTE: You can not switch the fan speed in
AUTO or DRY mode.
Operation of buttons
SHORTCUT Button
TIMER ON Button
Used to restore the current settings or
resume previous settings.
On the first time connecting to the power,
if push the SHORTCUT button, the unit
will operate on AUTO mode, 78 F, and fan
speed is Auto.
Push this button when remote controller is
on, the system will automatically revert
back to the previous settings including
operating mode, setting temperature, fan
speed level and sleep feature(if activated).
If pushing more than 2 seconds, the system
will automatically restore the current
operation settings including operating mode,
setting temperature, fan speed level and
sleep feature(if activated ).
O
UP Button( )
Push this button to decrease the indoor
temperature setting in 1 F increments to 62 F.
o o
DOWN Button( )
8
7
Press this button to initiate the auto-on
time sequence. Each press will increase
the auto-timed setting in 30 minutes
increments. When the setting time displays
10.0, each press will increase the auto-
timed setting 60 minutes increments.
To cancel the auto-timed program, simply
adjust the auto-on time to 0.0.
Push this button to increase the indoor
temperature setting in 1 F increments to 86 F.
o o
Operation of buttons
NOTE:Temperature contol is not available
in Fan mode.
6
TURBO Button
Active/Disable Turbo function. Turbo function
enables the unit to reach the preset temper-
ature at cooling or heating operation in the
shortest time(if the indoor unit does not
support this function, there is no
corresponding operation happened when
pressing this button.)
MODE MODE
FAN FAN
TEMP TE MP
ON/OFF
ON/O FF
SHORT
CUT
SHORT
CUT
TIME R
ON
TIMER
ON
TIME R
OF F
TIMER
OFF
11
22
44
33
77
88
66
55
99
10 10
11 11
12 12
SL EEP
SLEEP
TURBO
TURBO
SWIN G DIRECT
SWING DI RECT
LED
LED
NOTE: Press and hold and buttons
together for 3 seconds will alternate the temper-
ature display between the C & F scale.
UP DOWN
O O

10
11
12
Operation of buttons
LED Button
Disable/Active indoor screen Display. When
pushing the button, the indoor screen display
is cleared, press it again to light the display.
Indicators on LCD
Fan speed indication
Mode display
Information are displayed when
the remote controller is powered
up.
Displayed when data transmitted.
Displayed when remote controller is ON.
Battery display(low battery detection)
Not available for this unit
Not available for this unit
Low speed
Medium speed
High speed
Auto fan speed
Note:
All indicators shown in the figure are for the purpose
of clear presentation. But during the actual operation
only the relative functional signs are shown on the
display window.
Displayed when TIMER ON time is set.
Displayed in Sleep Mode operation.
Not available for this unit
Not available for this unit
Displayed when TIMER OFF time is set.
Show set temperature or room
temperature, or time under TIMER
setting.
AUTO
HEAT FAN
COOL DRY
SWING Button
DIRECT Button
Used to change the louver movement and set
the desired up/down air flow direction.
The louver changes 6 in angle for each press.
O
Used to stop or start horizontal louver auto
swing feature.
MO DE
FAN
TEMP
ON/OFF
SHORT
CUT
TIME R
ON
TIME R
OFF
1
2
4
3
7
8
6
5
9
10
11
12
SLEEP
TURBO
SWING DIRECT
LED
TIMER OFF Button
9
Press this button to initiate the auto-off time
sequence. Each press will increase the auto
-timed setting in 30 minutes increments.
When the setting time displays 10.0, each
press will increase the auto-timed setting
60 minutes increments. To cancel the auto-
timed program, simply adjust the auto-off
time to 0.0

How to use the buttons
Cooling /Heating/Fan operation
MODE
UP/DOWN
FAN
ON/OFF
Ensure the unit is plugged in and power is
available.
1. Press the button to select COOL,
HEAT(cooling & heating models only) or
FAN mode.
2. Press the buttons to set the
desired temperature.
3. Press the button to select the fan speed
in four steps- Auto, Low, Med,or High.
4. Press the button to start the air
conditioner.
The temperature can
be set within a range of 62 F~ 86 F in 1 F
increments.
O O O
In the FAN mode, the setting temperature is not
displayed in the remote controller and you are not
able to control the room temperature either. In this
case, only step 1, 3 and 4 may be performed.
NOTE
Auto operation
MODE
UP/DOWN
ON/OFF
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the button to select Auto.
2. Press the button to set the
desired temperature. The temperature can
be set within a range of 62 F~ 86 F in 1 F
increments.
3. Press the button to start the air
conditioner.
O O O
1. In the Auto mode, the air conditioner can logically
choose the mode of Cooling, Fan, and Heating
by sensing the difference between the actual
ambient room temperature and the setting
temperature on the remote controller.
2. In the Auto mode, you can not switch the fan speed.
It has already been automatically controlled.
3. If the Auto mode is not comfortable for you , the
desired mode can be selected manually.
NOTE
MODE
FAN
TEMP
ON/O FF
SHORT
CUT
TIME R
ON
TIMER
OFF
4
1
3
2
MO DE
FAN
TEMP
ON /OFF
SHORT
CU T
TIMER
ON
TIME R
OFF
3
1
2
Dehumidifying operation
MODE
UP/DOWN
ON/OFF
Ensure the unit is plugged in and power is
available. The OPERATION indicator on the
display panel of the indoor unit starts flashing.
1. Press the button to select DRY m ode.
2. Press the buttons to set the
desired temperature.
3. Press the button to start the air
conditioner.
The temperature
can be set within a range of 62 F~ 86 F in
1 F increments.
O O
O
In the Dehumidifying mode, you can not switch the
fan speed. It has already been automatically controlled.
NOTE
MODE
FAN
TEMP
ON/OFF
SHORT
CUT
TIME R
ON
TIMER
OFF
3
1
2
How to use the buttons
SLEEP SLEEP
SLEEP
TURBO TURBO
TURBO
SWING DIRECT SWIN G DIRECT
SWING DI RECT
LED LED
LED

2
1
Timer operation
Press the TIMER ON button can set the auto-on
time of the unit. Press the TIMER OFF button
can set the auto-off time of the unit.
1. Press the TIMER ON button. The remote
controller shows TIMER ON, the last Auto-on
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-on time to START the operation.
2. Push the TIMER ON button again to set desired
Auto-on time. Each time you press the button,
the time increases by half an hour between 0
and 10 hours and by one hour between 10 and
24 hours.
3. After setting the TIMER ON ,there will be a one
second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "h" will disappear and the set temperature
will re-appear on the LCD display window.
To set the Auto-on time.
To set the Auto-off time.
1. Press the TIMER OFF button. The remote
controller shows TIMER OFF, the last Auto-off
setting time and the signal "H" will be shown on
the LCD display area. Now it is ready to reset
the Auto-off time to stop the operation.
2. Push the TIMER OFF button again to set
desired Auto-off time. Each time you press the
button, the time increases by half an hour
between 0 and 10 hours and by one hour
between 10 and 24 hours.
3. After setting the TIMER OFF ,there will be a
one second delay before the remote controller
transmits the signal to the air conditioner. Then,
after approximately another 2 seconds, the
signal "H " will disappear and the set temperature
will re-appear on the LCD display window.
MODE
FAN
TEMP
ON/O FF
SHO RT
CUT
TIME R
ON
TI MER
OF F
When you select the timer operation, the remote controller automatically transmits the
timer signal to the indoor unit for the specified time. Therefore, keep the remote
controller in a location where it can transmit the signal to the indoor unit properly.
The effective operation time set by the remote controller for the timer function
is limited to the following settings: 0.5, 1.0, 1.5, 2.0, 2.5, 3.0, 3.5, 4.0, 4.5, 5.0,
5.5, 6.0, 6.5, 7.0, 7.5, 8.0, 8.5, 9.0, 9.5, 10, 11, 12, 13, 14, 15,16,17, 18, 19, 20,
21, 22, 23 and 24.
CAUTION
!
Example of timer setting
Start
Off
6 hours later
(Auto-on Operation)
The TIMER ON feature is useful when you want
the unit to turn on automatically before you return
home. The air conditioner will automatically start
operating at the set time.
To start the air conditioner in 6 hours.
1. Press the TIMER ON button, the last setting
of starting operation time and the signal
2. Press the TIMER ON button to display "6.0H
on the TIMER ON display of the remote
controller.
3.
"H"
will show on the display area.
"
Wait for 3 seconds and the digital display
area will show the temperature again. The
"TIMER ON" indicator remains on and this
function is activated.
TIMER ON
Example:
SLEEP
TURBO LED
SWING DIRECT

Stop
On
Set 10 hours later
(Auto-off Operation)
The TIMER OFF feature is useful when you want the
unit to turn off automatically after you go to bed. The
air conditioner will stop automatically at the set time.
To stop the air conditioner in 10 hours.
1. Press the TIMER OFF button, the last setting of
stopping operation time and the signal "H" will
show on the display area.
2. Press the TIMER OFF button to display "10H " on
the TIMER OFF display of the remote controller.
3. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
OFF" indicator remains on and this function is
activated.
TIMER OFF
Example:
On
Stop
2 hours later
after setting
Set
To stop the air conditioner 2 hours after setting and
start it again 10 hours after setting.
1. Press the TIMER OFF button.
2. Press the TIMER OFF button again to display
2.0H on the TIMER OFF display.
3.
4. Press the TIMER ON button again to display 10H
on the TIMER ON display .
5.
Press the TIMER ON button.
Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON OFF" indicator remains on and this function is
activated.
TIMER OFF TIMER ON
(On Stop Start operation)
This feature is useful when you want to stop the air
conditioner after you go to bed, and start it again in
the morning when you wake up or when you return
home.
→
→ →
Example:
COMBINED TIMER
(S both ON and OFF )etting timers simultaneously
Start
10 hours later
after setting
Example:
TIMER ON TIMER OFF
(Off Start Stop operation)
This feature is useful when you want to start
the air conditioner before you wake up and
stop it after you leave the house.
→
→ →
To start the air conditioner 2 hours after setting,
and stop it 5 hours after setting.
1. Press the TIMER ON button.
2. Press the TIMER ON button again to display
2.0H on the TIMER ON display.
3. Press the TIMER OFF button.
4. Press the TIMER OFF button again to display
5.0H on the TIMER OFF display .
5. Wait for 3 seconds and the digital display area
will show the temperature again. The "TIMER
ON & TIMER OFF" indicator remains on and
this function is activated.
Off
Stop
Start
2 hours later
after setting
5 hours later
after setting
Set
8m
Use the remote controller within a distance of 8
meters from the appliance, pointing it towards the
receiver. Reception is confirmed by a beep.
Location of the remote controller.
CAUTIONS
The air conditioner will not operate if curtains,
doors or other materials block the signals from
the remote controller to the indoor unit.
Prevent any liquid from falling into the remote
controller. Do not expose the remote controller
to direct sunlight or heat.
If the infrared signal receiver on the indoor unit
is exposed to direct sunlight, the air conditioner
may not function properly. Use curtains to
prevent the sunlight from falling on the receiver.
If other electrical appliances react to the remote
controller, either move these appliances or
consult your local dealer.
Do not drop the remote controller. Handle with
care.
Do not place heavy objects on the remote
controller, or step on it.
Handling the remote controller

The remote controller can be attached to a wall
or pillar by using a remote controller holder
(not supplied, purchased separately).
Before installing the remote controller, check
that the air conditioner receives the signals
properly.
Install the remote controller with two screws.
For installing or removing the remote controller,
move it up or down in the holder.
The following cases signify exhausted batteries.
Replace old batteries with new ones.
Receiving beep is not emitted when a signal
is transmitted.
Indicator fades away.
Using the remote controller holder
(optional)
The remote controller is powed by two dry
batteries (R03/LR03X2) housed in the back rear
part and protected by a cover.
(1) Remove the cover in the rear part of the
remote controller.
(2) Remove the old batteries and insert the new
batteries,placing the(+) and (-) ends correctly.
(3) Install the cover back on.
When the batteries are removed, the
remote controller erases all programming. After
inserting new batteries, the remote controller
must be reprogrammed.
NOTE:
Replacing batteries
CAUTIONS
Do not mix old and new batteries or batteries
of different types.
Do not leave the batteries in the remote
controller if they are not going to be used for
2 or 3 months.
Do not dispose batteries as unsorted
municipal waste. Collection of such waste
separately for special treatment is necessary.
The device could comply with the local national regulations.
In Canada, it should comply with CAN ICES-3(B)/NMB-3(B).
In USA, this device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions:
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential ins tallation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipm ent into an outlet on a circuit different from that to which the
receiv er is connected.
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications not approved by the party responsible for compliance could
void user s authority to operate the equipment.
NOTE:
Table of contents
Other innovair Remote Control manuals