InovaAir AirClean V20 User manual

AirClean V20
Air Purier
AirClean V20 Healthcare User Manual

2
Contents
Important Safety Instructions
Introducing your InovaAir®AirClean system
How your AirClean system works
Positioning your AirClean system
System operation
Getting the most out of your AirClean system
Accessing the lters
When to replace the lters
Replacing lters
Ordering new lters
System warranty
3
4
5
5
6
7
8
9
10
10
11

3
Important safety instructions
Please read these instructions before operating the InovaAir®System and keep for future reference.
To reduce the risk of re, electric shock, or injury
1. Do not detach motor-outlet module until the system has
been switched off.
2. Disconnect power, or unplug, before cleaning, performing
any maintenance or replacing a lter.
3. Use caution when moving the air purier to avoid
injury. We advise removing the lters prior to lifting or
transporting the system.
4. Do not operate unless all components are fully
assembled, securely latched and in the upright position.
Failure to do so may result in serious injury.
5. Leave a distance of at least 100mm between the
appliance and the nearest wall to allow for adequate air
circulation.
6. Always keep air intake and outlet of the unit unobstructed.
7. Do not use near water or moisture or the immediate
surroundings of a bath, shower, or swimming pool.
8. Do not immerse the air purier in water or any other
liquid.
9. Do not let objects, or liquid, enter the product.
10. Do not handle any part of the appliance or plug with wet
hands.
11. Do not install near any heat sources.
12. Do not operate this appliance if it has a damaged cord or
plug, is not working correctly, or has been dropped.
13. Do not use this appliance if it has been damaged or
submerged in water.
14. The appliance is not to be used by persons (including
children) with reduced physical, sensory, or mental
capabilities, or lack of experience and knowledge, unless
they have been given supervision or instruction.
15. If the supply cord is damaged, it must be replaced with a
new cord. Contact our support team for a replacement.
16. Keep power cord away from heated surfaces.
17. Refer all servicing to qualied InovaAir® service
personal. Servicing is required when the product has
been damaged in any way. Do not attempt to service
this product yourself. Opening or removing covers may
expose you to dangerous voltages or other hazards and
may void warranty.
18. Unplug the air purier during lightning storms or when
unused for long periods.
19. Do not use this appliance as sole protection against
harmful pollutants.
20. Do not use outdoors.
21. Keep the appliance away from ammable liquids, vapours,
air fresheners and essential oils.
22. Do not use in explosive or ammable environments.
23. Use only on solid, horizontal, and stable surfaces.
24. Do not operate in high temperatures over 40°C

4
Introducing your InovaAir®AirClean system
Inside the V20 box, you will nd the InovaAir®unit consisting:
• V20 System Case/Motor
• Filter Base Plate (detachable)
• Power Cable (located in base of box)
• V20 Pre-lter (pre-installed)
• V20 HEPA Filter (pre-installed)
TechnostatTM high
efciency pre-lter.
Certied Medical-
grade HEPA lter
99.97% @
0.3 microns
efciency.

5
How your AirClean system works
Air is drawn into the system
through the sides of the
unit.
Air passes through the ne
dust pre-lter.
Air passes through the H13
HEPA lter which removes
dust, allergens and sub-
micron ne particle matter.
The puried air is then
returned to the room via
the high air-ow diffuser.

6
System operation
Variable Speed
Controller
Power cord inlet
On/Off switch
Please note, there can be a delay
of up to 20 seconds before the fan
is running at the speed you have
selected.
Speed Control
The system has a variable speed controller and uses an energy efcient European AC fan.
Power consumption is relative to the selected speed.
Power Consumption
(Watts)
Control position
The higher the speed, the more times per hour the air in your living space will be cleaned, so it is recommended to
run the system at the highest speed you are comfortable with. Higher fan speeds will generate higher sound levels.
Min 2 4 6 8 10 12 14 16 18 20
6 8 10 14 20 29 40 48 68 82 84
100 155 210 265 320 375 430 485 540 595 650
Airow
(m3/hour)

7
Getting the most out of your AirClean system
Operate the system 24/7.
As contaminants are always present in the air, for maximum effectiveness you should operate the system continuously.
By switching the system off you are only allowing these contaminants to build up in the interim until it is switched back on.
InovaAir systems are designed for optimal energy efciency.
Enclose the area where you are operating the system.
Closing doors will allow the system will be much more effective as it will only be ltering air in the one room.
Operate at the highest speed practical
All InovaAir systems include variable speed controls and the speed should be varied depending on the room size, the
level of air pollutants present, and the specic application. The higher the operating speed the more effective the system
will be in reducing contaminants in the air.

8
Accessing the lters
Recommended lter replacement intervals
FILTER NAME APPROXIMATE REPLACEMENT INTERVAL*
Pre-Filter (Wrap-around) 3-6 months (continuous use)
H13 HEPA Filter 3 years (continuous use)
Filter life will vary based on levels of dust present and system proximity to major pollution sources each of which may lower
any of the lter lifespans. InovaAir does not warranty consumable lter life.
1. Disconnect the power cord.
2. Ensure system is sitting on a at and even surface.
3. Pull top of the latches (A) away from the main unit.
4. Push the latches back towards the main unit (B)
5. Ensure the latch clasps are clear of catches on the base (C).
6. Lift casing clear of base to access lters.
A
B
C

9
When to replace the lters
When changing lters
Turn off and unplug the system before unlatching system housing.
To reduce the risk of infection please follow your organisation’s personal protective equipment (PPE) guidelines. This may include
protective clothing, gloves, a mask or a respirator as the used lters may be extremely dirty, dusty or considered a biohazard if
there has been any exposure to infection.
Remove lter and place in a large, sealable bag. Seal the bag closed. Discard the bagged lter in an outdoor waste container or
contaminated waste receptacle if available.
Important: Do not attempt to vacuum the HEPA or Pre-lter as this will damage the ne lter bres and reduce efciency.
Air intake vents on the sides of the system can be vacuumed with a HEPA grade vacuum, including the base plate which sits
under the lters.
Stage 1: Pre-lter
The pre-lter is the initial stage of ltration, ltering large
dust particles right down to ultra-ne sub-micron particles
as well as viruses and bacteria. It is made from a patented
material used in respirators and face masks.
Dust levels in the ambient air will affect how long the pre-
lter will last.
Pre-lters are white and will turn grey within 1-2 weeks
of use, this is nothing to be concerned about and simply
means the lter is doing its job.
In clinical settings, depending on the application and
level of exposure to contaminants, the pre-lter should be
replaced every 1-3 months.
Stage 2: Medical-grade HEPA lter
The H13 HEPA lter is designed to last 3 years under normal
use. As with other lters, the environment in which it is used
will determine the lter life.
The outside of the HEPA lter will change colour and turn
dark grey when it needs replacing. Generally for the rst two
years of use, the lter will remain white and then gradually
get darker in the nal months of its life. Please note, the
inside of the HEPA lter will always remain white so it is
important to check the outside of the lter which is visible
when the pre-lter is being changed.

10
Replacing lters
Ensure the lter is
positioned within the
locators and sitting at on
the base.
Replacement lters can be ordered from the InovaAir website using the URL or QR code below.
www.inovaairpuriers.com.au/replacement-lters
Ordering new lters
The HEPA lter can be lifted
from the base and replaced
when required.
The pre-lter is wrapped
around the HEPA lter &
fastened with Velcro.
Gently unwrap from the
lter & replace with a new
pre-lter.
Ensure pre-lter is installed
so the ‘uffy’ Velcro strip is
facing outwards and is rmly
tted around the HEPA lter
to avoid air bypassing the
pre-lter.

11
System warranty
Denitions
In this warranty:
“ACL” refers to the Australian Consumer Law . “Back to Base” means where delivery
to and collection of your product from the Service Agent is your responsibility.
“Consumable” includes (without limitation) lters and pre-lters. “InovaAir®Australia”
means InovaAir®Australia Pty Ltd ACN 103 549 435. “Factory Second” means a Product
sold by InovaAir®Australia or any other authorised person as a ‘second’ meaning a
product with a small imperfection that does not impede functioning. “Genuine” means
manufactured by or on behalf of InovaAir®Australia. “Product” means a Genuine
Product supplied new by InovaAir® Australia. “Purchase Date” means the date of rst
purchase from InovaAir®Australia or any other authorised person seller or distributor.
“Any other authorised person” means a dealer, reseller or retailer of the Product.
“Service Agent” means an authorized InovaAir®Australia service agent. “You” means
the End User and “your” has a corresponding meaning.
Introduction
Subject to these conditions, InovaAir®Australia Pty Ltd offers this Warranty on a Product
to which it’s Back to Base service applies.
(1) This Warranty applies in addition to the conditions and warranties implied by the
Act in relation to a Product.
(2) Any other authorized person who has sold a Product to you has acted as
principal and has no authority to give any additional warranty or guarantee in
relation to the Product on behalf of InovaAir®Australia.
(3) InovaAir®Australia will not be liable for any consequential loss, indirect or
special damage arising from your use of the Product. In particular (but without
limitation) InovaAir®Australia excludes any liability for actual or expected revenue
loss or other loss.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is
intended to override such exclusions.
(4) In no event shall InovaAir®Australia, its agents, employees, or distributors be
liable for special, incidental, consequential, or indirect damages.
(5) The provisions of this warranty supersede and are in lieu of any other
warranty, whether express or implied, written or oral, including any warranty of
merchantability or tness for a particular purpose.
NB. This exclusion is subject to any relevant Commonwealth or state law, which is
intended to override such exclusions.
(6) Maximum liability shall not exceed the actual purchase price paid for this
product.
(7) This warranty is non-transferable.
(8) Should any of the conditions of the warranty be deemed unenforceable then
same shall be severable from the balance of warranty conditions, which shall remain
legally binding.
5 Year warranty
InovaAir® Australia warrants that your Product will be free from defects in materials or
workmanship for five (5) year/s from your Purchase Date. Two (2) years in commercial
applications).
At its discretion, InovaAir®Australia will repair or replace your Product, if it is found be
defective. InovaAir®Australia will, if it deems the unit defective, either repair or replace
the unit at its sole option (and, based on availability, may elect to replace the unit with an
air purier of similar function or value).
To make a Warranty claim, you must:
• First call InovaAir® Australia’s Contact Centre on 1 300 137 244;
• Return the Product (if warranty service is required) in its original packaging (or
suitable alternative) to a Service Agent, as discussed with the Contact Centre; and
• Provide a copy of your purchase receipt, to show that this Warranty applies to
your Product at the date of your claim.
You are responsible for the cost of and risk in delivery of your Product to and its
collection from the Service Agent.
Warranty application
This Warranty applies only:
a. To a Product that is supplied new to You by InovaAir®Australia or by any other
authorized person;
b. If you use the Product for your own private or business purposes; and
c. You have not bought the Product for resale.
Warranty exclusions
This Warranty will not apply if during the warranty period:
a. A Product’s serial number or any rating label is removed or changed in any way;
This warranty shall immediately become void if the unit’s serial number label is
removed, altered, or is no longer clearly legible;
b. A Product is repaired other than by a Service Agent;
c. You use a Product contrary to any technical or operating environment or safety
guidelines recommended in its user guide or manual;
d. No fault found service calls where the perceived problem is explained within the
Operating Manual or the trouble shooting section of the operating manual.
e. This Warranty does not cover costs associated with delivery, handling, freighting
or damage to product in transit.
f. This Warranty does not apply to a Product’s malfunction or failure resulting from:
i. Deliberate or accidental damage;
ii. Rust or damage to paintwork, varnishes or seals caused by a corrosive
atmosphere;
iii. Vermin infestation;
iv. Any modication by the purchaser which affects the reliability or
performance of the unit, not attributable to faulty manufacture, parts and
labour;
v. Where a unit is installed incorrectly by the purchaser or its servants agents
employees or by unqualied persons;
vi. Failure is due to improper installation or faulty installation;
vii. Failure is due to improper maintenance by customer (refer to maintenance
section of Operating Instructions);
viii. Misuse, abuse or neglect;
ix. Incorrect voltage or a power surge; or
x. Your use of any non-genuine Consumables parts accessories or interfacing;
xi. Failure to remove or replace out of date or non-functioning lter.
g. This warranty covers only manufacturing defects, and not normal wear and tear,
including lters which are considered consumables.
h. InovaAir®does not warrant the Product as a health safety device. The product is
not a Medical Device or Therapeutic Device as dened by the Therapeutic Goods
Act 1989.
i. All exclusions as determined by InovaAir® Australia at its sole discretion.
j. Filter life: InovaAir® does not warrant the useful life of lter consumables. The
lter consumables working life will depend entirely on the environments in which
it is used. In dusty environments lter life will be reduced. The Products and their
lters are not intended to be used for dust extraction in industrial or commercial
applications.
Non-genuine items
InovaAir®Australia advises that if you use non-Genuine Consumables, replacement parts
or accessories, you may damage your Product and may void your warranty.
Australian Consumer Law
In addition to your rights under the InovaAir® guarantee, we also provide the following
statement as required by the Australian Consumer Law: In Australia, your InovaAir®
appliance comes with statutory guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and for
compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have your InovaAir® appliance repaired or replaced if it fails to be of
acceptable quality and the failure does not amount to a major failure.

InovaAir Australia Pty Ltd
Unit 8, 1 Reliance Drive,
Tuggerah, NSW 2259 Australia
TEL: 1300 137 244
www.airclean.com.au