Technical Data
The product is only intended for the use within the permissible technical limits specified in the data sheets. These limits must be observed.
Operating voltage (redundant)
GSM/GPRS frequencies (2G)
typ. 2.5 W, max. 8 W
fully equipped: max. 20 W
UMTS/HSPA frequencies (3G)
HIGH level = 2 ... 24 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
800, 900, 1800, 2100, 2600 MHz
Current consumption input IN1
at LOW potential
typ. 0.1 mA when connecting
to GND
Real-time clock (RTC) buffer
time
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
-30 °C … 70 °C
(75 °C extended)
Power consumption input IN2
at HIGH potential
Maximum permissible humidity
Technical Boundaries
Max. line length for antennas, power supplies, serial interfaces, inputs and outputs as well as other signals: 30 m
Max. line length of USB connection lines: 3 m
Cable cross-section: 0.25 … 1.5 (2.5) mm² (depending on terminal size), flexible lines require end sleeves
Support
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e -mail
under support@insys-icom.de.
Defects liability terms
A use other than the intendeduse, an ignorance of the safety instructions and the documentation, th e use of insufficiently qualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resulting from this. Th e liabilityof the
manufacturer ceases to exist.
In tended Use
The product may only be used for the purposes specified in the functionoverview of the manual. In addition, it may be used for the
following purposes:
▪Usage and mounting in an industrial cabinet.
▪Switching and data transmission functions in machines according to the machinedirective 2006/42/EC.
▪Usage as data transmission device, e.g. for a PLC.
The product may n ot be used for the following purposes and used or operated under thefollowing conditions:
▪Use, control, switching and data transmission in machines or systems in explosive atmosp heres.
▪Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.