manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. insys icom
  6. •
  7. Network Router
  8. •
  9. insys icom MRX DSL User manual

insys icom MRX DSL User manual

ENGLISH
Quick Installation Guide
MRX DSL
www.insys-icom.com
These short operating instructions apply for the following devices of INSYS icom:
▪MRX3 DSL
▪MRX5 DSL
www.insys-icom.com/manual 
It is intended for a quick commissioning by the operator. Refer to the associated manual for further information.
This and other associated manuals can be found on our website in the menu Support > Documentation and
Downloads. Scan the QR code above or enter the URL into your web browser.
Technical Data
The product is only intendedfor the use within the permissible technical limits specified in the datasheets. These limits must be observed.
Operating voltage (redundant)
12 V … 24 V DC (±20%)
Supported DSL standards
VDSL2 G.993.2 Profile 8a, 8b,
8c, 8d, 12a, 12b, 17a. 30a
VDSL2 Vectoring G.993.5
Power consumption
approx. 6 W
fully equipped: max. 20 W
Supported DSL standards A
ADSL G.992.1 Annex A,
G.992.3. Annex A/L/M, G.992.5
Annex A and M, T1.413
Level input IN1
HIGH level = 2 ... 24 V
LOW level = 0 ... 1 V
Contact open condition: HIGH
Supported DSL standards B
ADSL G.992.1 Annex B,
G.992.3. Annex B, G.992.5
Annex B and J
Current consumption input IN1
at LOW potential
typ. 0.1 mA when connecting to
GND
Real-time clock (RTC) buffer
time
typ. 2 days
Level input IN2
HIGH level = 10 ... 24 V
LOW level = 0 ... 5 V
Contact open condition: LOW
Temperature range
0 °C … 50 °C
(-25 °C … 55 °C extended)
Current consumption input IN2
at HIGH potential
max. 3 mA at 24 V DC
Maximum permissible
humidity
95% non-condensing
IP rating
Housing IP40
AOnly for MRX3/5 DSL-A
BOnly for MRX3/5 DSL-B
Technical Boundaries
Max. line length for antennas, power supplies, serial interfaces, inputs and outputs as well as other signals: 30 m
Max. line length of USB connection lines: 3 m
Cable cross-section: 0.25 … 1.5 (2.5) mm² (depending on terminal size), flexible lines require end sleeves
A splitter must be connected upstream when connecting to DSL lines in telephone networks like Annex A or Annex B.
Support
If you need further support, please contact your sales partner or INSYS icom support. You can contact our support department via e-mail
under support@insys-icom.de.
Defects Liability Terms
A use other than the intended use, an ignorance of the safety instructions and the documentation, the use of insufficiently q ualified
personnel as well as unauthorised modifications exclude the liability of the manufacturer for damages resu lting from this. The liability of the
manufacturer ceases to exist.
In tended Use
The product may only be used for the purposes specified in the function overview of the manual. In addition, it may be used f or the
following purposes:
▪Usage and mounting in an industrial cabinet.
▪Switching and data transmission functions in machines according to the machinedirective 2006/42/EC.
▪Usage as data transmission device, e.g. for a PLC.
The product may n ot be used for the following purposes and used or operated under thefollowing conditions:
▪Use, control, switching and data transmission in machines or systems in explosive atmospheres.
▪Controlling, switching and data transmission of machines, which may involve risks to life and limb due to their functions or when a
breakdown occurs.
ENGLISH
Quick Installation Guide
MRX DSL
www.insys-icom.com
A
Router connection
1. Connect DSL connection line with VDSL/ADSL socket
2. Connect supply voltage (12 V … 24 V DC (±20%))
to the terminals V+1and GND
3. Connect router (ETH 1) to the configuration PC
4. Connect router (ETH 2) to the network
in which your system is located
B
LAN settings of configurations PC (Windows 7)
If a DHCP client is active on the PC, proceed with step C. Otherwise, either enable the
DHCP client or configure a static IP address.
5. Open Network and Sharing Center (e.g. key and search for "sharing")
6. Select LAN connection and Properties
7. Select Internet Protocol Version 4 (TCP/IP) and Properties
Enable DHCP client
8. Obtain an IP address automatically
It is recommended to unplug the
network cable briefly and plug it
again upon activation of the DHCP
client.
Configure a static IP address
Use the following IP address (example):
IP address: 192 . 168 . 1 . 2
Subnet mask: 255 . 255 . 255 . 0
Standard gateway 192 . 168 . 1 . 1
Preferred DNS server: 192 . 168 . 1 . 1
Please note the previous values before
changing the TCP/IP settings to be able
to restore them later.
C
Web interface access
9. Enter IP address of the router in address bar of the browser
(default: 192.168.1.1)
If a proxy server is enabled in your browser, this must be disabled or the IP address of
the router must be added as exception.
10. Login with
Name
(default: insys) and
Password
(icom)
11. Open the Inline Help using the button (Display help text) in the header
The links in the Inline Help lead to the Online Help with further information.
All modified data will only be stored in the opened profile after clicking the
Save
settings
button and become effective upon clicking the (Activate profile) button.
ENGLISH
Quick Installation Guide
MRX DSL
www.insys-icom.com
D
Configuration as DSL router
12. In Menu Help > Wizards: Select Startup Wizard
13. Select Internet access via DSL (refer to
inline help for WAN over Ethernet)
These data can be found in the contract
documents or can be requested from
the provider.
14. Select the access mode supported by
the provider and enter the appropriate
access data
15. Enter VLAN tag if required
16. Adjust VPI, VCI and Multiplex
according to the specifications of the
provider if required
17. Enter IP address of the local application
network
If the router is to be configured for the
icom Connectivity Suite - VPN
(https://connectivity.insys-icom.de),
select icom Connectivity Suite –VPN
under VPN connection and enter
Customer name and Device code (from
icom Connectivity Suite –VPN, “My
VPN Hub” tab). Then, the IP address in
the local network will be assigned by
the icom Connectivity Suite - VPN.
18. Click on
Execute wizard
The DSL LED flashes green during connection establishment; as soon as a connection
has been established (Showtime), it is illuminated green and blinks orange with data
transfer.
If the web interface of the router does not return upon executing the wizard, click on
“Reload” in the browser (or Ctrl+F5).
E
Configuration of access data
User name and password for web interface access of the existing user in the default
settings must be changed to prevent a manipulation of the configuration by
unauthorised persons.
19. Menu Administration > Users: Enter or change User name and Password and select
User group "Read/Write"
20. Store settings in profile with
Save setting
s and activate profile with
A typo during entering or forgetting the configured access data require a reset to
default settings to be able to access the router again.
All essential configuration steps are completed with this. Further configuration depends on your specific
application. Other frequently required settings are available on the following page.
ENGLISH
Quick Installation Guide
MRX DSL
Mat. no. 10019452 –version 18 December 2019 17:37:23 –Subject to technical changes and correction
www.insys-icom.com
IP address in configuration network
The IP address of the router in the configuration network does only have to be changed,
if the IP address is already used or a different address range is required. Then, the web
interface is immediately accessible under the new address.
1. Menu Interfaces > IP net 1: Adjust IP address of the router in configuration network
2. Store settings in profile with
Save settings
and activate profile with .
3. Adjust IP settings of the PC for further configuration accordingly, if these are not
obtained automatically (see step B)
4. Menu Services > DHCP Server: Adjust address range to the configuration network, if
the DHCP server of the router is used
Using the router as icom Smart Gateway
If the router is to be used as an icom Smart Energy or Machinery Gateway for example,
this is the best time now to install the icom Data Suite required for this. A wizard is
available for this in the
Help
menu. Refer to the Quick Installation Guide of the icom
Data Suite (https://www.insys-icom.com/manual#icom-data-suite) or the respective
Configuration Guide (https://docs.insys-icom.de/en_icom_data_suite.html).
Resetting the router
If it is necessary to reset the router during configuration, this is possible without losing
the settings.
1. Menu Administration > Reset:
2. Click on
Reboot device now
Alternatively, press reset key on the device front once for a short time (soft reset)
Resetting the router to default settings
If the router is to be reset to default settings, it can be reset to delivery state.
1. Menu Administration > Reset: check all options
2. Click on
Reset now
Alternatively, press reset key on the device front three times for a short time within
2 seconds
Resetting and initialising the router
If the router is not available any more for any reason, it can be reset and initialised
(settings do not get lost).
1. Press reset key on the device front for at least 3 seconds (hard reset)
The Inline Help opens upon selecting the button ? (Display help text) and provides helpful
information regarding each individual parameter directly in the web interface.
The Online Help is opened using the links in the Inline Help or in the Help menu in the web
interface and provides further information to the respective topics.
The Configuration Guides are available under https://docs.insys-icom.de and provide helpful
information regarding the integration of your product into your application.
Hereby, INSYS Microelectronics GmbH declares that herein described device types are in compliance with Directives 2014/30/EU
and 2011/65/EU. The full text of the EC Declaration of Conformity is available under www.insys-icom.com/manual.

This manual suits for next models

2

Other insys icom Network Router manuals

insys icom MRX LTE User manual

insys icom

insys icom MRX LTE User manual

insys icom ECR-EW300 User manual

insys icom

insys icom ECR-EW300 User manual

insys icom EBW-E User manual

insys icom

insys icom EBW-E User manual

insys icom MoRoS LAN User manual

insys icom

insys icom MoRoS LAN User manual

insys icom SCR Series User manual

insys icom

insys icom SCR Series User manual

insys icom MRX3 LAN User manual

insys icom

insys icom MRX3 LAN User manual

insys icom MRO-L200 User manual

insys icom

insys icom MRO-L200 User manual

insys icom EBW-W User manual

insys icom

insys icom EBW-W User manual

insys icom ECR-LW300 User manual

insys icom

insys icom ECR-LW300 User manual

insys icom SCR-E200 User manual

insys icom

insys icom SCR-E200 User manual

Popular Network Router manuals by other brands

Asus ZenWiFi Pro ET12 quick start guide

Asus

Asus ZenWiFi Pro ET12 quick start guide

LuxCam Connect user manual

LuxCam

LuxCam Connect user manual

Draytek Vigor 2763 Series quick start guide

Draytek

Draytek Vigor 2763 Series quick start guide

Billion BiPAC 7402VL user manual

Billion

Billion BiPAC 7402VL user manual

NetComm NB3300 quick start guide

NetComm

NetComm NB3300 quick start guide

NetComm Liberty 3GM2WN Product data sheet

NetComm

NetComm Liberty 3GM2WN Product data sheet

Repotec RP-WR5822 user manual

Repotec

Repotec RP-WR5822 user manual

ZyXEL Communications VMG1312-B10D quick start guide

ZyXEL Communications

ZyXEL Communications VMG1312-B10D quick start guide

Cradlepoint COR Series user manual

Cradlepoint

Cradlepoint COR Series user manual

Grandbeing MX0404-330 operating instructions

Grandbeing

Grandbeing MX0404-330 operating instructions

HP MSR SERIES Configuration guide

HP

HP MSR SERIES Configuration guide

Korenix 4510 user manual

Korenix

Korenix 4510 user manual

Nortel Secure Router 2330 installation instructions

Nortel

Nortel Secure Router 2330 installation instructions

Draytek VIGOR2950 user guide

Draytek

Draytek VIGOR2950 user guide

TRENDnet GREENnet TEW-639GR Quick installation guide

TRENDnet

TRENDnet GREENnet TEW-639GR Quick installation guide

NetComm NB7 Specifications

NetComm

NetComm NB7 Specifications

Opengear CES-8940 user manual

Opengear

Opengear CES-8940 user manual

Temperature@lert TM-WIFI220 user guide

Temperature@lert

Temperature@lert TM-WIFI220 user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.