Enterprise Platforms and Services Marketing Monthly Specification Update
53. Downgrading the firmware of the Integrated RAID (ROMB), Intel® Embedded
Server RAID Technology II, or SAS may cause system damage...........................................25
54. In the Intel® Server Systems SR2500ALLX and SR1550ALSAS, flashing of SAS
firmware 1.22 and SAS BIOS 06.16.00 makes hard drive #1 (upper left drive tray) undetected
during SAS controller scanning..............................................................................................25
55. Microsoft Windows 2003 R2 SP2* may display blue screen during an operating
system boot or shutdown with a specific version of IntelI/OAT driver ..................................26
56. Server System Event Log (SEL) time may be one day later than BIOS time after
entering year 2008.................................................................................................................27
57. Performance Power Management Error in Microsoft Windows Server 2008* .......27
58. Midplane2 hardware RAID produces unexpected beep sounds during system
POST 28
59. Platform Confidence Test (PCT) fails with BIOS 89/91 on Intel® Server Board
S5000PAL/S5000XAL............................................................................................................28
60. USB mouse may hang in BIOS 94 RAID Console................................................28
61. PCI IBIST Error with BIOS 84...............................................................................29
62. System May Hang during Login or Shutdown.......................................................29
63. Hard Disks Are Difficult to Install in Intel® Server System SR2500AL and Intel®
Server Chassis SR2500.........................................................................................................29
64. System May not Boot After Multiple DC power Cycles with BIOS Revision R009830
65. System will not skip CD/DVD drive with BIOS Revision R0098 when RMM2
installed 30
66. Please use AXXMINIDIMM512 as the replacement solution for AXXMINIDIMM
which is EOLed......................................................................................................................31
67. Minus “year” number to go past “2000” at BIOS “system date” set up interface will
cause the server system to hang ...........................................................................................31
68. Please do not downgrade BIOS from factory shipped BIOS 101 to any previous
version .............................................................................................................................31
69. The Serial Port Console Redirection displays the Adaptec® 5805 RAID
Configuration Utilitye incorrectly
Documentation Changes........................................................................................................33
1. The SMBUS block diagram (Figure #16) provided in Rev. 1.1 of the Intel®Server
Board S5000PAL/S5000XAL TPS requires changes to accurately reflect production hardware
design .............................................................................................................................33
2. The power block diagram (Figure #25) as provided in Rev. 1.1 of the Intel®Server
Board S5000PAL/S5000XAL TPS does not reflect the final, production-level baseboard
design .............................................................................................................................34
3. SAS/SAS RAID midplane board (Figure #22) as provided in Rev.1.0 of the Intel®
Server System SR2500AL TPS should swap the descriptions of items A and K....................35
4. Front panel pin-out in the Intel®Server Board S5000PAL Quick Reference Label is
incorrect .............................................................................................................................36