1. OPERATING INSTRUCTIONS
1.1 Introducon.......................................................................................................................1
1.2 Markings CE......................................................................................................................1
1.3 ElectromagnecCompability(EMC)................................................................................1
1.4 InstallaonandOperaon.................................................................................................1
1.5 Calibraon..........................................................................................................................3
1.6 Warnings / Hazards............................................................................................................3
1.7 InspeconandRepair........................................................................................................4
2. WARRANTY
2.1 Warranty............................................................................................................................ 6

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 1 of 6
1.1 Introducon
ThisinstruconmanualreferstotheInterfacemodelWTSTLtensionlinktelemetryopons.Beforeinstalling
oroperanganyInterfacetensionlink,thisandanyreferencedocumentsshouldbereadandunderstood.
IncompliancewiththeMachineryDirecve,Interfacetensionlinkloadcellswillbesuppliedwiththefollowing
documents:InstruconManualandCalibraonCercate.
1.2 Markings CE
Eachtensionlinkwillbemarkedwithanindividualserialnumber,CElabelandtheSWL(safeworkingload)of
the tension link.
1.3 ElectromagnecCompability(EMC)
The electromagnec compability of the load cell device can only be assessed in conjuncon with the enre
installaon, including its control systems. The machine builder who installs this partly completed machinery
into a machine is responsible for compliance with the EMC direcve.
1.4 InstallaonandOperaon
Toensuresafeandtrouble-freeinstallaonofthetensionlinkmeasuringdevice,thetensionlinkmustbe
properlytransportedandstored,professionallyinstalledandplacedinoperaon.
Unpacking
Beforeremovingthetensionlink,inspectthepackagingforsignsofdamageandimmediatelyinformthe
supplierifanydamageisfound.Unpackthetensionlinkcarefully,takingspecialcarewithcablesandbe
awaretothepossibilityofdamaginglow-rangedevicesbymishandling.Ensurethatcalibraonandinstrucon
informaonisnotinadvertentlydiscarded.
ChecksPriortoInstallaon
• Checkthatthetensionlinkhasbeensuitablyselectedfortheenvironmentitisbeingplacedinto.Any
adversetemperature,corrosiveorpotenallyexplosiveenvironmentsmayaecttheoperaonallifeand
thesafetyoftheproduct.
• Ifthetensionlinkisedwithatelemetrymodule,checkthatthe2AAAbaeriesarecorrectlyinstalled,
thatthetwoREDclipsonthetelemetryhousingareclosedandthatthebaerycoverissecure.SeeFigure
1 for details.
OPERATING INSTRUCTIONS

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 2 of 6
1
2 x AAA Batteries Mounting Disc
Battery Cover Battery Holder
Telemetry Housing
Battery Cover Clips
n
Figure 1
Installaon
Tensionlinkloadcellsarenormallyclassiedasportabledevices,andsothecorrectinstallaoniscricalto
ensuringproductlifecycle.Toavoiddamageorlossofaccuracyduringinstallaon,thefollowingpointsshould
befollowed.
• ThedireconoftheloadappliedtoalinkshouldbelinearasshowninFigure2.
• Ensurethetensionlinkloadcelldoesnotexperiencetorqueorbendingforcesduringoperaon.
• ThetensionlinkloadcellshouldonlybeloadedintensionusingtheØCholesasshowninFigure2.See
gure3fortwocommonexamplesofinstallaons.
• ForopmalperformanceaghttolerancewiththeØCloadingholesisrecommended.
• Ifthetensionlinkisedwithatelemetryunitthenensurethataclearline-of–sightbetweenthe
transmierandreceiverismaintainedandthatobjectsorstructuresarekeptatleastonemeteraway
fromantennaewhereverpossible.TheinstallershouldalsorstreadtheWTSTelemetryUserManual
whichcanbefoundatthefollowingwebaddress:www.interfaceforce.com.
LOAD LOAD
ØC
ØC
LOAD LOAD
Figure 2 Figure 3

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 3 of 6
Electrical Checks
Thecorrectconneconofatensionlinktoaninstrumentiscricaltoachievingandmaintainingthe
performanceandreliabilityoftheloadcell.
• Tensionlinkcablingmustbekeptawayfromhighpowercablesandequipment,highoutputRFequipment
andinducveloadsandgenerators.
TensionlinkOutput
Whensengupyourtensionlinkthefollowingpointsshouldbeacknowledged:
• Thezeroloadoutputgivenonthecalibraoncercateistheoutputofthetensionlinkwhennoloadis
applied.Thisincludestheremovaloftheloadcausedbyanyliingaccessories.
• Theloadonaninstalledtensionlinkwillcompriseoftheweightofyourassembly(includingsheaves,
blocks,shackles,ropes,hooksetc.)andtheacveload(loadlied).Therefore,theoutputwithnoacve
loadwillbegreaterthanthezerooutputindicatedonthecalibraoncercate.
ChecksAerInstallaon
• Withthetensionlinkinstalled,checktomakesurethatthedisplayedoutputisnotnegave,asthismay
indicateeitherafaultoracompressiveforceisbeingappliedtothetensionlink.SeeFigure2onprevious
page.
• Whenapplyingloadtothetensionlink,theoutputshouldincreaseintheposivedirecon.Usethe
calibraoncercateforreferenceastotheoutputobservedatcertainloads.
1.5 Calibraon
AllInterfacetensionlinkloadcellsarecalibratedintraceabletestmachinestobestsimulatenormalloading
condions.
Ourgoalistomatchtheloadingcondionsthatwouldbeexperiencedinservicebutitisnotpossibletototally
simulatetheon-sitestructureforeverytensionlinkmanufactured.Itisforthisreasonthatforopmum
systemaccuracy,acalibraoninthenalassemblyisrecommended.On-sitecalibraonshouldbeperformed
withtheinstrumentthatisbeingusedwiththistensionlinkloadcell.
1.6 Warnings / Hazards
Tensionlinksarehighlystresseddevicesandcommonlyhavesafetyfactorsbetweenthreeandvemes
theratedcapacityunderstaccondions.Fagueapplicaonsandenvironmentalfactorscancontributeto
reducingthismargin.Theusershoulddeterminemediaeectsontheexposedtensionlinkmaterials.Wherea
corrosiveenvironmentispresent,tensionlinkscanoenbemanufacturedfromcorrosionresistantmaterials
or,alternavely,isolaonbarrierscanbeemployedbetweenthecorrosiveenvironmentandthetensionlink.

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 4 of 6
Thefollowingpointsshouldbefollowedtoavoidpotenallyhazardoussituaons:
• Donotweldneartoinstalledtensionlinks,asleakagecurrentsmaydestroythetensionlink'selectric
circuits.
• Tensionlinksaresealedunitswhichmustnotbedismantled.Damagedtensionlinksshouldbereturnedto
Interfaceforrepairandre-calibraon.
• Theaccuracyofthesystemisdependentuponcorrectinstallaonofthetensionlink.
• Tensionlinkloadcellsmustnotbesubjectedtoshockloads,suchasusingahammertoforceanassembly
together(ngclevispinsintothemounngholes).
• Thetensionlinkloadcellshouldneverbeplacedinapotenalexplosiveenvironmentunlesstheproductis
suitablycered(ATEXorIECEx).
1.7 InspeconandRepair
Repair
InterfacereccomendsthatallpreparedandserviceoftensionlinkloadcellsbeperformedbyInterface.
Inspecon
AllInterfacetensionlinkloadcellsshouldbesubjecttoperiodicinspecon,whichshouldinclude,butisnot
exclusivetothefollowingchecks:
• Compleonofthesafetychecksaerinstallaon.
• Checkoutputatzeroload(shiinzerooset).Verifyagainstcalibraoncercate.
• Inspecttoseeifthetensionlinkhasbeendamaged/wornorchemicallyaacked(fromacorrosive
environmentorlubricantsetc.).
• Aeranyseriousoperangincident,repeattherstthreechecksabove.
• Fortensionlinksedwithatelemetrymodule,checkthatthebaeriesarecorrectlyinstalled.The
baeryholdershowspictoriallythecorrectorientaon.
• Fortensionlinksedwithatelemetrymodule,checkforanysignsofwateringresstothebaery
compartmentandforanybaerycorrosion.
• Intheunlikelyeventofthisdevicefailing,tnewbaeries(ifapplicable)andre-test.Onlywhenthishas
beendoneshouldyoureportthefault.Whenreporngthefault,giveafulldescriponoftheproblemand
thetypeofapplicaonthedeviceisbeingusedfor.

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 5 of 6
• Fortensionlinksedwithatelemetrymodule,checkforanysignsofwateringresstothebaery
compartmentandforanybaerycorrosion.
• Intheunlikelyeventofthisdevicefailing,tnewbaeries(ifapplicable)andre-test.Onlywhenthishas
beendoneshouldyoureportthefault.Whenreporngthefault,giveafulldescriponoftheproblemand
thetypeofapplicaonthedeviceisbeingusedfor.
Loadmeasuringlinksaredesignedformanydiverseliingandweighingapplicaons.
Telemetry
TheWTSproductrangeuseshighperformancetwo-wayradiocommunicaon.Eachtensionlinkedwiththe
telemetrymodulerequireseitheraWTShandhelddevice,adigital/analogueinterface,orabasestaonandPC
tocommunicatewith.SeetheWTSUserManualforfurtherdetailsontheWTSrangeofproducts:
hp://www.interfaceforce.com
IF IN DOUBT ABOUT ANY ASPECT OF THE SELECTION,
INSTALLATION OR USE OF A TENSION LINK,
CONTACT INTERFACE FOR ADVICE BEFORE INSTALLING
CE Approvals
EuropeanDirecve 2006/42/EC
BS-ENISO13849-1:2015
BS-ENISO13849-2:2015

7418 East Helm Drive • Scosdale, Arizona 85260 • 480.948.5555 • www.interfaceforce.com
Operator Instrucons WTSTL Tension Link v3.1 12-01-2017
Page 6 of 6
WARRANTY
WARRANTY
AlltensionlinkloadcellproductsformInterfaceForceInc.,('Interface')arewarrantedagainstdefecve
materialandworkmanshipforaperiodof(1)oneyearfromthedateofpurchase.
Ifthe'Interface'productyoupurchaseappearstohaveadefectinmaterialorworkmanshiporfailsduring
normalusewithintheperiod,pleasecontactyourDistributor,whowillassistyouinresolvingtheproblem.Ifit
isnecessarytoreturntheproductto'Interface'pleaseincludeanotestangname,company,address,phone
numberandadetaileddescriponoftheproblem.Also,pleaseindicateifitisawarrantyrepair.
Thesenderisresponsibleforshippingcharges,freightinsuranceandproperpackagingtopreventbreakagein
transit.
'Interface'warrantydoesnotapplytodefectsresulngfromaconofthebuyersuchasmishandling,improper
interfacing,operaonoutsideofdesignlimits,improperrepairorunauthorizedmodicaon.
Nootherwarranesareexpressedorimplied.'Interface'specicallydisclaimsanyimpliedwarranesof
merchantabilityortnessforaspecicpurpose.Theremediesoutlinedabovearethebuyer'sonlyremedies.
'Interface'willnotbeliablefordirect,indirect,special,incidentalorconsequenaldamageswhetherbasedon
thecontract,tortorotherlegaltheory.
Anycorrecvemaintenancerequiredaerthewarrantyperiodshouldbeperformedby'Interface'approved
personnelonly.
Table of contents