І. Application
The Electronic Differential Thermostat DT-3 is designed to control the operation of the circulation pump and
electrical heating elements of the water heater in relation to the temperature difference between the solar panel (fireplace) and
the water heater.
ІІ. Elements for indication, settings and signalization
The main elements for indication, settings and buttons are shown bellow (see Figure 1)
Figure.1
ndications
1 digital display indication
2 indication for a switched on circulation pump
3 indication for a low solar panel temperature
4 button for switching over the digital display indication between solar panel and water heater tempereature
5 button for indication of the adjusted temperature difference between the solar panel and the water heater
6 knob for adjusting the temperature difference between the solar panel and the water heater
ІІІ. Operation
The Еelectronic Differential Thermostat DT-3 controls the solar panel (fireplace) and the water heater temperature by
means of two sensors. f the temperature difference between them is within the range of 2….20
0C (adjusted by means of
element 6, see Figure 1) in favor of the solar panel (fireplace), the circulation pump will start working until both temperatures
will be equalized. The pump operation is being shown by a light indication marked with “pump” symbol (see position 2 of
Figure 1).
When the solar panel temperature is lower than 40 0C, the Differential Thermostat DT-3 will not allow the circulation
pump to operate and that state is being shown by a light indication for a low solar panel temperature (position 3 of Figure 1).
When no one button is pressed the digital dispaly shows the solar panel temperature (fireplace) and after pressing the
button for switching over the digital dispaly state (position 4 of Figure 1) the water heater temperature will be indicated.
The temperature difference (from 2 0 up to 20 0C) can be fixed by pressing the button for indication of the adjusted
temperature difference (position 5 of Figure 1) and by turning the knob for adjusting that temperature difference (position 6 of
Figure 1), thus selecting its value from 2 up to 20 С.
Technical data
Supply voltage: 230V/ АС /50Hz
Maximal rated current of terminals: 10А/250V
nputs: 2 temperature sensors LM335
Outputs: 1 standard relay (changeover contacts)
Switch-on difference: ΔT 2…20 С adjustable
Water temperature that blocks the system: 40 С (2 С)
Range of temperature measuring: от -40 до +100 С
tel.:00359 596 333 66 ||| fax:00359 596 3 5 80 ||| info@intiel.com ||| www.intiel.com
9 Peter Beron Str, Pomorie 8000, Bulgaria
2