Invacare Scanbeta NG User manual

©2016Invacare®Corporation
Allrightsreserved.Republication,duplicationormodificationinwholeorinpartisprohibitedwithoutpriorwritten
permissionfromInvacare.Trademarksareidentifiedby™and®.AlltrademarksareownedbyorlicensedtoInvacare
Corporationoritssubsidiariesunlessotherwisenoted.
ThisbedhasbeentestedandapprovedaccordingtoNordicRequirements,adjustablebedsforchildren.
ThisbedhasundergoneariskanalysisaccordingtoENISO14971.
InvacareiscertifiedaccordingtoISO9001andISO13485.

Contents
1General........................................4
1.1Aboutthismanual..............................4
1.2IntendedUse..................................4
1.3Servicelife....................................4
1.4Warranty....................................4
1.5Limitationofliability.............................4
2Safety..........................................5
2.1Generalsafetyinformation........................5
2.2Labelsandsymbolsontheproduct..................5
2.2.1Productlabel...............................5
2.2.2Otherlabelsandsymbols......................6
3Setup..........................................7
3.1Receivingthebed...............................7
3.2Mainpartsofbed...............................7
3.3Assemble/Disassemblethebed....................7
3.3.1Mountingthebedends........................7
3.3.2Mountingthesiderails........................8
3.3.3Mountingtheliftingpole.......................9
4Operatingthebed................................10
4.1GeneralSafetyInformation........................10
4.2Operatingsiderails.............................10
4.2.1Operatingtheloweringsiderail..................10
4.2.2Operatingtheopening/foldablesiderail............10
4.2.3Operatingchildsafetylatch.....................11
4.3HandcontrolHL81/HL82/HL84..................11
4.3.1Lockingfunction.............................11
4.4Operatingthecastorbrakes.......................11
4.4.1Operatingcastorswithoutcentralbrakingsystem.....12
4.4.2Operatingcentralbrakingsystem.................12
4.5Operatingtheliftingpole.........................12
4.6Manualpositioningofthelegsection.................13
4.7Emergencyreleaseofthebackrestorthigh/legsection....13
5Accessories.....................................14
5.1Accessorieslist................................14
5.2Mattresses....................................14
6Maintenance....................................15
6.1Generalservicinginformation......................15
6.1.1Checklist-Maintenance.......................15
6.2Cleaning.....................................15
6.3Lubrication...................................15
6.4Inspectionafterrelocation-Preparefornewuser.......15
6.5Dismountingthemotor..........................16
6.6Dismountingthemattresssupport..................16
6.7Dismountingthesheararmsfromthebase............17
7AfterUse.......................................18
7.1Wastedisposal................................18
8Troubleshooting.................................19
8.1Troubleshootingelectricalsystem...................19
9Technicaldata...................................20
9.1Dimensionsbed................................20
9.2Weights.....................................20
9.3Dimensionsmattresses..........................20
9.4Environmentalconditions.........................20
9.5Electricaldata.................................20
9.6Electromagneticcompliance(EMC)..................21

Invacare®ScanbetaNG™
1General
1.1Aboutthismanual
Thisusermanualcontainsimportantinformationaboutthehandling
oftheproduct.Inordertoensuresafetywhenusingtheproduct,
readtheusermanualcarefullyandfollowthesafetyinstructions.
Allindicationsofrightandleftarebasedonauserlyingonhisback
inthebed.
Pleasenotethattheremaybesectionsinthisusermanual,whichare
notrelevanttoyourproduct,sincethismanualappliestoallexisting
modules(onthedateofprinting).
Ifaproblemshouldariseinconnectionwiththedeliveredproduct,
pleasecontactyourInvacare®supplier.Anaddresslistisshownon
thebacksideatthismanual.
Symbolsinthismanual
Inthisusermanual,warningsareindicatedbysymbols.Thewarning
symbolsareaccompaniedbyaheadingthatindicatestheseverity
ofthedanger.
WARNING
Indicatesahazardoussituationthatcouldresultin
seriousinjuryordeathifitisnotavoided.
CAUTION
Indicatesahazardoussituationthatcouldresultin
minororslightinjuryifitisnotavoided.
IMPORTANT
Indicatesahazardoussituationthatcouldresultin
damagetopropertyifitisnotavoided.
TipsandRecommendations
Givesusefultips,recommendationsandinformation
forefficient,trouble-freeuse.
ThisproductcomplieswithDirective93/42/EEC
concerningmedicaldevices.Thelaunchdateofthis
productisstatedintheCEdeclarationofconformity.
1.2IntendedUse
Thebedhasbeendevelopedfordomesticcareandlongtermcare:
•Applicationenvironment3;Long-termcareinamedicalareawhere
medicalsupervisionisrequiredandmonitoringisprovidedif
necessaryandmedicalelectricalequipmentusedinmedical
proceduresmaybeprovidedtohelpmaintainorimprovethe
conditionofthepatient.
•Applicationenvironment4;Careprovidedinadomesticarea
wheremedicalelectricalequipmentisusedtoalleviateor
compensateforaninjury,disabilityordisease.
•Thebedisintendedfordisabledchildrenwithlimitedmobility,
from3–12yearsofageandsizeof92–155cmsize.
•Thebedisnotintendedfortransportationofusers.Itismobile
withinaroomwithapatientinit.Castorsarelockable.
•Thebedisnotintendedforpsychiatricpatients.
•Maximumuserweightandsafeworkingloadarelistedonthe
productlabelandinthetechnicaldatasectioninthismanual.
WARNING!
–Anyotherorincorrectusecouldleadtohazardous
situations.
1.3Servicelife
Theexpectedservicelifeofthisproductiseightyearswhenused
dailyandinaccordancewiththesafetyinstructions,maintenance
intervalsandcorrectuse,statedinthismanual.Theeffectiveservice
lifecanvaryaccordingtofrequencyandintensityofuse.
1.4Warranty
Thewarrantycoversallmaterialandproductiondefectsfortwo
yearsfromthedateofdelivery,provideditcanbedemonstratedthat
suchdefectswerepresentbeforedelivery.Allmanufacturingfaultsor
defectsmustbepromptlyreported.
Invacare®mayrepairthefaultorreplacethecomponent.The
warrantyprovidedbyInvacare®doesnotcoveradditionalcosts
(transport,packaging,labour,sundryexpenses,etc.areforthe
customer’saccount).
Thewarrantydoesnotcover:
•Damagecausedduringtransportthatisnotdirectlyreportedto
theforwarderatthemomentofdelivery.
•Repairsperformedbyunauthorizedcentersandpersonnel.
•Partssubjecttonormalwear.
•Maliciousdamagesordamagedcausedbyimproperuseofthe
bed.
1.5Limitationofliability
Invacareacceptsnoliabilityfordamagearisingfrom:
•Non-compliancewiththeUserManual
•Incorrectuse
•Naturalwearandtear
•Incorrectassemblyorset-upbythepurchaserorathirdparty
•Technicalmodifications
•Unauthorizedmodificationsand/oruseofunsuitablespareparts
AwrittenauthorizationofInvacaremustbeobtainedbeforeinstalling
additionaladaptationsonthisInvacareproduct.Otherwisenoliability
claimscanbemade.
41570628-B

Safety
2Safety
2.1Generalsafetyinformation
WARNING!
Riskofentrapment/suffocation/strangulation
There’sariskofentrapmentbetweenmattresssupport,
siderail,bedendand/ormovingparts(e.g.sheararms).
–Thebedmustnotbeusedbypersonsunder3yearsof
age,orwithabodysizesmallerthananaverage3year
old(over92cmlength).
WARNING!
Riskofpatientsslippingthroughtheopenings
Thebedfulfilsallrequirementsregardingmaximum
distances.However,itispossiblethatpatientswithsmall
bodydimensionsslipthroughtheopeningsbetweenthe
siderailsorthroughtheopeningbetweenthesiderail
andthemattresssupport.
–Payspecialattention,ifthebedisusedforthecareof
patientswithsmallbodydimensions.
WARNING!
Riskduetoelectromagneticinterference
Electromagneticinterferencebetweenthebedandother
electricalproductscanoccur.
–Toreduceoreliminatesuchelectromagnetic
interference,increasethedistancebetweenthebed
andtheproductsorswitchthemoff.
Thismedicalbedcanbeusedtogetherwith
medicalelectricalequipmentconnectedtotheheart
(intracardially)orbloodvessels(intravascularly)provided
thatfollowingpointsarerespected:
–Thebedshouldbeequippedwithmeansforpotential
equalizationconnectionmarkedoutbyasymbol
showninthebackofthismanual.
–Medicalelectricalequipmentshouldnotbefixedon
thebed’smetallicaccessoriessuchassiderails,lifting
pole,driprod,bedends,etc.
–Themedicalelectricalequipmentpowersupplycord
shouldbekeptclearoftheaccessoriesoranyother
movingpartsofthebed.
WARNING!
Riskofinjuryordamagetoproperty
–Donotrollthecastorsoverthemainpowercord.
–Donotbringmainpowercordintomovingparts.
–Disconnecttheplugfromthemainsbeforemoving
thebed.
–Makesurethatnowires(mainsorfromother
equipment)arejammedordamaged,whenthebedis
used.
–Keepbedcomponentsandaccessoriesatleast30cm
awayfromaheatedsurfaceandnotindirectsunlight.
CAUTION!
Riskofinjury
Thereisariskofentrapmentoffingersinthebedmoving
parts.
–Payattentiontoyourfingers.
CAUTION!
–Forauserenteringorexitingthebed,alwayslower
thebedtoanappropriateheight.Thebackrestcan
beusedasasupport.Makesure,thethigh-andleg
sectionishorizontaltoavoidoverloadingthemattress
support.
–Alwayslowerthebedtothelowestpositionbefore
leavingthepatientinthebedunattended.
–Makesurethatthereisnothingunder,over,ornear
thebedthatcanobstructtheheightadjustment,like
forexamplefurniture,liftsorwindowframes.
Safetyinregardsofchildren
WARNING!
Riskofentrapment
Whenliftingorloweringthebed,there’sariskof
entrapmentbetweenmattresssupport,sheararmsand
baseframe.
–Neverleavechildrenunattendedplayingaroundthe
bed.
–Donotallowchildrentolingerunderthebed.
–Whenliftingorloweringthebed,alwaysmakesure
thatthereisnochildrennearthebedmovingparts.
–Thehandcontrolmustnotbeusedbychildren.When
thehandcontrolisnotusedkeepitoutofreachfor
children.
2.2Labelsandsymbolsontheproduct
2.2.1Productlabel
Xxxxxxxxxxx
= xxx kg
XXX XX XXX XXXX XX
XXX XXXXX X XXX
XX X XXX XXXXX XXXX
XXXX XX XX XXXX
= xxx kg
YYYY-MM
Invacare ReaAB
Växjövägen 303
34375 Diö - Sweden
XXXXXX XXXXX_XX
XXXXXXXXXXXXX
EN 60601-2-52
HMI: 79007
Theproductlabelisplacedontheframeofthebedandcontainsthe
mainproductinformation,includingtechnicaldata.
Symbols
SerialNumber
ReferenceNumber
ManufacturerAddress
ManufacturingDate
1570628-B5

Invacare®ScanbetaNG™
Max.UserWeight
Max.SafeWorkingLoad
CLASSIIequipment
TypeBAppliedPart
WEEEconform
ThisproductcomplieswithDirective93/42/EEC
concerningmedicaldevices.
Abbreviationsfortechnicaldata:
•Iin=IncomingCurrent
•Uin=IncomingVoltage
•Int.=Intermittence
•AC=AlternatingCurrent
•Max=maximum
•min=minutes
Formoreinformationabouttechnicaldata,referto9Technicaldata,
page20.
2.2.2Otherlabelsandsymbols
RefertoUserManual
61570628-B

Setup
3Setup
3.1Receivingthebed
Whenyoureceivethebed,checkthepackaging.Ifthebedshowsany
signsofdamageupondelivery,pleasereadSectionWarranty.
WARNING!
Riskofpersonaldamage
Thereisariskofentrapmentorsqueezing,while
assemblingordisassemblingofthebed.
–Theassemblyofthebedandmountingofaccessories
mustbedonebyauthorizedortrainedpersonnel.
–Followinstructionscarefully.
IMPORTANT!
–Toavoidcondensationthebedshouldnotbeused
untilithasreachedatemperatureof10-40°C.
IMPORTANT!
–Aftereachassembly,checkthatallfittingsareproperly
tightenedandthatallpartshavethecorrectfunction.
WARNING!
–Thestandardelectricalequipmentmustnotbe
combinedwithelectricalequipmentthatisnot
designedforthisbed.
3.2Mainpartsofbed
•Thebedcanbeequippedwithdifferentsiderailson
rightandleftsides.
•Thebedmustalwayshavebothbedendsmounted.
C
D
E
F
G
A
B
B
Bedparts:
AMattresssupportELoweringsiderail
BBedendattachmentsFOpeningsidepanels
CFixedsiderailGFoldingsidepanels
DBedendplates
Therearealsosidepanelswith:
•Woodentrims
•Acrylicglass
3.3Assemble/Disassemblethebed
CAUTION!
Riskofpinching
–Makesurenofingersarepinchedduringassembly/
disassemblyofthebed.
IMPORTANT!
Afterassembly
Tightenallscrewsandcheckthatallpartsareproperly
alignedwitheachotherandthatthebedisstable.
–Thebedendattachmentsmustbeadjustedforcorrect
fitwhenmountingtheselectedsiderails.
3.3.1Mountingthebedends
TheAllenkeytouseforassemblingthebedendsisattached
ontheinsideofthebaseframe(headend).
1570628-B7

Invacare®ScanbetaNG™
Bedendattachments
1
4 x
8 x
A
B
C
2
1.Insertthebedendattachmentsintheinsertpipesonthe
mattresssupport.
2.InsertthescrewsAandBineachcorner.Leanthebedend
attachmenttowardsthebedandtightenscrewA.
DonottightenscrewBuntilthesiderailsarefittedandadjusted
correctly.KeepscrewsCforthesiderailmounting.
Bedendplates
1.Inserttheinnerscrewsontopofeachbedendattachment.
2.
FittheU–fittingsinthecornersofthebedendplateandmake
suretheyarefittedovertheholes.
3.Placetheholesofthebedendplateovertheguidepinsonthe
mattresssupport.Foldtheplatein,whilegentlypushingitdown.
4.Attachthebedendplatewiththescrewsontopofthebed
endattachments.
3.3.2Mountingthesiderails
Aftermountingthesiderails:Makesurethatthebedend
attachmentsarestraightandtightenthescrewsonthebed
endproperly.
Fixedsideandopening/foldingpanel
D
C
B
4 x
1.Fittheguidepinsonthemattresssupportintothebrassbushings
onthesiderail.
2.Foldthesiderailin,whilegentlypushingitdown.
3.Attachthesiderailwiththescrewsontopofthebedend
attachments.
Functionalcheck:
Aftermountingofopening/foldingsiderails:Checkifthesiderailsare
straightandopenandclosewithoutjamming.
1.Siderailsopenandclosewithoutjamming:
a.TightenscrewCuntilittouchesthebottomofthesidetube
ineachcorner.
b.TightenscrewBineachcorner.
2.Siderailsdonotopenandclosewithoutjamming:
a.Toalignthebedendattachment,tightenscrewCslightly.
b.Checkagain,ifthesiderailsopenandclosewithoutjamming.
Repeatstepaifrequired.
c.TightenscrewBineachcorner.
Loweringside
2
2
4 x
12
1.Attachthewoodenbar,withthescrews,ontheframeofthe
mattresssupport.
2.Putthecornertrimsontheguidepinsinthecornersandattach
thembytighteningthescrewsontopofthebedendattachments.
Makesurethatthetracesonthetrimsarepointinginwards.
81570628-B

Setup
3.
3
3
Pressinthelockingpinsonthesides,atthesametimeorone
sideatatime.
4.
55
44
Inserttheguidewaysintothetracesofthecornertrims.Release
thelockingpin(s)whentheyareabovethemattresssupport.If
youaredoingonesideatatime,makesurebothsidesarein
placebeforemovingontothenextstep.
5.Pullouttheblackcotterpinsandpullthegatefirstpastthelower
andthenpasttheupperlockingposition.
6.Releasethecotterpinswhenthegateisallthewayup.
IMPORTANT!
Aftermountingoftheloweringside
–Checkthatthesideraillocksproperlyinboth
positions.
–Checkthatthelockingpinsarecompletelyout,
otherwisethegatecanfallout.
Dismountingbedsiderails
Followinstructionsformounting,butinreversedorder.
Beforedismountingthesiderail
•Raisethebedtocreateenoughspacebetweenthe
mattresssupportandthefloor,tomakespaceforthe
siderailtopassunderneath.
3.3.3Mountingtheliftingpole
1.2.
3. 4.
H
1.Dismountthebedendplate.Seeinstructionformountingof
bedendplate;section3.3.1Mountingthebedends,page7and
followinreversedorder.
2.Attachthebracketoftheliftingpoleonthemattresssupport
frameandtightenthescrews.
3.Mountthebedendplateagain.
4.Fittheliftingpolepostintothebracketandtightenthescrew
tofixthepole.
1570628-B9

Invacare®ScanbetaNG™
4Operatingthebed
4.1GeneralSafetyInformation
WARNING!
Riskofpersonalinjuryanddamagetoproperty.
–Thebedmustbeplacedsothattheheightadjustment
isnotobstructedby,forexample,liftsorfurniture.
–Takecarethatnobodypartsarebeingsqueezed
betweenfixedparts(suchassiderails,bedendsetc)
andmovingparts.
–Thehandcontrolmustnotbeusedbychildren.
WARNING!
Riskofinjury
Ifthebedisusedbyconfusedorrestlessusersorusers
withspasms:
–either,whenthebedisequippedwithalockablehand
control,lockthehandcontrolfunctions,
–ormakesurethatthehandcontrolisoutofreachfor
theuser.
4.2Operatingsiderails
WARNING!
Riskofentrapmentorsuffocation
There’sariskofentrapmentorsuffocationbetween
mattresssupport,siderailandbedend.
–Alwaysensurecorrectfittingofthesiderails.
4.2.1Operatingtheloweringsiderail
CAUTION!
Riskofpersonalinjury
Iftheloweringsidefallsdownitcancauseminorinjuries
toe.g.feet.
–Alwaysholdthesideinafirmgripwhile
raising/lowering.
–Checkthattheblackcotterpinsarecompletelyout
andlockingaftereveryheightadjustmenttotheside
rail.
A A
B
Up/Down
1.PullouttheblackcotterpinsAonbothsides.
2.Pull/pushthesiderailBupordownwithbothhandsandrelease
thecotterpinsA.
3.Whenthesiderailisintheupperorlowerpositionthecotter
pinswilllockautomaticallyinthewoodentrims.
Whenloweringthesiderailfromupperposition;startby
liftingitslightlybeforetheblackcotterpinsarepulledout.
4.2.2Operatingtheopening/foldablesiderail
KG
WARNING!
Riskoftipping
Thebedcantipwhenthesideraildoorsareopen.
–Donotputanyweightonthedoors.
–Neverexceedthemaximumangleof90°,when
openingthedoors.
CAUTION!
Riskofpinching
–Becarefulnottopinchfingerswhenopeningand
closingthedoors.
101570628-B

Operatingthebed
4.2.3Operatingchildsafetylatch
WARNING!
Riskoffallingoutofbed
–Alwayscheckthatthechildsafetylatchisproperly
engagedafterclosingthedoor.
•Openingandfoldingsiderailsareequippedwithchildsafety
locks.
•Dependingontheheightofthesiderailthebedshaveadifferent
numberoflockingpins.
Lockchildsafetylatch
1
2
3
1.Pulluptheblackcotterpins,onthebottomlathofthesiderail
(oneoneachdoor).
2.Closethedoorsandmakesurethecotterpinsclickintothe
holesonthelath.
3.Pushtherailonthesafetylocktoonesideuntilitlockswith
aclick.
Unlockchildsafetylatch
1
2
3
4
1.Pulldowntheblackcotterpin,underneaththeupperlathofthe
siderail.
2.Pushtherailonthesafetylocktooneside.
3.Pulluptheblackcotterpinsonthebottomlathofthesiderail
(oneoneachdoor).
4.Openthedoors.
4.3HandcontrolHL81/HL82/HL84
Thehandcontrolcanbeequippedwitheitherone,twoorfour
buttons.
Sittingposition
(HL84)
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
Backrestsection
(HL82/HL84)
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
Thighsection
(HL84)
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
Heightadjustment
(HL81/HL82/HL84)
1.Up:pressleftsideofthebutton(p).
2.Down:pressrightsideofthebutton(q).
4.3.1Lockingfunction
Thelockingfunctionpreventsusageofcertainfunctionbuttons.
Regardlessofhowmanybuttonsyourhandcontrolhas,theycan
allbelockedindividually.
1.InsertkeyAinthekeyhole,belowthewantedfunction.
2.Tolock,turnthekeyclockwise.
3.Tounlock,turnthekeyanticlockwise.
4.4Operatingthecastorbrakes
CAUTION!
Riskoftrapping
–Donotreleasethebrakewiththefingers
CAUTION!
Riskoffalling
Usercanfall,whileenteringorexitingthebed,ifbrakes
arenotactivated.
–Alwaysapplythebrakeswhenuserismovinginorout
ofbedorwhenattendingtothepatient.
Set-offfromthecastorsmightunderspecialconditions
appearatdifferenttypesofabsorbingfloorcoveringincluding
untreatedorbadlytreatedfloors.Inmattersofdoubt,it’s
recommendedtoplaceasuitablekindofprotectionbetween
thecastorsandthefloor.
1570628-B11

Invacare®ScanbetaNG™
4.4.1Operatingcastorswithoutcentralbraking
system
Lockingthebrake
StepontheouterpedalA.
Releasingthebrake
StepontheinnerreleasebuttonB.
4.4.2Operatingcentralbrakingsystem
Lockthebrake
Steponthepedalandpressit
downtoitslowestpoint.
Releasethebrake
Placethefootunderneaththe
brakepedalandpushthepedal
uptoitshighestpoint.
4.5Operatingtheliftingpole
WARNING!
Riskofinjury
Thebedcantipifthehandleisused,whiletheliftingpole
isturnedawayfromthebed.
–Theliftingpolealwayshastobepositionedwiththe
handlehangingoverthebedarea.
–Donotexceedthemaximumloadoftheliftingpole;
70kg.
Changeheightoftheliftingpolehandle
Lowerthehandle
1.
Pullthecordouttotheside,toreleaseitfromthelocking
mechanism.
2.Keepthecordouttothesideandslidetheplasticcordlock
upwards.
Raisingthehandle
1.
Slidethecordlockdownwards.
Lockthehandle
1.
Lockthecordlockbypullingthehandledownwards.
IMPORTANT!
Afteradjustmentoftheliftingpolehandle
–Pullthehandletomakesurethecordlockhasbeen
engaged.
–Thetwocordsabovethecordlock,mustbeparallel,
tolockproperly.
121570628-B

Operatingthebed
4.6Manualpositioningofthelegsection
Up–fromhorizontalposition
1.Liftthelegsectionuptodesiredheight.
2.Lowerituntilitstaysinafixedposition.
Down–fromupperposition
1.Liftthelegsectionuptoitshighestpositionandunhookitwitha
littlejerk.
2.Sinkthelegsectionallthewaydown.
4.7Emergencyreleaseofthebackrestor
thigh/legsection
Anemergencyreleaseofthebackrestorthigh/legsectioncouldbe
necessaryinthecaseofpower-ormotorfailure.
CAUTION!
Riskofinjury
–Aminimumoftwopersonsarerequiredtorelease
amattresssection.
–Anemergencyreleaseoftheheightadjustmentis
NOTpossible.
–Removetheplugfromthemainssocketbefore
emergencyreleaseofthemattresssupport.
1.Bothpersonsholdthemattresssection.
2.
Oneofthempullsoutthecotterpin(fromthemotorin
question).
3.Bothpersonsslowlylowerthemattresssectionuntilitis
completelydown.
1570628-B13

Invacare®ScanbetaNG™
5Accessories
5.1Accessorieslist
•Liftingpole
•Upholstery
•Supporthandle
•Sidepanelswithwoodentrims
•Sidepanelswithacrylicglass
•Stickers
IMPORTANT!
–Useonlyoriginalaccessoriesandspareparts.Spare
partslistsandextrausermanualscanbeorderedfrom
Invacaresalescompanies(seeaddressesandwebsites
onthebackpageofthisusermanual).
Thetoolsnecessaryformounting/dismountingtheaccessoriesof
thebedare:
•oneAllenkey(useformounting/dismountingallfittings)
•oneadjustablespanner
TheAllenkeyiskeptonthebaseframeattheheadend.
5.2Mattresses
WARNING!
Safetyaspectsregardingcombinationofsiderails
andmattresses:
Togetthehighestpossiblesafetylevel,whenusingside
railsonthebed,theminimumandmaximummeasures
formattresses,mustberespected.
–Forcorrectmattressmeasuresseemattresstablein
chapter9Technicaldata,page20.
WARNING!
Riskofentrapmentand/orsuffocation
–Theusercouldgettrappedand/orsuffocate,ifthe
horizontalspace,betweenthemattresssideandthe
insideofthesiderail,istoobig.Followtheminimum
width(andlength)ofmattressesincombinationwith
asiderail,asstatedinthemattresstableinchapter
9Technicaldata,page20.
–Beawarethatusingverythickorsoftmattresses(low
density),oracombinationofthese,increasestherisk.
A
WARNING!
Riskoffalling
Theusercanfallovertheedgeandgetseriouslyinjured,
iftheverticaldistanceAbetweenthetopofthemattress
andtheedgeofthesiderail/bedend,istooshort.See
imageabove.
–AlwayskeepaminimumdistanceAof22cm.
–Followthemaximummattressheightincombination
withthesiderailasstatedinthemattresstablein
chapter9Technicaldata,page20.
141570628-B

Maintenance
6Maintenance
6.1Generalservicinginformation
IMPORTANT!
–Themattresssupportmustbesupportedduring
serviceinspections,topreventaccidentallowering.
–Onlypersonnelwhohavereceivedthenecessary
instructionsortrainingmayperformserviceand
maintenanceofthebed.
–Afterreconditioningthebed,orifbedfunctions
change,servicemustbecarriedoutaccordingtothe
checklist.
Aservicecontractcanbemadeinthecountries,whereInvacare®has
itsownsalescompany.IncertaincountriesInvacare®offerscourses
inserviceandmaintenanceofthebed.Sparepartslistsandadditional
usermanualsareavailablefromInvacare®.
BeforeUse
•Ensurethatallmanualandelectricalpartsfunctionscorrectly
andareinasecurestate.
•Check,byraisingandloweringthebed,thatthesheararmsrun
smoothlyintheguideways.
Afterthreemonths
•Ensurethatallmanualandelectricalpartsarefunctioning,and
tightenbolts,screws,nuts,etc.
Everyyear
•Werecommendasafetytestcomprisingthemotors’
performanceandmechanicalstate.
Everysecondyear
•Westronglyrecommendaserviceaccordingtothebelow
checklistaftertwoyearsofnormaluseandtheneverysecond
year.
Motors,handcontrolandcontrolunitsareservicedby
exchangingthefaultypart.
6.1.1Checklist-Maintenance
Checkpoints
qCirclips,cotterpinsandplasticfixingring-properlylockedand
intact.
qScrews-tightened.
qWeldings-intact.
qChecktheguideways-nobending.
qSideraillockingandmovingsystem-properlylockingand
runningsmoothly.
qCastorfittings-tightened.
qCastorbrakes-lockingproperly.
qHeightadjustmentmotor-runningproperly.
qBackrestmotor-runningproperly.
qThighsectionmotor-runningproperly.
qLegsectionmotor-runningproperly.
qWires-correctlywiredandundamaged.
qElectricplugs-undamaged.
qCableinsulationandactuatorhousings–nocracksordamages.
qDamagedcoating-repaired.
qAccessories-correctlyassembledandcorrectfunction.
6.2Cleaning
Important
–Thebeddoesnottoleratecleaninginautomatic
washingplantsortheuseofwater-jetbasedcleaning
equipment.
–Makesurethatthepowerplugisremovedfromthe
mainsocketbeforecleaning.
–Makesurethatallplugsonthebedareinplace,during
washing.
ImportantdetailsforcleaningIPX4handcontrols
–Watermaybepressurised,butneverusehigh-pressure
cleaningorsteamcleaningdirectlyontheelectrical
parts.
•Thebedshouldbewasheddownusingawetsponge,clothor
brush.
•Useordinaryhouseholdcleaningagents.Neveruseacids,
alkalinesorsolventssuchasacetoneorcellulosethinner.
•Thebackrestandtheleg/thighsectionscanbeliftedfromthe
mattresssupport,whichfacilitatescleaningandaccesstothe
controlunit.
•Thehandcontrol,motorsandcontrolunitmaybewashedwith
brushandwater.
•Drythebedaftercleaning.
6.3Lubrication
Werecommendlubricatingthebedaccordingtothefollowingtable:
PartofbedLubricationmethod
Bearingsforlifting-andsheararmsOil(medicallyclean)
MotorsuspensionOil(medicallyclean)
GlidersandguidewaysGrease
Axlesandrollsforsheararm(axle
mustbedismounted)
Grease
Fororderingofcorrectoilandgrease,pleasecontactyour
Invacaredealer.
6.4Inspectionafterrelocation-Preparefornewuser
IMPORTANT!
Whenthebedhasbeenrelocated;beforegiventoanewuserithastobethoroughlyinspected.
–Inspectionmustbedonebyatrainedprofessional.
Checkpoints
Checkthatthelatches,lockingthemattresssupportonthesheararms,are
properlyengaged(redbuttononthemattresssupport).
Checkthelockingbetweenthesheararmsandthebedbase(pipepincorrectly
mounted).
Checkthelockingofthemotors(pipepinscorrectlymounted).
1570628-B15

Invacare®ScanbetaNG™
Checktheelectronicwiringforthemotors(wiresnotsqueezed).
Checkthattheenclosingofthemotorsareintact(nocracksthatenablesfluids
topierce).
Checkthesectionsofthemattresssupportbyusingthehandcontroltoactivate
allfunctionsofthemovingparts.
Checkthefunctionofthebrakes.
Checkthatthebedendattachmentsareproperlymounted(steady)andthat
thebedendsaresecurelyattached.
Checkthelockingfunction(s)ofthesiderails.
6.5Dismountingthemotor
IMPORTANT!
–Ifthebedisstandinguponitscastors,aminimumof
threepersonsareneededtodismountthemotorfor
heightadjustment.Twoneedtoholdupthemattress
supportwhileoneisdismountingthemotor.
–Asanoption,thebedcanbeputontheside.The
motorcanthenbedismountedbyonlyoneperson.
IMPORTANT!
Beforedismountingthemotor.
–Disconnectthebedfromthemainssocket.
–Disconnectallmotorcablesfromtheelectronics.
•Thelockcamovertheconnectors,ontheelectronics
box,mustberemovedbeforecontactscanbereleased.
•Certainmodelsalsohaveboltsonthemotors,which
needtobeloosened.
1.Pressthesnaplocks(oneineachendofthelockcam)witha
screwdriverandremovethecam.
2.Pulloutthemotorplugfromtheelectronics.
Dismountthemotor
1.Liftthebraceup,andfolditawayfromthecotterpin.
2.Pulloutthecotterpin.
3.Repeatthestepintheotherendofthemotor.
4.Removethemotor.
IMPORTANT!
–Keepafirmgripandbecarefulnottodropthemotor.
Mountthemotor
1.Placethemotorinitsinsertionplaceandpushthecotterpin
throughallholes.
2.Liftthebraceupandfolditoverthecotterpintolock.See
illustrationinsection“Dismountthemotor”.
Aftermountingthemotor
1.Putthemotorplugsbackintheelectronics.Eachsocket
ismarkedwithafunction.Makesureeveryfunctionis
connectedtotherightmotor.Ifyouarenotcertain
whichfunctionthemotorhas,thearticleNogivesmore
information.
2.Mountthelockcamandmakesureitissecuredwith
thesnaplocks.
3.Checkthatallmotorsandthehandcontrolhavecorrect
functionality.
6.6Dismountingthemattresssupport
IMPORTANT!
Beforedismounting/mounting
–Makesurethebrakesareactivated.
–Atleasttwopersonsareneededtodismount/mount
themattresssupport.Bothendsofthemattress
supporthavetobesupported.
450
A
Dismountingthemattresssupport
1.Disconnectthecablesbetweentheelectronicsandthemotors
tothesheararms.
2.ReleasethelatchesbypullingouttheredbuttonsAandturning
them45°clockwise.
3.Inthefootend;liftthemattresssupport,releasingitfromthe
buckles.
4.Intheheadend:pulloutthesheararmsglidingblocksfromthe
guidewaysonthemattresssupport.
5.Liftoffthemattresssupportfromthesheararms.
Mountingthemattresssupport
1.Liftthemattresssupportinoverthesheararms.
2.Liftthemattressslightlyinthefootendandgentlyslidetheshear
armsglidingblocksintotheguidewaysonthemattresssuport
(headend).
3.Gentlylowerthefootend,fittingthebucklesonthemattress
supportontheendsofthesheararmscrossbarandpressuntil
youhearaclickingsound.
4.Pluginthecablesfromthemotorstotheelectronics.
161570628-B

Maintenance
IMPORTANT!
Aftermounting
–Checkthatredbuttonsinthebucklesareinalocking
position.Ifnot;theredbuttonmustbeturned45°
counterclockwiseuntilitlocks.
6.7Dismountingthesheararmsfromthe
base
WARNING!
Iftheclamppartofthepipepinisdeformedit
mightnotlockproperly.
–Neverpulltheclamppartofthepipepin.
WARNING!
Ifthepipepinisnotcorrectlymounteditmight
open.
–Alwaysmountthepipepinwiththepinupwardsto
makesureitdoesnotloosenwhene.g.cleaningunder
thebed.
1.Lifttheloopofftheendofthepipepinandreleasetheclamp.
2.Pullthepinout,throughbothholesinthesheararm.
Mountthesheararms
1.Followtheinstructionabove(1–2)inreversedorder.
IMPORTANT!
Aftermountingofsheararms;beforeusingthelifting
mechanismofthebed:
–Ensurethatallfourplasticbushingsareintactand
correctlypositioned,betweensheararmandframe.
–Ensurethatthepipepinispushedcompletelythrough
bothholesandthattheclampisproperlyattached
overthepin.
1570628-B17

Invacare®ScanbetaNG™
7AfterUse
7.1Wastedisposal
Wastedisposal/recyclemustcomplywiththelawsand
regulationsforwastehandlingineachcountry.
Invacare®iscontinuouslyworkingtowardsensuringthatthe
company’simpactonenvironment,locallyandglobally,isreduced
toaminimum.
Wecomplywiththecurrentenvironmentlegislation(e.g.WEEE
andRoHSdirective).
WeonlyuseREACHcompliantmaterialsandcomponents.
•Allwoodenpartsmustbedismantledandsentforincineration.
•Allelectricpartsmustbedismantledandbedisposedofas
electriccomponents.
•Plasticpartsmustbesentforincinerationorrecycling.
•Steelpartsandcastorsmustbedisposedofaswastemetals.
IMPORTANT!
Accumulatorback-up
–OldaccumulatorsmustbereturnedtoInvacare®or
recycledascarbatteries
181570628-B

Troubleshooting
8Troubleshooting
8.1Troubleshootingelectricalsystem
SymptomPossiblecauseRemedy
MainsarenotconnectedConnectmains
Fuseinthecontrolunitisblown*Replacethecontrolunit
Mainsindicatordoesnotlightup
Controlunitisdefective*Replacethecontrolunit
Motorplugisnotfullyinsertedintothe
controlunit.
Insertthemotorplugproperlyintothe
controlunit
Themotorisdefective.*Replacethemotor
Motorcableisdamaged.*Replacethecable
Mainsindicatorlightsup,butthemotorisnot
running.Therelayinthecontrolunitmakesa
clickingnoise.
Controlunitisdefective*Replacethecontrolunit
Controlunitisdefective*Replacethecontrolunit
Mainsindicatorlightsup,butthemotorisnot
running.Norelaysoundisheardfromthe
controlunit.Handcontrolisdefective*Replacethehandcontrol
Controlunitisdefective*Replacethecontrolunit
Controlunitisinorderexceptforone
directionononechannel.Handcontrolisdefective*Replacethehandcontrol
Motorisrunning,butthepistonroddoesnot
move.
Themotorcannotliftfullload.
Motornoise,butnomovementofpistonrod.
Pistonrodoperatesinwardsandnot
outwards.
Motorisdamaged*Replacethemotor
*Serviceandmaintenanceofthebedmustonlybeperformedbypersonnelwhohavereceivedthenecessaryinstructionortraining.
Riskofpersonalinjuryanddamagetotheproduct.
–Thebedmustbeunpluggedfromthemainpowersourcebeforeopeningorrepairingelectricalparts.
WARNING!
Riskofpersonalinjuryanddamagetotheproduct.
–Thebedmustbeunpluggedfromthemainpowersourcebeforeopeningorrepairingelectricalparts.
1570628-B19

Invacare®ScanbetaNG™
9Technicaldata
9.1Dimensionsbed
•Allmeasurementsarestatedincm.
•Allanglesarestatedindegrees.
•Allmeasurementsandanglesarestatedwithouttolerances.
Invacare®reservestherighttochangethestatedmeasurementsand
angleswithoutwarning.
c e fd
b
g
a
h
i
j
k
l
ScanbetaNG™
60cm70cm80cm
a148168188
b136,4156,4176,4
c62,1567,1575,15
d71519
e21,222,227,15
f46,0552,0555,1
g151515
h30–90
i627282
j687888
k73°73°73°
l36°31°27°
9.2Weights
Bedsize60x14070x16080x180
Mattress
support
21kg31kg38kg
Basewith
shear
36kg47kg47kg
Woodenbed
end
11kg13,5kg14,5kg
Totalweight
bed
68kg91,5kg99,5kg
9.3Dimensionsmattresses
Bedsize(cm)Fixed,
Openingor
Foldingside
rails
Loweringside
railonboth
sideofbed
Loweringside
railonone
sideodbed
andFixed,
Openingor
Foldingside
railonthe
other.
140x6054x137x860x140x857x137x8
160x7064x157x870x160x867x157x8
180x8074x177x880x180x877x177x8
9.4Environmentalconditions
Storageand
transportationOperation
Temperature-10°Cto+50°C+5°Cto+40°C
Relativehumidity20%to75%
Atmospheric
pressure800hPato1060hPa
Beawarethatwhenabedhasbeenstoredunderlow
temperatures,itmustbeadjustedtooperatingconditions
beforeuse.
9.5Electricaldata
Voltage
supply
Uin230Voltage,AC,50/60Hz(AC=Alternating
current)
Maximum
current
input
Iinmax.1,5Ampere
Intermittent
(periodic
motor
operation)
10%2min/18min
Insulation
class
CLASSIIequipment
TypeB
AppliedPart
AppliedPartcomplyingwiththespecified
requirementsforprotectionagainstelectricalshock
accordingtoIEC60601-1.
Soundlevel55dB(A)
Degreeof
protection
Thecontrolunitandmotorsareprotected
accordingtoIPx6;theexternalpowersupplyand
thehandcontrolareprotectedaccordingtoIPx4.
ThelowestIP-classificationdecidestheoverall
classificationofthebed.
IPx4-Thesystemisprotectedagainstwater
splashedfromanydirection.
IPx6-Thesystemisprotectedagainstwater
projectedfromanydirection(nothighpressure).
201570628-B
Table of contents
Popular Baby & Toddler Furniture manuals by other brands

SAUTHON selection
SAUTHON selection HUGO HU031A Technical manual to keep

UPPAbaby
UPPAbaby remi 1601-REM-CA manual

MGA Entertainment
MGA Entertainment Little Tikes Dino Bouncer quick start

Badabulle
Badabulle B038202 instruction manual

Babyhug
Babyhug Windsor Wooden Cot & Bassinet user manual

Chipolino
Chipolino SWEET DREAMS Instructions for use