Invacare IRCPF16AW User manual

©2017InvacareCorporation
Allrightsreserved.Republication,duplicationormodicationinwholeorinpartisprohibited
withoutpriorwrittenpermissionfromInvacare.Trademarksareidentiedby™and®.Alltrademarks
areownedbyorlicensedtoInvacareCorporationoritssubsidiariesunlessotherwisenoted.
MakingLife’sExperiencesPossibleisaregisteredtrademarkintheU.S.A.

Contents
1General.........................................4
1.1Symbols.....................................4
1.2IntendedUse.................................5
1.3IndicationsforUse.............................5
1.4Contraindications...............................5
1.5T echnicalDescription............................5
2Safety..........................................7
2.1GeneralGuidelines.............................7
3Setup...........................................11
3.1Handling.....................................11
3.2TypicalSetup..................................11
3.3SetupWithoutaHumidierBottle..................13
3.4SetupWithaHumidierBottle....................14
3.5SettingtheFlowrateonthePediatricFlowmeter.......15
4AfterUse........................................16
4.1RecyclingInformation...........................16
5Technicaldata....................................17
5.1Specications.................................17
6Warranty........................................18
6.1LimitedWarranty..............................18

Invacare®PreciseRx™PediatricFlowmeter
1General
1.1Symbols
DANGER!
–Dangerindicatesanimminentlyhazardous
situationwhich,ifnotavoided,willresultin
deathorseriousinjury.
WARNING!
–Warningindicatesapotentiallyhazardous
situationwhich,ifnotavoided,couldresultin
deathorseriousinjury.
CAUTION!
–Cautionindicatesapotentiallyhazardous
situationwhich,ifnotavoided,mayresultin
propertydamageorminorinjuryorboth.
IMPORTANT!
–IMPORTANTindicatesahazardoussituation
thatcouldresultindamagetopropertyifitis
notavoided.
Givesusefultips,recommendationsandinformation
forefcient,trouble-freeuse.
GeneralWarningSign
Thebackgroundcolorinsidethe
triangleisyellowonproductlabels.
ReadManual
Thecolorofthesymbolbackgroundis
blueonproductlabels.
NoSmoking
Thecolorofthecirclewithdiagonal
barisredonproductlabels.
NoOpenFlame
Thecolorofthecirclewithdiagonal
barisredonproductlabels.
EuropeanCommunityRepresentative
Manufacturer
DateofManufacture
Recycle
ReferenceNumber
41150712-D

General
SerialNumber
IndoorUseONLY
DONOTuseoilorgrease
Keepdry
-29C
MIN
70C
MAX
TransportandStorageTemperature
InputFitting
OutputFitting
ThisproductcomplieswithDirective
93/42/EECconcerningmedicaldevices.
Thelaunchdateofthisproductisstatedin
theCEdeclarationofconformity.
1.2IntendedUse
ThePreciseRx™PediatricFlowmeterisintendedtoprovide
supplementaloxygentopatientswithlow-owprescriptions
inanon-acutesettingsuchasthehomeorlong-termcare
facility.Thedeviceisnotintendedtobelifesupportingor
lifesustaining.
WARNING!
RiskofInjuryorDamage
Useofthisproductoutsideoftheintendeduse
andspecicationshasnotbeentestedandmay
leadtoproductdamage,lossofproductfunction,
orpersonalinjury.
–DONOTusethisproductinanywayotherthan
describedinthespecicationsandintended
usesectionsofthismanual.
1.3IndicationsforUse
Toprovidesupplementaloxygentopatientswithlow-ow
prescriptionsinanon-acutesetting.
1.4Contraindications
Therearenoknowncontraindications.
1.5TechnicalDescription
Thedeviceisafreestanding,non-electricallypowered,
accessoryforconnectiontotheoutputttingofanInvacare
5literoutputoxygenconcentratorthatdeliverslowow
ratesoflessthanone(1)literperminutetoapediatric
patientthroughapediatricnasalcannula.
Inputoxygengasataninputpressureof5.0+/-10%PSI
andataminimumowrateof2litersperminutebya
compatibleInvacare5literoutputoxygenconcentratoris
deliveredtothedeviceinputthroughanexternalextension
tubingaccessory.Theinputgasisroutedtoaninternal
bleedoriceformaintainingaminimumowoutputload
totheoxygenconcentratorformaintainingadequate
oxygenconcentrationvaluesofthedeliveredgasbythe
1150712-D5

Invacare®PreciseRx™PediatricFlowmeter
oxygenconcentrator.Theinputgasisthensuppliedto
theinputofavariableowratedeviceandowmeter
forowrateadjustmentandsubsequentdeliverytothe
outputttingfordeliverytoapediatricpatientthroughan
externallyconnectedadministrationaccessory,apediatric
nasalcannula.
Oxygengasoutputcanbedeliveredtothepatientin
adjustableowratesinthecontinuousowmodeoverthe
rangeof1/16to3/4litersperminute.
Anexternallymountedwaterhumidiercanbeusedin-line
withtheoutputttingtoprovidehumidicationofthe
oxygengasdeliveredtothepediatricpatient.
61150712-D

Safety
2Safety
2.1GeneralGuidelines
Inordertoensurethesafeinstallation,assemblyand
operationofthedevicetheseinstructionsMUSTbefollowed.
DANGER!
RiskofDeath,InjuryorDamagefromFire
Textiles,oilorpetroleumsubstances,grease,
greasysubstancesandothercombustiblesare
easilyignitedandburnwithgreatintensityin
oxygenenrichedairandwhenincontactwith
oxygenunderpressure.Smokingduringoxygen
therapyisdangerousandislikelytoresultin
burnsordeath.Toavoidre,death,injuryor
damage:
–DONOTSMOKEwhileusingthisdevice.DO
NOTusenearOPENFLAMEorIGNITION
SOURCES.
–NOSMOKINGsignsshouldbeprominently
displayed.
–Keepallopenames,matches,lighted
cigarettes,electroniccigarettes,orother
sourcesofignitionatleast3m(10ft)away
fromanyconcentratororanyoxygencarrying
accessoriessuchascannulasortanks.
DANGER!
RiskofDeath,InjuryorDamagefromFire
Textiles,oilorpetroleumsubstances,grease,
greasysubstancesandothercombustiblesare
easilyignitedandburnwithgreatintensityin
oxygenenrichedairandwhenincontactwith
oxygenunderpressure.Toavoidre,death,
injuryordamage:
–Avoidcreationofanysparknearoxygen
equipment.Thisincludessparksfromstatic
electricitycreatedbyanytypeoffriction.
–Useonlyoxygencompatiblewater-basedlotions
orsalvesbeforeandduringoxygentherapy.To
verify,refertothelotion/salvecontainerfor
oxygencompatiblewater-basedstatement.If
necessary,contactthemanufacturer .DONOT
useanylubricantsonconcentratororaccessory
ttingsunlessrecommendedbyInvacare.
–Keeptheoxygentubing,cord,ACadapter,
andconcentratoroutfromundersuchitems
asblankets,bedcoverings,chaircushions,
clothing,andawayfromheatedorhotsurfaces
includingspaceheaters,stoves,andsimilar
electricalappliances.
–Makesureconcentratorisoffwhennotinuse.
1150712-D7

Invacare®PreciseRx™PediatricFlowmeter
DANGER!
RiskofDeath,InjuryorDamage
Improperuseoftheproductmaycausedeath,
injuryordamage.Thissectioncontainsimportant
informationforthesafeoperationanduseofthis
product.
–DONOTusethisproductoranyavailable
optionalequipmentwithoutrstcompletely
readingandunderstandingtheseinstructions
andanyadditionalinstructionalmaterialsuch
asusermanuals,servicemanualsorinstruction
sheetssuppliedwiththisproductoroptional
equipment.
–Ifyouareunabletounderstandthewarnings,
cautionsorinstructions,contactahealthcare
professional,dealerortechnicalpersonnel
beforeattemptingtousethisequipment.
–CheckALLexternalcomponentsandcartonfor
damage.Incaseofdamage,oriftheproduct
isnotworkingcorrectly,contactatechnician
orInvacareforrepair .
–Thisproductisintendedtobesetupby
adultsorunderadultsupervisiononlyafter
readingandunderstandingtheinstructionsand
warningsofthisusermanual.
–THEINFORMATIONINTHISDOCUMENTIS
SUBJECTTOCHANGEWITHOUTNOTICE.
DANGER!
RiskofInjuryorDeath
Toavoidchokingoringestionofchemicalsfrom
airwaycontamination:
–DONOTusetheconcentratorinthepresence
ofpollutants,smoke,fumes,ammable
anesthetics,cleaningagents,orchemical
vapors.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamagefrommisuse:
–NEVERleaveconcentratorunattendedwhen
pluggedin.
–Makesureconcentratorisoffwhennotinuse.
WARNING!
RiskofInjuryorDamage
–Invacareproductsarespecicallydesigned
andmanufacturedforuseinconjunctionwith
Invacareaccessories.Accessoriesdesignedby
othermanufacturershavenotbeentestedby
Invacareandarenotrecommendedforuse
withInvacareproducts.
–Nomodicationofthisequipmentisallowed.
81150712-D

Safety
WARNING!
RiskofInjury
Achangeinaltitudemayaffecttotaloxygen
availableforuse.Topreventoxygendeprivation:
–Consultaphysicianbeforetravelingtohigher
orloweraltitudestodetermineifthepatient’s
owsettingsshouldbechanged.
WARNING!
RiskofInjuryorDeath
Topreventinjuryordeathfromproductmisuse:
–Closelysupervisewhenthisdeviceisused
byornearchildrenorphysically-challenged
individuals.
–Monitorpatientsusingthisdevicewhoare
unabletohearorseealarmsorcommunicate
discomfort.
–Keepoutofreachofchildrenandawayfrom
pets.
DANGER!
RiskofInjuryorDeath
WhileInvacarestrivestoproducethebest
oxygendevicesinthemarkettoday,theoxygen
concentratorcanfailtoproduceoxygendueto
powerfailureordevicemalfunction.
–Contactyourproviderforabackupsourceof
oxygenforapediatricpatient.
–Donotconnecttheinputofthedevicetoany
otheroxygendeliverydeviceotherthanan
Invacare5literoutputoxygenconcentrator,
otherwiseseriousinjurycanoccur .
–ThePediatricFlowmeterisdesignedforan
inputpressureof34.5kPa(5psi)only.The
owmeterisapplicableonlywithInvacare
concentratorswith34.5kpa(5psi)output
pressure.
WARNING!
RiskofInjuryorDamage
Topreventinjuryordamageduringuse:
–Foroptimumperformance,Invacare
recommendsthattheconcentratorbeonand
runningforaminimumof30minutes.Shorter
periodsofoperationmayreducemaximum
productlife.
–Forproperoxygenoutput,theconcentrator
shouldbeusedinanuprightposition.
–ThePediatricFlowmetercannotbeusedin
conjunctionwithPAP ,Bi-Level,mechanical
ventilatororothersuchdevices.
1150712-D9

Invacare®PreciseRx™PediatricFlowmeter
WARNING!
RiskofInjuryorDamage
ThePediatricFlowmeterisspecicallydesigned
toeliminateroutinepreventivemaintenance.To
preventinjuryordamage:
–Onlyprofessionalsofthehealthcareeldor
personsfullyconversantwiththisprocesssuch
asfactorytrainedpersonnelshouldperform
service,exceptfortasksdescribedinthis
manual.
–UsersshouldcontactyourdealerorInvacare
forservice.
–DONOTdisassemble.Referservicingto
qualiedservicepersonnel.Therearenouser
serviceableparts.
CAUTION!
RiskofDamage
Topreventdamagefromliquidingress:
–Ifthedeviceisnotworkingproperly,ifit
hasbeendroppedordamaged,ordropped
intowater,callequipmentprovider/qualied
technicianforexaminationandrepair.
–NEVERdroporinsertanyobjectorliquidinto
anyopening.
–Useofthisdevicewithahumidierlocatedon
theinletgasstreammayimpairperformance
ordamagethePediatricFlowmeter.Useof
ahumidierislimitedtouseonlyonthe
outputgasbeingdeliveredbythePediatric
Flowmetertothepatient.RefertoSetupWith
aHumidierBottle.
101150712-D

Setup
3Setup
3.1Handling
UnpackingandInspection
1.Checkforanyobviousdamagetothecartonorits
contents.Ifdamageisevident,notifyyourcarrier/dealer
forfurtherinstruction.
2.Removealltheloosepackingfromthecarton.
3.Carefullyremoveallcomponentsfromthecarton.
Packingmaterialsandcartonshouldbekeptfor
futureuseduringstorageortransportation.
4.Examineexterioroftheowmeterfornicks,dents,
scratchesorotherdamages.Inspectallcomponents.
Storage
1.Storetherepackagedowmeterinadryarea.
2.DONOTplaceotherobjectsontopoftherepackaged
device.
Cleaning
Theunitexteriorcanbecleanedwithwarmsoapywater .
Wipewithasoft,dampclothanddrythoroughly.
3.2TypicalSetup
WARNING!
–ONLYuseapediatricnasalcannulawiththis
device.
–Placethepediatricnasalcannulaonpatient
onlyafteralltubingconnectionshavebeen
made.Possiblewaterfeedbackthroughthe
tubingcouldoccurinthissequenceisnot
followed.
–WhenadjustingthePediatricFlowmeter,the
owmeterontheoxygenconcentratorMUST
besetat2.0L/min.Failuretocomplywith
thisprocedurewillcauseincorrectowrates
tothepatient.
–Invacarerecommendsthatcrushresistant
oxygentubing(notsupplied)beusedwiththis
product.
WARNING!
–Ifuseofahumidierbottleisnotprescribed,
theoxygentubingisnottoexceed7.6m(25ft)
intotallengthfromthePediatricFlowmeterto
thepatient,andthetotallengthofALLtubing
CANNOTexceed15.2m(50ft).
–Ifuseofahumidierbottleisprescribed,the
oxygentubingisnottoexceed7.6m(25ft)in
totallengthfromthehumidierbottletothe
patient,andthetotallengthofALLtubingfor
thePediatricFlowmeterCANNOTexceed11.8
m(39ft).
1150712-D11

Invacare®PreciseRx™PediatricFlowmeter
1.TurntheInvacare5literoutputconcentratoron.An
indicatorlightonthecontrolpanelwillilluminate.Refer
totheconcentratorusermanualforsetupanduse.
2.Settheoxygenconcentratorto2.0L/min.
3.PlacethePediatricFlowmeterstandontabletop.
4.TurnthePediatricFlowmeterknobcounterclockwise
tothefullyopenposition.
5.Allowconcentratortorunaminimumof30minutesto
ensureproperconcentrationlevel.Checkandreadjust
theoxygenconcentratorto2.0L/min.
Accessories–Oxygentubing,tubingconnector,pediatric
nasalcannula,andhumidierbottlewithadapterarenot
suppliedwiththePediatricFlowmeter .
•Optionalaccessories:StandardHumidier—Invacare
PartNumber1155719.
121150712-D

Setup
3.3SetupWithoutaHumidierBottle
APediatricFlowmeter
BInputFittingonPediatricFlowmeter
COutputFittingofConcentrator
DConcentrator
E2.1m(7ft)OxygenTubing
FOutputFittingofFlowmeter
1.Connecta2.1m(7ft)oxygentubingEfromtheoutput
ttingCoftheconcentratorDtotheinputttingB
ofthePediatricFlowmeterA.
2.Connecta7.6m(25ft)maximumlengthoxygentubing
(notshown)totheoutputttingFofthePediatric
FlowmeterA.
3.Attachtheoppositeendoftheoxygentubing(not
shown)toapediatricnasalcannulausinganappropriate
oxygentubingconnectorasapplicable(notshown).
1150712-D13

Invacare®PreciseRx™PediatricFlowmeter
3.4SetupWithaHumidierBottle
APediatricFlowmeter
BInputFittingofPediatricFlowmeter
COutputFittingofConcentrator
DConcentrator
E2.1m(7ft)OxygenTubingfromConcentratorto
Flowmeter
FOutputFittingofFlowmeter
G2.1m(7ft)OxygenTubingfromFlowmeterto
Concentrator
HHumidierBottle
IInletofHumidierBottle
1.Connecta2.1m(7ft)maximumoxygentubingEfrom
theoutputttingCoftheconcentratorDtotheinput
ttingBofthePediatricFlowmeterA.
2.Followthedirectionssuppliedbythehumidier
bottleHmanufacturerforinstructionsonllingand
connectingtooxygentubing.
3.Afterllingthehumidierbottlewithwater,place
itinthehumidiercompartmentontheInvacare
concentratorD(seeconcentratorusermanualfor
mountingthebottle).
4.Connect2.1m(7ft)maximumoxygentubingGfrom
thePediatricFlowmeterAoutputttingFtothe
inletofthehumidierbottleI(usinganappropriate
adapterifapplicable).
5.Connecta7.6m(25ft)maximumoxygentubingtothe
outletofthehumidierbottle(notshown).
6.Attachtheoppositeendoftheoxygentubingtoa
pediatricnasalcannulausinganappropriateoxygen
tubingconnector(notshown).
CAUTION!
–DONOTcoilcrushresistantoxygentubingon
COLDoororcondensationwillforminside
thetubing.
141150712-D

Setup
3.5SettingtheFlowrateonthePediatric
Flowmeter
WARNING!
–DONOTselectadifferentsettingunlessthe
patient’sphysicianhasprescribedachangein
theowrateofthePediatricFlowmeter.
CAUTION!
–DONOTallowwaterorothersubstancesto
enterowmeteropenings.DONOTsubmerge
theowstand,owmeterortubinginwater.
1.SetthePediatricFlowmeterasprescribedbythe
patient’sphysician.
Theowrateonthestandardconcentrator
owmeterwilldropbelowthe2.0L/minsetting
aftertheowmeterisinstalledandoperating.
ThePediatricFlowmetersettingshouldbe
reassessedperiodically.
2.Whenadjustingtheow,centertheballAofthe
PediatricFlowmeterBwiththelineoftheprescribed
owrate.Whenviewingfromtheproperangle,the
graduationlinesonthefrontandthebackofthe
owmeterwillbeinalignmentwiththecenterofthe
ball.
3.Checkforoxygendeliverybyplacingthenasalprongs
ofthepediatricnasalcannulaunderthesurfaceofa
half-fullglassofwateronlywhentheoxygenisowing
andlookforbubblesindicatingproperoperation.Wipe
anyexcesswateroffthenasalprongswhennished
beforeplacingonthepatient.
4.Placepediatricnasalcannulaonthepatient.
Theproperplacementandpositioningofthe
prongsofthepediatricnasalcannulainthenose
iscriticaltotheamountofoxygendeliveredto
therespiratorysystemofthepatient.
1150712-D15

Invacare®PreciseRx™PediatricFlowmeter
4AfterUse
4.1RecyclingInformation
Thisproducthasbeensuppliedfromanenvironmentally
awaremanufacturer.
Followlocalgoverningordinancesandrecyclingplans
regardingdisposalofthedeviceoraccessoriesnormally
usedinoperation.Thedevicedoesnotgeneratewasteor
residueinoperation.
AnyaccessoriesnotpartofthedeviceMUSTbehandledin
accordancewiththeindividualproductmarkingfordisposal.
161150712-D

Technicaldata
5Technicaldata
5.1Specications
INPUTPRESSURERATING:34.5±3.45kPa(5±0.5psi)
OXYGENINPUT:2L/min,85%to95.6%oxygen
MAXIMUMOUTPUTPRESSURE:27.6kPa(4.0psi)
OXYGENOUTPUTFLOW:0–750cc/min(0–3/4L/min)
FLOWADJUSTABLEININCREMENTS:50cc/min(1/16L/min)
FLOWACCURACY:±10%offullscale
WIDTH:11.94cm(4.7in)
HEIGHT:14.48cm(5.7in)
DEPTH:14.48cm(5.7in)
WEIGHT:0.8kg(1.86lb)
SHIPPINGWEIGHT:1.1kg(2.40lb)
OPERATINGTEMPERATURERANGE:10°to35°C(50°to95°F)
STORAGETEMPERATURERANGE:–29°to70°C(–20°to158°F)
Measurementuncertaintyisincludedinthedevicespecication.Allconditionsatambienttemperatureandpressure,dry.
1150712-D17

Invacare®PreciseRx™PediatricFlowmeter
6Warranty
6.1LimitedWarranty
Termsandconditionsofthewarrantyarepartofthegeneral
termsandconditionsparticulartotheindividualcountriesin
whichthisproductissold.
ContactinformationforyourlocalInvacareofceislocated
insidethebackcoverofthismanual.
181150712-D

Belgium&Luxemburg:Invacarenv,Autobaan22,B-8210Loppem•Tel:(32)(0)50831010•Fax:(32)(0)508310
11•belgium@invacare.com•www.invacare.be
Danmark:InvacareA/S,Sdr.Ringvej37,DK-2605Brøndby•Tel:(45)(0)36900000•Fax:(45)(0)36900001
•denmark@invacare.com•www.invacare.dk
Deutschland:InvacareGmbH,Alemannenstraße10,D-88316Isny•Tel:(49)(0)75627000•Fax:(49)(0)75627
0066•kontakt@invacare.com•www.invacare.de
EasternEurope,Middle
East&CIS:
InvacareEUExport•Kleiststraße49•D-32457PortaWestfalica•Germany•Tel:(49)5731754540•
Fax:(49)5731754541•webinfo-eu-export@invacare.com•www.invacare-eu-export.com
España:InvacareSA,c/Arenys/n,PolígonIndustrialdeCelrà,E-17460Celrà(Girona)•Tel:(34)(0)9724932
00•Fax:(34)(0)972493220•contactsp@invacare.com•www.invacare.es
France:InvacarePoirierSAS,RoutedeStRoch,F-37230Fondettes•Tel:(33)(0)247626466•Fax:(33)(0)2
47421224•contactfr@invacare.com•www.invacare.fr
Ireland:InvacareIrelandLtd,Unit5SeatownBusinessCampus•SeatownRoad,Swords,CountyDublin–
Ireland•Tel:(353)18107084•Fax:(353)18107085•ireland@invacare.com•www.invacare.ie
Italia:InvacareMeccSans.r.l.,ViadeiPini62,I-36016Thiene(VI)•Tel:(39)0445380059•Fax:(39)0445
380034•italia@invacare.com•www.invacare.it
Nederland:InvacareAE,Galvanistraat14–3,NL–6716BZEde•Tel:(31)(0)318695757•Fax:(31)(0)318695
758•nederland@invacare.com•csede@invacare.com•www.invacare.nl
Norge:InvacareAS,Grensesvingen9,Postboks6230,Etterstad,N-0603Oslo•Tel:(47)(0)22579500•Fax:
(47)(0)22579501•norway@invacare.com•island@invacare.com•www.invacare.no
Österreich:InvacareAustriaGmbH,HerzogOdilostrasse101,A-5310Mondsee•Tel:(43)623255350•Fax:
(43)623255354•info@invacare-austria.com•www.invacare.at
Portugal:InvacareLda•RuaEstradaVelha,949,P-4465-784LeçadoBalio•Tel:(351)(0)225105946/47•Fax:
(351)(0)225105739•portugal@invacare.com•www.invacare.pt
Sverige:InvacareAB•Fagerstagatan9•S-16353Spånga•Tel:(46)(0)87617090•Fax:(46)(0)876181
08•sweden@invacare.com•www.invacare.se
Suomi:CampMobility•Patamäenkatu5,33900Tampere•Tel:09-35076310•info@campmobility.•
www.campmobility.
Schweiz/Suisse/Svizzera:InvacareAG•Benkenstrasse260•CH-4108Witterswil•Tel.:(41)(0)614877080•Fax.:(41)(0)61
4877081•switzerland@invacare.com•www.invacare.ch
UnitedKingdom:InvacareLimited,PencoedTechnologyPark,Pencoed,BridgendCF355HZ•Tel:(44)(0)1656776222•
Fax:(44)(0)1656776220•UK@invacare.com•www.invacare.co.uk

InvacareCorporation
USA
OneInvacareWay
Elyria,Ohio44035
UnitedStates
Tel:440–329–6000
Tel:800–333–6900
TechnicalServices
Tel:440–329–6593
Tel:800–832–4707
www.invacare.com
EURepresentative
InvacareDeutschlandGmbH
Kleiststraße49
D-32457PortaWestfalica
Germany
Tel:(49)(0)57317540
Fax:(49)(0)573175452191
Manufacturer
InvacareCorporation
2101E.LakeMaryBlvd.
Sanford,FL32773
UnitedStates
Tel:407–321–5630
1150712-D2017-05-05
*1150712D*
MakingLife’sExperiencesPossible®
Table of contents