Technical parameters
Inputs 4 x IF inputs from Quattro LNB
Outputs 4 x Loopthrough satellite IF outputs
1 x Unicable output to connect up to 4 receiver tuners
Frequency range Satellite: 950-2150MHz
Loopthrough loss Satellite: max -3dB
Gain Satellite: 10dB (min)
Isolation Satellite-Satellite outputs: min 30dB
Control protocol DiSEqC™ commands extension according to CENELEC
prEN50494
Power consumption 20VDC, 225mA
Dimensions (W x H x D mm) W=88 H=120 D=35 mm
Temperature range -20C - +60C
AC/DC adaptor Input voltage: 100-240VAC, 50/60Hz
Output voltage: 19VDC
Output current: 940mA
Short circuit protection: Yes
Power Inserter Input voltage: 20VDC
Output power: 15VDC, 600mA
Troubleshooting
Make sure the satellite antenna and LNB are properly fixed, connected and adjusted and that the
satellite receivers are installed, connected and switched on according to available instructions.
Ensure there is no short circuit on the product inputs. This will prevent power to the LNB. If this is the
case, disconnect the product from the main power, and then find and remove the short circuit on the
product inputs. Then re-connect the multiswitch to the main power.
Frequent defects are in connector joints i.e. if the central conductor is too short and fails to make
contact in the connector. Also the shielding braid should make proper contact with the connector
coat. Sometimes a reset to the multiswitch microprocessor is sufficient to remove a fault: simply
disconnect the multiswitch from main power for 30 seconds and then reconnect again.
If you are unable to remove the fault yourself, please contact your distributor.
Disposal
Following relevant EU directives, this device shall not be disposed of together with municipal waste.
Use local waste collection and recycling systems to dispose wore out products.
*DiSEqC™ is a registered trademark of Eutelsat
*For purpose of brevity, some product descriptions in this sheet remain at platform level and may not be
referred to as detailed datasheets of the products. Inverto Digital Labs reserves the right to amend, omit or
add products, product-lines, and/ or features without notice.
Installation manual
Unicable™Multiswitch
IDLP-USW1O2-CUO1O-4PP
4
V161013
V/LV/HH/L H/H
Satellite - Input
H/H
H/L
V/H
V/L
Satellite - loop-through output
TM
Unicable cascadable switch 4 User Bands
IDLP-USW1O2-CUO1O-4PP
User Bands :
0 : 1210MHz
1 : 1420MHz
2 : 1680MHz
3 : 2040MHz
Satellite inputs: IF 950-2150MHz
Satellite Loop-Through loss: -3dB
Unicable Out
Connect the cables from the Quattro LNB to the input connectors marked with LNB V/L, V/H, H/L and
H/H inputs (pay attention to identification of the Quattro LNB connectors).
V/LV/HH/L
H/H
Satellite - Input
H/H
H/L
V/H
V/L
Satellite - loop-through output
TM
Unicable cascadable switch 4 User Bands, 1 Legacy port
IDLP-USW112-CUO1O-4PP
User Bands :
0 : 1210MHz
1 : 1420MHz
2 : 1680MHz
3 : 2040MHz
Satellite inputs: IF 950-2150MHz
Satellite Loop-Through loss: -3dB
Unicable Out Legacy Out
The Unicable output allows to connect up to 4 receiver tuners – each needs to be allocated one of the
4 user bands supported by the multiswitch.
Each receiver tuner is assigned with 1 out of 4 communication channel frequencies (user band). The
frequencies are listed on the product sticker:
V/LV/HH/L H/H
Satellite - Input
H/H
H/L
V/H
V/L
Satellite - loop-through output
TM
Unicable cascadable switch 4 User Bands
IDLP-USW1O2-CUO1O-4PP
User Bands :
0 : 1210MHz
1 : 1420MHz
2 : 1680MHz
3 : 2040MHz
Satellite inputs: IF 950-2150MHz
Satellite Loop-Through loss: -3dB
Unicable Out
V/L V/H H/L
H/H
Satellite - Input
H/H
H/L
V/H
V/L
Satellite - loop-through output
TM
Unicable cascadable switch 4 User Bands, 1 Legacy port
IDLP-USW112-CUO1O-4PP
User Bands :
0 : 1210MHz
1 : 1420MHz
2 : 1680MHz
3 : 2040MHz
Satellite inputs: IF 950-2150MHz
Satellite Loop-Through loss: -3dB
Unicable OutLegacy Out
For optimized performance, please follow the recommendations below:
1. use the highest frequency for a wall socket located the nearest to the multiswitch and use the
lowest frequency for wall socket located farest to the multiswitch.
2. If you install less than 4 receiver tuners, use the lowest frequencies first. We also recommend
to keep record of the user bands allocated to the different connections as these user bands will
then have to be set in the receiver. The satellite receivers connected to the multiswitch have to
be Unicable-compatible (usually marked with Unicable™ logo).
Note: Loopthrough outputs that are not used should be terminated with 75ohm DC-blocked
terminations.
Safety
Never open a powered product. This may result in electrical hazard.
Never work on the product, TV set or other powered devices during or before a storm. A lightning
strike into the antenna may cause dangerous overvoltage over the product’s metallic/conductive
parts.
Make sure the local electricity network corresponds to the operating voltage of the AC/DC adaptor.
If the products gets into contact with liquid it must be disconnected from the main power.
It is recommended to disconnect the product from the main power if it is not used for long periods of
time.
When disconnecting the product don’t pull the cable but the plug to prevent damage of the cable
(wobbly plugs and outlets result in fire risk).
The product shall be serviced by qualified experts only.
Thank you for purchasing Inverto’s advanced Unicable multiswitch and we are certain it will meet your
expectations. Before installing and operating the product, please read the following instructions and
recommendations. We suggest that you keep this manual for future use.
Warranty
This Unicable multiswitch is designed for the distribution of satellite and terrestrial television and radio
signals in home installations. The warranty does not apply for products used for other purposes than
those specified herein. The user/installer shall be responsible for any damage incurred as a result of
not using the product according to the instructions in this manual.
Installation location
The product shall be installed on a wall or other hard inflammable surface.
The product shall be in no case held only with the connected cables.
Place the product in a dry environment where it is not exposed to rain or running water.
Do not install the product close to heat sources or in places exposed to direct sunlight.
Product installation
The following diagram may assist you when drilling the holes:
122
114.50
V/L V/H H/L H/H
Satellite - Input
H/H
H/L
V/H
V/L
Satellite - loop-through output
TM
Unicable cascadable switch 4 User Bands
IDLP-USW1O2-CUO1O-4PP
User Bands:
0 : 1210MHz
1 : 1420MHz
2 : 1680MHz
3 : 2040MHz
Satellite inputs: IF 950-2150MHz
Satellite Loop-Through loss: -3dB
Unicable Out
To connect the product inputs and outputs use high-quality
coaxial cables designed for satellite reception and
F-connectors. Use a high-shielding coaxial cables with
minimum 90dB.
If you use wall sockets to loopthrough the 4 user bands, make
sure the wall sockets were designed for satellite reception
compatible with Unicable technology and allows bidirectional
signal propagation.
The switch may be powered by the connected Unicable
STBs directly or through the supplied Power Inserter and
AC adaptor. For long cable installations, it is recommended t o
use the supplied Power Inserter and the AC/DC adaptor in order to ensure proper and stable input volt-
age level. The power inserter shall be connected over the Unicable port.
The following diagram describes the installation configurations supported by the product:
Quattro
LNB 1
Terminated
Outputs
x4 User bands
UB 0 UB 1
UB 2 UB 3
Power
inserter
x4 User bands
UB 0 UB 1
UB 2 UB 3
V/L V/H H/L H/H
Satellite- Input
H/H
H/L
V/H
V/L
Satellite- loop-through output
TM
Unicablecascadable switch 4 User Bands
IDLP-USW1O2-CUO1O-4PP
UserBands:
0: 1210MHz
1: 1420MHz
2: 1680MHz
3: 2040MHz
Satelliteinputs: IF 950-2150MHz
SatelliteLoop-Through loss: -3dB
UnicableOut
V/L V/H H/L H/H
Satellite- Input
H/H
H/L
V/H
V/L
Satellite- loop-through output
TM
Unicablecascadable switch 4 User Bands
IDLP-USW1O2-CUO1O-4PP
UserBands:
0: 1210MHz
1: 1420MHz
2: 1680MHz
3: 2040MHz
Satelliteinputs: IF 950-2150MHz
SatelliteLoop-Through loss: -3dB
UnicableOut
AC/DC Input
2 3

This manual suits for next models

1

Other Inverto Switch manuals

Inverto Unicable II 5151 User manual

Inverto

Inverto Unicable II 5151 User manual

Inverto Unicable II User manual

Inverto

Inverto Unicable II User manual

Inverto Unicable IDLU-UST112-CUO1O-8PP User manual

Inverto

Inverto Unicable IDLU-UST112-CUO1O-8PP User manual

Inverto 5413 User manual

Inverto

Inverto 5413 User manual

Inverto Unicable II User manual

Inverto

Inverto Unicable II User manual

Inverto Unicable II User manual

Inverto

Inverto Unicable II User manual

Inverto IP-LNB User manual

Inverto

Inverto IP-LNB User manual

Inverto Unicable II 6207 User manual

Inverto

Inverto Unicable II 6207 User manual

Inverto Unicable II Multiswitch User manual

Inverto

Inverto Unicable II Multiswitch User manual

Inverto Unicable II User manual

Inverto

Inverto Unicable II User manual

Inverto Unicable II ISKY-UST111-CUO4O-16P User manual

Inverto

Inverto Unicable II ISKY-UST111-CUO4O-16P User manual

Popular Switch manuals by other brands

Compex readylink CGX3224 user manual

Compex

Compex readylink CGX3224 user manual

AMX NXA-ENET8-2POE instruction manual

AMX

AMX NXA-ENET8-2POE instruction manual

Pickering 40-855A user manual

Pickering

Pickering 40-855A user manual

ADDER CATx user guide

ADDER

ADDER CATx user guide

B&B Electronics ETHUB16 datasheet

B&B Electronics

B&B Electronics ETHUB16 datasheet

Gembird CAS-241 user manual

Gembird

Gembird CAS-241 user manual

Digitus DS-12891 user manual

Digitus

Digitus DS-12891 user manual

Soyntec Nexoos 395 instructions

Soyntec

Soyntec Nexoos 395 instructions

Planet KVM-800 user manual

Planet

Planet KVM-800 user manual

Tripp Lite B020-U08-19-K quick start guide

Tripp Lite

Tripp Lite B020-U08-19-K quick start guide

3Com Baseline 2824 user guide

3Com

3Com Baseline 2824 user guide

TP-Link JetStream TL-SL3452 reference guide

TP-Link

TP-Link JetStream TL-SL3452 reference guide

SignaMax 065-7890FSFPDP quick start guide

SignaMax

SignaMax 065-7890FSFPDP quick start guide

Key Digital KD-HDMI2X1 operating instructions

Key Digital

Key Digital KD-HDMI2X1 operating instructions

EtherWAN EX78900E Series installation guide

EtherWAN

EtherWAN EX78900E Series installation guide

Perle IDS-306 quick start guide

Perle

Perle IDS-306 quick start guide

Kramer VM-218DTxr quick start guide

Kramer

Kramer VM-218DTxr quick start guide

IOGear GCS1792 installation guide

IOGear

IOGear GCS1792 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.