INVIXIUM XAD-FDD-524-02G
1
Feature Description Document
Configuring Door Strike Power Supply
INVIXIUM XAD-FDD-524-02G
2
Purpose
This document outlines the process of configuring the Door Strike Power Supply setting
from IXM WEB.
Applies to
TITAN
TFACE
TOUCH 2
SENSE 2
All Devices
All Devices
All Devices
All Devices
Description
TITAN, TFACE, TOUCH 2 & SENSE 2 are equipped with the ability to redirect all their
extra power and use it to supply to the Electric Door Strike, removing the need to have 2
separate power sources - 1 for the device and 1 for the door strike. Activating the Door
Strike Power Supply feature will trigger a specified power supply to the connected
strike.
There are two ways to configure the Door Strike Power Supply settings:
1. In IXM WEB, under the Device tab →click the Access Control navigation
tab →Door Strike Power Supply app.
2. From TITAN, TFACE, and TOUCH 2’s LCD menu system →Door Access
app.
To enable this feature, the Door Access Control wiring is different compared to using 2
separate power supplies. Please refer to the respective wiring diagram in the INGUIDE
or the installation guide before configuring this setting in IXM WEB.
INVIXIUM XAD-FDD-524-02G
3
Configuring Door Strike Power Supply from IXM WEB
1. From Home >> Click the Device tab on the top >> Select the required Device >>
Navigate to the Access Control tab for the device >> Click on Door Strike Power
Supply.
2. Toggle the “Door Strike Power Supply” switch on the right to enable the Door
Strike Power Supply feature.
INVIXIUM XAD-FDD-524-02G
4
3. Change the Mode value to 12V or 24V depending on the installed door strike
specifications. (TOUCH 2 and SENSE 2 only support a 12V door strike.)
4. Click Apply to save the settings to the IXM device.
5. To reset the Door Strike Power Supply settings back to default, click Reset. A “Door
strike power supply settings restored” message will be displayed. Click OK.
INVIXIUM XAD-FDD-524-02G
5
Configuring Door Strike Power Supply on the LCD Menu
1. Swipe to the Door Access app from the Menu screen. Tap on the Door Access
icon. The device will prompt for device security authentication before opening the
app (The default PIN is 0000).
INVIXIUM XAD-FDD-524-02G
6
2. Tap on Door Strike Power Supply.
INVIXIUM XAD-FDD-524-02G
7
3. Toggle Status to ON to enable settings.
4. Select supply mode as 12V or 24V (TOUCH 2 and SENSE 2 only support a 12V
door strike) and tap the Save icon on the top right to store the settings.
INVIXIUM XAD-FDD-524-02G
8
Support
For more information relating to this Feature Description document, please contact us at
[email protected]
Disclaimers and Restrictions
This document and the information described throughout are provided in their present
condition and are delivered without written, expressed, or implied commitments by
Invixium Inc. and are subject to change without notice. The information and technical
data herein are strictly prohibited for the intention of reverse engineering and shall not
be disclosed to parties for procurement or manufacturing.
This document may contain unintentional typos or inaccuracies.
TRADEMARKS
The trademarks specified throughout the document are registered trademarks of
Invixium Access Inc. All third-party trademarks referenced herein are recognized to be
trademarks of their respective holders or manufacturers.
Copyright © 2022, INVIXIUM. All rights reserved.

Other manuals for TITAN

3

This manual suits for next models

3

Popular Power Supply manuals by other brands

Snarkoon WPM Gold ZERO Series manual

Snarkoon

Snarkoon WPM Gold ZERO Series manual

Siemens MICROMASTER 430 FX Maintenance Instruction

Siemens

Siemens MICROMASTER 430 FX Maintenance Instruction

Analytic Systems PWS1510MS Installation & operation manual

Analytic Systems

Analytic Systems PWS1510MS Installation & operation manual

Omron S8VK-G Series instruction manual

Omron

Omron S8VK-G Series instruction manual

Proxxon NG 5/E manual

Proxxon

Proxxon NG 5/E manual

Vanderbilt SPCP432 instructions

Vanderbilt

Vanderbilt SPCP432 instructions

Inaxsys SW1210-16CB Product installation document

Inaxsys

Inaxsys SW1210-16CB Product installation document

Avansa 500 W operating instructions

Avansa

Avansa 500 W operating instructions

Sony XDBK-101 installation guide

Sony

Sony XDBK-101 installation guide

OCZ PRO X STREAM user guide

OCZ

OCZ PRO X STREAM user guide

AP&T AP-AY1506 quick start guide

AP&T

AP&T AP-AY1506 quick start guide

Valcom VP-12124 user guide

Valcom

Valcom VP-12124 user guide

Sargent PSU 2005 manual

Sargent

Sargent PSU 2005 manual

Altimium PWSU12 user manual

Altimium

Altimium PWSU12 user manual

Oakley PCB Issue 2 user manual

Oakley

Oakley PCB Issue 2 user manual

Bluetti EB70 user manual

Bluetti

Bluetti EB70 user manual

Keysight E36300 Series user guide

Keysight

Keysight E36300 Series user guide

Pyle Pro PDBC60 owner's manual

Pyle Pro

Pyle Pro PDBC60 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.