Invixium MERGE 2 User manual

IXM INGUIDE
Quick Start Guide
MERGE 2 MERGE CR

Invixium Customer Portal
Stay up to date with:
▪Latest Updates
▪Best Practices
▪Datasheets
▪Installation Guides
▪Feature Description Documents
▪Videos
▪FAQs
▪Tutorials
▪And more...
Visit https://www.invixium.com/support/

In the Box
IXM INSTALL KIT
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
DOLPHIN
Metal Mounting
Plate
Earth Ground Wire
Metal Mounting
Plate Screw
(qty 2)
Wall Mounting Screws
(qty 4)
Wired Back Cover
Hex Key
Dolphin Crimps
(qty 10)
Snubber Diode

Getting Started
1Remove the Mounting Plate, Wired Back
Cover and Screws from the IXM INSTALL KIT.
2Install the Mounting Plate at the desired
location (INVIXIUM recommends 120-130 cms
from the floor to the bottom of the device).
3Make the necessary connections to the Wired
Back Cover (refer to Get Wired Pages).
4Unscrew and remove the Temporary Back
Cover from the IXM device and connect the
Wired Back Cover using the same screws.
5Hang your IXM device on the Mounting Plate
and secure it on the bottom with the screw
provided.

Get Wired Glossary
ACP OTGAccess Control Panel On-The-Go
SGND Signal Ground
DAC Door Access Control
TAMPER Tamper
EGND Earth Ground
DGND Digital Ground SPO Specific Purpose Output
WDATA Wiegand DataNO Normally Open
GND Ground VIN+ Power (12VDC)
COM Common RLY Relay
NC Normally Closed VIN- Power Ground
Connector
1 3 5 7 9 11 13 15 17 19
2 4 6 8 10 12 14 16 18 20

Get Wired Connector
Purple/Yellow
Blue/White
White/Red RLY_NC
White/Purple DAC_IN1DAC_IN2
DAC_IN3
Orange/Yellow SPO_1
Grey/Red RLY_NO 17
11
13
Purple TAMPER 15
Wire Color
Red
Black
Green/Yellow
Wire Color
Black/Red
Blue
Blue/Black
Green/White
White/Black
Green
Black/Green
Label
VIN+
VIN-
EGND
Label
SGND
RS485+(B)
RS485- (A)
WDATA_IN0
WDATA_IN1
WDATA_OUT0
DGND
Wire WirePin(s)
1
3
5
Pin(s)
2
4
19
8
10
12
14
16
18
20
7
White WDATA_OUT1 9
Orange DAC_OUT 6
Grey RLY_COM

Earth Ground Connections
Earth Ground
For protection against Electrostatic Discharge, Invixium recommends the
use of a ground connection between each IXM device to a high quality
Earth Ground available at the install site.
Connect to Earth Ground in the following way:
1
Connect the green and yellow earthing wire from the wired back cover
(PIN 5) to the building earthing.
2
Connect the open end of earth ground wire provided in the Install Kit
Box to the building earthing as well.
3
Screw the lug end of the earth ground wire to the metal mounting plate.
Ensure all Earth Ground connections are made to each device prior to
turning on the power.
Earthing Wire from
Wired Cover (PIN 5) Building Earthing
Earth Ground
Wire Lug

Input Voltage
INVIXIUM recommended PoE Injector Specs
90-264 VAC, 60 Hz
Input Current 0.4 A @ 100 VAC
Output Voltage 48 VDC
Output Current 0.32 A
Power 15.36 Watt
Power It Up
When using an external power supply, ensure that
the regulated, filtered and dedicated power source
(Safety tested, FCC/IC/CE certified) provides a
minimum of 1A @ 12 VDC.
When using PoE, an IEEE 802.3af compliant Active
Midspan Injector is required (sold separately).
Refer to table for Invixium recommended PoE
Injector specs. Full PoE deployments should
include a centralized PoE PSE. Both IEEE 802.3af
power transmission modes (A and B) are
supported.
Invixium recommends the use of
battery back up or a UPS with built-in surge
protection to provide supply to PSE unit & DC
source.
WARNING: Product Warranty is void if improper power (under or over) is supplied to the device.

IXM WEB
Router connected
to LAN/WAN
Ethernet and Wi-Fi
For Ethernet communication, a specific range
of allowable IP addresses can be set for
improved security.
PoE+ connectivity is available on all devices
except MYCRO.
MERGE 2 does not support Wi-Fi
communication.
MERGE 2MERGE CR

RS-485 Configuration
For RS-485 networks, ensure that
IXM
devices are wired in a daisy chain configuration,
up to a maximum
of 31 devices. At a baud rate of 9600 bps, make certain that the
maximum cable length is not longer
than 1200 m (4000 ft).
IXM WEB
RS-485 to USB
Converter
MERGE CR
MERGE 2
R = 120 ohms for Standard RS-485 Cabling
R = 100 ohms for CAT5/6 Cabling
Bottom Connecter RS-485
SGND (19)
RS-485+ (4)
RS-485- (2)

Micro USB OTG Cable
(Sold Separately)(Sold Separately)
Bottom USB PortMicro USB Cable
USB Serial Communication
For Serial Communication, IXM devices are equipped with USB Aux port.
The USB port can be used to connect a Flash Drive via Micro USB OTG cable and perform
functions like upgrading firmware, downloading transaction logs and configuration files.
The USB port can also be used to connect to a PC running IXM WEB via Micro USB cable.

Standard 26-Bit Wiegand Format
Custom 35-Bit Wiegand Format
Trailing Parity
Bit (Odd)
Leading Parity
Bit (Even)
Leading Parity
Bit (Odd)
Even Parity
Flex Fields (12 Bits) ID (20 Bits)
Facility Code (8 Bits)
ID (16 Bits)
Trailing Parity
Bit (Odd)
Flex Fields* OtherOdd ParityEven ParityID Bits
*Flex Fields can be Facility Code, Job Code or Company ID Code.
0 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 341BIT
P F F F F F F F N N N N N N N N N N N N N N N N PF
P F F F F F F F F F F F F N N N N N N N N N N N N N N N N N N N N PP
Wiegand
IXM devices have the
option to use the
Standard 26-bit
Wiegand format or a
Custom Wiegand
format (up to 512 bits)
to suit any Access
Control System.
All IXM devices are set
to Standard 26-bit
format as a factory
default.
N P P F O

ACP Connections
Wiegand Connections
WDATA_OUT0
WDATA_OUT1
DGND
(10)
(9)
(7)
WDATA_OUT0
WDATA_OUT1
DGND
MERGE 2

DAC Connections (Electric Door Strike)
Snubber Diode
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NO
Door Strike Power Supply
RLY_COM
MERGE 2
DAC Connections
RLY_COM
RLY_NO
DAC_IN1
DAC_IN2
DAC_OUT
(18)
(17)
(12)
(11)
(6)
NOTE: A separate power supply is required for the door strike
Max Relay Rating = 2A @ 24VDC
Request
to exit
Electric
Door Strike
Door
Contact

RLY_COM
RLY_NC
DAC_IN1
DAC_IN2
DAC_OUT
(18)
(20)
(12)
(11)
(6)
DAC Connections (Magnetic Lock)
Snubber Diode
DAC_IN2
DAC_OUT
DAC_OUT
DAC_IN1
RLY_NC
Door Strike Power Supply
RLY_COM
MERGE
DAC Connections
NOTE: A separate power supply is required for the door strike
Max Relay Rating = 2A @ 24VDC
Request
to exit
Magnetic
Door Lock
Door
Contact

Enrollment Best Practices
Incorrect
Pressure
Position
Rotation
Condition
Dry
Wet
Too Low Too High
Good
Good
Correct
Preferred Fingers

1. Proper finger placement is crucial for good enrollment score and faster authentication.
2. Place your finger straight on the sensor as shown below, while covering the sensor with the top
third of your finger as shown on the previous page.
Finger Placement Best Practices
Correct
Incorrect

1. The location of the card reader on Invixium devices
depends on the product model.
2. For MERGE 2, the card reader is located below the
sensor, behind the emblem.
3. See the image on the right for the correct card
placement while using MERGE 2.
Card Placement
MERGE 2

Software Installation
1Go to www.invixium.com >> IXM WEB >> Get IXM WEB.
2You will be redirected to ixmweb.invixium.com. Click on the IXM WEB Tab. Provide the required
details and Click “Submit”. An email with the latest IXM WEB package will be sent to the email ID
provided.
3Extract the compressed file and run
IXM WEB
.exe.
4INVIXIUM recommends to select Install option for rapid
installation.
5When installation is complete, click Exit. IXM WEB icon
is now on the desktop.
6Run IXM WEB to launch in default web browser.
7Contact [email protected] in case of any issues.

INGUIDE
This is a Quick Start Guide. For a detailed guide please refer
the Invixium Installation Guide.
Enjoy the Experience.
Some features may vary based on device models. Copyright © 2020,
INVIXIUM. All rights reserved.
invixium.com
© 2020 Google Inc. All rights reserved. ChromeTM browser is a trademark of Google Inc.
Firefox logo®is a registered trademark of the Mozilla Foundation.
Windows®, Internet Explorer®and Edge®are trademarks of the Microsoft group of companies.
Safari®is a trademark of Apple Inc.
P/N XAD-00E-209-01G
For technical or customer support issues, please
contact your Local Authorized Reseller first.
Visit the Customer Portal for more Invixium resources at
www.invixium.com/support
Contact Invixium Support at:
+1 844 INVIXIUM (468 4948)
invixium_support
This manual suits for next models
1
Table of contents
Popular Security Sensor manuals by other brands

elobau
elobau eloProtect E 165ESK Series Translation of the original operating instructions

Wenglor
Wenglor IR2D001 operating instructions

Chauvin Arnoux
Chauvin Arnoux C.A762 user manual

Reed Instruments
Reed Instruments R5110 instruction manual

MSA
MSA 3S small quick start guide

ESA
ESA Corona CAD Operating and maintenance manual

GTE
GTE ADICOS M-BUSMASTER S operating manual

Honeywell
Honeywell FS19X Series Installation guide and operating manual

Danatronics
Danatronics ECHO FD quick start guide

Global Fire
Global Fire ZEOS-AD-S instructions

TeleAlarm
TeleAlarm leesys HM-LES900 quick guide

DAVIS
DAVIS Vantage Pro2 GroWeather 6820 user manual