Quick Guide
Neutron4-B Remote Pulse Collector
Copyright 2017 - ionSign www.ionsign.fi 13.2.2019 –v1.2
For example JAMAK 2x(2+1)x0,5mm2
instrumentation cable can be used
between the meter and Neutron4-B. The
relay output of a single meter is connected
to Neutron4-B as shown above.
Introducing Neutron4-B:
1. Insert SIM card to its slot, PIN query
disabled.
2. Connect the measuring device(s) and
antenna to the device.
3. Insert the battery or remove the factory
installed battery cover. The red led
lights up for 10 seconds.
4. Enter the installation mode by pressing
the button inside the device. The device
wakes up for five minutes to receive
SMS messages. The red GSM led
blinks twice at a time when GSM net-
work search is active, and once when a
GSM connection is established.
5. Send the SETTINGS command to the
device as an SMS. When the command
is received, the yellow led starts blinking
and the device starts to establish a
server connection. The yellow led re-
mains lit when the device is in opera-
tion.
When installation mode times out, all leds are switched off. This is normal.
SETTINGS 101 services.ionsign.fi 80 internet 4 1 /cloud/input/ 0
*Setting “0”for servers that only support hourly data. Ignoring parameter sets 60 minute cycle.
The above example command sets
device 101 to start collecting hourly
pulse data and send it to server ser-
vices.ionsign.fi, path /cloud/input/
and port 80, using internet as APN.
Device 101 has 4inputs and data is
sent one minute after 24 readings
have been collected. In this case, with
hourly data, at 00:01.
Red
GSM led
Antenna
SIM card
Battery
cover
Button
Pulse
connectors
Green, yellow
and red leds
Device
ID
Attached
meters
Server
name
Server
port
Server
path
Transmission
delay
Operator APN
address
Optional - Measurement cycle:
15, 30 or 60 (min) - 0=60min*
User and Installation Guide
Neutron4-B Remote Pulse Collector
Copyright 2017 - ionSign www.ionsign.fi 13.2.2019 –v1.2
1 General
Neutron4-B is a battery operated, grid independent pulse concentrator
designed for collecting and reporting pulses from pulsed consumption
meters, e.g. gas or water meters. The device stores the pulse data and
sends them to a server in batches of 24 readings.
During normal operation the leds and the GSM module are switched
off. They are only switched on automatically for the regular data trans-
mission and manually in the installation mode.
2 Indicator lights
The device saves battery power by switching the leds on only;
•when a battery has been installed, for 10 seconds (no pulse
indication)
•when installation mode has been entered by pressing the button
•when performing the daily data transmission
Yellow led is OFF
The device has no settings. Send a
SETTINGS command as an SMS
Yellow led is ON
The device has settings and is in operation
Yellow led blinks
The device has settings and is starting
communication to the server
Green led is OFF
The device is not in the GSM network
Green led is ON
The device is in the GSM network
Green led blinks
The device has poor GSM signal strength
Red GSM led blinks
twice at a time
The device is looking for a GSM network
Red GSM led blinks
The device is in the GSM network
Red Pulse led toggles
The device registered an incoming pulse
3 Commands
The device is controlled with SMS messages sent to the SIM card’s
number. Except for the STATUS command, the device doesn’t send
replies. In the messages, commands and parameters are separated by
one space character ( ˽in examples).
The device only receives SMS messages in the installation mode, at
other times the GSM module only has power when it’s sending data.
Installation mode can only be activated locally with the button. There
are ways to secure message delivery also remotely, contact ionSign
when this becomes relevant.
SETTINGS˽<Device identifier>˽<Server address>˽<Server port>˽
<APN>˽<Input count>˽<Transmission delay>˽<Server path>[˽<Step>]
With the SETTINGS command all required settings are given and
collecting and sending of pulse data is started.
Device identifier is a unique device ID. Range is 1-1000000.
Server address is the IP address of the server. Also a domain
name server name can be used. Maximum length is 50 characters.
Server port is the port number where the server application waits
for transmissions.
APN is the Access Point Name of your operator for the GPRS/3G
connection. Maximum length is 30 characters.
Input count is the number of connected meters. Range is 1-4.
Transmission delay helps to avoid a large number of devices
sending pulse data to the server at the same time. Range is 0-
1000 minutes. With value zero (0) the data is sent immediately
when 24 readings have been collected.
Server path is the path in the server where data is saved. Maxi-
mum length is 50 characters.
Step defines the length of the measurement cycle. Can be omitted,
defaults to zero (0). See STEP command for more instructions.
STEP˽<Time>
If only the measurement cycle needs to be changed from the one
set using the SETTINGS command, the STEP command is used.
The Time parameter defines the cycle length in minutes. Values: 0,
15, 30 or 60 minutes.
0: Hourly data, for servers only supporting hourly data.
15: Quarterly data collection and sending.
30: Half-hourly data collection and sending.
60: Hourly data collection and sending.
STATUS
To the STATUS command, the device replies with an SMS of gen-
eral status information. STATUS command has no parameters.
Status information includes the following:
•Device settings validity: [Yes | No].
(Also device ID, if the device has valid settings).
•Data sending to server initialized: [Yes | No].
•Most recent device IP connection initialized: [Yes | No].
•Most recent TCP/IP connection to server: [Yes | No].
•Most recent server reply to device data: [No | Success | Error].
•GSM operator name.
•GSM signal strength: [dBm value | Unknown].
Signal strength -113 dBm indicates a value of -113 dBm or less.
Signal strength -51 dBm indicates a value of -51 dBm or greater.
4 Failure recovery
For GSM network failures, the device has a built-in local buffer for
keeping collected data stored for later transmission. The buffer capacity
is 3 years for hourly data, 1,5 years for half-hourly data and 9 months
for quarterly data. When the GSM network resumes service, all buff-
ered data is sent to the server without any need for user intervention. If
the GSM signal strength is weak and the device often needs to buffer
data, battery life will be shorter than expected.
5 Neutron4-B technical specifications
•Inputs: 4 inputs for pulses.
•Replaceable battery. With the factory installed battery, expected
battery life is roughly 10 years. Battery: 3,6V 6Ah min 1500mA peak
current. Compatible types e.g. SAFT LSH14, ULTRALIFE ER26500M
and EVE ER26500M.
•Real-time clock.
•Size: WxHxD 145 x 90 x 55 mm (flanged PC plastic enclosure).
•Protection class: IP65.
•Operating temperature: -25 °C...+55 °C.
•RH: 5 % - 95 % non-condensing.
•Local data storage capacity, for each input channel:
o3 years for hourly data
o1,5 years for half-hourly data
o9 months for quarterly data
•Data communication: Integrated GSM/GPRS module. Conforming
the following directives and standards:
oR&TTE Directive 1999/5/EC (Radio Equipment & Telecommuni-
cations terminal Equipment)
oLow Voltage Directive 73/23/EEC and product safety Directive
89/336/EEC for conformity for EMC
oGSM (Radio Spectrum). Standard: EN 301 511 and 3GPP
51.010-1
oEMC (Electromagnetic Compatibility). Standards: EN 301 489-1
and EN 301 489-7
oLVD (Low Voltage Directive) Standards: EN 60 950
•Antenna: external, SMA connector.
6 Warranty
ionSign grants a warranty of two (2) years for all delivered devices and
software services. The warranty starts on the date of the delivery and it
covers material and manufacturing defects. The warranty does not
cover defects caused by improper use or installation nor does it cover
defects caused by factors out of ionSign’s control. These would be for
instance grid malfunction or service changes of network operators
services. ionSign delivers a new device to replace the defected one,
without cost. Alternatively, ionSign may repair the defected device. The
defected device must be returned to ionSign, if required, at ionSign’s
cost. The warranty does not cover dismantling, installation, and intro-
duction costs and the like. ionSign warrants that the provided software
essentially manage with their designed tasks, at the time of delivery. All
significant software defects are covered by the warranty. The defects
will be resolved without unnecessary delay. The resolution may be an
instruction to circumvent the defect. If the delivery includes third party
products or services, these are only covered by the applicable warranty
provided by that third party. Title to the delivered goods transfers to the
client, when the invoiced price is paid in full. All immaterial rights related
to devices and services remain the property of ionSign. If the service
was a design assignment, the client assumes the right to use and
further develop the assignment results. ionSign is eligible to use the
client’s name as a reference in its marketing. ionSign is not eligible to
disclose the order details without prior consent. In case of a force
majeure, preventing to act according to the purchase agreement, the
affected party will start immediate negotiations to assess the effects of
the obstacle on the scope and schedule of the purchase agreement.
ionSign appropriately backs up client’s data residing on its servers. In
spite of this, ionSign assumes no responsibility of possible damage due
to loss of data. ionSign assumes no responsibility of direct or indirect
damage to property or people, nor work or travel expenses, caused by
using its services or devices, unless due to gross negligence. ionSign’s
financial liability is always limited to the value of the delivered goods
and services, unless otherwise inflicted by the Finnish law.
ionSign Oy
P.O. Box 246 | Paananvahe 4 | FI-26100
Rauma | Finland | t. +358 2 822 0097
[email protected] | ionsign.fi | VAT FI21174499

Other ionSign Measuring Instrument manuals

ionSign Neutron3-B+ Installation guide

ionSign

ionSign Neutron3-B+ Installation guide

ionSign Neutron12-3G User manual

ionSign

ionSign Neutron12-3G User manual

ionSign Neutron4-3G User manual

ionSign

ionSign Neutron4-3G User manual

ionSign Neutron12-LAN User manual

ionSign

ionSign Neutron12-LAN User manual

Popular Measuring Instrument manuals by other brands

UE Systems ULTRAPROBE 10000 Pumps and Cavitation Inspection

UE Systems

UE Systems ULTRAPROBE 10000 Pumps and Cavitation Inspection

Kobold KSM Series User instructions

Kobold

Kobold KSM Series User instructions

National Instruments Module NI PXI-8250 installation guide

National Instruments

National Instruments Module NI PXI-8250 installation guide

Magnescale DF805SR instruction manual

Magnescale

Magnescale DF805SR instruction manual

Ecom DP Operation manual

Ecom

Ecom DP Operation manual

BEARING CHECKER SPM user guide

BEARING CHECKER

BEARING CHECKER SPM user guide

Young 27106 instructions

Young

Young 27106 instructions

HEINE iC1 quick start guide

HEINE

HEINE iC1 quick start guide

NOVOTEST ISM-U operating manual

NOVOTEST

NOVOTEST ISM-U operating manual

TESTO 330i Startup & Safety

TESTO

TESTO 330i Startup & Safety

YOKOGAWA ADMAG TI Series user manual

YOKOGAWA

YOKOGAWA ADMAG TI Series user manual

Amphenol PROTIMETER HygroMaster-L BLD7750L instruction manual

Amphenol

Amphenol PROTIMETER HygroMaster-L BLD7750L instruction manual

Texmate LEOPARD DL-40US-ACA manual

Texmate

Texmate LEOPARD DL-40US-ACA manual

CASTLE Sonus B Getting started guide

CASTLE

CASTLE Sonus B Getting started guide

emitor satlook Lite user manual

emitor

emitor satlook Lite user manual

ADC Prosphyg 760 Instructions for use

ADC

ADC Prosphyg 760 Instructions for use

Precision Digital Corporation ProtEX-MAX PD8-150 Series instruction manual

Precision Digital Corporation

Precision Digital Corporation ProtEX-MAX PD8-150 Series instruction manual

Sealey PP5 quick start guide

Sealey

Sealey PP5 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.