IP Power 9212 Delux User manual

IP Power 9212 Delux
User Manual

IP POWER 9212 USER MANUAL
USER MANUAL
IP POWER 9212Delux
Version: V1.00
2006.12
VER. X.X,
- 1 -

Warning:any changes to this equipment without permission may cause damages to your
equipment! This equipment has been proved to can be prevented from the influence of harmful
electronic jamming in normal business use condition.
IMPORTANT NOTICE
1. IP POWER 9212 Delux is deigned to be used in-door, we have no responsibility
for the possible damage in out-door use especially in the rain.。.
2. Please use the power adaptor provided by the dealer, we have no responsibility
for the possible damage in using other adaptors.
4. Do not use IP POWER 9212 Delux in strong shaking condition
5. Please contact the dealer If IP POWER 9212 Delux works improperly.
Copyright © 2006 All rights reserved. No part of this publication may be reproduced, stored
in a retrieval system, or transmitted in any form or by any means, electronic, mechanical,
photocopying, recording or otherwise, without the prior written consent of us
All trademarks and products mentioned in this document are the properties of us.
- 2 -

IP POWER 9212 USER MANUAL
Table of Content
1. INTRODUCTION..........................................................................................................4
FEATURES.........................................................................................................................
2.BEFORE YOU START.................................................................................................5
PACKAGE CONTENTS ........................................................................................................
MINIMUM SYSTEM REQUIREMENTS....................................................................................
3.INTERFACE DESCRIPTION .......................................................................................6
4.HARDWARE & SOFTWARE INSTALLATION..........................................................6
HDWARE INSTALLATION .....................................................................................................
9201 PRO HARDWARE CONNECT(RECOMMEND) ……………………………………… …
9202 PROHARDWARE CONNECT(RECOMMEND) ……………………………………… …
SOFTWARE INSTALLATION .................................................................................................
5. INITIALIZATION.........................................................................................................14
BASIC SETTING THROUGH ETHERNET ................................................................................ .
SETTING OF SOFTWARE SHUT DOWN CONTROLLED PC/ SERVER……………..……….
6. SETTING AND CONTROL THROUTH THE INTERNET.......................................17
SYSTEM CONFIGURATION.........................................................................................
ADVANCE SETING .......................................................................................................
SPECIAL INTER-CONTROL ………………………………………………………… …….
DDNS SETTING ……………………………………………………………………….…
SMTP FOR E-MAIL: INFORM IP ADDRESS & SENSOR TRIGGER. ………….……….
CONTROL DI THROUGH TIME SCHEDUEL ………………………………………...
CLOCK AND NTP SETTING………………………………………………………………….
NETWORK WAKE UP ……………………………………………………………………….
FIRMWARE UPDATE…………………………………………………………………………
7. SETING 9212 THROUGH THE INTERNET.............................................................31
8. APPLICATION ASSOCIATED TO OTHER IP RPODUCTS..................................32
9. FAQ.............................................................................................................................33
10. CONTROL AND SETUP BY HTTP COMMAND ..................................................33
11. WEBPAGE CUSTOMIZATION ..............................................................................36
VER. X.X,
- 3 -

1. Introduction
The IP Power 9212SDelux is a Network Controller & Sensor with 8 DI & 8 DO. A specific PC or
software is not needed; you can easily control devices remotely and check the device status via
the Internet anywhere in the world.
Using a Browser such as Internet Explore or Netscape, you can securely access the unit. It
includes 8 Digital Inputs ( Dry / Wet contact can be switched ) , 8 Digital Relay Outputs and
works like an IO Server. You can integrate it with Home / Office security, Personal entertainment,
and Industrial field applications.
The API program is supported to help the integrator to easy program any software to integrate
with existing application systems in local computers. The IP POWER 9212 can be flexibly applied
to Home entertainment & industry security & systems with integrated management.
Feature︰
1. Embedded web server – no need to connect to a PC – Use Ethernet or Internet (LAN / WAN)
2. Accessible with popular web browsers- IE (Internet Explore) or Netscape – DO NOT need
specific S/W.
3. Comes with 8DI & 8DO: Direct control relay output (DO) and detects digital input (DI)
* 8 Set Sensor – Default 4 Set Source mode (Dry - Voltage Input) and
& 4 Set Sink mode (Wet- Resistance Input).
Source& Sink mode could be switched .
* 8 Set Controllers – Default 4 Set NO - Normal Open & 4 Sets NC - Normal Close
4. Network protocols supported: HTTP, DDNS, DHCP, Virtual and Dynamic IP.
5. Support RS232 to control .
6. Security code identification and Hardware reset function.
7. Individual LED indicates switch-working status.
8. Safe, durable, non-electric leakage and anti-farmable design.
9. Polar protection – will even connect contrary port.
10. Digital inputs provide de-bouncing function.
11. Update firmware by the TCP/IP network.
12. Embedded “ WATCH DOG “,
15. Support SMTP: Send IP address as log in and send e-mail as detecting sensor trigger.
16. Auto Internal Control: DI Control DO (Own or other 9212Delux).
17 Timer Schedule -- pre-set the time schedule to turn power on / off thru Internet / Ethernet
18 Support NTP (Network Time Protocol) - synchronize the time of 9258 to the Internet web
19 WAP Mobile Phone Control - can use the GPRS cell phone via WAP to control
20 Setup up own outlet default: set DO status as regain power.
21 Provide SDK (VB & VC) for own Software develop and application.
22 Supply Exclusive IP Service for easily find on Internet by name.
Specification: 1. DC 5V (AC90-240 input) 2. D-SUB In & out port. 3. RJ45
Application field: can be associated with any kind of electrical equipments, no matter household
appliances or security equipment. It can manage the power supply through the web page; make
it be safer for the security equipment and more convenience for digital control at the far end.
- 4 -

IP POWER 9212 USER MANUAL
Industrial application field: bank, financial security system, jewels, casino, cash register in
supermarket, park, traffic control, military equipment and airport.
2.Before you start
9212 package contents
One set of IP POWER 9212
One network wire with RJ45 port
One 1A, 110~220V adaptor
TWO D-Sub 15 Pin cable
One install CD
One rapid install manual
Minimum System Requirements
* Minimum Intel Pentium II 300MHz/compatible AMD processor
* WINDOWS operating system (IE5.0+SP1)
* Minimum 64MB RAM
* VGA Card: with capability of displaying full-Colors and DirectDraw support
* Network card with RJ45 port
* Ethernet Hub / Router
* Internet network (Ethernet, xDSL or other ways, depends on whether you need far end control
ability or not)
VER. X.X,
- 5 -

3. Interface Description
IP Power 9212 has three devices, 9200 is the network module, and the followed picture
shows its interface:
9201 is the input /sensor module and 9202 is the output / control module
4. Hardware & Software installation
Before you star to use IP Power 9212, please follow the steps below:
Check the package to make sure the contents is complete.
Prepare one Ethernet HUB, or Router
Check the voltage of the power supply to make sure it is AC 110-240 volt
Hardware Installation: Connect RJ45 first (before connect POWER jack)
1 Connect the 9200 to HUB through RJ 45 netting cable.
2 Connect the 9200 ( IN-BLACK ) to 9201( BLACK port) &
9200 ( OUT- BLUE ) to 9202( BLUE) through D-SUB cable.
3 Connect the HUB to the Internet (May through ADSL/XDSL modem).
4 Connect the power adapter to the 9200.
Power on your computer and power adapter of IP POWER 9212.
- 6 -

IP POWER 9212 USER MANUAL
9201Pro Hardware connection (recommend):
4-1. Dry & Wet Setting
In 9212Delux, the DRY or WET contact of each input ( in 9201) can be switch.
To setup the Dry or Wet contact of each input signal , please open 9201 case and
adjust the two blue SWITCHs
There is two blue switch in 9201. Please arrange all the setup to ON in the Right Switch.
VER. X.X,
- 7 -

Then you can setup the Dry/Wet contact in left switch :
As no contact with the Input ,
Switch set as ON : LED light ON & means the input is Dry contact ,
Switch set as OFF : LED light is OFF which means the input is Wet contact
For example: the left switch setup input 1~4 is OFF & 5-8 is ON.
So the input 1- 4 is DRY contact and LED light OFF
the input 5- 8 is WET contact and LED light ON
- 8 -

IP POWER 9212 USER MANUAL
4-2 . Connection Illustration:
For different request of normal state of electric equipment, 9201 offers four sets of voltage
signal IN1-IN4 and four sets of shortcut circuit signals IN5-IN8.
9201 Pro provide 4set Source mode - Voltage Input – Out 1 ~ Out 4
ON : 4V~24V
OFF : 0V ~ 3V
4 set Sink mode - Resistance input – Out 5 ~ Out 8.
ON : 200 ohm~ 0 ohm
OFF : 500 ohm ~ ∞
1. The polarity: Right - Positive & Left – Negative .
NOTE: Because of the polarity protective function, it won’t damage the product if you reverse the
polarity in installation. But it will cause the product cannot work properly
2. Source mode ( Voltage signal ) -- IN1 & IN4: can be connected to voltage signal detectors such
as smoke detector, light detector and gas detector.
VER. X.X,
- 9 -

3. Sink mode ( Resistance signal ) —IN5 & IN8: can be connected to magnetic reed switch as
the follow figures
It can be installed in the entrance guard or security equipment such as doors, windows, drawers
and safe case..
Source mode ( Voltage input) :
IN1-IN4 contacts are active signal sensor. If the voltage difference between the two contacts in
one set within 0V~3V, 9212 shows ON. It the voltage difference within 4V~24V, 9212 shows
OFF. So user can detect the change of equipment. Such as smoke detector, light detector and
gas detector.
NOTE:
1. The data in this figure is the average
measure value. To ensure the correct
detection, we suggest user set the voltage
lower than 3V when it shows OFF and higher
than 4V when it shows ON
2. The maximum measure voltage is 24V.
.
- 10 -

IP POWER 9212 USER MANUAL
Slink mode (Resistance Input ) :
IN5-IN8 contacts are short circuit sensor. If the resistance between the two contacts in one set
within 0Ω~200Ω, 9212 shows ON. If the resistance within 500Ω~∞, 9212 shows OFF. So user
can detect the movement of equipment through the magnetic reed switch or other kind of
reactive sensors.
NOTE:
1. The data in this figure is the average
measure value. To ensure the correct
detection, we suggest user set the voltage
lower than 200Ωwhen it shows ON and higher
than 500Ωwhen it shows OFF.
2. When measure the resistance of web
contacts, the maximum voltage is 5V and the
maximum currency is no more than 10mA。
PS: magnetic reed switch: using the magnetic field of the magnet to produce a signal when there
is a movement happened in switch. Low cost and easy to use is the chief characteristic of
magnetic reed switch. Most of them are used in security equipment, living product and automatic
mechanism.
9202 Pro Hardware connection (recommend)
IP Power 9202 Pro offers 4 sets of NC(Normal Close ) – Out 1-Out 4
4 sets of NO (Normal Open ) –Out 5-Out 8.
Maximum Rated Voltage: 240V/AC, 60V/DC
Maximum Rated Currency: 12A AC/DC
Maximum rated voltage for Single relay : 24V/ 10A , 120V/ 10A , 250/ 7A
Maximum Switch time: Max 10ms
Environment Temperature: -30°C~ + 55°C
NOTICE: Only the professionals should operate the following operations in this section
and the common user DO NOT try it!
For example—Light ball
1 Use the electrical wire of the equipment:
Step 1 :Cut off the live wire.(Use a test pencil or screwdriver with voltage tester to identify the
live wire between the two wires of electrical wire.)
V
- 11 - ER. X.X,

NOTICE: this method must cut off the electrical wire of the household appliance. Please make
the decision after reading method 5-2 and 5-3.
Step 2: Use a test pencil or screwdriver with voltage tester to identify the live wire between the
two wires of electrical wire. Cut off the live wire and connect to the port of IP Power 9212. Use the
test pencil or screwdriver with voltage tester again to make sure the connection is
correct.
NOTICE: BE CAREFUL IN THIS OPERATION AND DO NOT TOUCH THE WIRE UNDER
VOLTAGE WITH ANY PART OF YOUR BODY, ESPECIALLY WITH YOUR HANDS
2. Use additional electrical wire: you can buy some electrical wire and outlet in the electrical
shop to cooperate with IP Power 9212, avoid cutting off the electrical wire of the equipment
and can be used flexible in all kind of electrical equipment.
NOTICE: Use a test pencil or screwdriver with voltage tester to identify the live wire
between the two wires of electrical wire and make sure of connecting the live wire to the
port of IP Power 9212.
- 12 -

IP POWER 9212 USER MANUAL
3. You an control multi power by use the power extension cord
NOTICE: Do not connect too much energy intensive electrical equipment such as air
conditioner, electrical heater, microwave over or over in the same electrical
outlet. Too much electrical currency may cause fire. This product not guaranties
the possible damage because of too much electrical currency.
Software installation
Please follow the steps below to install the software.
1. Insert the CD in package and windows will auto-run. If not please browser the file
Autorun.html in CD. Chose the langrage you can read.
2. Click IP KamVid 1070 in driver of CD and click OPEN top install the driver procedure.
3. Please follow the wizard to install all the program we suggest.
4. After install , you can see the shortcut of “IPEDIT” & “INFINITY Cam” on Desktop and in
program list of start
NOTE:
* For NEW function – Record “ WMV” format , please do install IP KamVid 1070 .
VER. X.X,
- 13 -

5. Initialization
1. Initial Ethernet setup IPEDIT
Click “ipEdit.exe” . Please affirm the power of
9212A-SL had been turn on and the Ethernet connection of RJ45 is correct.
A. LOCAL Devices area:
IPEDIT will searching all IP Products 9XXX series in the same local Ethernet, the default
name of 9212Delux is IP Power, and display the information as select
1. Double click the IP address, it will be covered by dark stripe, its name, and IP will be displayed
below. The IP address of 9212Delux should in the same subnet with your PC, subnet mask,
and default gateway mast same as 9212Delux also.
For example, the IP address of 9212Delux is 192.168.10.9, so your computer needs to add an IP
address looks like 192.168.10.XXX to get connection to 9212Delux.
2. User can change its name (please use numbers or letter) or IP (please set in the same subnet
as your PC) in the text windows. Then click Submit after setting finish. After about 20 seconds,
the new setting will work. Click Update, the new setting of equipment will display in text window.
3. You can also click “REF” in IPEDIT to check your PC to get the subnet information. And
directly press “APPLY to “ amend the IP setting of selected 9212A-SL
NOTICE:
1. Make sure the RJ45 network wire have been connected correctly and the 9212 are power on.
2. It can obtain the virtual IP address after you run the ipeditv3.exe only if the Ethernet support
DHCP. Click the IP address to enter the web page. If the Ethernet not support DHCP, IP92XX will
change it’s IP address to fixed IP address. Please follow the steps below to change the subnet of
your PC:
- 14 -

IP POWER 9212 USER MANUAL
3. If can not get in the 92XX web page , please set the segment of IP 9212Delux to be same as
your PC.
* You can get your PC network information – IP Addres, Subnet Mask and Default Gateway by
step: start execute key “cmd” in dialog key “ipconfig” in MS-DOS mode
The last digit of IP address can be any number between 1~254, but can not be same as
your PC. If using in any PC, just use HUB and type the 192.168.0.100 in Browser or use
“ipedit.exe “ then you can get in the webpage.
* Same SEGMENT : The first 3 number of IP address is same - XXX.XXX.XXX.abc. The part
of XXX is same. Fro Example : IP address is 192.168.1.100 , then another IP address
192.168.1.123 is the IP in same segment .
4. The default username and password of IP Power 9212 are:
Username: admin Password: 12345678
If forget the new password , you can key in superuser in username , and hardware reset the
device to set the default setting Password : 12345678 。( for security concern) ).
Note : if stay for long time as in webpage , you would be unable setting and see message
“ Cookie time out “ , please go to IE to change setting: “ Tools “ “ Internet operations ” ,
please click “ Delete Cookies “ and “Delete files “ in “ Temporary Internet file “.
VER. X.X,
- 15 -

B. Internet online devices:
By setting the server address in IP server of advanced setup page, user can easily to get the IP
address of IP Power 9212Delux on internet by name searching. The default IP address of IP
server is 220.135.169.136.
Step1: click “connect” green button Step2: type the keyword in “ device name
- 16 -

IP POWER 9212 USER MANUAL
6. Control and settings through the Internet
Double click the IP address in IPEDIT and you can enter the login web page. Input the default
password 12345678( you can change the password after log in ), click the OK and then you can
enter the Web Control page.
Username: admin / Password: 12345678
Sensor of IP Power 9212: Read IO
Source mode (Voltage input):
IN1-IN4 contacts are active signal sensor. If the voltage difference between the two contacts in
one set within 0V~3V, 9212 shows ON. It the voltage difference within 4V~24V, 9212 shows
OFF. So user can detect the change of equipment. Such as smoke detector, light detector and
gas detector.
Sink mode (Resistance Input):
IN5-IN8 contacts are short circuit sensor. If the resistance between the two contacts in one set
within 0Ω~200Ω, 9212 shows ON. If the resistance within 500Ω~∞, 9212 shows OFF. So user
can detect the movement of equipment through the magnetic reed switch or other kind of
reactive sensors.
NOTE:
1. The data in this figure is the average measure value. To ensure the correct detection, we
suggest user set the voltage lower than 200Ωwhen it shows ON and higher than 500Ωwhen it
shows OFF.
VER. X.X,
- 17 -

2. When measure the resistance of web contacts, the maximum voltage is 5V and the maximum
currency is no more than 10mA。
Click the refresh button and you will see the similar figure like this. It represents the state of the
four sets of input signals (there may be some delay, it up to your network).
Control of IP Power 9212: SET IO
IP Power 9212 now can control 8 outputs at the same time.
* Out1 & Out4 are normal close switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turnoff. When it is off, the corresponding LED light off, the
circuit between the two connects is turn on.
* Out5 & Out8 are normal open switches. When it is on, the corresponding LED lights up, the
circuit between the two connects is turn on. When it is off, the corresponding LED light off, the
circuit between the two connects is turn off.
- 18 -

IP POWER 9212 USER MANUAL
1. Set the output’s state to ON/OFF
Click the output you want to change, set it to ON or OFF state and click apply
Button to finish the setting.
2. Set one output be in ON/OFF state at the appointed time
You can set the state when one output starts, either ON or OFF. You can also set
the delay time and the action when the delay time is up. Then click apply button to
confirm it. The example shows in the figure above means the OUT3 will be in ON state
when it starts and will changes the state to OFF after 30 seconds.
3. Reset the ON/OFF settings
Click the reset button you can cancel the previously output settings.
System configuration:
*Setting the IP address for IP Power 9212Delux:
Click the “ Setup “ button on the left side; fill in the proper IP address, Subnet Mask, Default
Gateway, DNS. If you choose to use DHCP, please make sure that your network support DHCP
service so the IP Power 9212 will search and gain an IP address automatically when it starts. You
can also control the Beeper sound.
* Http Command Verification: setup the control possibility from HTTP command or
SDK (VB & VC)
VER. X.X,
- 19 -
Other manuals for 9212 Delux
1
Table of contents
Other IP Power Controllers manuals
Popular Controllers manuals by other brands

Emerson
Emerson FISHER T208VR Series instruction manual

iLive
iLive Mixer Plus user guide

Data Aire
Data Aire Mini dap4 Installation, operation & maintenance manual

Carrier
Carrier 40VAM-C8FATEE installation manual

Omron
Omron CPM1 - PROGRAMING 02-2001 Programming manual

Danfoss
Danfoss A333 Series Mounting guide