welcome@IP44.de . www.IP44.de 00 05/20
1. Push mainscable through cable entry part of the wall
bracket and ensure tight seal.
2. Attach wall bracket. Pay attention of position „top“.
Use the washer gaskets with rubberized face against
to the wall bracket. Seal unused mounting holes.
3. Establish ground connection and connect power lines.
4. Hook light housing into notch of the wall bracket. Press
luminaire to the wall bracket and tight set screws flush
and evenly. Avoid pinched cables.
5. Turn the protection cover of the sensor by 180° to the
right.
6. Time setting: before switching on power, turn the time
anti-clockwise to min.. Switch on power. After 30 sec
the sensor changes to stable working state. After
turning off the light, check the function and switch on
the light again. Provided that there is no continuous
detection signal, the light should turn off within 5 sec.
cut control
instructions for use
7. Lux setting: when the light-control is turned anti-
clockwise to min and the unit is tested by daytime, the
light should not turn on. Cover the detection window
with an object (simulating night) and the light should
turn on.
8. If everything is set correctly, the time-control can be
adjusted to set the lighting time and the lux-control to
select the lux.
9. Turn back the protection cover of the sensor by 180°
to the left to protect the small adjusting wheels and to
ensure the motion detection.
lux-control time-control
IP44
welcome@IP44.de . www.IP44.de 00 05/20
Lichttechnik:
230V Power LED/3000K
system performance: 16,5 W/ 1078 lm
EEK
Technische Daten:
operating voltage: 230V / 50Hz
protection class
safety class 1
Luminaire is suitable for mounting on normal inflammable
surfaces.
conformity mark
detection range: 9 m max.
time setting: 5 sec – 8 min
detection angle: 120°
light-control: 10-2000 (adjustable)
working temperature: -25~+45°C
sensor information:
see pictures below:
A+
Note:
Please don’t adjust the two functional controllers too much.
That is because the two functional controllers are connected
to the components directly. There is a small stopper in each
of the two components. When you adjust the controllers from
start to end, the excessive turn will damage the stopper, and
lead to the 360°non-stop turn around. Please consider that
the adjust range limit is 270°.
Factory setting: Light-control is max, time setting is min.
• Unrest objects hinder the correct initial operation of the
sensor.
•In front of the detection area there should be no
obstacles or unrest objects eecting detection.
• Avoid an installation near air temperature alteration
zones, such as: air condition, central heating, etc.
•In case of a problem after installation, please contact
your retailer and for safety reasons never open the
housing!
maintenance:
Disconnect the electrical installation.
This luminaire contains built-in LED lamps. The LED lamps can
be replaced by IP44.de in case of a failure of the LED. In this
case, please get in touch with your retailer.
care:
Regularly clean luminaire from dirt and deposits. Do not use a
high pressure cleaner for cleaning. Please note care instruc-
tions at www.IP44.de.
safety:
We point out that the electric connection of light fixtures has
to be done by a certified installer. We assume no accoun-
tability for damages which are a result of non-appropriate
mounting or application of the luminaire. Modifications on the
luminaire will result in loss of warranty.
max. 9 m
0,7–2m
-120°
max. 9 m
max. 0,7–2m
-120°

Other IP44.de Outdoor Light manuals

IP44.de piek mini solar join User manual

IP44.de

IP44.de piek mini solar join User manual

IP44.de reed M solar User manual

IP44.de

IP44.de reed M solar User manual

IP44.de cherry bubbls solar User manual

IP44.de

IP44.de cherry bubbls solar User manual

IP44.de intro control User manual

IP44.de

IP44.de intro control User manual

IP44.de qua 93825-BB User manual

IP44.de

IP44.de qua 93825-BB User manual

IP44.de Cut Control User manual

IP44.de

IP44.de Cut Control User manual

IP44.de lix spike solar join User manual

IP44.de

IP44.de lix spike solar join User manual

Popular Outdoor Light manuals by other brands

Prilux Hexagon ARENA-PLAY instruction manual

Prilux

Prilux Hexagon ARENA-PLAY instruction manual

STERNO HOME GL23101 manual

STERNO HOME

STERNO HOME GL23101 manual

Jula 422-203 installation instructions

Jula

Jula 422-203 installation instructions

LIGMAN LH-10685 installation manual

LIGMAN

LIGMAN LH-10685 installation manual

SLV Elektronik QUADRASYL D instruction manual

SLV Elektronik

SLV Elektronik QUADRASYL D instruction manual

Briloner MAL 1361 Mounting instructions

Briloner

Briloner MAL 1361 Mounting instructions

AVE 45787 quick start guide

AVE

AVE 45787 quick start guide

Principal LED Street Wrap Gen 2 installation guide

Principal LED

Principal LED Street Wrap Gen 2 installation guide

Holiday Living Y517-1516020237-FD manual

Holiday Living

Holiday Living Y517-1516020237-FD manual

Garden Gear G3974 instruction manual

Garden Gear

Garden Gear G3974 instruction manual

LI-TIAN LIGHTING LT-XT-08 installation instructions

LI-TIAN LIGHTING

LI-TIAN LIGHTING LT-XT-08 installation instructions

Silverwood CPLT1874 Assembly instructions

Silverwood

Silverwood CPLT1874 Assembly instructions

Philips CityMood BSP672 manual

Philips

Philips CityMood BSP672 manual

Philips Ledino 168109316 brochure

Philips

Philips Ledino 168109316 brochure

LUCIDE NINKE-LED manual

LUCIDE

LUCIDE NINKE-LED manual

Maretti RIVINGTON 13.3590.04 quick start guide

Maretti

Maretti RIVINGTON 13.3590.04 quick start guide

Zafferano LD0402 operation instruction

Zafferano

Zafferano LD0402 operation instruction

Aurora EN-HBD100MS quick start guide

Aurora

Aurora EN-HBD100MS quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.