welcome@IP44.de . www.IP44.de 00 05/20
1. Push mainscable through cable entry part of the wall
bracket and ensure tight seal.
2. Attach wall bracket. Pay attention of position „top“.
Use the washer gaskets with rubberized face against
to the wall bracket. Seal unused mounting holes.
3. Establish ground connection and connect power lines.
4. Hook light housing into notch of the wall bracket. Press
luminaire to the wall bracket and tight set screws flush
and evenly. Avoid pinched cables.
5. Turn the protection cover of the sensor by 180° to the
right.
6. Time setting: before switching on power, turn the time
anti-clockwise to min.. Switch on power. After 30 sec
the sensor changes to stable working state. After
turning off the light, check the function and switch on
the light again. Provided that there is no continuous
detection signal, the light should turn off within 5 sec.
cut control
instructions for use
7. Lux setting: when the light-control is turned anti-
clockwise to min and the unit is tested by daytime, the
light should not turn on. Cover the detection window
with an object (simulating night) and the light should
turn on.
8. If everything is set correctly, the time-control can be
adjusted to set the lighting time and the lux-control to
select the lux.
9. Turn back the protection cover of the sensor by 180°
to the left to protect the small adjusting wheels and to
ensure the motion detection.
lux-control time-control
IP44
welcome@IP44.de . www.IP44.de 00 05/20
Lichttechnik:
230V Power LED/3000K
system performance: 16,5 W/ 1078 lm
EEK
Technische Daten:
operating voltage: 230V / 50Hz
protection class
safety class 1
Luminaire is suitable for mounting on normal inflammable
surfaces.
conformity mark
detection range: 9 m max.
time setting: 5 sec – 8 min
detection angle: 120°
light-control: 10-2000 (adjustable)
working temperature: -25~+45°C
sensor information:
see pictures below:
A+
Note:
Please don’t adjust the two functional controllers too much.
That is because the two functional controllers are connected
to the components directly. There is a small stopper in each
of the two components. When you adjust the controllers from
start to end, the excessive turn will damage the stopper, and
lead to the 360°non-stop turn around. Please consider that
the adjust range limit is 270°.
Factory setting: Light-control is max, time setting is min.
• Unrest objects hinder the correct initial operation of the
sensor.
•In front of the detection area there should be no
obstacles or unrest objects eecting detection.
• Avoid an installation near air temperature alteration
zones, such as: air condition, central heating, etc.
•In case of a problem after installation, please contact
your retailer and for safety reasons never open the
housing!
maintenance:
Disconnect the electrical installation.
This luminaire contains built-in LED lamps. The LED lamps can
be replaced by IP44.de in case of a failure of the LED. In this
case, please get in touch with your retailer.
care:
Regularly clean luminaire from dirt and deposits. Do not use a
high pressure cleaner for cleaning. Please note care instruc-
tions at www.IP44.de.
safety:
We point out that the electric connection of light fixtures has
to be done by a certified installer. We assume no accoun-
tability for damages which are a result of non-appropriate
mounting or application of the luminaire. Modifications on the
luminaire will result in loss of warranty.
max. 9 m
0,7–2m
-120°
max. 9 m
max. 0,7–2m
-120°

Other IP44.de Outdoor Light manuals

IP44.de piek mini solar join User manual

IP44.de

IP44.de piek mini solar join User manual

IP44.de intro control User manual

IP44.de

IP44.de intro control User manual

IP44.de qua 93825-BB User manual

IP44.de

IP44.de qua 93825-BB User manual

IP44.de lix spike solar join User manual

IP44.de

IP44.de lix spike solar join User manual

IP44.de cherry bubbls solar User manual

IP44.de

IP44.de cherry bubbls solar User manual

IP44.de reed M solar User manual

IP44.de

IP44.de reed M solar User manual

IP44.de Cut Control User manual

IP44.de

IP44.de Cut Control User manual

Popular Outdoor Light manuals by other brands

Kanlux ZARA HR-40 manual

Kanlux

Kanlux ZARA HR-40 manual

bover Nans R manual

bover

bover Nans R manual

LEDDOO ECLIPSE SL-1 user manual

LEDDOO

LEDDOO ECLIPSE SL-1 user manual

FLOS TOIO manual

FLOS

FLOS TOIO manual

Lunux HELLUX 195 instruction manual

Lunux

Lunux HELLUX 195 instruction manual

LIGMAN AA-10086-2 installation manual

LIGMAN

LIGMAN AA-10086-2 installation manual

Hubbell AIRO installation instructions

Hubbell

Hubbell AIRO installation instructions

HEPER NORMA LB6055.510-US Installation & maintenance instructions

HEPER

HEPER NORMA LB6055.510-US Installation & maintenance instructions

LIGMAN TRIANGLE 6 installation manual

LIGMAN

LIGMAN TRIANGLE 6 installation manual

LIGMAN OD-50001 installation manual

LIGMAN

LIGMAN OD-50001 installation manual

Reliance Foundry R-7535 Installation

Reliance Foundry

Reliance Foundry R-7535 Installation

Home Decorators Collection HB7261-293 Use and care guide

Home Decorators Collection

Home Decorators Collection HB7261-293 Use and care guide

Maxim Triumph VX manual

Maxim

Maxim Triumph VX manual

Hubbardton Forge Edge 302560 Assembly/installation instructions

Hubbardton Forge

Hubbardton Forge Edge 302560 Assembly/installation instructions

Anslut 004743 operating instructions

Anslut

Anslut 004743 operating instructions

LIGMAN BRISBANE 7 installation manual

LIGMAN

LIGMAN BRISBANE 7 installation manual

STERNO HOME GL22627 manual

STERNO HOME

STERNO HOME GL22627 manual

Santa & Cole Urbidermis SLOPE INDUSTRIAL FACILITY manual

Santa & Cole Urbidermis

Santa & Cole Urbidermis SLOPE INDUSTRIAL FACILITY manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.