IPC ST-35IPC User manual

IP camera tester
User Manual
(V01.00)

Thank you for purchasing the IP camera tester. Please read the manual before using the IP camera
tester and use properly.
For using the IP camera tester safely, please first read the「Safety Information」carefully in the
manual.
The manual should be kept well in case of reference.
Keep the S/N label for after-sale service within warranty period. Product without S/N label will
be charged for repair service.
If there is any question or problem while using the IP camera tester, or damages occurred on the
product, please contact our technical Department.

Content
1 .Safety information...............................................................................................................................1
2. IP Camera Tester Introduction.............................................................................................................2
2.1 General ......................................................................................................................................2
2.2 Packing list ................................................................................................................................2
2.3 Function interface......................................................................................................................3
3. Operation.............................................................................................................................................5
3.1 Installing the Battery..................................................................................................................5
3.2 Instrument connection................................................................................................................6
3.2.1 IP camera connection..............................................................................................................6
3.2.2 Analog camera connection......................................................................................................7
3.2.3 HD Coaxial camera connection...............................................................................................7
3.3 OSD menu .................................................................................................................................8
3.3.1 Lite mode........................................................................................................................8
3.3.2 Drop-down Menu............................................................................................................9
3.3.3 Screen capture...............................................................................................................10
3.3.4 TesterPlay .....................................................................................................................10
3.3.5 Rapid video...................................................................................................................12
3.3.6 IP discovery ...............................................................................................................13
3.3.7 Rapid ONVIF test .........................................................................................................14
3.3.8 IP camera test................................................................................................................26
3.3.9 Video monitor test.........................................................................................................28
3.3.10 CVI camera test...........................................................................................................34
3.3.11 TVI camera test...........................................................................................................39
3.3.12 AHD camera test.........................................................................................................40
3.3.13 Network tool ...............................................................................................................42
(1)PING Test ....................................................................................................................42

(2)IP address scan.............................................................................................................42
(3)Network test (Ethernet bandwidth test) ........................................................................43
(4)Port Flashing................................................................................................................46
(5)DHCP server................................................................................................................47
(6)Trace route...................................................................................................................48
(7)Link monitor ................................................................................................................49
3.3.14 Rapid IP Discovery .....................................................................................................49
3.3.15 Audio Record..............................................................................................................50
3.3.16 Data monitor ...............................................................................................................50
3.3.17 Audio player................................................................................................................51
3.3.18 Video Player................................................................................................................52
3.3.19 RTSP Player................................................................................................................52
3.3.20 Hik test tool.................................................................................................................54
3.3.21 Dahua test tool ............................................................................................................56
3.3.22 Update.........................................................................................................................59
3.3.23 Office..........................................................................................................................60
3.3.24 Browser.......................................................................................................................60
3.3.25 DroiNotes....................................................................................................................61
3.3.26 System Setting.............................................................................................................62
3.3.27 File explorer................................................................................................................66
3.3.28 Theme.........................................................................................................................67
3. 4 Audio test................................................................................................................................69
3.7 DC12V 1A power output.........................................................................................................70
4. Specifications ....................................................................................................................................71
4.1 General Specifications .............................................................................................................71

Page.1.
1 .Safety information
◆The tester is intended to use in compliance with the local rules of the electrical usage and avoid to apply
at the places which are inapplicable for the use of electrics such as hospital, gas station etc.
◆To prevent the functional decline or failure, the product should not be sprinkled or damped.
◆The exposed part of the tester should not be touched by the dust and liquid.
◆During transportation and use, it is highly recommended to avoid the violent collision and vibration of
the tester, lest damaging components and causing failure.
◆Don’t leave the tester alone while charging and recharging. If the battery is found severely hot, the
tester should be powered off from the electric source at once. The tester should not be charged over 8
hours.
◆Don’t use the tester where the humidity is high. Once the tester is damp, power off immediately and
move away other connected cables.
◆The tester should not be used in the environment with the flammable gas.
◆Do not disassemble the instrument since no component inside can be repaired by the user. If the
disassembly is necessary indeed, please contact with the technician of our company.
◆The instrument should not be used under the environment with strong electromagnetic interference.
◆Don’t touch the tester with wet hands or waterish things.
◆Don’t use the detergent to clean and the dry cloth is suggested to use. If the dirt is not easy to remove,
the soft cloth with water or neutral detergent can be used. But the cloth should be tweaked sufficiently.

Page.2.
2. IP Camera Tester Introduction
2.1 General
The 3.5 inch IPS touch screen IP camera monitor is designed for maintenance and installation of IP
cameras, analog cameras,TVI, CVI AHD cameras, as well as testing 4K H.264 /4k H.265 camera by
mainstream, The 480x320 resolution enables it to display network HD cameras and analog cameras in
high resolution. The unit supports many ONVIF PTZ and analog PTZ control. The combination of
touch screen and key buttons make the IP camera tester very user- friendly.
The tester is also a great tool for Ethernet network testing. It can test PoE power voltage, PING, and IP
address searching. You can use the blue cable tracer to locate individual connected cables from a bundle
of cables. Test LAN cable for proper connection termination. Other functions include providing testing
IP and analog at the same time, DC 12V 1A power output and much more. Its portability, user-friendly
design and many other functions make the IP tester an essential tool for all installers or technicians.
2.2 Packing list
1). Tester
2). Adaptor DC12V 1A
3) Network cable tester
4) Polymer lithium ion battery (3.7V DC 3000mAh)
5). BNC cable
6). RS485 cable
9). Output Power cable
10). Audio cable
12). Safety cord
13). Tool bag
14). Manual

Page.3.
2.3 Function interface
1
The charge indicator: it lights red while the battery is being charged. As the
charging is complete, the indicator turns off automatically
2
The RS485 data transmission indicator: it lights red while the data is being
transmitted
3
Press more than 2 seconds, turn on or off the device ,short press to turn on or off
the menu display
4
Confirm key /zoom key
5
Return/Close : Return or cancel while setting parameters of the menu, close or
decrease the aperture
6
Function switching key

Page.4.
Top interface
Left interface Right interface
Bottom interface
7
Video signal input(BNC interface)/AHD,CVI and TVI input (BNC interface)
8
DC5V1.5A USB charging interface

Page.5.
9
DC12V1A power output , for provisional DC power supply
10
RS485 Interface: RS485communication for the PTZ
11
Audio input
12
Battery slot
13
Lan port
14
Micro SD card moveable (supports up to 32GB)
3. Operation
3.1 Installing the Battery
The tester has built-in lithium ion polymer rechargeable battery. The battery cable inside battery
cabin should be disconnected for safety during transportation!
Prior to the use of the instrument, the battery cables inside the battery cabin should be well
connected.
Pressing the key continuously can power on or off the tester.
Notice:Pls use the original adaptor and connected cable of the device!
When the battery icon is full or the charge indicator turns off automatically, indicate the battery
charging is completed
Notice: When the Charge Indicator turns off, the battery is approximately 90%
charged. The charging time can be extended for about 1 hour and the charging time within 12
hours will not damage the battery.
Notice :Press the key several seconds to restore the default settings when the

Page.6.
instrument works abnormally.
Multi-meter: the red and black multi-meter pen must insert the corresponding port.
Warnings:Instrument communication port is not permitted access circuit voltage over 6V,
otherwise damage the tester.
3.2 Instrument connection
3.2.1 IP camera connection
Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester’s
LAN port, if the link indicator of the tester’s LAN port is green and the data indicator flickers, it means
the IP camera and the IPC tester are communicating. If the two indicators don’t flicker, check if the IP
camera is powered on or the network cable is not functioning properly.
Note:1) If the IP camera requires PoE power, then connect the IP camera to the IP tester’sLAN port .
The tester will supply PoE Power for the IP camera. Click on the icon labeled POE to turn the PoE
Power off or on.
2) If use the tester’s menu to turn off the tester’s PoE power supply, the PoE switch and the power
sourcing equipment are allowed to connect to the tester’s PSE port, and the PoE power will be supplied
to the IP camera by the tester’s LAN port. On this condition, the tester cannot receive data from IP
camera, but the computer connected to the PoE switch can receive the data via the the tester.

Page.7.
Warning: Poe switch or PSE power sourcing equipment only can be connected to tester “PSE
IN” port, otherwise will damage the tester.
3.2.2 Analog camera connection
(1) Connect the camera's video output to the IP tester’s VIDEO IN. The image will display on the tester
after pushing the PTZ icon
(2) CCTV IP Tester “VIDEO OUT” interface connect to the Video input of monitor and optical video
transmitter and receiver, the image display on the tester and monitor
(3) Connect the camera or the speed dome RS485 controller cable to the tester RS485 interface ,(Note
positive and negative connection of the cable).
3.2.3 HD Coaxial camera connection
* CVI, TVI, AHD camera are classified as HD coaxial cameras. Hereby the following instruction of
how to connect CVI camera to the tester is also applied to CVI, TVI and AHD camera.

Page.8.
(1) Connect the CVI camera's video output to the IP tester’s “Video IN” interface, the image will
display on the tester. The tester only come with CVI input interface. There is no CVI output interface.
(2) Connect the CVI camera or the speed dome RS485 controller cable to the tester RS485 interface.
3.3 OSD menu
◼Press the key 2 seconds to turn on
◼Press the key 2 seconds to turn off
◼short press the key to enter sleep mode,press it again to test if tester work abnormally
and cannot be turned off , Press the key several seconds to turn off, the tester reset
3.3.1 Lite mode
◼Lite mode: You can easy find corresponding apps

Page.9.
◼In Lite mode, Press the icon several seconds, can move the icon to other apps
◼In lite mode, click the finger icon in the lower right corner to release lock icon, move icons and
change function icons sequence.
Click SD card, install or remove SD card.
3.3.2 Drop-down Menu
Press and slide at right top right corner twice to open shortcut menu. The shortcut menu includes IP
settings, CVBS, LAN, Brightness, settings etc.

Page.10.
CVBS: Click icon “CVBS “to enter, you can test IP and analog camera at the same time.
LAN: Display network port or WIFI connection real-time upload and download speeds and other
network parameters.
Settings: Enter settings interface.
IP: Enter IP Settings interface.
3.3.3 Screen capture
long press the key “enter”, can capture screen interface and save it in any time.
You can go file management to view “file management –sdcard- Pictures—Screenshots
3.3.4 TesterPlay
Mobile screen projection (Only for android version)

Page.11.
The meter creates WIFI hotspot, connect mobile phone to the tester’s WIFI hotspot, or the tester and
mobile phone connect to the same Wi-fi network. Tap icon “ ”, then select “TesterPlay” app to
enter, click “Start”button to generates two-dimensional code, Please use mobile phone scan it, then
download and install the client software, you can view the screen real-time projection.
PC screen projection:
Install VLC player in the PC, turn on the VLC player "Media - Open Network Streaming", and
input the RTSP address of on the top instrument two-dimensional code, click "play" to view the
screen real-time projection.

Page.12.
3.3.5 Rapid video
Press enter function, One key to detect all network cameras and auto play the images.
Auto log in and display camera image. Detailed operation refer to ONVIF function

Page.13.
After exit ONVIF app, Click Refresh to search ip address.
3.3.6 IP discovery
Press IP discovery ,tester auto-scan the whole network segment IP, as well as
auto-modify the tester‘s IP to the same network segment with the scanned camera's IP.
Local IP:Tester’s IP address, Tester can auto-modify the tester‘s IP to the same network segment with
the scanned camera's IP
Discovery IP:Connected tester equipment’s IP address. If the camera connected to the tester directly,
tester will display the camera’s IP address, if tester connects to Local Area Network, it displays the
current IP address.

Page.14.
Temp IIP:After searching IP address, the modified tester’s IP address will not be saved, if you do not
select “Temp IP,” the modified tester’s IP address will auto-save after searching.
Start:PING function, Click "Start", can PING camera’s IP
Rapid ONVIF: Rapid ONVIF Quick link
IPC TEST: IPC TEST Quick link
Applicability: Using IP discovery app ,you don’t need to know the first two digits of camera’s IP
address , it can auto-scan the whole network segment IP, and auto-modify tester’s IP address , greatly
improved engineering efficiency .
3.3.7 Rapid ONVIF test
Rapid ONVIF can display 4K H.265/H.264 camera image by tester mainstream, one key to activate
Hikvision camera
Press enter ONVIF function, the meter auto scan all ONVIF cameras in different network
segments. It lists cameras name and IP address on the Left of screen. Tester can auto login camera and
display camera image. Factory default use admin password to auto login, if you modified the password,
then default use the modified password to login
If you select ONVIF Rapid mode, the meter automatically scan different network segments for ONVIF
cameras. It lists the camera name and IP address on the Device List. Tester can auto login camera and
display camera image.

Page.15.
Click the button “Refresh”, tester will scan the ONVIF camera again. Click the newly displayed ONVIF
camera on the “Device List“. The tester will show the IP camera’s relative information and settings.
Activate HIKVISION Camera: When connected unactivated HIKVISION Camera, tester can auto
recognized ,And prompt "The camera is not active, you need to activate it", click "OK" to start activate .
Enter a new password for the camera

Page.16.
When comes out “activate success” prompt, click login to display camera image.
Pop-up settings menu when click the “ONVIF setting ”icon in the upper left corner
Table of contents
Other IPC Test Equipment manuals
Popular Test Equipment manuals by other brands

Sentinel
Sentinel JetFlush X100 technical information

Tektronix
Tektronix MSO4000B Series user manual

IDEAL Networks
IDEAL Networks SignalTEK CT Quick reference guide

Keysight Technologies
Keysight Technologies M8085A installation guide

Extech Instruments
Extech Instruments PRC15 user manual

YOKOGAWA
YOKOGAWA 2553A user manual