IPEX PH232Y12 User manual

Doc No: PH232Y12-UM-001
IPEX
(IP Electronix)
16 January 2022
USER’S MANUAL
PH232Y12
#1 to #2 RS-232 ISOLATED HUB (REPEATER & ISOLATOR and Y-Switch)

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 2 of 12 Doc No.: PH232Y12-UM-001
16 January 2022

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 3 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
CONTENTS
1. INTRODUCTION ........................................................................ 4
2. SPECIFICATIONS ....................................................................... 4
3. PACKAGE CHECKLIST................................................................. 5
4. TOP VIEW................................................................................. 6
5. BOTTOM VIEW ......................................................................... 6
6. FRONT VIEW............................................................................. 6
7. BACK VIEW............................................................................... 6
8. RS-232 SERIAL PORTS PIN CONFIGURATION .............................. 7
9. PH232Y12 CONNECTION DIAGRAM........................................... 8
10. RS-232 CONNECTING METHODS ............................................. 9
11. GUARANTEE......................................................................... 12
12. TECHNICAL SUPPORT ........................................................... 12

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 4 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
1. INTRODUCTION
IPEX PH232Y12 is a 1 to 2 RS-232 HUB that provides #2 RS-232 (Full Duplex) ports from one single
RS-232 port. It works with Baud-Rate from 300bps to 230400bps. Using this device, you can connect
a RS-232 line, to 2 different devices.
PH232Y12 can also be used as a RS-232 Repeater, Amplifier and Y-Switch. All communications are
Full-Duplex. In addition, 3kV Optical and Electrical insulations have been used in the design of this
device, this means all the ports are insulated from each other, so using this device in the RS-232
line, can be very effective in eliminating electrically and electromagnetically noises. Also, the length
of the RS-232 line increases from 15m to 30m (15m on each side).
Protection against Surge, ESD and EMI is considered in its design, so, PH232Y12 is good for industrial
usage and are useful for Industrial Automation, Telecommunications, SCADA systems, DCS
systems...
2. SPECIFICATIONS
RS-232 Repeater, HUB, Isolator and Amplifier;
Number of Ports: #1 RS-232 to #2 RS-232 Bi-Directional HUB;
Serial Standard: Meets or Exceeds the Requirements of TIA/EIA-232-F and ITU v.28 Standards;
RS-232 Signal: TxD, RxD, GND;
RS-232 Parity: Even, Odd, None, Mark and Space;
Fully Plug & Play;
Wide Range Power Supply: +8V to +48V DC;
Serial Transmission Speed up to 230.4 kbps;
Power (Green) LED Indicator;
Transmit (Blue) and Receive (Yellow) LED Indicator;
Isolation Protection: 3kV Instantaneous, 500V DC Continuous;
Surge Protection: Embedded 1500W Surge Protection;
Magnetic Isolation: 1.5 kV Built-in;
ESD Protection: RS-232 Bus-Pin ESD Protection Exceeds ±15 kV Using Human-Body Model (HBM);
Dimensions: 145mm x 118mm x 27mm (5.70in x 4.65in x 1.06in);
Operating Temperature: -10°C to +70°C (+14°F to +158°F);
1 Year Guarantee and 5 Years Support.

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 5 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
3. PACKAGE CHECKLIST
Before installing the PH232Y12, verify that the package contains the following items:
1) #1 PH232Y122) #1 RS-232 Male to Female Cable
3) #1 Document and Driver CD-ROM 4) #2 DB9 Female Connector
5) #1 220V AC to 12V DC Adaptor 6) #2 Din Rail Brackets with the corresponding screws
NOTE: Notify your sales representative if any of the above items is missing or damaged.

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 6 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
4. TOP VIEW
5. BOTTOM VIEW
6. FRONT VIEW
7. BACK VIEW

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 7 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
8. RS-232 SERIAL PORTS PIN CONFIGURATION
1
2
3
4
5
6
7
8
9
PIN
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
NAME
INPUT
OUTPUT
INPUT
INPUT
INPUT
OUTPUT
OUTPUT
INPUT
GROUND
TYPE
Data Terminal Equipment (DTE)
1
2
3
4
5
6
7
8
9
PIN
DCD
RxD
TxD
DTR
GND
DSR
RTS
CTS
RI
NAME
OUTPUT
INPUT
OUTPUT
OUTPUT
OUTPUT
INPUT
INPUT
OUTPUT
GROUND
TYPE
Data Communication Equipment (DCE)

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 8 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
9. PH232Y12 CONNECTION DIAGRAM

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 9 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
10. RS-232 CONNECTING METHODS
-Modem Connection (to a Modem, any DCE devices)
Modem or other DCE devices
DB9-Female Pin Number
DTE
DB9-Male Pin Number
Pin 1: DCD (Output)
Pin 1: DCD (Input)
Pin 2: RxD (Output)
Pin 2: RxD (Input)
Pin 3: TxD (Input)
Pin 3: TxD (Output)
Pin 4: DTR (Input)
Pin 4: DTR (Output)
Pin 5: GND (Ground)
Pin 5: GND (Ground)
Pin 6: DSR (Output)
Pin 6: DSR (Input)
Pin 7: RTS (Input)
Pin 7: RTS (Output)
Pin 8: CTS (Output)
Pin 8: CTS (Input)
Pin 9: RI (Output)
Pin 9: RI (Input)
(Modem Cable)

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 10 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
-Null Modem Connection (to PC, PLC, RTU or any other DTE devices)
PC,PLC or other DTE devices
DB9-Male Pin Number
DTE
DB9-Male Pin Number
Pin 7: RTS (Output)
Pin 1: DCD (Input)
Pin 3: TxD (Output)
Pin 2: RxD (Input)
Pin 2: RxD (Input)
Pin 3: TxD (Output)
Pin 6: DSR (Input)
Pin 4: DTR (Output)
Pin 5: GND (Ground)
Pin 5: GND (Ground)
Pin 4: DTR (Output)
Pin 6: DSR (Input)
Pin 8: CTS (Input)
Pin 7: RTS (Output)
Pin 7: RTS (Output)
Pin 8: CTS (Input)
Pin 1: DCD (Input)
Pin 7: RTS (Output)
(Null Modem Cable)

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 11 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
-Simple Null Modem Connection (to PC, PLC… Without Hardware Flow control)
PC,PLC or other DTE devices
DB9-Male Pin Number
DTE
DB9-Male Pin Number
Pin 3: TxD (Output)
Pin 2: RxD (Input)
Pin 2: RxD (Input)
Pin 3: TxD (Output)
Pin 5: GND (Ground)
Pin 5: GND (Ground)
(Simple Null Modem Cable (Without Hardware Handshaking))

www.ipelectronix.com
IPEX (IP Electronix) PH232Y12: User’s Manual
Page 12 of 12 Doc No.: PH232Y12-UM-001
16 January 2022
11. GUARANTEE
All products manufactured by IPEXare under warranty regarding defective materials for a period of
one year from the date of delivery to the original purchaser.
12. TECHNICAL SUPPORT
If you have any technical question or need any technical support, please contact us using this Email
address: support@ipelectronix.com.
Table of contents
Other IPEX Switch manuals
Popular Switch manuals by other brands

SMC Networks
SMC Networks SMC TigerCard 10G installation guide

Pepperl+Fuchs
Pepperl+Fuchs HiC284 Series manual

EUCHNER
EUCHNER NZ.VZ Series operating instructions

Atlantis Land
Atlantis Land A07-ES3526VA-PoE Technical features

Triax
Triax TMS 17XX SE A-EU Series user guide

Zenith
Zenith ZTSDH Series Operation and maintenance manual

Omron
Omron D4N Series brochure

Juniper
Juniper EX9253 quick start

Cisco
Cisco Catalyst Series Switch 2940 Regulatory compliance and safety information

B&B Electronics
B&B Electronics Elinx EIR510-2MC-T user manual

Lilin
Lilin PS3188C Quick installation guide

Rose electronics
Rose electronics CTP-4P Installation and operation manual