AO000219
Safety systems
Accessories
Dimensions 26,6x44x81 (not mounted)
Aluminium housing
Laserclass 2
Installation performed through one of two lateral grooves
of the safety light curtain housing
Mounting brackets in storage box
Voltage supply with batteries
Description
äter
noch möglich.
Thanks to its completely new housing and fixing system
AO000219 laser pointer can be installed in all safety
light
curtains profiles of OY32, OY35 and OY36 series. Thanks
to a specially designed CAM fixing
equipment the laser
pointer can be
inserted into one of the two lateral grooves
either from the top or from
the side, depending on which
kind of fixing brackets have been used to mount the safety
light curtain
(standard “L” or TOP-BOTTOM Rotating ones).
One top and one lateral fixing bracke
ts, together with two
tightening knobs, allow to adjust
AO000219 laser pointer’s
position in both transversal and longitudinal directions and
to have it constantly centred respect
light curtain’s optical
axis, independently from housing width.
.
Typical applications
The AO000219 laser pointer is advised to be used to ease
transmit-
ter
and receiver mechanical alignment process in the following
installation conditions:
•
Mutli-beam body/access protection safety light curtain whose ope-
rating distance is more than 25m;
•
Mutli-beam body/access protection safety light curtain installed
with deviating mirrors to perform perimetric protections;
•
Finger or hand protection safety light curtains installed with
deviating mirrors to protect different sides of a machine.
Laser-Pointer
for OY32, OY35, OY36
MANUAL • Subject to alteration! Version: March 2012
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
info@ipf.de • www.ipf.de 2
Drawings
The laser pointer is powered by two 1.5 V AAA type batteries, take care to respect
right polarity. Battery replacement:
With a common cross head screw driver remove the 2 TSP UNI
7688 M2,5x8 screws from bottom closing cap then remove it to
have access to the battery box; put off the battery box, extract the
two batteries and replace with new ones. Place the battery box in its
place, close with the cap and firmly tighten the screws.
• Exhausted batteries are designated for separate collection at an appropriate collection point.
• Do not dispose of as household waste.
• For more information, contact the local authorities in charge of waste management.
minimum Lengh
maximum Length
MANUAL • Subject to alteration! Version: March 2012
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
info@ipf.de • www.ipf.de 3
Installation
• Install the emitting and receiving units of the OY32 / 35 / 36 series safety device in the defined positions (refer to
MECHANICAL MOUNTING chapter of the safety light curtain instructions manual). The use of floor stands is recom-
mended, verifying that they are firmly fixed and that their axis is perpendicular to the floor.
• AO000219 laser pointer is installed on OY32 / 35 / 36 safety light curtains profiles using one of the two lateral
grooves. Depending on which kind of fixing bracket is used, laser pointer can be mounted side way or slotted from
the top. Side mounting is compulsory when the accessory is installed on OY32 / 36 curtains with TOP-BOTTOM rota-
ting brackets.
Top mounting
Insert the “b” ensemble inside the lateral groove keeping the couple
of cams in vertical position (Fig. 1) until you’ve reached the right po-
sition (Fig. 3)
Side mounting
Insert the “b” ensemble abutting on the curtain side
corresponding to the lateral groove. Keep the
couple of cams in horizontal position (Fig. 2) and
after they entered the groove rotate them of 90° (Fig. 3).
Bring close the “d” bracket to the “b” ensemble completely and tigh-
ten the knurled knobs to firmly fix the system.
Fix the “c” bracket to the “a” ensemble using one of the four knurled
knobs, without tightening it completely in order to allow the mutual ad-
justment between “c” bracket and the laser pointer itself (Fig. 3).
As shown in the previous figures it’s sufficient to place such obtained as-
sembly on the light curtain front panel to have a first rough positioning.
Bring close, then, the “d” bracket to the “b” ensemble tightening com-
pletely the corresponding knurled knobs (Fig. 4).
Fig. 1
a
b
c d
Fig. 2
Fig. 3
MANUAL • Subject to alteration! Version: March 2012
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
info@ipf.de • www.ipf.de 4
At this point screw last knob fixing together both the “c”
and “d” brackets.
Tighten the knob firmly keeping the laser pointer group
close to the front panel of the curtain.
Laser pointer is positioned inside the detection field of
the safety device and thus inhibits the functioning
during the alignment phase. In case of safety devices
for access control, this inconvenience can be avoided
by positioning the laser pointer in a zone not affected by
optic groups. The device functioning is thus not
inhibited and the alignment results can be observed
directly on the receiving unit’s signalling LEDs.
Alignment
1) Power on the laser pointer rotating pushing the dedicated switch. Orientate the emitting unit in order that the
laser beam hits the receiving unit at the same height of the pointer.
NOTE: The holes of the fixing bracket or the orientable supports or the rotating brackets, available as ac-
cessories, can be used to orientate the unit, allowing angle adjustment along the vertical unit axis.
If necessary the inclination of the floor stand can be changed by simply mounting washers under the
base.
2) Repeat this procedure inserting the pointer in the lower part of the emitting unit; if necessary repeat this proce-
dure unit the desired result is obtained.
3) Insert the laser pointer in the upper part of the receiving unit and orient this unit in order that the laser beam
hits the emitting unit as indicated.
4) Repeat this procedure inserting the laser pointer in the lower part of the receiving unit.
After this operation, fix the position of the light curtain remove the laser pointer from controlled area and switch
on the safety device and verify the correct alignment.Finally, centre the laser pointer transversal position keeping
it close to the front panel, fix defiantly
NOTE: The laser pointer, due to mechanical tolerance problems in the matching with the light curtain hou-
sing, provides an approximate indication and hence small corrections may be necessary in the unit
alignment, following the ALIGNMENT PROCEDURE described in the safety light curtain instructions
manual.
Fixing
• To disengage the laser pointer is enough to totally unscrew the knobs and partially the remaining ones.
completely
tightend
Fig. 4

Popular Security System manuals by other brands

AVS Electronics VECTOR Plus installation manual

AVS Electronics

AVS Electronics VECTOR Plus installation manual

X10 Powerhouse DS7000 owner's manual

X10

X10 Powerhouse DS7000 owner's manual

IEH Flammex profi Series manual

IEH

IEH Flammex profi Series manual

Magos SR-500 user manual

Magos

Magos SR-500 user manual

Adtech ACA 140 instruction manual

Adtech

Adtech ACA 140 instruction manual

Clas Ohlson MC-03 instruction manual

Clas Ohlson

Clas Ohlson MC-03 instruction manual

Honeywell GKP-S8M Installation instructions and instructions for use

Honeywell

Honeywell GKP-S8M Installation instructions and instructions for use

Gemini 839 Series Installation and use manual

Gemini

Gemini 839 Series Installation and use manual

Aiphone AVD-S instructions

Aiphone

Aiphone AVD-S instructions

IR LAB LIR-IG89 user manual

IR LAB

IR LAB LIR-IG89 user manual

SECO-LARM SLI 820R owner's manual

SECO-LARM

SECO-LARM SLI 820R owner's manual

Chuango G5 user manual

Chuango

Chuango G5 user manual

Britax BFR1000 Series Installation & operation manual

Britax

Britax BFR1000 Series Installation & operation manual

Honeywell VISTA-128FBPT user guide

Honeywell

Honeywell VISTA-128FBPT user guide

Panasonic WV-CW4C instructions

Panasonic

Panasonic WV-CW4C instructions

Omega Engineering I SERIES I/32 quick start

Omega Engineering

Omega Engineering I SERIES I/32 quick start

DEASINO TECHNOLOGY DS-Beacon-05A user manual

DEASINO TECHNOLOGY

DEASINO TECHNOLOGY DS-Beacon-05A user manual

C&S YA40 quick guide

C&S

C&S YA40 quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.