MANUAL • Subject to alteration! Version: March 2012
ipf electronic gmbh
• Rosmarter Allee 14 • 58762 Altena
│
Tel +49 2351 9365-0 • Fax +49 2351 9365-19
│
info@ipf.de • www.ipf.de 4
At this point screw last knob fixing together both the “c”
and “d” brackets.
Tighten the knob firmly keeping the laser pointer group
close to the front panel of the curtain.
Laser pointer is positioned inside the detection field of
the safety device and thus inhibits the functioning
during the alignment phase. In case of safety devices
for access control, this inconvenience can be avoided
by positioning the laser pointer in a zone not affected by
optic groups. The device functioning is thus not
inhibited and the alignment results can be observed
directly on the receiving unit’s signalling LEDs.
Alignment
1) Power on the laser pointer rotating pushing the dedicated switch. Orientate the emitting unit in order that the
laser beam hits the receiving unit at the same height of the pointer.
NOTE: The holes of the fixing bracket or the orientable supports or the rotating brackets, available as ac-
cessories, can be used to orientate the unit, allowing angle adjustment along the vertical unit axis.
If necessary the inclination of the floor stand can be changed by simply mounting washers under the
base.
2) Repeat this procedure inserting the pointer in the lower part of the emitting unit; if necessary repeat this proce-
dure unit the desired result is obtained.
3) Insert the laser pointer in the upper part of the receiving unit and orient this unit in order that the laser beam
hits the emitting unit as indicated.
4) Repeat this procedure inserting the laser pointer in the lower part of the receiving unit.
After this operation, fix the position of the light curtain remove the laser pointer from controlled area and switch
on the safety device and verify the correct alignment.Finally, centre the laser pointer transversal position keeping
it close to the front panel, fix defiantly
NOTE: The laser pointer, due to mechanical tolerance problems in the matching with the light curtain hou-
sing, provides an approximate indication and hence small corrections may be necessary in the unit
alignment, following the ALIGNMENT PROCEDURE described in the safety light curtain instructions
manual.
Fixing
• To disengage the laser pointer is enough to totally unscrew the knobs and partially the remaining ones.
completely
tightend
Fig. 4