IQsocket IQSW-GSM User manual

User guide www.IQsocket.eu
Intelligent power
sockets
IQsockettm WALL / IQSW-GSM
…makes your life more comfortable
User
Guide
IQSW-GSM
documentation v1.1.4 R1
(for firmware v1.1.4)

User guide www.IQsocket.eu
1. Introduction..................................................................................... 3
2. Product description ........................................................................... 3
3. Installation ...................................................................................... 5
4. Managing outputs - basics ................................................................. 5
4.1 Managing outputs by SMS ............................................................. 5
4.2 Managing output power socket by phone call ................................... 7
4.3 Controlling output power socket manually ....................................... 7
5. Security features .............................................................................. 7
5.1 Basic security settings .................................................................. 8
5.2 Security list ................................................................................. 8
6. Command confirmation settings ......................................................... 9
6.1 Confirmation settings for SMS commands ....................................... 9
6.2 Confirmation settings for phone calls .............................................. 9
7. Measuring temperature ..................................................................... 9
7.1 Thermostat ................................................................................10
7.2 Temperature calibration ...............................................................10
8.Other commands ..............................................................................10
9. Alarms and microrelay .....................................................................11
9.1 External detector alarms ..............................................................11
9.2 Temperature alarms ....................................................................12
9.3 Generated alerts .........................................................................12
9.4 Alarm logs..................................................................................13
9.5 External detectors –scheme ........................................................13
9.6 Microrelay –scheme....................................................................13
10. Date and time ...............................................................................13
11. Scheduler .....................................................................................14
12. Original settings ............................................................................14
12.1 Reset to factory default procedure...............................................14
13. Firmware upgrade..........................................................................15
14. LED indicators ...............................................................................15
15. Technical specification ....................................................................16
16. Care and security recommendations.................................................16

2009 NETCONS, s.r.o.
Page 3 of 16
1. Introduction
It’s a fact that communication technologies help us to live our lives easier.
There was never such an importance of data networking features
implementations at products which have had no networking features in the
past. Need of data communication in companies even in homes is specially
visible in this Internet age. Intelligent power socket IQsocket IQSW-GSM is
a member of wide product family of intelligent sockets which helps people to
run some tasks remotely. These IQsocket products has following main features:
Various communication data interfaces
Various number of output power sockets
Different power socket types for different countries
Different inputs / outputs
IQsocket products help to control and monitor any appliances no matter where
they are placed. In your company, in your homes or weekend/holiday houses.
2. Product description
Intelligent power socket IQsocket IQSW-GSM helps to control any appliance
remotely over GSM network using by mobile phone. IQSW-GSM is managed by
SMS messages or phone call. It can work also as a independent thermo
regulator because of integrated thermometer which control appliance by turning
on/off according to preconfigured temperature rules.
IQsocket IQSW-GSM provides following features to customers:
Output power socket and microrelay output control
Appliance control over SMS, by call or manually
Remote power turnon/turnoff of 230V appliance
Remote power turnon/turnoff of output circuit up to 48V
Remote power turnoff for specified time
Remote appliance restart
Remote appliance status switch (turnon to turnoff or back)
Remote temperature measuring
Thermostat feature
Scheduler
Alarm detection
- External detector of motion, gas, fire, water; not included with product
- External detector of opened door, window, shake detector; not included with product
- other external detector

2009 NETCONS, s.r.o.
Page 4 of 16
Output power socket: This power
socket is intelligent, controlled remotely
by phone.
Input power socket: Input of 230V
power for product and also for
connected appliance.
Output power spočet can be in load of 16A max.
Input for detectors: Used for external
detectors generating alarms.
Microrelay: Switched contact by
microrelay.
SIM socket: Socket for SIM card.
Push-push type.
Manual button: Used to turn on/ off
output power socket manually or reset
product to default values.
Temperature sensor: Provides
temperature data.
Detail of temperature sensor
Temperature sensor measure
environmental temperature and
provide it over SMS on request. Output
power socket can be also controlled by
this sensor in thermoregulating mode.

2009 NETCONS, s.r.o.
Page 5 of 16
3. Installation
There are few connectors, SIM socket
and manual button on the bottom of
power socket.
Enter SIM card into SIM socket and
push until its fixed
Authorisation can be turned off using by mobile phone by inserting SIM card
into mobile phone and disabling PIN usage by phone software. After this step
you can pull out SIM card from phone.
- Insert SIM card with inactive PIN usage into power socket’s SIM socket
- In case of active PIN, GSM indicator starts blinking fast
- Plug you power socket into wall socket 230V
- Indicators will start blinking in few seconds, then basic test is started for 10
seconds
- If all is OK, red POWER indicator is turned on
- GSM indicator is blinking periodically (green light) –while searching GSM
networks; after it’s logged - blinking every 3 seconds.
- RELAY indicator should light on/off if output power socket in turned on/off
- Product is ready now for your use.
4. Managing outputs - basics
4.1 Managing outputs by SMS
Commands are sent in form of SMS messages to SIM card call number which is
in intelligent socket slot. Messages has following syntax:
pinCOMMAND (e.g. 3366STATUS)
- With pre-configured security password by command SMSPIN=3366
NOTE: Before SIM is finally used, please turn off PIN authorization.

2009 NETCONS, s.r.o.
Page 6 of 16
COMMAND (e.g. STATUS)
- with uncofigured security password/SMSPIN
There are two kinds of commands:
Control commands (labeled as Ctrl in tables)
oUsed to control of the IQSW-GSM and can be used at any time. Security settings, such
as SMSPIN, permitted callers list, DO apply.
Configuration commands (labeled as Cfg in tables)
oAllows to configure the IQSW-GSM parameters and functions. Their use is limited by
time to 10 minutes after device has been powered on or after last configuration
command has been received. Security settings, such as SMSPIN, permitted callers list,
DO NOT apply.
Command are not case sensitive. Messages longer than 30 characters are
deleted without any error response.
Command
Description
Response
Type
TURNOFF
Output power socket and
microrelay are turned off
TurnedOFF
Ctrl
TURNON
Output power socket and
microrelay are turned on
TurnedON
Ctrl
TURNOFF1
Output power socket is turned
off
TurnedOFF1
Ctrl
TURNON1
Output power socket is turned
on
TurnedON1
Ctrl
TURNOFF2
Microrelay is turned off
TurnedOFF2
Ctrl
TURNON2
Microrelay is turned on
TurnedON2
Ctrl
TURNOFF=123
Output power socket is turned
off for 123 minutes. Maximal
acceptable value is 180.
TurnedOFF 123 min
Ctrl
TURNON=123
Output power socket is turned
on for 123 minutes. Maximal
acceptable value is 180.
TurnedON 123 min
Ctrl
RESTART
Changes status of output power
socket and microrelay (negation,
microrelay only if
ALARMSWITCH=0) to pre-
configured time by command
RESTARTTIME.
Restarted
Ctrl
STATUS
Request for power socket
status: output power socket
status, temperature, GSM signal
TurnedOFF, TEMP: 25C, Signal: 35
%, INPUT=NOTCONNECTED,
Time=rr/mm/dd,hh:mm:ss,
ALARM: ACT
Ctrl
CREDIT*XX#
Check credit value on SIM card
YOUR CREDIT IS xxx
Ctrl

2009 NETCONS, s.r.o.
Page 7 of 16
4.2 Managing output power socket by phone call
Output power socket can be managed also by call using by mobile phone or
fixed phone. In such a case –power socket runs some action immediately.
Action can be output power interruption (appliance reboot), negating output
power socket status or other action. Action must configured in advance.
Message
Description
Response
Type
RING=SWITCH
If this parameter is configured,
status of output power socket is
changed (negated) by phone call.
RING=SWITCH –OK
Conf
RING=RESTART
If this parameter is configured,
output power socket is turned on
for time configured by RESETTIME
parameter.
RING=RESTART –OK
Conf
RING=NOACTION
No action is performed on phone
call
RING=NOACTION –OK
Conf
RING?
Information message: Request for
ring action configuration
RING=(NOACTION),RE
START,SWITCH
Conf
RESTARTTIME=XX
Configures time in seconds for
RESTART action. Maximal number
is 180.
RESTARTTIME=XX –
OK
Conf
RESTARTTIME?
Information message: Request for
RESTARTTIME configuration
parameter
RESTARTTIME=30
seconds
Conf
4.3 Controlling output power socket manually
Output power socket can be managed also manually by hidden button on
bottom side near the SIM slot. Button can be activated by suitable thin
mechanic tool. Pressing this button causes switching output power socket to
negative value.
5. Security features
Product can be configured for advanced security to disable control of the power
socket by unauthorized persons. Power socket uses two security methods:
Allowing only authorized phone numbers
Authentication by password/SMSPIN number
In case of first option –device will ignore all SMS and calls from unauthorized
phone numbers. If security is not configured, anyone who knows SIM card
calling number can control power socket remotely. Power socket uses security
lists for this purpose. This list supports 7 phone numbers max.
NOTE: Configuration commands are accepted only within first 10 minutes
after intelligent power socket is plugged in. It is from security reasons.
Configuration SMS messages are typed by Bold.

2009 NETCONS, s.r.o.
Page 8 of 16
In case of SMSPIN use - individually or along with security lists, it is
important to put SMSPIN command right before SMS command without any
space or special character as shown here:
pinCOMMAND (e.g.. 3366STATUS)
- With preconfigured password/SMSPIN ; SMSPIN=3366
5.1 Basic security settings
Security can be configured and viewed simply by following messages.
Command
Description
Response
Type
SECNUMBER=NO
Security phone lists are turned
off/inactive.
SECNUMBER=NO
–OK
Conf
SECNUMBER=YES
Security phone lists are turned
on/active for configured phone
numbers.
SECNUMBER=YES
–OK
Conf
SECNUMBER=LIST
Request for full list of secured
numbers.
LIST
421903123456,42
1903111222,4212
35678235
LIST - NO
NUMBER!
Conf
SMSPIN=xxxx
Configuration of SMS
password/SMSPIN.
SMSPIN=xxxx –
OK
Conf
SMSPIN=NOPIN
Using of password/SMSPIN is
deactivated.
SMSPIN=NOPIN –OK
Conf
SMSPIN?
Request for SMSPIN configuration.
SMSPIN=(NOPIN),
1234
Conf
SMSWWW=YES
Controlling by SMS from Internet is
allowed.
SMSWWW=YES –
OK
Conf
SMSWWW=NO
Controlling by SMS from Internet is
disabled.
SMSWWW=NO –
OK
Conf
SMSWWW?
Request for SMSWWW configuration
SMSWWW=(NO),Y
ES
Conf
5.2 Security list
Security list allow configuring up to 7 numbers and up to 15 digits for one
phone number.
Command
Description
Response
Type
SECNUMBER+4212
33355777
Add new number to security list.
SECNUMBER+421
233355777 –OK
Conf
SECNUMBER-
421233355777
Delete specific number from security list.
SECNUMBER-
421233355777 –
OK
Conf
NOTE: password (SMSPIN), which is use dis different than traditional PIN
code, which is usually assigned by GSM operator or assigned by user on
SIM card. It is kind of IQsocket password called SMSPIN and is used for
SMS message authentication and has the same structure as standard PIN =
4 numbers.

2009 NETCONS, s.r.o.
Page 9 of 16
SECNUMBER-ALL
Delete all numbers from security list
SECNUMBER-ALL –
OK
Conf
SECNUMBER?
Request for security list configuration.
SECNUMBER
=(NO),YES,LIST
Conf
Security lists accept only numbers in international syntax:
Example: SECNUMBER+421265440655 means add number +421-2-65440655
Example: SECNUMBER-421265440655 means delete number +421-2-
65440655
421 is country code in this example and 2 is city code.
6. Command confirmation settings
It is important to make you sure if command was executed successfully when
communicating with IQsocket. For this purpose we implemented notifications of
each executed command. If you activate this notification, you will be informed
about each command execution. In case of SMS commands, you will be notified
by back SMS. In case of managing by phone call, your command will be
confirmed by back phone call to your mobile phone.
6.1 Confirmation settings for SMS commands
Command
Description
Response
Type
SMSCONFIRM=YES
SMS confirmation is turned on for all SMS
commands
SMSCONFIRM=YES –
OK
Conf
SMSCONFIRM=NO
SMS confirmation is turned off for all SMS
commands
SMSCONFIRM=NO –
OK
Conf
SMSCONFIRM?
Request for SMS confirmation settings
SMSCONFIRM=NO,(Y
ES)
Conf
6.2 Confirmation settings for phone calls
Command
Description
Response
Type
RINGCONFIRM=YES
Phone call confirmation is turned on for all
commands. Hang off after 10 seconds
RINGCONFIRM=YES
–OK
Conf
RINGCONFIRM=NO
Phone call confirmation is turned off for all
commands
RINGCONFIRM=NO –
OK
Conf
RINGCONFIRM?
Information message: Request for call
confirmation settings
RINGCONFIRM=NO,(
YES)
Conf
7. Measuring temperature
GSM power socket has built in thermostat. This thermostat enable to measure
temperature of environment and provide it over SMS. It also enables to act as
a temperature regulator to control output power socket or output microrelay
circuit. Device enables to configure two temperature thresholds which control
output power socket. This is just supplemental feature of power socket with
accuracy ±2 ˚C due to using inexpensive thermostat instead of using
expensive precise external thermostat. This feature cannot replace professional
thermostat.
Command
Description
Response
Type

2009 NETCONS, s.r.o.
Page 10 of 16
STATUS
Information message: Request for basic
status: output power socket status,
temperature and GSM signal
TurnedOFF, TEMP:
25C, Signal: 35 %
Ctrl
THERMOSTAT=YES
Activates temperature monitoring
THERMOSTAT=YES
–OK
Ctrl
THERMOSTAT=NO
Deactivates temperature monitoring
THERMOSTAT=NO
–OK
Ctrl
TEMPON=XX
Temperature limit for turning on of output
power socket –if temperature threshold is
reached or passed
TEMPON=XX –OK
Ctrl
TEMPOFF=XX
Temperature limit for turning off of output
power socket –if temperature threshold is
reached or passed
TEMPOFF=XX –OK
Ctrl
THERMOSTAT?
Information message: Request for
temperature configuration
THERMOSTAT=YES,
(NO) ON=25
OFF=27
Ctrl
7.1 Thermostat
This feature can be attractive if you wish to ensure activating or deactivating
appliance when temperature threshold is reached.
Typical example is heating activation when temperature is below 20 ˚C and
deactivating when temperature is over 25 ˚C.
(THERMOSTAT=YES, TEMPON=20, TEMPOFF=25)
Other example is airconditioning activation over 28 ˚C and deactivation when
temperature is below 24 ˚C
(THERMOSTAT=YES, TEMPON=28, TEMPOFF=24)
7.2 Temperature calibration
Measured temperature is usually influenced by heating caused by IQsocket
electronics , so built-in thermometer provides usually little higher temperature
as real. For this reason is used temperature calibration constant which is
configured based on global experience to value 4. This calibration can be
changed individually for each monitored environment. Measured temperature is
decreased always by calibration this constant.
Command
Description
Response
Type
TEMPCAL=X
Changes calibration constant. 1
–9 values can be used.
TEMPCAL = X –OK
Conf
TEMPCAL?
Request for TEMPCAL config.
TEMPCAL = 4
Conf
8.Other commands
Command
Description
Response
Type
ERRORREPLY=YES
Activates sending of information SMS
for each received SMS command,
which was not executed due to any
error.
ERRORREPLY =YES –OK
Conf

2009 NETCONS, s.r.o.
Page 11 of 16
ERRORREPLY=NO
Deactivates sending of information
SMS for each received SMS command,
which was not executed due to any
error.
ERRORREPLY =NO –OK
Conf
ERRORREPLY?
Information message: Request for
ERRORREPLY settings
ERRORREPLY =(NO),YES
Conf
OUTPUT=REMEMBER
Output power socket remember it’s
status after it’s unplugged or central
power is interrupted
OUTPUT=REMEMBER –
OK
Conf
OUTPUT=ON
Output power and microrelay will be
turned on after it’s unplugged or
central power is interrupted
OUTPUT=ON –OK
Conf
OUTPUT=OFF
Output power and microrelay will be
turned off after it’s unplugged or
central power is interrupted
OUTPUT=OFF –OK
Conf
OUTPUT?
Information message: Request for
initial mode configuration of
output power socket and
microrelay
OUTPUT=(REM), ON, OFF
Conf
INPUT=ALARMHIGH
Detection mode for external detector.
In this case alarm is generated after
high voltage is detected.
INPUT=ALARMHIGH–OK
Conf
INPUT=ALARMLOW
Detection mode for external detector.
In this case alarm is generated after
low voltage is detected.
INPUT=ALARMLOW –OK
Conf
INPUT?
Information message: Request for
input mode configuration
INPUT=DISCONNECTED,
(CONNECTED)
Conf
VERSION
Request for firmware version
Ver. 1.0.6 (c) 2008
Ctrl
RINGON
Back call is realized to the number
of the incoming SMS. Usefull
feature when using prepaid cards
to keep card active.
/no confirmation
Ctrl
If bad command is received, power socket replies with „message –ERROR!“
message
Capitals and small alphabets are not recognized in commands
SMS messages longer than 20 characters are automatically ignored
9. Alarms and microrelay
9.1 External detector alarms
External detectors can be used for various alarm detections, for example
motion, fire, gas, water, opened door/window detection and so on. Detectors
are connected over 3.5 mm jack. It is possible to use more different detectors
divide by jack divider, total current shouldn’t be more than 50mA. Only first
alarm within 60 seconds is indicated.
Command
Description
Response
Type
ALARMON
Activated is alarm detection by
external detectors.
AlarmOn = OK
Alarm –NO sensor
Ctrl
ALARMOFF
Deactivated is alarm detection by
external detectors.
AlarmOff = OK
Ctrl

2009 NETCONS, s.r.o.
Page 12 of 16
ALARM+420123456789
When alarm is activated, power
socket is making a call to
preconfigured number. When external
detector is unplugged, alarm is
activated too and is repeated each 60
seconds.
Alarm+421903801
254 –OK
Alarm –NO sensor
Alarm –NO
number!
Ctrl
ALARMOUTPUT=10
Activates switched contact/microrelay
on alarm. Can be used for siren or
anything else.
ALARMOUTPUT=10
–OK
Conf
ALARMOUTPUT?
Request for ALARMOUTPUT
configuration
ALARMOUTPUT= 15
seconds
Conf
9.2 Temperature alarms
Built-in thermometer can be used to generate temperature alarms after critical
temperature thresholds are reached. IQsocket uses low and high temperature
thresholds which are configured by TEMPON=MAX and TEMPOFF=MIN
commands. Temperature alarm monitoring is activated 10 minutes after
IQsocked is powered on.
Command
Description
Response
Type
TEMPALARM=NO
Temperature alarms are disabled
TEMPALARM=NO –
OK
Ctrl
TEMPALARM=MAX
In case of maximal temperature
threshold is reached - SMS is sent
TEMPALARM=MAX
–OK
Ctrl
TEMPALARM=MIN
In case of minimal temperature
threshold is reached - SMS is sent
TEMPALARM=MIN –
OK
Ctrl
TEMPALARM=MIX
In case of mini or maximal temperature
threshold is reached - SMS is sent
TEMPALARM=MIX –
OK
Ctrl
TEMPALARM?
Request for temperature configuration
TEMPALARM=(NO),
MAX,MIN,MIX
Ctrl
External detectors
9.3 Generated alerts
There are more ways how to inform you about detected alarm. You can be
alerted by SMS or by phone call on active alarm. Or you can be informed by
SMS on each change of logical INPUT.
Command
Description
Response
Type
ALERT=RINGON
Phone call is established to predefined
number in case of new alarm
ALERT=RINGON -
OK
Conf
ALERT=SMS
SMS is sent to predefined number in
case of new alarm
ALERT=SMS –OK
Conf
ALERT=SMSCHANGE
SMS is sent on each logic value change
to predefined number in case of new
alarm
ALERT=SMSCHANG
E - OK
Conf
ALERT?
Request for alert configuration
ALERT=(RINGON),
SMS, SMSCHANGE
Conf

2009 NETCONS, s.r.o.
Page 13 of 16
When option RINGON is used preconfigured number (by ALARM command) is
called within 30 seconds. No new alert is generated within 60 seconds after
alarm was detected. This option is ideal for PIR sensors which cause change of
logical 0 to logical 1 value. On the other way - it is not suitable for door sensors
which stay in switched logical 1 value. In this case alarm event is repeated until
ALARMOFF command is sent.
9.4 Alarm logs
This command helps to watch over alarm history. Device keep last 5 events in
internal memory sorted by time.
Command
Description
Response
Type
SHOWALARM
Used to list alarm history log
yy/mm/dd:hh:ss
Ctrl
This feature can be also used for example to monitor people activity in room.
In case of active ALARMON you can also switch to ALARMOFF by manual button
on device. After this manual command you can use manual button under
normal operation (not switching back to ALARMON).
More detectors can be used in parallel using by Jack splitter. Detectors
are not recognized individually, max. current generated by detectors is 50mA.
9.5 External detectors –scheme
GND
Alarm
+12V/50mA
Splitter
Connectors are not supplied with product
9.6 Microrelay –scheme
10. Date and time
Date and time are used for alarm logs and scheduling. It can be configured
manually or automatically by each incoming SMS.

2009 NETCONS, s.r.o.
Page 14 of 16
Command
Description
Response
Type
DATE
Automatic date/time configuration from
SMS is activated
DATE yy/mm/dd,
hh:mm:ss+zz –
OK
Conf
DATE=yy/mm/dd,hh:
mm:ss+zz
Used for manual date/time configuration
DATE=yy/mm/dd,
hh:mm:ss+zz –
OK
Conf
DATE?
Resuest for actual date/time
DATE yy/mm/dd,
hh:mm:ss+zz
Conf
NOTE: zz is GMT timezone
11. Scheduler
Scheduler enables to control output power socket automatically based on pre-
scheduled date/time rules. Scheduler accept max. 8 rules.
Command
Description
Response
Type
SCHEDULER+hh:mm,da
y,action
Add new rule for specified time valid for
all days within a week
SCHEDULER+hh:
mm,*,ON –OK
Ctrl
SCHEDULER-hh:mm
Delete record for configured time
SCHEDULER-
hh:mm - OK
Ctrl
SCHEDULER?
Request for scheduler configuration
hh:mm,*,action
Ctrl
* = any day
1=Monday, 2=Tuesday, 3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday
Actions: ON=Turn On, OFF=Turn off, INF=status of IQsocket is sent (as by STATUS command)
AON=Alarm On, AOF=Alarm Off
Examples:
SCHEDULER+10:00,*,ON Every day at 10:00 is output power socket turned on
SCHEDULER+14:30,*,OFF Every day at 14:30 is output power socket turned off
SCHEDULER+01:00,1,AON Every Monday at 01:00 is activated alarm
SCHEDULER+02:00,2,AOF Every Tuesday at 02:00 is deactivated alarm
SCHEDULER+18:00,5,INF Every Friday at 18:00 is sent status info
12. Original settings
Each new device is preconfigured with factory default values. Device can be
anytime returned back to these default values during it’s lifecycle. This can be
realized by reset to factory default procedure.
12.1 Reset to factory default procedure
Reset button is available on the bottom cover near the SIM slot, details can be
found in first pages of this document.
Please push this reset button at least 5 seconds, then release. All LED
indicators should start blinking for next 10 seconds. Please press the button
again within these 10 seconds to confirm reset to factory default procedure.
After this step is your device in original factory configuration.

2009 NETCONS, s.r.o.
Page 15 of 16
12.2. Default factory settings
Parameter
Value/Status
Parameter
Value/Status
Output power socket
OFF
SMSPIN
NOPIN
Mikrorelay/output2
OFF
OUTPUT
REMEMBER
INPUT
ALARMHIGH
RESTARTTIME
10
ERRORREPLY
NO
RING
NOACTION
ALARMOUTPUT
10
SECNUMBER
NO
ALARM
OFF
SMSWWW
NO
TEMPCAL
4
SMSCONFIRM
YES
ALERT
RINGON
RINGCONFIRM
NO
DATE
AUTOMATIC
THERMOSTAT
NO
SCHEDULER
EMPTY
TEMPON
25
TEMPALARM
NO
TEMPOFF
20
13. Firmware upgrade
IQsocket firmware upgrades can be performed only by authorised trained
person or by authorised service center.
14. LED indicators
POWER
LIGHTS RED Input power is OK;
BLINKS RED 4 x WITHIN SECOND Alarm detection is active
LIGHTS GREEN Alarm is detected while detection is active
BLINKS GREEN 4 x WITHIN SECOND Alarm is detected, detection is not active
BLINKS RED 2 x PER SECOND SIM is not correctly inserted or missing
GSM
BLINKS GREEN, EACH 3 SECONDS Logged to GSM network
BLINKING GREEN EACH SECOND Not logged to GSM network yet, searching
LIGHTS GREEN 2 x PER SECOND SIM card have active PIN usage
RELAY
NOT ACTIVE Output power socket is OFF
LIGHTS YELLOW Output power socket is ON
BLINKS YELLOW Hardware error
POWER
Indication of input power
GSM
Indication of GSM login status
RELAY
Indication of output power status
BE CAREFULL! This step will erase all your IQsocket configuration.

2009 NETCONS, s.r.o.
Page 16 of 16
15. Technical specification
Model
IQSW-GSM-F, IQSW-GSM-E
Input power socket
230V / 50Hz
Output power socket
230V , CEE 7/4 German "Schuko" earthed
230V, CEE 7/4 French type
Data interfaces
GSM SIM socket
Switching
Output 1: Relay, 230V/16A (2s), 10 A long-term
Output 2 : microrelay, max. 50V / 0,5 A
Management
SMS configuration, SMS parameters monitoring
Indicators
POWER: two-color LED
GSM: green LED
RELAY: yellow LED
Detectors
Built-in thermometer
Alarm input for external detectors (motion, gas, water, fire,
door/Windows and more.)
GSM
900 / 1800 /1900 MHz
SIM card Plug-in 3V
Integrated tape microstrip antenna
GPRS
Not supported
Software features
Appliance control over SMS, by call or manually
Remote power turnon/turnoff of 230V appliance
Remote power turnon/turnoff of output circuit up to 48V
Remote power turnoff for specified time
Remote appliance restart
Remote appliance status switch (turnon to turnoff or back)
Remote temperature measuring
Thermometer, Alarm detection, Scheduler
Power
230V , CEE 7/7
Weight Netto / Brutto
350g / 420g
Operating temperature
-10 to +50 ˚C
16. Care and security recommendations
Product was designed for indoor use. Don’t use it in wet or chemically
aggressive environment. It is also not designed for industry operation with
aggressive environmental conditions. Don’t let the product to get in shaking or
fall downs, otherwise it can be damaged. Please check, if mobile phones can be
used in the area before use. In not, don’t put product into operation, it can
have negative influence to other electronic systems.
Improper use, disassembling or product modification causes warranty
loss. Product doesn’t guarantee safe power source interruption, only functional
switching is realized.
Other manuals for IQSW-GSM
1