iQtronic IQTD-GS440 User manual

IQTD-GS440
User Guide
GSM gateway controlled by SMS,
making a call, IVR self service and
Bluetooth terminal, with universal
inputs, M M and PLC.

1 Product features ............................................................................ 3
2. Wiring IQTD-GS440 ......................................................................... 5
3. Po er supply iring........................................................................ 6
3.1 AC power wiring.............................................................................6
3. DC power wiring.............................................................................6
4. Instalation....................................................................................... 6
4.1 Inserting SIM Card .........................................................................7
4. Powering IQTD-GS440 On ...............................................................8
5. Explanatory Notes to Commands ..................................................... 9
6. Basic Control ................................................................................. 11
7. Advanced Settings.............................................................................
7.1 Control of PWM of outputs 3 and 4 based on temperature ................. 58
7. PLC control of outputs OUT1 – 4 based on intputs DIN 1-4 ................ 60
8 Control by IQcontrol Suite for WINDOWS ....................................... 63
8.1 IQControl subprogram................................................................... 64
8. Commands editor subprogram .......................................................70
8.3 Numbers Editor Subprogram .......................................................... 74
8.4 IVR Completor subprogram............................................................ 75
9. Control by IQcontrol Smart Application for OS Android ................. 81
9.1 Control by SMS ............................................................................8
9. Control by terminal via wireless Bluetooth connection........................ 83
10. Meaning of integrated button ...................................................... 85
11. Inserting SD card ........................................................................ 85
12. Factory default settings............................................................... 86
1 .1 Manual configuration of factory default values ................................ 86
1 . . Factory default settings .............................................................. 87
13. LED indicators ............................................................................. 88
13.1. Functional indication .................................................................. 88
13. . Error conditions......................................................................... 89
14. Error messages............................................................................ 89
15. Technical Specification ................................................................ 90
16. Instalation rules for dual radio device ......................................... 90
17. Features and connection of s itching elements .......................... 91
17.1 Lifetime for using AC voltage........................................................91
17. Lifetime for using DC voltage........................................................91
17.3 Load connection to the device output ............................................ 9
17.4 Connection by use of a contactor .................................................. 9
18. Input specification ...................................................................... 93
18.1 Analog input 1 and - ADH and ADL ......................................... 93
18. Digital inputs DIN1, DIN and DIN3............................................ 94
20. Installation of the backup battery ............................................... 94
20. Accessories .....................................................................................
21. Configuration of original English set of commands ..........................
22. Operation, maintenance and security safety recommendations .......
23. Warranty .........................................................................................

2021 IQtronic technologies Europe s.r.o.
Page 3 of 97
Ackno ledgements
Thank you that you have purchased this IQTD-GS440 produced by IQtronic
technologies Europe Ltd, the real manufacturer providing the unique and
unrivalled products. Our company has produced IQ socket products for already
10 years and has delivered them throughout the world. Our products always
offer you a lot more. But consider by yourself...
1Product features
IQTD-GS440 is a highly sophisticated device intended to control electrical
appliances connected to device’s outputs by sending SMS messages and
making calls to device’s SIM card number by means of a mobile phone. IQTD-
GS440 can be also controlled wirelessly via Bluetooth using IQcontrol software
terminal. An interactive voice self service (IVR) is another way to control your
device.
This product has also a universal input to connect external accessories: up to 8
temperature and humidity sensors. It incorporates almost 00 implemented
SMS commands.
The output of the device is two 230V AC switched power relay outputs with
the maximum current capacity of 16A – resistance load and t o DC
switched outputs with 5A/40V rating and PWM support.
Among others, the product has the following interesting functions:
•Turning electrical appliances on and off by SMS messages or by making a
call to device’s internal SIM card number.
•Automatical control: turning electrical appliances on and off at
predermined time by means of a scheduler or at a user-specific time.
•Sending automatically an alert on power failure and restore.
•Restarting appliances, such as servers.
•Monitoring the external input status: Two A/D inputs - monitoring
electric fences and AC/DC voltages with autodetect, digital inputs
DIN1, DIN for DC voltage, 1 digital input DIN3 for AC/DC voltage.
One universal bus for temperature and humidity sensors.
•Thermostat function.
•Alarm function: temperature alarm, humidity alarm, A/D, or change at
digital inputs, power failure, power restore.
•Alarm in case of a GSM signal jamming.
•Optional internal back up battery for operating without AC or DC power.

2021 IQtronic technologies Europe s.r.o.
Page 4 of 97
•Up to 1 alarm numbers, each of the numbers can be set for a different
event.
•Time scheduler function, up to 50 events with interval settings.
•Automatical logging of all events into the internal memory.
•Interactive voice self service that can be customized by a user.
•Configuration via Bluetooth with a professionally designed IQcontrol
software terminal with an intuitive usage.
•Two Administrators and up to one thousand users.
•Texts of commands and responses can be customized by user.
•Option to save and restore of the configuration, to download event log
file.
•User numbers can be uploaded from a text file.
•Upgradeable firmware.
•Possibility to change the rights of SMS commands.
•Supports control from Internet SMS gateways.
•Sending status of all inputs via GPRS (TCP) into cloud.
•Advanced integrated navigation HELP.
•Can be controled by means of ANDROID application.
•Connector for external antenna for areas with poor GSM signal.
•Option to insert more commands in one SMS message (160 characters).
•Two independent actions can be set for incoming call.
•Possibility of logging every event with action on SD card
•Implemented M M for GET and SET (from XML file)
•Easy PLC (Programmable Logic controller) feature for setting outputs
according to inputs status.
•Two independent power supply inputs – AC and DC, capable to generate
alarm and usable with the PLC.
Upper terminal block with 30VAC input and power relay ouputs
Led indicators
SIM bay
SD card bay
SMA/f connector for external GSM
antenna
Lower terminal block with low
voltage
Push button for manual control

2021 IQtronic technologies Europe s.r.o.
Page 5 of 97
2. Wiring IQTD-GS440
OUT1 – switched output 1, 16A
OUT – switched output , 16A
L – phase (live) of mains connection
N – neutral wire of mains connection
Lower Terminal Block
1 – OUT3 switched output 3, DC voltage
max. 40V/5A with PWM.
– OUT4 switched output 4, DC voltage
max. 40V/5A with PWM.
3 – ADIN1 analog input ADH for
measuring voltage 0 – 30/50VAC, DC
with autodetect. Resolution of 0.1V, %.
4 – ADIN2 analog input ADL for
measuring voltage 0 - 5 VDC,
resolution of 0.1V, accuracy of %.
5 – DIN1 digital input 1, two stage, 0 – 30 VDC, S0, optocoupler
6 – DIN2 digital input , two stage, 0 – 30 VDC, S0, optocoupler
7 – DIN3 digital input 3, two stage, 0 – 30 VDC, S0, optocoupler
8 – DIN4 digital input 4, two stage, 0 – 30 VDC, S0, optocoupler
9 – Vsys Voltage ouput of system battery 4 VDC
max, 100mA fuse
10 – UIN univeral input for connecting up to 8 temperature and humidity
sensors.
11 – GND, Ground potencial of device.
1 – 13 Voltage input 12 -25 VDC/VAC, can be also used as an input for
external DC power supply. This power supply input is indenpendendt from, and
can be used together with the 30VAC input with possibility of power alarm
generation and and usability with the PLC.
Please note that all signals at the bottom terminal block are referenced to the
GND pin 11. Be careful when using any from provided voltage outputs, it is
not recommended to take a significant current from these pins.

2021 IQtronic technologies Europe s.r.o.
Page 6 of 97
WARNING!
Please respect maximum current rating of output1 and outpu2
- 16A for resistive load. Do not overload your IQTD- S440, as
this may damage or shorten life span of the internal switching
relays, which is not covered by warranty. It is recommended to
use external contactors in case the higher current is required
and/or capacitive/inductive load is used.
3. Po er supply iring
Installation shall be performed by certrified installer qualified for local
electric code
Your IQTD-GS440 is normally powered from 30V AC mains, but it is possible
to power it also from external 1 VDC power supply, e.g. a battery.
3.1 AC po er iring
3.2 DC po er iring
The allowed input voltage range is from 1 to 5VDC or VAC, current
consumption is about 40 mA in quiescent mode.
It can be used as back-up power supply to the AC mains voltage.
4.

2021 IQtronic technologies Europe s.r.o.
Page 7 of 97
Instalation
4.1 Inserting SIM Card
Insert the SIM card into the GSM slot
of your IQTD-GS440.
Size must be uSIM, oriented by contacts
facing top and with the notch away from
the device – slide it into the slot and push
it in to lock it inside, and release it out by
pushing it in one more time – Push Push
system.
WARNING!
PIN authorization should be turned off before the SIM card is
used in your IQTD- S440.
Authorization can be turned off by inserting the SIM card into your GSM phone
and disabling SIM PIN usage by using the appropriate command usually located
in ‘Settings’ phone menu. Now you can remove the SIM card from your phone
and insert it into your IQTD-GS440.
•Insert the SIM card with inactive PIN code authorization into the SIM
socket bay, accessible from the lower side of your IQTD-GS440 box.
•Push the card into the bay until you feel a click so card is locked inside.
•To remove the card from your IQTD-GS440, gently push the card
further into the bay until a click is felt, then card is unlocked and can
be pulled out.
Note…
It is highly recommended to delete all received SMS messages,
stored on the SIM card before using it in your IQTD- S440.

2021 IQtronic technologies Europe s.r.o.
Page 8 of 97
4.2 Po ering IQTD-GS440 On
Once the SIM card has been inserted, you can switch on 30VAC mains (or
external 1 VDC power supply) to power your IQTD-GS440 on. Verify device is
operating by observing status of the LEDs.
•Once AC power is connected, all eights LED indicators will blink shortly
and if everything is ok, the SYSTEM LED will turn to solid Red.
•In case of active PIN authorization on the SIM card, SYSTEM LED
starts blinking fast (approx. three times per second).
•LINK/ACT LED start to blink slowly (approx. every three seconds)
blue, once device was successfully logged into a GSM network. If the
LED blinks about every second, searching for a GSM network is in
progress.
•The Ouput1/ /3/4 LEDs indicate state of switched outputs.
Your IQTD-GS440 is now ready to use.
Please refer to chapter 13.2. Error conditions in case of any other
indications.

2015 IQtronic technologies Europe s.r.o.
5. Explanatory Notes to Commands
To control IQTD-GS440 in your language, please select the language version, as
shown in chapter 8.1 IQControl subprogram. The device has been factory pre-
configured for the English language.
Device contains built-in help system. If you send a message containing text HELP to
the number of SIM inserted in your device, you will get in response the control
commands, and in response to CONFIG you will get the configuration commands. If
you need to know the syntax and description of any command, use the SMS message
HELP=<command>, e.g. HELP=Restart and you will get description of a particular
command.
All commands are sent in SMS messages to the SIM card number inserted in device.
Commands have the following format:
pinCOMMAND - e.g. 1 34Turn off – if the PIN protection was activated (see chapter
0 7.Advanced Settings)
COMMAND - e.g. Turn off – with unconfigured PIN (factory default)
Command Number: It is the system specification for a command that is fixed, and
so it cannot be changed. You can only modify any text in your device; if you change
for instance TurnOn to MyCommand, and you would like to make further changes of
this command’s name, you need to know the number of the original command in
order to identify that command.
Text: A command in the form of a text string, in English as factory default language.
Function: It specifies the function of the particular command.
Response: The device will give a response if the command is entered in the correct
form.
License: Base license is included in the price for the product, Medium and Full – for
a license fee you will obtain a license key to be entered in your device by means of an
SMS message or via BT IQcontrol terminal software and then the commands and
functions of the particular license will be activated.
Access Rights: Admin, this command can be only used by the pre-configured
Administrator; in case the Administrator has not been pre-configured, any number,
i.e. anyone, can control and configure the device and is then considered to be the
Administrator.
User - this command can be also used by users from the user list -
up to 1000 numbers.
Command Nr. 01
Text TurnOn
Function It turns on the output power socket.
Response TurnedOn
Access Rights User/Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 10 of 97
Describtion of control and configuration of IQTD-GS440 is divided into three parts,
each suitable for a specific user group.
1. Basic part is suitable especially for those users who wish to use the basic functions
as quickly as possible. It is indicated by the green square located on the right side or
at the top of the page.
2. Advanced part contains advanced functions such as security, GPRS, time intervals,
alarms, etc. It is indicated by the yellow square on the right side and in the middle
part of the page.
3. Expert part is particularly appropriate for those users who wish to get the
maximum of the product. It presents control by the use of the smart application
IQcontrol for Android and IQcontrol Suite for Windows. Furthermore, it provides
information on the voice self service or how to create an own voice self service, how
to edit the text of commands and responses, transfer of the product settings, how to
save LOG evets into a file. Then it presents the Numbers Editor for security and saving
the set in the product, firmware upgrade, and others. It is indicated by the red square
on the right and in the middle part of the page.
Note…
Your device has built-in intelligent help system allowing faster control actions; if you
send an incorrect command, your device will offer similar commands to you. You may also
send more than one command consecutively in a single SMS. Your device will then reply by
individual SMS messages. Please see an example from the terminal of I control Suite for
Windows when sending the character 'a' and two commands TurnedOn and Status - separated
by character #.

2021 IQtronic technologies Europe s.r.o.
6.Basic Control
If you send a message containing text "HELP" to the telephone number of SIM in your
device, the following control commands will be displayed:
These commands are displayed automatically in the welcome note after you have
logged in by the IQcontrol software terminal via Bluetooth.
Command Nr. 01
Text TurnOn
Function It turns on the all outputs OUT1 and OUT .
Response TurnedOn
Access Rights User/Admin License Base
Command Nr. 0
Text TurnOn1
Function It turns on the output OUT1.
Response TurnedOn1
Access Rights User/Admin License Base
Command Nr. 143
Text TurnOnTime 1
Function It turns on the output OUT1 only for a specified time in range of 1 to
880 minutes.
The text TurnONTime=10 turns on the output OUT for 10 minutes.
Response TurnedOn
Access Rights User/Admin License Base
Command Nr. 03
Text TurnOn2
Function It turns on the output OUT .
Response TurnedOn2
Access Rights User/Admin License Base
Command Nr. 1 4
Text TurnOnTime 2
Function It turns on the output OUT only for a specified time in range of 1 to
880 minutes.
The text TurnONTime=10, it turns on the output OUT for 10 minutes.
Response TurnedOn
Access Rights User/Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 1 of 97
Command Nr. 13
Text TurnOn3
Function It turns on the output OUT3.
Response TurnedOn
Access Rights User/Admin License Base
Command Nr. 144
Text TurnOnTime 3
Function It turns on the output OUT4 only for a specified time in range of 1to
880 minutes.
The text TurnONTime=10, it turns on the output OUT for 10 minutes.
Response TurnedOn
Access Rights User/Admin License Base
Příkaz číslo 135
Znění PWM3 PWM3
Funkce PWM3=x, where x is the pulse width in range 0 – 100% (0 –turned off
all the time, 100 -turned on all the time). Sets PWM modulation with
0kHz frequency on the OUT3 output.
PWM3=50 sets 50% PWM on OUT3
Odpověď TurnedPWM ZapnutoPWM
Práva User/Admin Licence Base
Command Nr. 136
Text TurnOn4
Function It turns on the output OUT4.
Response TurnedOn
Access Rights User/Admin License Base
Příkaz číslo 139
Znění PWM4 PWM4
Funkce PWM4=x, where x is the pulse width in range 0 – 100% (0 –turned off
all the time, 100 -turned on all the time). Sets PWM modulation with
0kHz frequency on the OUT4 output.
PWM4=50 sets 50% PWM on OUT4
Odpověď TurnedPWM ZapnutoPWM
Práva User/Admin Licence Base
Command Nr. 04
Text TurnOff
Function It permanently turns off the output socket.
Response TurnedOff
Access Rights User/Admin License Base

2021 IQtronic technologies Europe s.r.o.
Command Nr. 05
Text TurnOff1
Function It permanently turns off the output OUT1.
Response TurnedOff
Access Rights User/Admin License Base
Command Nr. 06
Text TurnOff2
Function It permanently turns off the output OUT .
Response TurnedOff
Access Rights User/Admin License Base
Command Nr. 133
Text TurnOff3
Function It permanently turns off the output OUT3.
Response TurnedOff
Access Rights User/Admin License Base
Command Nr. 137
Text TurnOff4
Function It permanently turns off the output OUT4.
Response TurnedOff
Access Rights User/Admin License Base
Command Nr. 07
Text Restart
Function It changes the status of both outputs for a user specified time
RestartTime.
Response Restarted
Access Rights User/Admin License Base
Command Nr. 08
Text Restart1
Function It changes the status of the output OUT1 for a user specified time
RestartTime1.
Response Restarted
Access Rights User/Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 14 of 97
Command Nr. 09
Text Restart2
Function It changes the status of the output OUT for a user specified time
RestartTime2.
Response Restarted
Access Rights User/Admin License Base
Command Nr. 134
Text Restart3
Function It changes the status of the output OUT3 for a user specified time
RestartTime3.
Response Restarted
Access Rights User/Admin License Base
Command Nr. 138
Text Restart4
Function It changes the status of the output OUT4 for a user specified time
RestartTime4.
Response Restarted
Access Rights User/Admin License Base
Command Nr. 177
Text OUTLock1
Function It locks any changes (manual, scheduler, PLC) at output OUT1.
Response OUTPUT locked!
Access Rights Admin License Base
Command Nr. 178
Text OUTUnLock1
Function It unlocks (manual, scheduler, PLC) output OUT1 for any changes.
Response Ouptut unlocked
Access Rights Admin License Base
Command Nr. 179
Text OUTLock2
Function It locks any changes (manual, scheduler, PLC) at output OUT .
Response OUTPUT locked!
Access Rights Admin License Base
Command Nr. 180
Text OUTUnLock2
Function It unlocks (manual, scheduler, PLC) output OUT for any changes.
Response Ouptut unlocked
Access Rights Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 15 of 97
Command Nr. 181
Text OUTLock3
Function It locks any changes (manual, scheduler, PLC) at output OUT3.
Response OUTPUT locked!
Access Rights Admin License Base
Command Nr. 18
Text OUTUnLock3
Function It unlocks (manual, scheduler, PLC) output OUT3 for any changes.
Response Ouptut unlocked
Access Rights Admin License Base
Command Nr. 183
Text OUTLock4
Function It locks any changes (manual, scheduler, PLC) at output OUT4.
Response OUTPUT locked!
Access Rights Admin License Base
Command Nr. 184
Text OUTUnLock4
Function It unlocks (manual, scheduler, PLC) output OUT4 for any changes.
Response Ouptut unlocked
Access Rights Admin License Base
Command Nr.
10
Text Status
Function It displays a short SMS message about the status of the outputs and
inputs of this device.
Response Output1: TurnedOff Output : TurnedOff, Output3: Restarted
Output4: PWM, PWrStatus PowerAC, Signal:61% , Bcap: 100%,
Last pwrlost: 15/04/ 3,18:40:01
Access Rights User/Admin License Base
Command Nr. 97
Text LongStatus
Function It displays a detailed SMS message about the status of the outputs and
inputs of this device.
Response Output1: TurnedOff Output : TurnedOff, Output3: Restarted

2021 IQtronic technologies Europe s.r.o.
Page 16 of 97
Output4: PWM, BCap: 100% OnPower, DIN1: 0 DIN : 0 DIN3: 0
DIN4: 0 ADL: 0 ADH: 0 Pulses: 0 SDcard:No Signal:61% S1: N/A
S : N/A S3: N/A S4: N/A S5: N/A S6: N/A S7: N/A S8: N/A N/A
Gauge: 0d 0h 0m 0s Batstat: Charged Time: 15/04/ 3,19:47:30
Last pwrlost: 15/04/ 3,18:40:01 OP: EUROTEL PRAHA
Access Rights User/Admin License Base
Command Nr. 98
Text SaveStatus
Function It saves the status of your device at a given time in the internal device
LOG that can be displayed. Internally and on SDcard (Full license)
Response SaveStatus – OK
Access Rights User/Admin License Base
Command Nr. 11
Text RingOn
Function It makes a call back for time specified by RingOnTime
Response No response
Access Rights User/Admin License Base
Command Nr. 1
Text Help
Function It displays all control commands – In case of the USER access rights,
the command HELP will give a description of the command syntax.
Response See description
Access Rights User/Admin License Base
Command Nr. 13
Text Config
Function It displays configuration commands – in case of ADMIN access rights
Config=50 will display commands starting from the 50th command,
since a list can contain more characters than a maximum of 4x160 (4
SMS messages), and then each undisplayed command is listed as a
character '.'
Response See description
Access Rights User/Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 17 of 97
Command Nr. 0
Text AdminList
Function It displays the Administrator number.
Response AdminList= 20123 5678
Access Rights User/Admin License Base
Command Nr. 131
Text AdminList2
Function It displays the second Administrator number.
Response AdminList2= 20123 5678
Access Rights User/Admin License Base
Command Nr. 4
Text SendGPRS
Function It sends device status including state of inputs and outputs via GPRS in
HTTP GET format, for example if api.thingspeak.com is configured, it
will read XML file and will set outputs per values in it.
It is required from the user to have configured GPRS parameters and
have GPRS Internet service on the SIM card.
Response SendGPRS – OK
Access Rights User/Admin License Full
Note…
You can assign the AD IN/USER Access Rights
for each command in the COMMANDS
EDITOR of the I control SUITE. This guide presents only commands as used in factory
default settings.
Command Nr. 88
Text Version
Function It displays the internal software version.
Response Ver. 1.0.0.
Access Rights User/Admin License Base

2015 IQtronic technologies Europe s.r.o.
7.Advanced Settings
If you send a message containing text "CONFIG" to the telephone number of your
device, the configuration commands will be displayed.
These commands can be used only by the specified ADMIN, if it is defined. In factory
default settings any user is considered to be ADMIN. You can set the User or ADMIN
access rights in the Commands Editor of the IQcontrol Suite software.
Since the list of configuration commands can be longer than maximum allowed size of
4 SMS messages (4x160 characters), each undisplayed command is listed as a
character '.' If you wish to see the full list, for example to display commands starting
from the 50
th
command, you need to use the suffix "=50".
If you send any configuration command correctly, you will get in response
confirmation in the form of the suffix "-OK". You will get the current settings for
parameters of any command when you add the character '?' following the particular
command. As an illustration, in order to know the settings for the Output command,
you will send a message Output? and your device will send to you the settings
Output=(Remeber),On,Off, where the parameter in parentheses is currently
configured. If you wish to change the active parameter, select the particular
parameter as follows: Output=On .
Illustration of using the Config command:
RestartTime,RingactionAdmin,RingactionUser,NCactionAdmin,NCactionUser,AddAdmin,AddUser,DelUser,DelAllUsers,UserList,Use
rAList,RingTimes,RingOnTime,SMSPerDay,Output,AdminPINSet,AdminPIN,UserPINSet,UserPIN,BTPIN,PINIVR,ScheduleAdd,Sche
duleDel,ScheduleDeLAll,SchedulerLIST,SchedulerOptions,DeviceName,TempUnit,Counter,DelCounter,PwrFailTime,TriggerTime1,
TriggerTime2,TriggerTime3,Voltalarm,VLevelMin,VLevelMax,PulseAlarm,MinPulses,MaxPulses,TAlarm1,TAlarm2,TAlarm3,BatCap
Level,TempAlarm,PwrAlarm,AddAlarmNumber,DelAlarmNumber,DelAllAlarmNum,ListAlarmNum,Alarmqueue,StopAllAlarms,Jamm
Alarm,Tp1Max,Tp1Min,Tp2Max,Tp2Min,Tp3Max,Tp3Min,Tp4Max,......................
Illustration of using the Config=50 command:
Alarmqueue,StopAllAlarms,JammAlarm,Tp1Max,Tp1Min,Tp2Max,Tp2Min,Tp3Max,Tp3Min,Tp4Max,Tp4Min,Tp5Max,Tp5Min,Tp6M
ax,Tp6Min,Tp7Max,Tp7Min,Tp8Max,Tp8Min,TControlMax1,TControlMin1,OutputControl,Version,PinLimitsIVR,PinLimitsBT,UserTy
peIVR,AllLogs,SystemLog,ControlLog,ConfigLog,EraseSensors,LongStatus,SaveStatus,Default,GPRS,GPRSAPN,GPRShost,GPRSpo
rt,LEDoption,CntDiv1,CntDiv2,CntDiv3,NextTime1,NextTime2,NextTime3,SeparApply,Separators,Bluetooth,License,IMEI,IVRSou
ndDelay,TurnOnTime2,HoursCounter,RingActionBlock,Reboot.
Command Nr. 14
Text RestartTime1
Function It sets the restart time for output OUT1 in seconds,
allowed range is 1 up to 3600.
Settings with '?' RestartTime1=30
Settings Change RestartTime1=10
Access Rights Admin License
Base
Command Nr. 153
Text RestartTime2
Function It sets the restart time for output OUT in seconds,
allowed range is 1 up to 3600.
Settings with '?' RestartTime2=30
Settings Change RestartTime2=10
Access Rights Admin License
Base

2021 IQtronic technologies Europe s.r.o.
Page 19 of 97
Command Nr. 154
Text RestartTime3
Function It sets the restart time for output OUT3 in seconds,
allowed range is 1 up to 3600.
Settings with '?' RestartTime3=30
Settings Change RestartTime3=10
Access Rights Admin License
Base
Command Nr. 155
Text RestartTime4
Function It sets the restart time for output OUT4 in seconds,
allowed range is 1 up to 3600.
Settings with '?' RestartTime =30
Settings Change RestartTime4=10
Access Rights Admin License
Base
Command Nr. 15
Text RingActionAdmin
Function Action after confirmed incoming call to the Admin number if
the number is set. If not, any number is considered to be
Admin.
Settings with '?' (NoAction),HangUP,Restart,Reswitch,
Restart1,Reswitch1, Restart2,Reswitch2,
Restart3,Reswitch3, Restart ,Reswitch ,IVR
RingActionAdmin=No
Action
The device gives no response to an incoming call, however,
the information on time of the call and the calling number,
including the number of rings, are saved in the internal LOG.
RingActionAdmin=Ha
ngUp
The device hangs up and makes no action to an incoming call
longer than one ring*. A record with time of the call and the
calling number, including the number of rings, will be saved
in the internal LOG.
Command Nr. 1 5
Text Reboot
Function It executes the restart of the device itself, BT connection will be
terminated.
Response Reboot – OK
Access Rights Admin License Base

2021 IQtronic technologies Europe s.r.o.
Page 0 of 97
RingActionAdmin=Re
start
The device hangs up the incoming call* and performs the
RESTART of both outputs. Restart1 – OUT1 only. Restart2 -
OUT only. A record with time of the call and the calling
number, including the number of rings and the performed
action, will be saved in the internal LOG.
RingActionAdmin=Re
switch
The device hangs up the incoming call* and makes a
permanent change of the status (TurnOff/TurnOn,
TurnOn/TurnOff) of both outputst. Res itch1 –
OUT1 only.
Res itch2– OUT only. A record with time of the call and
the calling number, including the number of rings and the
performed action, will be saved in the internal LOG.
RingActionAdmin=IV
R
The device answers the incoming call* and activates the
voice selfservice. A record with time of the call and the
calling number, including the number of rings and the
performed action, will be saved in the internal LOG. It is
required that a voice file is recorded and the MEDIUM license
is activated.
Access Rights Admin License Base
Command Nr. 16
Text RingActionUser
Function Action for confirmed incoming call to a user number if the
number is set. Otherwise, it will be ignored.
Settings with '?' (NoAction),HangUP,Restart,Reswitch,
Restart1,Reswitch1, Restart2,Reswitch2,
Restart3,Reswitch3, Restart ,Reswitch ,IVR
RingActionUser=NoAc
tion
The device gives no response to an incoming call, however,
the information on time of the call and the calling number,
including the number of rings, are saved in the internal LOG.
RingActionUser=Hang
Up
The device hangs up and makes no action to an incoming call
longer than one ring*. A record with time of the call and the
calling number, including the number of rings, will be saved
in the internal LOG.
RingActionUser=Rest
art
The device hangs up the incoming call* and performs the
RESTART of both outputs socket. Restart1 – OUT1 only.
Restart2 - OUT only. A record with time of the call and the
calling number, including the number of rings and the
performed action, will be saved in the internal LOG.
RingActionAdmin=Re
switch
The device hangs up the incoming call* and makes a
permanent change of the status (TurnOff/TurnOn,
TurnOn/TurnOff) of both outputs. Res itch1– OUT1 only.
Res itch2 – OUT only. A record with time of the call and
the calling number, including the number of rings and the
performed action, will be saved in the internal LOG.
Table of contents
Popular Gateway manuals by other brands

Ariston
Ariston 3319089 Installation and user manual

Atop
Atop MB5404D-X Series Hardware installation guide

AddPac
AddPac VoiceFinder AP-MG3000N installation guide

OpenVox
OpenVox SWG20 4S Series user manual

Seneca
Seneca Z-KEY-MBUS installation manual

ZyXEL Communications
ZyXEL Communications P-660HNT1 user guide

Atlantis Land
Atlantis Land A07-VTG3306C Specification sheet

RTA
RTA 460ETCBMS-N700 Product user guide

ZyXEL Communications
ZyXEL Communications Prestige 314 PLUS user guide

B+B SmartWorx
B+B SmartWorx SmartSwarm 342 Quick start guides

LevelOne
LevelOne AMG-2100 Quick installation guide

Coaxmedia
Coaxmedia Series 6000 user guide