IRIS ID IrisAcces ICU7000-2 Installation instructions

ICU7000-2
CONTROLS UP TO
2 iCAMs
EASY
INSTALLATION
ICU7000-2
HARDWARE GUIDE
IDENTITY CONTROLLER
• Supports all iCAM7 series Camera Units
• iCAM4000 series Support Available
• Easy Installation
• Surface Mount Installation
VERSION 1.0
Packing List
Required Equipment (not included)
Hardware Components
• iCAM7 series Camera unit (sold separately)
• Windows Compatible computer (Refer to the iData
EAC Software Manual for details)
Network
• Ethernet Switch (an Ethernet Hub is not acceptable)
• Ethernet Wiring - CAT5e or better with RJ45 connectors
Software
• iData EAC Software version 3.11.x or above (Refer to the iData EAC Software Manual for details)
Power Source (optional)
• External power source - 12-24 VDC +/- 10% / Minimum 24W (12VDC @ 2AMPS)
(Measured at ICU7000-2 unit)
• Uninterruptible Power Supply (strongly recommended)
What’s in the Box
• ICU7000-2 - Identity Controller Unit
• Power Adapter
Input: 100-240VAC @ 1.0AMP 50/60Hz
Output: 12VDC - 2.5AMPS
• Power Cable (110 VDC)
• Grommet
• Keys (x2)
• Hardware Guide

2
Front View
Top View
Hardware Information
Cable Channel Knock-out
Cable Channel Knock-out
Case Lock
Power Light Indicator
Air Vent
Bottom View
Side View
Model Serial Number Label

3
Inside ICU7000-2
Installation Guidelines
Inside
Wiring Legend
Guide
Speaker
Inside the ICU7000-2
Cable Channel
Knock-out
RTC Battery
Power LED Indicator
Power Connection
Ethernet Connection
Tamper Switch
Input / Output
Connections (Channel 1)
Input / Output
Connections (Channel 2)
Factory Default Button
On/Off Switch
• The ICU7000-2 should be installed in a location that will discourage tampering with the
unit, but is easily accessible for maintenance (such as a locked room, utility closet, or other
secure locations), preferably within the restricted area.
• This installation location requires power and a network communication to the IrisServer
and iCAM7 series unit(s).
If used with an access control panel, the ICU can reside close to the access panel.
• It is suggested that the ICU be on the same physical network switch as the iCAM(s) which
it controls. This is to maintain communication between the ICU and the iCAM so that the
iCAM can remain operational.
• All system components including the Ethernet network should be powered through an
Uninterruptible Power Supply (UPS) whenever possible. The UPS should provide power line
filtering as well as power back-up operation.
• The ICU7000-2 is designed for surface mounting only.
• Each IrisAccess® system component on the Ethernet network system must have a unique
assigned IP Address.

4
NOTE
General Wiring Requirements
Ethernet network wiring to connect with the network switch for communication.
For systems consisting of only the ICU and an iCAM, an Ethernet cross-over cable
may be used.
The ICU7000-2 unit requires at least the following wires:
IMPORTANT: IT IS RECOMMENDED THAT THE IRISACCESS SYSTEM BE PLACED ON A PRIVATE NETWORK
SEPARATE FROM GENERAL CORPORATE OR PUBLIC ACCESS. SYSTEM PERFORMANCE AND STABILITY MAY BE
AFFECTED DEPENDING ON AMOUNT OF GENERAL NETWORK TRAFFIC.
IMPORTANT: IT IS RECOMMENDED TO SUPPLY THE CORRECT AMOUNT OF POWER TO THIS UNIT. AN OVER OR
UNDER VOLTAGE APPLIED TO THIS PRODUCT MAY CAUSE PERMANENT DAMAGE AND VOID THE WARRANTY.
Installation
Mounting
1. Using the key(s) provided, unlock the enclosure.
2. Determine the point of entry into the enclosure for each cable. Remove the appropriate
2.8cm (1.1”) knockouts or if a knockout is not available at the desired location, drill holes
using a hole punch commonly used for
penetrating steel enclosures. Protect internal
electronics from metal filings.
3. Install the supplied wire grommet or another
connector to protect the wires.
4. Hold the enclosure in the desired location on
the mounting surface using it as a template;
mark the location of installation holes. There
are two types of screw holes, the diameter of
one type is 10m (0.39 inch) and the other
type is 5mm (0.20 inch).
5. Drill or punch holes in the mounting surface on
the marks.
6. Insert the cables into the enclosure.
16
(0.62”)
245
(9.6”)
72
(2.8”)
76
(3”)
220 (8.7”)
89
(3.5”)
65
(2.6”)
65
(2.6”)
NOTE
Power Adapter: The included power adapter can be used as the power source for the ICU. Be
sure to observe the polarity of the adapter wires to the power screw terminals on the ICU main
board. The wires of the adapter should not be extended. If the power source is beyond the
length of the power adapter then an external power source and wiring should be used.
External Power and Wiring: For installation when the included power adapter cannot be used
then it is recommended to use an external power supply and wiring.
• Power Supply: 12-24VDC +/- 10% - Minimum 24 Watts (24VDC @ 1AMP).
• Power Wiring: The recommended wire gauge for the ICU power is 18AWG (1.0 mm) wire.
Use of a stable power supply and proper gauge wire is required. The wire length voltage
drop must be accounted for in order to maintain the correct power at the ICU7000-2 unit. For wire
lengths over 30 feet (9 meters) or if thinner gauge wire is being used (more than 18AWG) then it is
required that a 24VDC power supply be used to overcome the wire length voltage drop. A 24VDC
supply with 18AWG (1.0 mm) wire will allow for a distance of up to 200 feet (61 meters).
OR

NOTE The ICU7000-2 is designed for surface mounting only.
7. Mount the enclosure on the wall using appropriate hardware.
5
IMPORTANT: A PROTECTIVE BATTERY TAB IS INCLUDED WITH THE RTC BATTERY. PLEASE REMOVE TAB TO
ENSURE PROPER FUNCTIONALITY.
NOTE
The maximum wire length of an Ethernet CAT5 wire is 100 meters (328 feet)
between the ICU and a network switch or computer.
NOTE Wiegand output is available from either the ICU7000-2 or an iCAM7 series camera unit.
Power Connection
• The included power adapter is auto switching from 110VAC~240VAC 50/60Hz and
includes an IEC60320 C13 to NEMA 5 mains power cable.
• If the local AC power outlets are not the NEMA 5 “US” type, then a local type power cable
with a C13 power connection must be purchased and used for installation.
Ethernet Connection
• An Ethernet network connection is required between the ICU and the IrisServer computer
when performing a New Installation, Upgrade, or Configuration of the ICU software. This
Ethernet connection should remain at least until the ICU configuration is completed.
• For direct connection between the ICU7000-2 and iCAM7 series camera unit, an Ethernet
cross-over cable can be used. In an installation (after configuration) that requires system
monitoring, user enrollment, and user modification; a constant Ethernet connection from
the ICU to the network containing the IrisServer and iCAMs is required. The ICUs Ethernet
connection is located on the right section of the ICU main board.
Ethernet Connection
CAT5/RJ45

External GPIO
A
Wire Connection Details
6
A B C D
F
E
A B C D E
GPIO Specifications:
• For output, the GPIO can provide 5VDC @ 20mA.
• For Input, the GPIO is selectable between active High & active Low.
• Assignment of GPIO is handled through Software
External GPIO
GPIO1
GND
GPIO2
GND
GPIO3
GND
GPIO4
GND

7
BRS232 Output
RS232
Output
To RS232 port
of computer
or access system
TXD
RXD
GND
RS232 serial communication port for connection with an access panel or to other computer
equipment. When configured, the Card ID associated with the user is output from the
RS232 output port upon a successful identification.
12VDC
(Max 0.3A)
12VDC
(Max 0.3A)
12VDC
(Max 0.3A)
TXD
RXD
GND
RS485 Output
RS485
Output
To RS485 port
of computer
or access system
TX/RX+
TX/RX-
RS485 serial communication port for connection with an access panel or to other computer
equipment. When configured, the Card ID associated with the user is output from the
RS485 output port upon a successful identification.
TX/RX+
TX/RX-
GND
RS422 Output
RS422
Output
To RS422port
of computer
or access system
TX+
TX-
RX+
RX-
RS422 serial communication port for connection with an access panel or to other computer
equipment. When configured, the Card ID associated with the user is output from the
RS422 output port upon a successful identification.
TX+
TX-
RX+
RX-
GND

IMPORTANT: ONLY KNOWLEDGEABLE PROFESSIONAL INSTALLERS SHOULD BE USED TO INSTALL ALL
ELECTRONIC ENTRY/EXIT LOCKING DEVICES. DIRECT CONNECTION OF ELECTRONIC ENTRY/EXIT LOCKING
DEVICES SHOULDN’T BE MADE FROM THE RELAY OUTPUTS ON THE ICAM. IT IS THE RESPONSIBILITY OF THE
INSTALLER TO ASSURE THAT THE INSTALLATION IS PERFORMED IN ACCORDANCE WITH ALL COUNTRY/STATE/
LOCAL FIRE AND SAFETY REGULATIONS AND THAT ANY 3RD PARTY PRODUCTS USED WILL NOT CREATE A
HAZARD.
8
CRelay Output
Relay Output
Two independent dry contact relays. The purpose and the duration of the relays are defined
by the controlling software. Typically, Relay_1 (NC_1, COM_1, NO_1) is triggered upon user
acceptance (access granted). The diagram shows Relay_1 connected to indicators which
changes from Red to Green for an accepted user. Relay_2 (NC_2, COM_2, NO_2) is typically
used to indicate iCAM tamper. In this diagram the relay is activated when the iCAM tamper
switch is triggered. The maximum electrical rating for the relay is 3A at 24VDC.
RED
LIGHT
POWER
SUPPLY
ALARM
SYSTEM
24 HOUR
ZONE
GREEN
NC_1
COM_1
NO_1
NC_2
COM_2
NO_2
Wiegand Output
Wiegand Specifications:
• Wiegand output uses 3 wire interface (Data0, Data1, and Ground),
• Maximum wire length from iCAM to Access Control Panel is 500feet (152m).
D
ACCESS
CONTROL
PANEL
GROUND
DATA_1
DATA_0
Wiegand Output Card Reader
Interface
The Wiegand Output from the ICU7000-2 unit can be used with 3rd party devices capable
of receiving Wiegand data. This Wiegand output emulates a typical Access Control Card
Reader. Configuration of this output is provided through software. See the associated
image for general wiring of Wiegand Output to an Access Control Panel.
NC
DATA_0
DATA_1
GND

9
EWiegand Input
Wiegand Intput
12VDC
DATA_0
DATA_1
GROUND
External
Prox Card
Reader
Wiegand input is available on the iCAM for connection from 3rd party proximity card readers.
This connection can provide 12VDC and a maximum 300mA current to a proximity card reader.
12VDC
(Max 0.3A)
DATA_0
DATA_1
GND
External Speaker Out
F
To amplified speaker
Left signal
Ground
Right signal 3.5mm
Allows for connection of an external amplified speaker. This port provides mono or stereo
(single channel) audio of voice prompts and other unit sounds. Both the internal and external
speakers can operate concurrently.
To amplified speaker
Mono
Stereo
Signal
Ground
3.5mm

ICU Configuration
The ICU7000-2 contains a configuration interface called the ICU7000-2 Configuration. This
configuration interface allows the installer to setup the ICU’s IP Address, IrisServer connection,
and iCAM connection, and other configuration options.
From a PC with an internet browser connected to the network (that the ICU7000-2 unit is
connected to), type the IP address of the ICU7000-2. For example, if the IP address of an ICU7000-2
is 192.168.5.200 (default IP), you would access the configuration web interface by typing
http://192.168.5.200 from an internet browser.
To login, the User ID required when prompted is ICU7000. The Password is iris7000.
The system is case sensitive when entering in your login credentials.
Once you have connected to the iCAM Configuration Interface - settings, information, and
options become available to further configure your system. Additional documentation for
setup and configuration can be found at:
http://irisid.com/productdocumentation
How to access the ICU7000-2 Configuration interface
NOTE
The IP address of the ICU7000-2 can be audibly announced by pressing the Factory Default
button twice consecutively (located on the ICU main board).
IMPORTANT: IF THE BUTTON IS HELD DOWN CONTINUOUSLY FOR 3 OR MORE SECONDS, THE ICU7000-2 IP
ADDRESS WILL BE RESET TO THE FACTORY DEFAULT IP (192.168.5.200).
10
Restoring The Unit to Factory Default
The Factory Default Button can be used to restore the settings of
an ICU7000-2 to factory default. This button is located inside of
the unit next to the power switch (see image), and can be used
in three different ways:
Factory Default Button
Reset IP Address and Login Credentials • Unit Power is ON
• Press and Hold the Factory Default Button for more than
3 seconds.
• Unit will beep when the default process has started.
• The ICU IP Address will be reset to 192.168.5.200,
The Username to ICU7000, and the password to iris7000.
Factory Default Button Function Procedure

11
Memo
Serial Number:
ICU7000-2 Unit IP Address:
IrisServer IP Address:
User Name:
Password:
Channel 1 - iCAM IP Address:
Channel 1 - Security ID:
Channel 2 - iCAM IP Address:
Channel 2 - Security ID:
Note:
Reset all settings and reload software • Power Unit OFF
• Press and Hold the Factory Default Button (FDB)
• While still holding the FDB, Turn ON the unit power
• Keep the FDB held in for at least 10 seconds.
• Stop holding the FDB
• Do not turn off the power to the unit or remove the network
connection for at least 10 minutes (the unit will reboot several
times on its own during the software reload process).
• When complete the ICU will have reloaded the software and
reset IP Addresses and log-in creditenials to the defaults.
IP Address Announcing • Unit power is ON
• Press the Factory Default Button twice
• The unit will announce its IP Address from the speaker

General Information
Technical Support
8.66” x 9.65” x 2.0” (220mm x 245mm x 51mm)Dimension (W x H x D)
3.0lbs (1.4kg)Weight
12-24VDC, 2.0 Amps @ 12VDC / 24WPower Input / Consumption
External Green LED for Power IndicationIndication
32°F ~ 122°F (0°C ~ 50°C)Operating Temperature
-4°F ~ 203°F (-20°C ~ 95°C)Storage Temperature
0 ~ 95% Non-condensingHumidity
Ethernet (LAN, WAN)Communications
2 Remote Channel (Wiegand In/Out, Dry Contact Relay x 2, Programmable
GPIO x 4, RS422) x 2
Inputs / Outputs
CE, FCC, KCC, UL294Certifications
Iris ID Systems, Inc.
www.irisid.com
7 Clarke Drive, Cranbury, NJ 08512, USA
Tel. 609-819-IRIS(4747) Fax. 609-819-4736
©2015 Iris ID, Inc. All rights reserved. Design and specification subject to change without notice. Printed in Korea
Additional information and technical assistance is available on the Iris ID support web site
at www.irisid.com/supportservices