Phase 1 : In the absence of movement, the luminaire will hold its
maximum intensity for a selectable duration of 5s / 30s / 1min /
3min / 5min / 10min / 20min / 30min. (hold period)
Phase 0 : As long as a person is detected by the sensor, the
luminaire is at its maximum intensity.
Adjustable lighting level with « Power % »
Phase 2 : If no movement is detected during the hold period, the
luminaire will dim to an adjustable intensity of 10% / 20% / 30% /
50% (stand-by period).
The reduced light level will be maintained for a selectable duration
of 0s / 10s / 30s / 1min / 5min / 10min / 30min / 60min / - -
before going off.
Example:
By adjusting the stand-by period to 0s, the luminaire will turn off directly
after the hold period without going through a reduction in lighting.
By adjusting the stand-by period to - -, the light will keep its intensity
reduced indefinitely without ever turning off in the absence of movement.
Principle of operation
User Manual
Remote controller Haisen HD05R (Iris p/n: RC-HD05R)
Detailed programming procedure
5s →30m
50 %
100 %
DIM +
DIM -
50 %
10 %
0s →∞
LIGHT LEVEL
TIME
LAST MOVEMENT DETECTED BY SENSOR
10 %
PHASE 0 PHASE 1 PHASE 2
Select the motion sensor detection area
note: the wider the area, the faster motion is detected
Select the duration of the hold period
note: if no movement, intensity remains at maximum for this duration
Select the stand-by period dim level
Note: lighting level is a % of maximum intensity
Select the duration of the stand-by period
note: length of time the luminaire remains in reduced lighting before switching off
Disable the function « Ambient light detection »
1- Press to activate programming mode
2- Press on « Start » ( flashes) and press the parameter to be modified
(parameter icon flashes)
3- Press once all parameters have been changed
Modify the parameters using the + or - keys
S
4- Select the motion sensor detection area
note: the wider the area, the faster motion is detected
Procedure
Notes