IrriGreen 2 User manual

Irrigreen2 Installation Manual
Irrigreen® Digital Sprinklers Wi-Fi/Cloud Controller
Ultrasonic Flow Sensor Waterproof Plug-n-Play Cabling
16 Digital/12 Valve Controller 32 Digital/24 Valve Controller
Installation Video
Irrigreen.com/professionals-logged-in/
Password: goirrigreen!
IG2-INST-1.0.3
1

Irrigreen Products
Controller Cable
(50 ft w/end plug)
Digital Sprinkler
(1 per zone, ~2000 sq. ft.)
Irrigreen2 Wi-Fi / Cloud Controller
16/12: 16 Digital Zones, 12 Valve Zones, 1 MV/P
32/24: 32 Digital Zones, 24 Valve Zones, 2 MV/P
24 VAC Transformer
w/ 10’ wire (40VA, indoor)
1” Ultrasonic
Flow Sensor 2
Cable Tee (w/end plug)
Sprinkler Cable (50ft)
CableLok
Snaps over water-
proof connectors
FlexPipe (15 in.)
1” Male Pipe Thread
connects to mainline tee

Other Items Needed
1 “ Mainline PVC or poly
Small valve boxes
*One for each Digital Zone
(protect cable connections and hold
any extra sprinkler cable
*One for the flow sensor
*As needed for valve zones
Grease cap /wire nut
connectors (for Flow Sensor)
3M® DBY/R, Orbit® 57002 or similar
(IrriGreen supplies these)
1” Tees with 1” female
pipe thread (PVC or poly)
For connecting Flex-Pipe to mainline
1” Elbows PVC or poly
Two conductor wire
Connects flow sensor to the
IrriGreen2 Controller
3

Irrigreen System Requirements
Constant pressure, good flow, clean water
•40 - 80 psi (Any constant pressure between 40 - 80 psi)
•10+ gpm (Must be checked during preliminary site visit)
•Well systems require a constant pressure pump or regulated constant
pressure supply; e.g. with a PRV set below the lowest pump setting
•Filter needed for any water source with particulates (sand, grit)
500 Micron filter (similar to drip systems) recommended
4

Irrigreen Throw Distances
Verify psi before placing heads
Low flow may affect throws
Maximum Throw
40 psi 25’
50 psi 27.5’
60 psi 30’
70 psi 32.5’
80 psi 35’
Minimum Throw
40 psi 5’
50 psi 5’
60 psi 5’
70 psi 5’
80 psi 5’
5
Total Area
At 60 psi, one Irrigreen head will evenly water up to ~2000 sq.ft.

System Design (1 of 2)
One Head per Zone
Place Head to Reach Farthest Corner, 25-35 Feet
Exact placement
not critical as you
can program the
head to the shape
of the zone
Don’t overlap
sprays or zones
Installation hint:
Walk in from the
corner with a wheel
and place a flag at
25-30’ for head
placement.
NOTE: The zone
start up point
(Position 1)
must be set at
least 10 feet so
the head has
enough
flow/pressure to
fully “pop up”.
After head is
fully popped up,
OK to set points
as short as 5
feet.
6

System Design (2 of 2)
One Head per Zone
Place head 5 feet or more from the nearest edge*
*For narrow
zones less than
10’ wide, place
head along edge
and program in
a ~180 degree
pattern
Design hint:
For watering
shrubs/bushes
without drip,
you may
program
streams to
shoot out and
hit individual
bushes
7

8

Sprinklers are Pre-numbered for each Zone
They will run in that numerical order*
Locate each sprinkler in the numerical order you want them to run*
9
Digital Sprinklers have Zone Numbers
1-8, 9-16 assigned at the factory
Zone Number on Sprinkler box Zone Number on Sprinkler
*Head #1 runs first
Head #2 runs second
Head #3 runs third
Etc.

Digital Sprinkler Head Depth
Position head so the Digital Sprinkler
cap is slightly above grade
10

11
Digital Sprinkler

Flush all lines before and after
installing heads
1. Before installing any heads, flush lines
to remove all dirt and sand
2. After all heads are installed, run the last Digital
Sprinkler(s) on the end of all pipe runs at maximum throw for
several minutes to remove all air from the system.
3. Run all Valve zones to remove all air from the system
Trapped / deadhead air anywhere in the system acts as an
“air piston”, causing calibration errors
12

13

14
2 AAA

Controller Terminals
15
Flow Sensor 1
Rain/Soil
Sensor 1
Digital
Sprinklers 1-8
Master Valve
Valve Zones
1-12
Digital
Sprinklers 9-16

16

Irrigreen2 App
Log onto Irrigreen Wi-Fi network with your mobile device to get started
Rollover to property Wi-Fi network for system monitoring (see App Manual)
Irrigreen private Wi-Fi signal from Controller (2.4 GHz)
Wi-Fi Range: Wi-Fi is a low-power radio signal
Controller location, landscape elevations (signal going through
soil), house construction (stucco, steel, etc.) affects Wi-Fi
range. Wi-Fi extenders will extend range while mapping zones.
IrriGreen has Wi-Fi extenders available.
Note:
For Irrigreen system monitoring, roll the system over to
the property owner’s Wi-Fi network for internet access.
Rolling the Wi-Fi over to Property’s Wi-Fi network will
typically improve Wi-Fi range. 17
White IG2
App Icon
(The Green and
Blue Icon apps are
for legacy systems)

Controller Buttons
18
“MODE”
Blue button runs
all zones and
shuts down zones
“RESET” Green button:
resets the system
“SELECT” Red button
connects controller to the
IrriGreen Wi-Fi router, if
needed, for Wi-Fi connectivity
NOTE: Hold buttons
down for 2-3 seconds

Controller Indicator Lights
19
LED 2 - Blue
System is
watering
LED 1- Green System has
power when blinking
LED 3 - Red
System Error
System Status:
Green LED glowing (blinks off
every 8 or 16 seconds):
Wi-Fi is Rolled over to
property Wi-Fi, with internet
Green LED not glowing
steadily (blinking on every 8
or 16 seconds):
Controller is not rolled over,
Irrigreen Wi-Fi network
available.

20
NOTE: If a Genius Sprinkler
does not have a zone number
or its zone number needs to
be changed, see “Advanced
Zone Address” instructions.
Digital Sprinklers are Connected with Cables
Daisy-chain up to eight Digital Sprinklers per run
Other manuals for 2
1
Table of contents
Popular Controllers manuals by other brands

Ascon tecnologic
Ascon tecnologic Y39 operating instructions

Omron
Omron SYSMAC PLC Basic Technical guide

Granville-Phillips
Granville-Phillips 270001 004 instruction manual

Johnson Controls
Johnson Controls FEC26 Series installation instructions

ABB
ABB ACS150 series user manual

Danfoss
Danfoss PVED-CLS Startup guide

Omron
Omron SYSMAC CS Series Programming manual

Linak
Linak TECHLINE LA33 user manual

Emerson
Emerson Dixell XR40CX Installing and operating instructions

ABB
ABB ACS 600 Series Hardware manual

Surpass
Surpass SP-16AMC operating manual

Regada
Regada Rematic UMR 1PA-Ex Installation, service and maintenance instructions