manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Iskra
  6. •
  7. Measuring Instrument
  8. •
  9. Iskra MI7350 User manual

Iskra MI7350 User manual

USERS MANUAL
Contents:
1. Short description of signalling apparatus
2. Operating description
3. Technical data
4. Characteristic data of signalling apparatus
5. General data
6. Wiring of instrument
1. SHORT DESCRIPTION OF SIGNALER
This is electronic signalling instrument with analog display.
Electronic is mounted in plastic housing. On the signaller front the
analog instrument displays measuring value. Signalling LED-s MAX
ΙΙ and MIN Ιindicates when measuring value is greater or lover then
limit value. On the back side of the instrument are two potentiometers
for adjusting a lower limit (CHANNEL Ι) and upper limit
(CHANNEL ΙΙ) of signaller. Also there are potentiometers for delay
time adjusting (DELAY Ιand DELAY ΙΙ).
2. OPERATING DESCRIPTION
Versions of signalling instrument provide use in various applications.
Versions of inputs provide measuring and signalling of different
physical quantities. Relay outputs can control signalling or control
elements. Limit value for lower and upper limit can be adjusted on
rear of the instrument by potentiometers in range of 0 ... 100%.
Delay of activating of relay outputs can be adjusted on rear by
potentiometers in range 0,5 ... 30 s. Pointer on scale displays value of
measuring input. LED on scale illuminates when input value becomes
greater then MAX ΙΙ limit value or lower then MIN Ιlimit value.
After delay time interval if input value stays out of limit relay
energies. Relay ΙΙ deenergizes when input value is lover then MAX ΙΙ
limit value. Relay Ιdeenergizes when input value is greater then MIN
Ιlimit value.
3. TECHNICAL DATA
3.1.INPUTS
3.1.1 DC voltage and DC current inputs
Measuring system: Instrument with moving coil for
measuring DC current.
DC V - meter ranges: 40 mV ... 600V
Accuracy class: 1,5 %
Input resistance: > 10 MΩfor ranges 40 mV ... 4 V
> 1 MΩfor ranges 5 V ... 600 V
DC A - meter ranges: 25 µA ... 5 A
Accuracy class: 1,5 %
Input resistance is range dependent on ranges.
Shunt voltage is 100 mV
3.1.2 AC voltage and AC current inputs
Measuring system: Instrument with moving coil and
rectifier for measuring AC current and
voltages.
AC V - meter ranges: 100 mV ... 600 V
AC A - meter ranges: 1 mA ... 5 A
Accuracy class: 1,5 %
Frequency range: 40 ... 400 Hz
Input resistance: > 1 MΩ; < 50 pF
3.1.3 Measuring of AC effective values
Measuring system: Instrument with moving iron for
effective values measuring.
AC Vef - meter ranges: 6 V ... 600 V
AC Aef - meter ranges: 100 mA ... 5 A (5/10 A)
Accuracy class: 1,5 %
Frequency range: 30 ... 100 Hz
NOTE: The signalling electronic is calibrated on r.m.s. values, at
a sine shaped wave
3.1.4 Frequency meter
Measuring ranges: 45 ... 55 Hz Accuracy class: 0,5 %
48 ... 52 Hz Accuracy class: 0,5 %
45 ... 65 Hz Accuracy class: 1 %
55 ... 65 Hz Accuracy class: 0,5 %
58 ... 62 Hz Accuracy class: 0,5 %
Input voltage: 60 ... 500 V AC
3.1.5 Thermometer with thermocouple probe
Temperature probe: thermocouple - IEC 584-1
Measuring ranges: 0 ... 250 °C ( Fe - const) J
0 ... 600 °C ( Fe - const) J
0 ... 1200 °C ( NiCr - Ni) K
0 ... 1600 °C ( PtRh - Pt) S
Temperature compensation: built-in, reference temperature 20 °C
Accuracy class: 1,5 %
3.1.6 Thermometer with Pt 100 resistance probe
Temperature probe: Pt 100 - IEC 751
Measuring ranges: -200 ... 0 ...+ 50 °C
0 ... 250 °C
200 ... 450 °C
400 ... 650 °C
Connecting: Two wires
Accuracy class: 1,5 %
3.2 OUTPUTS
Signaller has two output relays.
Switching element: potential free alternating relay
contacts. Maximal switching power at
resistive load: ≤600 VA (≤3 A,
≤250 V)
- Output CHANNEL Ι: adjustable by MIN limit value
- Output CHANNEL ΙΙ: adjustable by MAX limit value
4. CHARACTERISTIC DATA OF SIGNALING APPARATUS
4.1 LIMIT VALUE AND DELAY TIME ADJUSTING
Adjusting elements are on rear side of housing:
Range of limit value adjusting (MIN,
MAX) 0 ... 100 % F.S.D.
Setting accuracy: ±5 % (25 ... 75 %), ±15 % (0...25 %,
75 ... 100 %)
Setting reproducibility: < 2 %
Hysteresis: < 1 % F.S.D
Delay time adjusting range: 0,5 ... 30 s
Setting accuracy: ±20 % ±2 s
Setting reproducibility: < 2 %
ATTENTION: Isolate supplies before adjusting % F.S.D. or DELAY
settings!
MI7350
ELECTRONIC SIGNALER
5. GENERAL DATA
5.1 SUPPLY
110/230 V ±10 % 45 ... 65 Hz or 24 V DC
Power consumption: 2 VA
5.2 TEMPERATURE LIMITS
Operating temperature range: 0 ... 55 °C
Storage temperature range: -20 ... 60 °C
Relative humidity: ≤75 % yearly average, no
condensation
5.2.1 Supply voltage influence:
< 0,2 % for ±10 % Un
5.3 HOUSING
Material: plastics flame - retardant (flammability
class UL 94 V - O)
Front dimensions: 96 mm x 96 mm ( DIN 43700 )
Panel cut-out dimensions: 92 mm x 92 mm
Installation depth: max. 120 mm
5.4 PROTECTION DEGREE
Corresponding to DIN 40 050:
Housing IP 52
Connector IP 00
Safety class II in accordance toIEC 348, DIN 57411
5.5 ELECTRICAL CONNECTIONS
Screw Connector: for wires 2,5 mm2
5.6 MOUNTING METHOD
Into panel cut-out, held by fixing elements Mounting position must be
rectangular to basis.
ATTENTION: Before inserting the instrument into panel cut-out
remove the connector.
5.7 WEIGHT
Approx.: 0,6 kg
6. WIRING OF INSTRUMENT
6.1 POWER SUPPLY CONNECTING
Signaller is constructed for power supply:
230 V ±10 % 45 ... 65 Hz or
110 V ±10 % 45 ... 65 Hz or
24 V DC
6.2.CONNECTION DIAGRAMS
6.2.1 DC V - meter
AC V - meter
AC Veff- meter
6.2.2 DC A - meter
AC A - meter
AC Aeff- meter
6.2.3 Frequency meter
6.2.4 Thermometer with thermocouple probe
6.2.5 Thermometer with Pt 100 probe
ATTENTION: Wires resistively plus compensation resistor = 10
Ω
.
Otherwise the instrument will display incorrect
value.
Pt 100 (RTD probe)
Rp = wires resistively compensation resistor: built-in potentiometer
Rl = wires resistively
Rp + Rl = 10 Ω
Printed in Slovenia •Subject to change without notice •Preliminary version 02 / May. 2008 •

Other Iskra Measuring Instrument manuals

Iskra NPL 20 User manual

Iskra

Iskra NPL 20 User manual

Iskra MI7054 User manual

Iskra

Iskra MI7054 User manual

Iskra WM3x6 Series Operating manual

Iskra

Iskra WM3x6 Series Operating manual

Iskra ME382 User manual

Iskra

Iskra ME382 User manual

Iskra PNA760 User manual

Iskra

Iskra PNA760 User manual

Iskra WM3M4 User manual

Iskra

Iskra WM3M4 User manual

Iskra PNA 784 User manual

Iskra

Iskra PNA 784 User manual

Iskra IE14-S User manual

Iskra

Iskra IE14-S User manual

Iskra MC320 User manual

Iskra

Iskra MC320 User manual

Iskra WM1-6A User manual

Iskra

Iskra WM1-6A User manual

Popular Measuring Instrument manuals by other brands

Thermo Scientific 2210AM manual

Thermo Scientific

Thermo Scientific 2210AM manual

GANN HYDROMETTE BL LG 17 operating manual

GANN

GANN HYDROMETTE BL LG 17 operating manual

Hazet Brake Fluid Tester Application note

Hazet

Hazet Brake Fluid Tester Application note

GREISINGER GMH 3750 operating manual

GREISINGER

GREISINGER GMH 3750 operating manual

Agilent Technologies E2730A Installation and operation manual

Agilent Technologies

Agilent Technologies E2730A Installation and operation manual

MRC PS-9303SD Operation manual

MRC

MRC PS-9303SD Operation manual

Essilor Eye-Ruler 2 installation manual

Essilor

Essilor Eye-Ruler 2 installation manual

Bushnell NEO GHOST user manual

Bushnell

Bushnell NEO GHOST user manual

Motorola R-20018 manual

Motorola

Motorola R-20018 manual

PCB Piezotronics IMI SENSORS 646B10 Installation and operating manual

PCB Piezotronics

PCB Piezotronics IMI SENSORS 646B10 Installation and operating manual

Osaka OI 22-0 user manual

Osaka

Osaka OI 22-0 user manual

Scout MT-700 Series Operation manual

Scout

Scout MT-700 Series Operation manual

Seametrics FT400 General information

Seametrics

Seametrics FT400 General information

Turtle Tough PEEK installation manual

Turtle Tough

Turtle Tough PEEK installation manual

Keysight Technologies 86120B user guide

Keysight Technologies

Keysight Technologies 86120B user guide

frako EM-PQ 2500 operating manual

frako

frako EM-PQ 2500 operating manual

AXE MCH Series Operation manual

AXE

AXE MCH Series Operation manual

Tektronix DPO7OE Series user manual

Tektronix

Tektronix DPO7OE Series user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.