iWave WR-10 User manual

WR-10 色差仪说明书
Colorimeter User Manual

CONTENT
Safety Instructions.............................................................................................1
Notes...................................................................................................................1
1. Storage......................................................................................................2
2. Use............................................................................................................2
Overview.............................................................................................................2
I. Structure...........................................................................................................4
1.1 Appearance.............................................................................................4
1.2 Power...................................................................................................5
1.2.1 Battery.........................................................................................6
1.2.2 Power Adapter..........................................................................7
II. Operation........................................................................................................7
2.1 Turn on ...................................................................................................7
2.2 Color Difference Measurement ...........................................................7
2.2.1 Type Sample Measurement...................................................8
2.2.2 Sample Measurement.............................................................9
2.3. Check out Information.........................................................................10
2.3.1 Type Sample Record.............................................................10
2.3.2 Sample Record.......................................................................12
2.4. System Setting.....................................................................................12
2.4.1 Auto Save................................................................................13
2.4.2 Manual Save...........................................................................14
2.4.5 Language Selection...............................................................14
IV. Product Specification...................................................................................

WR-10 User Manual
MeterTo
1
Safety Instructions
In order for safe and proper use of the instrument,
please read carefully and follow the instructions of the
manual.
Use only original power adapter and original battery to
avoid fault or damage of the instrument.
Upon long time no use, cut off external power and remove
the battery to avoid damage to the instrument resulting from
battery fluid overflow.
Do not use the instrument under the conditions with
flammable and explosive gases, dusts or smokes to avoid
accident.
Do not use the instrument under the conditions of strong
magnetic field, rattling, dust and smoke to avoid unexpected
data and performance failure.
The product is a precision instrument, do not disassemble it
without permission, or it may be damaged and unrepairable.

WR-10 User Manual
MeterTo
2
Notes
1. Storage
● Upon long time no use, put the instrument into a packing box;
● Store the instrument in a cool and dry environment with a
temperature at -10°C~50°C and relative humidity under 85%;
2. Use
● When using the instrument, the ambient temperature should
be 0°C~40°C, relative humidity at 85%, without condensation;
● Do not use the instrument under the conditions of strong
magnetic field, rattling, dust and smoke to avoid unexpected
data and performance failure.
● Prevent foreign objects as liquid, powder or solid etc. from
entering into the instrument to avoid unexpected measurement
data.
Overview
The Colorimeter is a professional colorimeter designed and
produced subject to the relevant standards of International
Commission on Illumination (CIE) and national stands. Being
with brand new imported key components, the instrument is well
designed and features in precision, stability, easy handling, easy
to learn and cost-effective.
The instrument applies to the color quality control, color
difference control, color difference analysis, sampling testing
and online testing for industries as textile, printing and dyeing,
garments, shoes, leather, chemical, plastic, pigment, paint, ink,
printing, metal, photography and toys etc., as well as to the

WR-10 User Manual
MeterTo
3
auxiliary color matching during the processes as injection, inking,
painting and spraying coating etc.

WR-10 User Manual
MeterTo
4
1. Up
2. Down
I. Structure
1.1 Appearance
Figure 1. Instrument Appearance
Up - move the position of the cursor in the
screen; adjust the value of the activated items .
Down - move the position of the cursor in the screen;
adjust the value of the activated items.
Paging - Switching between tabs.
Saving - Save settings.
Confirm - Confirm or activate selected items in the
11.Measurement port
9.Battery
cover
5. Saving
3. Confirm
4. Paging
6. witch
10. Measurement
11.Measurement
port
8. Printing interface / DC connector
7.Show
screen

WR-10 User Manual
MeterTo
5
screen (a blue background of the item will be changed to a
green background after activation); fast switching between
"standard measurement" and "sample measurement".
Show screen - show measurement result etc.
Measurement - Measuring
Measurement port - Optical channel for measuring.
Switch - In (I) or Out (O) of the instrument.
Printing interface - connect to the printer to print the
measuring data.
Battery cover - cover for the special lithium battery
compartment DC connector - dedicated power adapter
connector.
1.2Power
The Colorimeter is powered by dedicated power adapter or
special lithium batteries, the use of other facilities for power
supply may damage the Colorimeter.
Ensure that the Switch is on Out (O) before connecting to the power
adapter or mounting the battery.

WR-10 User Manual
MeterTo
6
1.2.1 Battery
1. First check and confirm if the
Switch is on Out (O), then
following the arrow direction as
shown on Figure 2, take out the
battery cover by pressing down.
Figure 2. Remove the battery cover
2. Mount the battery into the
compartment as shown in
Figure 3,
pay attention to the front and
back of the battery.
Figure 3. Mounting the battery
3. Follow the directions on
Figure 4, press up to mount the
battery into the compartment.
Figure4. Mounting the battery cover

WR-10 User Manual
MeterTo
7
1.2.2 Power Adapter
1. First check and confirm if the
Switch is on Out (O),
2. Plug the input cable of the
power adapter as shown on
Figure 5 into the DC connector.
Figure 5. Power Adapter connection
II. Operation
2.1 Turn on
Before turning on the instrument, check if the external
power has been connected or the battery has been mounted,
ensuring a power supply to the instrument, then start the
instrument, the screen will show starting Logo.
After the completion of boot interface, instrument into the
self-test program, ensure the normal working of the instrument.
2.2 Color Difference Measurement
There are two steps for the color difference measurement
which are "Type Sample Measurement" and "Sample
Measurement".

WR-10 User Manual
MeterTo
8
1. The Type Sample measurement gets the standard color
parameters of a Type Sample;
2. The Sample measurement gets the parameters of the
sample needed to be measured, while calculates the color
difference data between the Sample and the Type Sample.
2.2.1 Type Sample Measurement
As shown on Figure 6, the Type Sample measurement can
be performed to get the color parameters of a Type Sample. The
color parameters measured will be shown on the measurement
page.
In the upper right corner of the page to display the test
current conditions, including light sources, lighting and light
mode.

WR-10 User Manual
MeterTo
9
Figure 6. Type Sample Measurement Page
2.2.2 Sample Measurement
After completing the Type Sample measurement, if it is
required to measure the color difference between the Type
Sample and the Sample, press "Paging" to switch the
screen to "SAM. " page as shown on Figure 7, the color
difference parameter measured will be shown on the
measurement page.

WR-10 User Manual
MeterTo
10
Figure 7. Sample Measurement Page
Meanwhile, color bias will be shown on the right of the page
to provide an intuitive color difference analysis.
2.3. Check out Information
2.3.1 Type Sample Record
Press "Paging" to jump to "Check out Information"
page as shown on Figure 8 to check the saved data by "Up"
and "Down" keys, if required.

WR-10 User Manual
MeterTo
11
Figure 8. Check out Information Page
In the current page, press "save" button can be
activated in Figure 9 dialog box, choose "sample into" or
"standard delete" operation.
Figure 9 Selecting operation

WR-10 User Manual
MeterTo
12
2.3.2 Sample Record
After selecting the Type Sample to be checked, select
"Sample Record" option to switch the screen to the Sample
record page of the Type Sample as shown on Figure 10, then
select Sample record by "Up" and "Down" keys to
check out the color difference records of each Sample.
Figure 10. Check out Information Page
2.4. System Setting
Press "Paging" to switch the screen to "System
Setting" page as shown on Figure 11 to set the data saving ways
as well as light mode, Light source(D50, D65, F11), tolerance,

WR-10 User Manual
MeterTo
13
backlight time, the system date and time during the
measurement.
Figure 11. System Setting Page
2.4.1 Auto Save
As shown on Figure 19, there are two ways for saving which
are "Auto Save" and "Manual Save".
When setting to Auto Save, system will auto save each time
measurement data of the Type Sample or the Sample. If the
saving records of the Type Sample or the Sample are full, the
measurement data will not be saved and will pop up a window
as shown on Figure 12 to prompt if the storage should be
cleared.

WR-10 User Manual
MeterTo
14
Figure 12. Pop up Window
2.4.2 Manual Save
When setting to Manual Save, system will not auto save
data, it is required, after finishing measuring, to press "Save"
for manually saving the data and will pop up a prompt box
as shown on Figure 13.
Figure 13. Prompt Box
2.4.5 Language Selection
The colorimeter in the English language version, only in the
"System Settings" page can be selected.

Table of contents