The product is a component ofthe JABLOTRON 100 system.
/t serves for poweing and controlling electric door locks and
access control units from the system BUS. Duing lock operation
the included bafteries supply enough current to open an electric
lock, duing the leading edge of the cunent pulse. The JA-120N
can be mounted practicaily in any place where it is difficult to
install an external power supply to control an electric lock
This module reacts to control panel PG outputs or it can be
activated by a release key connected to the lN tetminal. The
module is supplied inside a JA-190PL installation box.
It should be installed by a trained technician with a valid
ceftificate issued by an authorised distributor.
lnstallation
Figure 1: 1 - rechargeable bafteies; 2 - DOOR output indicator,
3 - JA-100 BUS activity indicator; 4 - lN input activation indicator;
5- LEARN (enrollment)/ tamper contact; 6 - BUs terminals;
7 - input and output terninals (Yo)
1. We recommend removing the module's PCB to avoid
unwanted damage during installation. Punch the holes into
the JA-190PL rear plastic part for cables. Insert the BUS
cables and attach the plastic base onto the required place
using screws.
^4, When connecting the modute to the
ZE\ system BUS, always switch the power off.
2. Put the PCB back onto the olastic base. Connect the BUS
wires to the BUS terminals (6) and the cables for door lock
control to the l/O terminals (7). Always use CC-01
(Jablotron) cable for connecting to the control panel. For
connection of the door lock or the external power supply use
cables with an adequate cross-section.
Terminal descriotions:
DOOR - + t2V outout for electric lock control
COM, lN - Input terminals serving for activation by the
release button (reaction NO/NC).
GND - Common terminal for an external power
supply and for electric door lock control
+12V - Input terminal for an external power supply
(the DE 06-12 is recommended)
Proceed according to the control panel installation manual.
Basic procedure:
a. When the system has been turned on then the yellow
LED (3) flashes and it indicates the module has not been
enrolled to the system yet.
b. Using F-Lrnk software, select the required position in the
Devices window and launch enrollment mode by clicking
on the Enroll ootion.
c. Press the LEARN/TAMPER (5) button in the module -
the module is thus enrolled to the system and the yellow
LED indicator goes off.
Put the cover on the module.
Setting the module properties
The module properties can be set in the Devices window of
the F-Link software. When at the module position, use the
lntemal setfings.option to open a dialogue wlndow where you
can set the following options:
LED indication - Enable / disable optical indication by the red
LED (4) of triggering the lN input.
The JA-120N BUS module for electdc door locks 1 I 2
DOOR reacts to PG status - Determines which PG outout or
outDuts the module reacts to.
Minimum PG switching time - Sets the minimum switching
time of the DOOR output regardless of the PG output impulse
length.
Maximum PG switching time - Sets the maximum switching
time of the DOOR output regardless of the PG output impulse
length. When the lN input is triggered the DOOR output is
always switched on for that predefined time.
Nofe: the minimum switching time can't be set to a higher
value than the maximum value. The F-rrnk software adiusts its
offer of those parameters dynamically.
lN inout ootions:
Disabled The module doesn't react to lN inpul
activation
Manual control Triggering the lN input switches on
the DOOR terminal for a predefined
iime according to the "lvlaximum PG
switching time"
System Triggering the lN input causes the
control panel to react according to
the reaction set at the module's
position in F-rink (Reaction column)
lN input inverted: Determines the logic of the lN input NCINO.
The input is not balanced and is set to NO as a factory default
(option disabled).
DOOR input inverted: This option inverts the logic of the
DOOR output for e.g. reverse locks. When the option is checked
and the input is in standby a voltage occurs on the DOOR
output.
/Vofei for correct functioning it is necessary to power the module
fiom an extemal power supply (for instance: the DE 06-12).
Blocking the lN input by section: This option can block the
lN input by setting the section to which the module has been
enrolled. The option is only available if Manual control of the lN
input has been enabled.
Function button during communication fault: This option
keeps the module active, with backup control of the DOOR
output by lN input triggering when communication with .the
conirol oanel is lost.
Unlock the IN input during a fire alarm: This parameter
unlocks the lN input during a fire alarm even though blocking the
lN input by the section has been enabled. This option is
available only if the function 'Blocking the lN input by section" is
enabled.
Triggered tamper: This parameter can disable the tamper
contact for cases when the module is going to be installed inside
a different box or into a box with different tamper protection.
t\Iofe.' The module is designed for use with very high quality
N|MH batteries (Eneloop 1.2V AA ones supplied) in a positive
operational temperature range. NiMH batteries have unsuitable
behaviour in a negative operational temperature range so in
this case we recommend using NiCd batteries in the module.
Apolication recommendation:
We recommend using the module with door locks complying
with the following parameters:
- Standard locks 12 V DC / max. 300 mA
- Reverse locks 12 V DC I 17O mA (for reverse door locks
it is necessary to plug in an external power supply, for
example the DE 06-12)
4.
f
-9.
z
c
q)
63.
;E:
\u (E6
=;E
r >:;
<YE
J-{
<Pg
zxB
C)fit:
;7s=
L^l
n*q)
v6E
J*-
m ",?
<6K
'1 0- c)
eiI
Figurc 2: JA-190PL installation box dimensions
M1Y57700
Tech n ical specifi cati ons
Power from the control panel BUS (9...14 V)
3x NiMh Eneloop 1 .2 V AA batteries (1900 mAh)
External Dower
Current consumption for cable choice
Current consumption in standby mode
DOOR output load (Eneloop batteries):
Pulse (1s)
Continuous
Dimensions
Weight
Operationa temperature range
with the NiMh Eneloop batteries -10'C - +40 'C
with the NiCd batteries -20'C - +40'C
Gtade2
According to EN 50131-1, EN 50131-3,
Operational environment according to EN 50131-1 ll. General indoor
Also complies with EN 50130-4, EN 55022
C€ JABLOTRON ,qLARMS a.s. hereby declares that the JA-120N
module is in compliance with the essential requirements and other
relevant provisions of Direclive 2w4l16lEc, 2011/65/EU. The
original of lhe conformity assessment can be fcund at
www.iablotron.com - Technical Support section
Note: Although this prcduct does not contain any harnful materials
we suggest )tou retum the producl to the dealer or directly to the
oroducer after use. For more detailed information visit
www.iablotrl3n.com.
+12V
60 mA
10 mA
600 mA
300 mA
90x90x35mm
185 g
Classification
g
A
The JA-120N BUS module for electric door locks 2t2 M1Y57700

Popular Control System manuals by other brands

Mitsubishi Electric AJ65VBTCU-68DAVN user manual

Mitsubishi Electric

Mitsubishi Electric AJ65VBTCU-68DAVN user manual

Veimart VM-10 Instructions for use

Veimart

Veimart VM-10 Instructions for use

HEIDENHAIN TNC 426 B user manual

HEIDENHAIN

HEIDENHAIN TNC 426 B user manual

Raven RCM Calibration and Operation Manual

Raven

Raven RCM Calibration and Operation Manual

KOOLAIR KOOLCOM manual

KOOLAIR

KOOLAIR KOOLCOM manual

ICS Tunnel Master wbc installation guide

ICS

ICS Tunnel Master wbc installation guide

Fagor CNC8 070 Error code list

Fagor

Fagor CNC8 070 Error code list

TAC I/NET 2000 Getting started

TAC

TAC I/NET 2000 Getting started

vistaCNC iMach III P1B Manaul

vistaCNC

vistaCNC iMach III P1B Manaul

HEIDENHAIN POSITIP 880 installation instructions

HEIDENHAIN

HEIDENHAIN POSITIP 880 installation instructions

CAME G4040EZT installation manual

CAME

CAME G4040EZT installation manual

Danfoss m2 instructions

Danfoss

Danfoss m2 instructions

Garmin GFC 600H pilot's guide

Garmin

Garmin GFC 600H pilot's guide

nologo Active-S Manual and directions for the installer

nologo

nologo Active-S Manual and directions for the installer

Leviton 600 Series user guide

Leviton

Leviton 600 Series user guide

Anilam 3000M manual

Anilam

Anilam 3000M manual

Soca ST-320 Operation and installation manual

Soca

Soca ST-320 Operation and installation manual

progressive automations PA-40 user manual

progressive automations

progressive automations PA-40 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.