Jadever JWL Series User manual

(II)
JWL 0
CONTENTS
Appendix 1: printing format (Optional)
Appendix 2:U.KEY Connector
1. Introduction………………………………….……………………………………………….. 1
2. Precautions…………………………………….…………………………………………….. 1
3. Before Using the Product
3-1 Unpacking and Checking……………………………………………………………………….
3-2 Installing Components ………………………………………..………………………………..
3-3 Leveling the Scale………………………………………………..……………………………..
1
1
1
4. Product Introduction
4-1 Specifications & General Features …………………………………...................................
4-2 Front Panel …….……………………………………………………………………………….
4-2-1 LCD display……………………………………………………………………………………
4-2-2 Keyboard………………………………………………………………………………………
4-3 Power Supply……………………………………………………………………………………
2
3
3
4
5
5. Function Setting and Description of Parameter Values
5-1 Function Setting ………………………………………………………………………………..
5-2 Description of Parameter Values……………………………………………………………..
5
6
6. Calibration…………………………………………………………………………………… 9
7. Operation
7-1 weighing …………………………………………………………………………………………
7-2 manual tare &preset tare…………………………………………………………………........
10
10
7-3 check weighing………………………………………………………………………………….
7-4 Simple Counting…………………………………………………………………………………
7-5 Accumulation, Accumulation Display and Accumulation Clearing…………………………
7-6 Printer initialization by the indicator operation………………………………………………..
7-7 Input commands………………………………………………………………………………..
8. Serial Interface
8-1 Diagram…………………………………………………………………………………………..
11
12
12
13
13
14
9. Troubleshooting and Error Message……………………………………………… 14
Manual_JWL_V2

(II)
JWL 1
1. Introduction
This manual contains installation and operation instructions for the JWL Series weighing
indicator. Please read the manual completely before installation and operation.
2. Precautions
Place the scale on a flat and stable◎surface (Refer to Section 3-3).
Verify that the input voltage and the plug type matches the local AC power◎supply (Refer to
Section 4-4).
Make sure power cord does not pose a potential obstacle or tripping◎hazard.
Keep the scale away from EMI noise,◎strong wind and vibration, which might cause
incorrect reading.
◎Avoid sudden temperature changes (suitable operating temperature is between -5℃~ 40℃.)
◎Do not drop loads on the platform.
Disconnect the power supp◎ly while cleaning the scale.
◎Do not immerse the scale in water or other liquids.
Service should be performed by authorized personnel only.◎
3. Before Using the Product
3-1 Unpacking and Checking
Open the package and check the instrument for transport damage. Immediately inform your
dealer if you have complaints or if parts are missing. The package should contain:
●Scalebody
●Weighing platform (plastic base with stainless steel pan)
●Power cord
●User manual
3-2 Installing Components
1) Before using the scale, remove the delivery protection screw (rotate counterclockwise),
which located underneath the scale, and cork the plug buckle.
Note: the JWL-30K model is shipped without the shipping protection screw.
2) Cover the weighing pans on the scale body properly.
3-3 Leveling the Scale
To compensate for small irregularities or inclinations at the location, the scale can be leveled.
The scale is equipped with a level indicator at the front panel .Adjust the leveling feet until the
air bubble in the indicator is centered as shown.
Note: The scale should be leveled each time its location is changed.

(II)
JWL 2
4. Product Introduction
1. level indicator
2. Front panel
3. Bottom housing
4. RS-232 interface
5. Plastic weighing pan
6. Stainless steel weighing pan
7. On/off switch
8. Two-stage switch
9. Power socket
10. Transport protection screw
11. Plug buckle
4-1 Specifications & General Features
Specifications
Model JWL-1.5K JWL-3K JWL-6K JWL-7.5K JWL-15K JWL-30K
Capacity (Kg) 1.5 3 6 7.5 15 30
Division-1 (g) 0.5 1 2 2 5 10
Division-2 (g) 0.2 0.5 1 1 2 5
Division-3 (g) 0.1 0.2 0.5 0.5 1 2
Division-4 (g) 0.05 0.1 0.2 0.2 0.5 1
Display LCD(liquid crystal display), digits 31mm high, with back lighting
Pan size 294X228X13.5mm
Scale Dimensions 341X294X104mm
Power Supply AC 110V/220V (AC±10%) or built-in rechargeable battery(6V/4A)

(II)
JWL 3
General Features
zAuto shut off, built-in rechargeable batteries or AC alternative
zMultiple functions: tare, preset tare, simple counting, check weighing, accumulation and display
for every deal.
zLarge bright backlit LCD with prominent 29mm high digits and LED backlight
zSoftware filtering design and adjustable weighing displaying speed according to different
environments.
zEasy operation with big keys and high weighing resolution
zSingle point calibration and linear calibration available
zRS-232 serial communication interface(PC, printer, relay)
4-2 Display
4-2-1 LCD Display
Low battery indication
Tare or Preset Tare Indication
Center of Zero Indication, The zeroing range is ±2﹪of weighing capacity.
Auxiliary display (parameter, accumulated number of weighments)
TARE Symbol “ ” points at “TARE” when manual Tare action is done.
Preset Tare Symbol “ ” points at “Preset Tare” when preset tare value is set.
“NET” Net weight--Gross weight minus Tare. Symbol “ ” points at “NET” when manual Tare or
preset are actions are done.
“UW” Under simple counting mode, Symbol “ ” points at “UW” when unit weight is lower than
4/5 of scale division. Unit weight is too small for ensuring accurate quantity calculations.
Charge Lamp
Red--- battery is charging

(II)
JWL 4
Green---battery is fully charged
HI lamp ON The weight on the weighing pan is greater than the upper limit.
OK lamp ON The weight on the weighing pan is between upper and lower limits.
LOW lamp ON The weight on the weighing pan is smaller than lower limit.
Units of measure
Stable indication
4-2-2 Keyboard
Short press steps through activated weighing units, release on desired one.
Displays gross and net weight by turns
1. Tares the weight of the container or accepts the keypad tare entries
2. Cancel the tare
3. Select the later parameter in the same level
4. Select the later record when checking the accumulation record
5. Shift keys rightwards
1. Zeros the display (within 2% of max.capacity)
2. Exits from certain operation without save
1. Long press to enter function setting
2. Deletes accumulation records

(II)
JWL 5
4-3 Power supply
Please verify the local AC power source and switch the two-stage switch to the proper place before
plugging into the power outlet.
Alternative power supply
1) AC 110V/220V (AC±10%)
2) (6V/4A) Internal Rechargeable Battery
Power Consumption
About 300 mW without backlight
About 380 mW with backlight
Low Battery Warning
When appears in the upper left corner of the weight window, the battery requires recharging.
The charge lamp turns green from red when the recharging is completed (which takes about 8
hours).Disconnect the scale from power supply when it is fully charged.
5 Function Setting and Description of Parameter Values
5-1 Function Setting
1. Press and hold M-/SETwhile powering on or long press M-/SETunder normal weighing mode
to enter function setting. The window displays “check”. Setting item “P00” displays
momentarily at the left bottom
2. Press /MR or TARE/ to shift between the functions
3. Delete the present accumulation record for the sake of wrong
accumulation operation under the accumulation mode.
1. Adds the indicated weight into accumulation memory
2. During editing, save and return to the higher option
1. Memory recall
2. Select the former parameter in the same level
3. Select the former record when checking the accumulation record
4. Shift keys leftwards
1. During setting value, add 1 to the current value
2. Set the upper limit of the check weighing
3. Print
1. During setting value, deduct 1 to the current value
2. Set the lower limit of the check weighing
3. Hold function

(II)
JWL 6
3. Press M-/SET to enter the parameter setting.
4. Press /MR or TARE/ to shift between the function parameters
5. Press M+/SAVE to save and return.
6. Press ZERO/ESC to exit without saving.
5-2 Description of Parameter Values
1. P00: Offset value
Displays the offset value and the keypad testing can be conducted
2. P01: Backlight mode
Off :No backlight
Auto:when weight value is stable or any key is pressed. But auto off after N seconds (N=2s, 5s,
10s, 20s, ever) with no action
Ever= It is always on when the weights over 9e
On:Backlight on
3. P02: Auto-off
Off:Non power off
5,10,30,60(minutes): Auto power off after keeping the scale unused for 5,10,30,60(minutes)
with “------”appears
4. P03: Unit setting
Init : Press key Unit to select the default unit when powering on the scale:pcs, 斤, lboz, g, kg,
final .(final=keep the final being used unit when power off )
Use: Press key Unit to select the weighing unit. on:Enable the unit off:Disable the unit
5. P04: Zero range
d0, d1, d2, d3, d4 and d5. (d= scale division)
6. P05: Hold function
HoLd – 0:no hold function
HoLd – 1:Peak hold. Press M-/SET key to release, and press +/PRINT/HI key to print out
the value.
HoLd – 2:Hold after stable. Press any key to release
HoLd – 3:Hold after stable. Release after moving away the article. The hold value is based
on the current value and its range could be set in sub menu. Accumulation hold function is

(II)
JWL 7
available, that is you could add article after hold the first value.
HoLd – 4:Press key HOLD/LO/- to hold. Press any key to release
Sub menu for Hold 3: INF (default: infinity) /10 /20 /50 /100 /200 /500 /1000 2000 /5000
/10000 /20000 /50000
H=current hold value, R=hold value range, d= division, W= actual weight
Keep to hold the value when |W-H|<=R*d, or the scale will exit the hold function. The scale will
cancel the hold function when empty the weighing pan, if choose INF setting.
7. P06: Check weighing memory
on:Check weighing on off:Check weighing off
8. P07: Check weighing function
on: Check weighing under the condition that the weight is within the limits and the stable
indication appears
off: Check weighing under the condition that the weight is within the limits
9. P08: Check Weighing buzzer beep
Hi:There will be a warning sound when the weight of articles exceeds the upper limit, and the
weight is equal or more than 20d
LO: There will be a warning sound when the weight of articles exceeds the lower limit, and the
weight is equal or more than 20d
ok:There will be a warning sound when the weight of articles is between the upper and lower
limit (including the upper and lower limits), and the weight is equal or more than 20d
out:There will be a warning sound when the weight of articles is beyond the upper & lower limit,
and the weight is equal or more than 20d
no.beep:no beep
10.P09: External device
= Birch printer(BP545,TDP643)
= Godex printer
= Adhesive sticker label printer
= Zebra printer
= Dot matrix printer(CK, SH-24)
=Large LED display
=Computer

(II)
JWL 8
=Connecting the weighing managing system
= CX large screen display (version 0.02)
= Thermal printer (Chinese available)
=the output format is compatible with Toledo Continuous Mode
Note: Special setting is needed by distributor if you want to print in Chinese.
= Work with the function of “Use Serial Keys” in Windows in outputting the data to Excel.
Reference user manual: http://www.jadever.com.cn/Download.aspx
=the U.KEY Connector function to work with PC directly.
11.P10: RS-232 Serial Transmission Rate
9600,4800,2400
12.P11: Print mode
contin:Continuous print
stable:Stable print(weight is equal or more than 20d)
key:Manual print by pressing key PRINT
13.P12: Print format
See the appendix (more than 100 formats. The appendix just shows two formats.)
14.P13: Filtering setting
Set the filtering level in which the stable indication turns on. The higher the setting, the slower
stabilization time
Options: 1,2,3,4
15. P14:Tare/Zero condition
stable :Only after the stable indication appears, Tare/Zero function acts after pressing down
key TARE or ZERO
always:Tare/Zero function acts by pressing down key TARE or ZERO even if it is not stable
auto: Press down key TARE or ZERO even if it is not stable, but Tare/Zero function acts after
stable
16.P15:RTC set
on: Enable RTC function
off: Disable RTC function

(II)
JWL 9
RTC setting:
When the window shows “on”, press M-/SETto enter RTC setting and the window shows the
year. Press /MR or TARE/ to choose date and time. Press M-/SETto enter setting.
Press /MR or TARE/ to shift key leftward or rightward; Press +/PRINT/HI or
HOLD/LO/- to change the value. Press M+/SAVE to return.
17.P 16: Zero-Offset function.
ON display the previous weight when powering on again
OFF not display the previous weight when powering on again
18.P17:Initialization
Press M-/SET then press M+/SAVE to initialization and the window display RESET.
6.Calibration
Note: Before calibration, please set the unit first. The unit used in calibration is the one that has
been set before. During the calibration procedure, press ZERO/ESC to return to normal weighing
mode without saving.
Here we take 3kg/1g as an example
1. Press and hold TARE while powering on. Do not release it till the window displays “CAL”.
2. With no load on the weighing pan, press TARE to start zero point calibration. “ ”is
blanking at the left bottom.
3. Wait till the window displays the first calibration value. “ ”appears at the left bottom.
Note: The first calibration value is default. With the same capacity, the last first calibration point
value can be recorded. If the capacity has been changed, the default value is 1/3 of full load. If
you need to change the value, do as the following: Press M-/SETto enter the value setting.
Press /MR or TARE/ to move leftwards or rightwards. Press+/PRINT/HI or
HOLD/LO/- to change the value. Press M+/SAVE to save.

(II)
JWL 10
4. Put the corresponding weight on the weighing pan, and then press TARE to complete the first
point calibration. “ ”appears at the left bottom.
Note: After the first point calibration, the window can display the weight value. If no need for
the other point calibration, move to step 6 to finish the calibration procedure.
5. Add another mass to the current weight. The window will show the total weight. Press TARE
to complete. “ ”appears at the left bottom.
6. Press M+/SAVE to save. After the window displays “ ”, it will return to normal weighing
mode.
7. Operation
7-1 Weighing
Begin with no load on the scale, the display reading zero. Place item(s) to be weighed on the scale.
The display shown is 1000.0g, gross weight.(The desired weighing unit should be selected before
weighing, refer to section 7-5.)
→
7-2 Manual Tare & Preset Tare
When weighing a sample that must be held in a container, tare stores the container weight into
memory.
Manual Tare
1) Under the weighing mode, place the container on the weighing pan, wait till stable
symbol appears, and press the key TARE. The container is tared.
→
2) Place the item(s) to be weighed into the container. The weight displayed is the net weight.
3) Remove all items from the weighing pan; the screen displays the tare value.
4) To clear tare with an empty pan, Press down key TARE or key ZERO/ESC.
Preset Tare
1) Long press key TARE for 3 seconds. The scale is now in Digital inputting mode with the
left-most digit blinking.
2) Press /MR or TARE/ to move leftwards or rightwards. Press+/PRINT/HI or

(II)
JWL 11
HOLD/LO/- to change the value. Press M+/SAVE to save and return to weighing mode.
3) Put the load on the container, the scale will automatically deduct the value of the container
from the total value.
NOTE: Press Key G/N to display gross and net weight by turns.
4) Clear the load on the container, and press TARE/ or ZERO/ESC to cancel the pre-tare.
7-3 Check Weighing
Lower limit setting
1. Begin by pressing down key HOLD/LO/-. The scale is now in digital inputting mode with the
right-most digit blinking.
2. To set the value of lower limit, press key /MR to shift leftwards, key TARE/ to shift
rightwards, key +/PRINT/HI to increase setting values and key HOLD/LO/- to decrease
setting value. Key M-/SET to enable or disable the weighing checking function.
3. To save the Lower limit and return to weighing mode, Press key M+/SAVE
Upper limit setting
1. Begin by pressing down key +/PRINT/HI.The scale is now in digital inputting mode with the
right-most digit blinking.
2. To set the value of upper limit, press key /MR to shift leftwards, key TARE/ to shift
rightwards, key +/PRINT/HI to increase setting values and key HOLD/LO/- to decrease
setting value.
3. To save the upper limit and return to weighing mode, press key M+/SAVE
Place the sample on the weighing pan, if the sample weight is under the lower weight range while
over or equal 20d, the LOW lamp will light up. If the sample is within the lower and upper weight range
while over or equal 20d, the OK lamp will light up. If the sample is over the upper weight range while

(II)
JWL 12
over or equal 20d, the HI lamp will light up.
7-4 Simple Counting
1. Press key UNIT to select the unit “PCS”.
2. Press key G/N,the ex-factory default sample quantity (10 pcs) is displayed.
3. Use key +/PRINT/HI or HOLD/LO/- to choose the sampling amount. Available options
are10、20、50、100、200、500、1000( pieces) .
4. Put the corresponding samples on the weighing pan, and then press key TARE/ .
“” is displayed momentarily before the display reverts to the sample quantity.
→
5. Remove the samples and put the load on, the scale calculates the amount of the load.
6. To go back to the normal weighing mode, remove the load and press key UNIT to select the
proper weighing unit.
Note:
1. The larger the sample size, the more accurate unit weight.
2. Symbol “ ” points at “UW” when calculated unit weight is lower than 4 / 5 of scale division.
7-5 Accumulation, Accumulation Display and Accumulation clear
Accumulation
Under the weighing mode, put the item on the weighing pan. Press key M+/SAVE at the
appearance of “”. “ ”is displayed momentarily before the display reverts to the weight of
the item.
Remove the item and the display goes back to zero before the next accumulation can register.(The
maximum is 99 pieces, display the latest 10 accumulation events in details )
Accumulation Display
Press key M-/SETto display the accumulation data

(II)
JWL 13
/MR or TARE/ to check the total accumulation and each accumulation event in detail.
The number of weighments is indicated by Auxiliary display at the left bottom.
XX=Total accumulation;XX=certain accumulation
Accumulation Clear
To clear accumulation data (total accumulation data or one of the accumulation events), press key
M-/SET while the data is displayed. To exit and return to normal weighing mode press key
ZERO/ESC.
7-6 Printer initialization by the indicator operation
1. Press M-/SETwhile powering on to enter parameter setting. Use key /MR or TARE/ to
shift to P09
2. Press M-/SETto enter the external device setting. Press /MR or TARE/ to choose the
printer model
3. Shift to certain printer model. Press M-/SETand the window will show “UNSUP” or “INIT?”
“UNSUP” means the printer is no need for initialization. Press ZERO/ESC to return.
“init?” means the printer is should be initialized. Press MR/SAVE to initialize the printer. When
the initialization is finished, the window will show “ok”. And then displays the printer model. Press
ZERO/ESC to return.
7-7 Input commands
Connect the indicator and computer. Run serial port debugging program on the computer. Input the
capital number “Z”, “T”, “R” ,“C”,“P”in the sending area, and the indicator can conduct the
corresponding actions.
Z=zero
T=tare
C=cancel tare
R/P=reading / print
8. Serial Interface

(II)
JWL 14
If external interface is needed, please select the proper three-in-one board first, which integrates
RTC (time display), RS-232 and relay (weight checking) functional module onto one circuit board.
Only after this board is adopted, the three functions can be realized.
8-1 RS-232 Diagram
Single Option
1) RS232+RTC+Relay+ (SH-24,BP545D , Godex and ZEBRA) printer
2) RS232+RTC+Relay+ LED Light Tower (Applicable to the quality control of the factory product
quantity or weight and that of the total production line.)
3) RS232+RTC+Relay+Computer
9. Troubleshooting and Error Message
Error Message Problem shootings
ERR0 Exceed the zero range The item should be within 2% of full load
ERR2 Exceed the initial zero point
1. Check whether there are other alien
articles on the scale pan, remove those
articles.
2. LOAD CELL failure, which requires to be
changed or to contact our Service.
ERR3 Exceed the A/D resolution
range
1. Check whether it is A/D failure, if yes,
please replace AD.
2. LOAD CELL failure, replacement is
required or contact our Service.
ERR4 EEPROM failure Re-sold EEPROM or contact our Service.
ERR5 Overload condition
Remove weight that is greater than the scale
capacity from the pan.

(II)
JWL 15
Appendix 1:printing format (Optional)
Printing Device Format Sample
PC prt-01
prt-02
prt-03
prt-04
ST: stable; UT: unstable;
NW: net weight;
GW: gross weight
ERR6 Exceeds the display range --------------------------------------------
ERR7 Accumulated number of
weighments exceeds the
display range
Delete the exceeding weighments
ERR9 Exceed tare or pre-tare range
The tare value should be over zero and less
than or equal to full load.
ERR10 Wrong calibration weights
Place the right weights( the calibration value
≤ full load)
2004.11.25 12:28:26
1. 000 kg
2004.11.25 12:27:58
G.W.:1. 500 kg
T.W.:0. 500 kg
N.W.:1. 000 kg
1. 000 kg
ST GW + 100.00 kg
UT NW - 200.00 kg
UT GW + 100.00 kg
ST NW - 200.00 kg

(II)
JWL 16
prt-05
ST: stable; UT: unstable;
NW: net weight;
GW: gross weight
prt-06
"ST," is the prefix
prt-07
prt-08
02 + mark + data (6 digits
without decimal point) +
decimal place + XOR
checksum high + XOR
checksum low + 03
BIRCH/GODEX/ZEBRA/CK prt-01
prt-02
CK prt-02
ST,GS,+ 100.00kg
ST GW + 100.00 kg
US,NT,- 200.00kg
US,GS,+ 100.00kg
k
ST,NT,- 200.00kg
k
2004.11.25 12:28:26
1. 000 kg
2004.11.25 12:27:58
G.W.:1. 500 kg
T.W.:0. 500 kg
N.W.:1. 000 kg
2010-11-12
13:14:15
G.W.:
1.48kg
T.W.:
0.00kg
N.W.:
1.48 k
g
ST,+ 100.00kg
UT GW + 100.00 k
g
ST,- 100.00kg
UT GW + 100.00 kg
- 100.00kg
UT GW + 100.00 kg
+ 100.00kg
UT GW + 100.00 k
g

(II)
JWL 17
DMP prt-01
prt-02
When appear under
display of accumulation,
press key PRINT to the print
out.
NOTE:
The printing sample could be of different kinds of formats. When there is specific demand about the
format, conduct as follows
1) As for BRICH/GODEX/ZEBRA/GP printers, the factory designs the format as planned and
email to the user. Add the format into the previous format file via computer. Then it is successful
to add the new format and able to print the new format.
2) As for DMP/CK printer, it needs to change the scale design
Appendix 2:U.KEY Connector
1.Introduction
Connect the scale with PC and set the parameter of external device as “U.KEY” on the scale,
then you could export the weighing data to PC in the form of EXCEL. With this function, you could
record/accumulate/average/data statistical analysis the testing data, which we could call it as
scale-computer data management function.
Most importantly, you don’t need any setup in computer, but only use U.KEY connector to link
computer system directly, such as EXCEL, Express System, ERP system and so on. This
2004.11.25
12:28:26
1. 000 kg
2012.04.26
13:05:33
G.W.:
100.00 kg
T.W.:
0.00 kg
N.W.:
100.00 kg
2010.01.01
06:31:54
(01) 1.765 kg
(02) 1.760 kg
(03) 1.760 kg
----------------
(03) 5.285 kg

(II)
JWL 18
connector is compatible with windows2000/xp/Vista/win7/win8/Linux/Android system, and the
weighing data will show on the position where the mouse cursor in.
With one USB port, you could connect scale to computer easily.
2.Precaution
2.1.Close the input method program before connecting.
2.2.Ensure the decimal point digit is same as the parameter setting of scale, if use EXCEL file in
computer.
For Example:
Scale shows: Total Weight: 1.000KG 、Unit Weight: 0.001g、Total: 1000PCS
EXCEL Setting: the decimal point digit should be 3 for total weight and unit weight column, and the
decimal point digit should be 0 for total column.
3.Setting
3.1.Prepare one computer with windows2000/xp/Vista/win7/win8/Linux system or Android pad.
3.2. Scale setting:
"PERI" = "U.KEY" (External devices)
"BAUD" = "9600" (Baud)
"PRT.M"= "KEY"/"STABLE" (Print Mode)
"RTC" ="ON"/"OFF" (Time)
3.3. Open the receiving port such as EXCEL or ECR system, and the weighing data will show on
the position where the mouse cursor in
4.Example:
4.1 EXCEL:

(II)
JWL 19
4.2. ERP System:
This manual suits for next models
5
Table of contents
Other Jadever Accessories manuals
Popular Accessories manuals by other brands

Leedarson
Leedarson 8B-SS-ZF-H0 user manual

weinor
weinor Terrazza Pure Maintenance Instructions and Directions for use for the end user

Axis Industries
Axis Industries SDU-1M Technical Description, Operating Instructions

Palram
Palram OLYMPIA 3x3.05m/10 manual

MORLEY-IAS
MORLEY-IAS MI-LZR Installation and maintenance instructions

LINDR
LINDR AS-80 manual