14314 PRODUCT SPECIFICATIONS
Specications
Power: 120VAC, 60Hz Signal Frequency: 908.4/916
Maximum Fan Motor Load: 2.5A
Range: Up to 150 feet from controller or closest Z-Wave device
Operating Temperature: 32-104° F (0-40° C)
Warranty: 5-year limited product warranty
Requires neutral wire. Switch must be mounted indoors
Control fan motor only, not intended for lighting control. No
more than two fans
Jasco Z-Wave In-wall
Smart Fan Control
www.byjasco.com 1
Design Features
· Remotely monitor with any
mobile device*
· May be used in single pole
installation or with up to four
Jasco model 46560 Add-on
switches in 3, 4, 5 or 6-way
 wiringcongurations
· Turn ON/OFF and control
speed level of the connected
Ceiling fan manually or via
Z-Wave remote control
(On/Off, High, Medium, Low)
· Can be Included in multiple
Groups and Scenes
· Supports Advanced
 Conguration;LEDstatus,
Invert switch (if unit is installed
upside down)
·ScrewTerminalinstallation;
requires wiring connections
for Line (Hot), Load, Neutral
and Ground. Traveler
wire required for multi pole
installation
· Use a standard size wall plate
for single gang installations
(wallplate not included)
· Interchangeable Paddle switch:
White & light almond paddle
included in package
· LED can be enabled/disabled
manually
· Inline traveler circuit protection
Z-Wave Plus Features
·Backward compatible with all
generations of Z-Wave devices
· Improved battery life and up to
50% more wireless range
· 250% faster processor
· 400% more memory
· 50% more energy efcient
· Supports wireless upgrades
to future-proof your home
White/light almond
paddles included
* Requires Z-Wave hub or controller,
functions may vary depending on brand.
14314 PRODUCT SPECIFICATIONS
www.byjasco.com 2
Single Location Wiring
Multi-Location Wiring
Space-Saving Screw Terminals
TRAVELER TRAVELER
TRAVELER
LOAD
LOAD
GROUND GROUND
JUMPER
LOAD
JUMPER
LINE
From Breaker Box
In from Line Switch
Out to Light (Load)
Load Switch
(Add-On Switch)
Line Switch
(Primary Switch)
From Breaker Box
Out to Light (Load)
LOAD
NEUTRAL
GROUND
LINE
TRAVELER
Installation Recommendations:
· Insert wires into holes, do not wrap wires around screws. Do not remove screws.
· Devices require a 1-gang U.S. wall box. 3½ in deep recommended, 2¼ in deep minimum.
· Indoor use only
· Visit http://www.ezzwave.com/hubs/ for hub compatibility
· Wallplates sold separately
· Trilingual Instruction manual – (English, French, Spanish)
14314 PRODUCT SPECIFICATIONS
Related Products - Z-Wave Smart Controls
Additional Paddle Colors
Device Conguration
Adding your device to a Z-Wave network
Once the hub is ready to add your smart fan control, press and
release the top or bottom button on the smart fan control to
add it in the network.
To remove and reset the device
Once the controller is ready to remove your device, press and
release the top or bottom button on the smart fan control to
remove it from the network.
To return to factory defaults
Quickly press the ON button 3 times, then press the OFF button
3times.TheLEDwillashON/OFF5timeswhencompleted
successfully
www.byjasco.com
13940
Black Paddle
46560
Add-On
Switch
24770
In-Wall Smart
Motion Switch
46564
In-Wall
Smart Dimmer
26932
In-Wall Smart
Motion Dimmer
55257
In-Wall
Smart Outlet
CAV
13943
Brown Paddle
13945
Ivory Paddle
Compliances,specicationsandavailabilityare
subject to change without notice
Distributed by Jasco Products Company LLC
10 E. Memorial Rd., Oklahoma City, OK
Questions? Contact our U.S.-based Consumer Care at
1-800-654-8483 between 7AM-8PM, M-F, Central Time.
©Jasco 2020
3
Certications & Compliances

Popular Controllers manuals by other brands

Omron CJ1W- ECT21 Operation manual

Omron

Omron CJ1W- ECT21 Operation manual

Total Control PCTC16F16S owner's manual

Total Control

Total Control PCTC16F16S owner's manual

Sony UPA-PC500 manual

Sony

Sony UPA-PC500 manual

Samson 2357-3 Mounting and operating instructions

Samson

Samson 2357-3 Mounting and operating instructions

Danfoss AK-PC 530 user guide

Danfoss

Danfoss AK-PC 530 user guide

Mitsubishi Electric MELSERVO MR-J4-B-LL Series instruction manual

Mitsubishi Electric

Mitsubishi Electric MELSERVO MR-J4-B-LL Series instruction manual

MOULDPRO Flosense 3.0 user guide

MOULDPRO

MOULDPRO Flosense 3.0 user guide

Ventair CU24V1 operation instruction

Ventair

Ventair CU24V1 operation instruction

Eaton S611 user manual

Eaton

Eaton S611 user manual

Aurora AR-WC-WH installation instructions

Aurora

Aurora AR-WC-WH installation instructions

Monacor img Stage Line FSC-3 manual

Monacor

Monacor img Stage Line FSC-3 manual

Atlas ECS-6RM owner's manual

Atlas

Atlas ECS-6RM owner's manual

SMC Networks LEFS Series Operation manual

SMC Networks

SMC Networks LEFS Series Operation manual

Galil DMC-2X00 user manual

Galil

Galil DMC-2X00 user manual

Flowserve Limitorque QX Maintenance and spare parts

Flowserve

Flowserve Limitorque QX Maintenance and spare parts

Ruida Technology BWK301R operating instructions

Ruida Technology

Ruida Technology BWK301R operating instructions

Samson 3374-10 Mounting and operating instructions

Samson

Samson 3374-10 Mounting and operating instructions

Armstrong IVS B Installation and operating instructions

Armstrong

Armstrong IVS B Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.