jbc KNE User manual

KNE
Nitrogen Regulator Kit for DDE, DME
and HDE Control Units
INSTRUCTION MANUAL

2
Packing List
The following items are included:
Nitrogen Flow
Regulator ........................ 1 unit
Ref. MNE-A
Nitrogen Handle ............ 1 unit
Ref. T245-NA
Stand ................................ 1 unit
Ref. DN-SF
Stand Cable ....... 1 unit
Ref. 0024227
Sponge ................. 1 u
Ref. CL6210
Nozzles .......... 2 units
Ref. B7244 (x1)
B7968 (x1)
Cartridge ......... 1 unit
Ref. C245903
Manual ................. 1 unit
Ref. 0020524
Module Cable .... 1 unit
Ref. 0024228
Sponge ............ 1 unit
Ref. S7034
This manual corresponds to the following reference:
KNE-B

3
Features
The KNE-A requires the GN-A generator or an available nitrogen supply at the operator´s bench.
To another
module
Use Ø 6 ± 0.15 mm
polyurethane tubing
MNE
Nitrogen Regulator
Module
GN
Nitrogen Generator
Module
DDE
DME
HDE
Control Unit
Stand Cable
Ref. 0024227
Module Cable
Ref. 0024228
DNS
Stand for Nitrogen
Handles Nitrogen Handle
Ref. T245-NA
T210-NA (Sold separately)
T470 -N A (For HDE Station.
Sold separately)
Handle
N2tube
Compressed
Air Inlet
or from N2 net
N2pressure range
supply 3 to 6 bar
6 bar MAX
Nitrogen supply tube
Electric circuit
www.jbctools.com

Peripherals Port 2-T245
17:14
Pedal None
Module None
Module
MNE_a
None
MENU
17:14 ?
Install
MODULE
Nitrogen
Postpone
4
1. After connecting the MNE, enter the
Peripherals Menu and select the port
you want to join to the module.
2. Select the module from the list of peripheral
connections. Remember your first
connection is denoted as “a”, the second
as “b”, etc. (e.g. MNE_a, MNE_b,...)
3. Press Menu or Back to save changes.
Initial Set up
When a new MNE is detected, a pop-up screen appears with instructions.
If no screen appears, click on the icon on the main bar and follow the steps.
Once set up, you can change the module settings by entering the Peripherals Menu.
For DDE and HDE Control Units
For DME Control Unit
For both Control Units
Appears only when
the installation is
postponed

5
Using nitrogen improves the quality of the solder joint as well as preventing tip oxidation.
The MNE is an electrovalve that manages nitrogen flow. It is controlled by the station which keeps gas
consumption to a minimum.
1. The nitrogen flow is automatically activated when the soldering iron is lifted from the stand.
2. The flow is interrupted when the tool is returned to the stand and the temperature drops for the tip
to go into the Sleep mode.
Use the P-005 Pedal to enable/disable the module. This pedal will work with any module or tool
regardless of the module to which it is connected.
Operation
Accessories
Recommended N2flow:
1-2 SLPM
N2 flow control
This light indicates when the
nitrogen is being supplied.
Pedal Connector
Pedal
Ref. P-005
www.jbctools.com

6
Clean periodically
Maintenance
Before carrying out maintenance or storage, always allow the equipment to cool.
- Use a damp cloth to clean the casing, the
stand and the tool. Alcohol can only be used
to clean the metal parts.
- Check periodically that the metal parts of
the tool/stand are clean so that the station
can check the tool status.
- Maintain tip surface clean and tinned prior to
storage in order to avoid tip oxidation. Rusty
and dirty surfaces reduce heat transfer to the
solder joint.
- Periodically check all cables and tube
connections.
- Replace any defective or damaged parts.
Use original JBC spare parts only.
- Repairs should only be performed by a
JBC authorized technical service.

7
Safety
- Only nitrogen can be used with this unit.
- Do not use the unit for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded before
use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode. The
soldering tip, the stand and the metal part of the tool may still be hot even when the station is
turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid flux coming into contact with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight as well as persons with reduced
physical, sensory or mental capabilities or lacking experience provided that they have been given
adequate supervision or instruction concerning use of the appliance and understand the hazards
involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
www.jbctools.com

This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
40 mm
50 mm
60 mm
80 mm
100 mm
130 mm 130 mm
para manuales - color gris
200 mm
300 mm
0031034-010323
KNE
Nitrogen Regulator Kit for DDE, DME & HDE Control Units
Ref.: KNE-B
- Weight: 3,7 kg / 8.2 lb
- Dimensions (MNE): 55 x 130 x 140 mm / 2 x 5.1 x 5.5 in
- Voltage (AC): 24V (from control unit)
- Power: 3W
- N2pressure range supply: 3-6 bar
- Maximum N2pressure: 6 bar
- N2flow regulation: 0.5 - 3 SLPM
- Recommended N2flow: 1-2 SLPM
- Ambient Operating Temperature: 10 - 50 ºC / 50 - 122 ºF
Complies with CE standards.
ESD Safe.
Specifications
This manual suits for next models
2
Table of contents
Other jbc Controllers manuals
Popular Controllers manuals by other brands

Abus
Abus wAppLoxx Pro Installation and operating instructions

Multiplex
Multiplex ROXXY PROcontrol Series manual

National Instruments
National Instruments Network Adapter NI PXIe-6672 installation guide

Neotec
Neotec NT7070 manual

HIMA
HIMA HIMatrix GEH 01 manual

STI
STI QuadSafe RM-4 Installation and operating manual