jbc DMPSE-QA User manual

4 Tools DME Station
with Electric Pump
Ref. DMPSE-QA
INSTRUCTION MANUAL
www.jbctools.com

DME Control Unit .......... 1 unit
Ref. DME-1A (120V)
DME-2A (230V)
DME-9A (100V)
Packing List
The following items are included:
Stand ................................2 units
Ref. AD-SE
Sponge ............. 1 unit
Ref. S0354
Metal Brush .... 1 unit
Ref. CL6217
Electric Desoldering
Module .............................. 1 unit
Ref. MSE-A
Brass Wool ...... 1 unit
Ref. CL6210
Desoldering
Iron ..................... 1 unit
Ref. DR560-A
Stand ................................. 1 unit
Ref. DR-SE
General Purpose
Handle ............... 1 unit
Ref. T245-A
Cotton Filter ......1 unit
Ref. 0781046
It contains 10 filters
ESD Tip Cleaner ............ 1 unit
Ref. CL8499
Precision Purpose
Handle ...............1 unit
Ref. T210-A
Stand ................................. 1 unit
Ref. AM-SA
Adjustable Micro
Tweezers ...........1 unit
Ref. AM120-A
2

4 Tools DME Station
with Electric Pump
Manual ................................1 unit
Ref. 0023136
Stand Cable ....................4 units
R ef. 0 0112 83
Module Cable ..................1 unit
R ef. 0 0 14 874
Power cord ........................1 unit
Ref. 0010569 (230V)
0013671 (100/120V)
INSTRUCTION MANUAL
Ref. DMPSE-QA
Suction Filter.....................1 unit
Ref. 0821830
Cleaning stick ..................1 unit
Ref. 0786640
Filter Box ............................1 unit
Ref. 0005966
It contains 50 filters
Union Flanges ................1 unit
R ef. 0 0113 5 6
Cartridge holder ........... 1 unit
Ref. SCH-A
DR560 Accessories
Ref. 0022819
Internal gasket .......... 1 unit
Ref. 0019208
It contains 2 gaskets
Filter Box .................... 1 unit
Ref. 0780840
It contains 10 filters
Spanner .................................................... 1 unit
Ref. 0780550
Glass solder collector ........................ 1 unit
Ref. 0812620
Metal solder
collector ...................... 1 unit
Ref. 0812630
Tip cleaning set .................................... 1 unit
Ref. 0965970
Long Tip Cleaning set ........................ 1 unit
Ref. 0965760
Pedal.................................. 1 unit
Ref. P-405
www.jbctools.com
3
www.jbctools.com

RJ12 connector for Robot or
Smart Fume Extractors
USB-B connector
Equipotential connection
Power Socket
RJ12 connector for PSE
RJ45 connector for LAN
Stand
Ref. DR-SE
Stand Cable
R ef. 0 0112 83
Connections
Stand
Ref. AD-SE
Desoldering Iron
Ref. DR560-A
General
Purpose
Handle
Ref. T245-A
4

Adjustable
Micro
Tweezers
Ref. AM120-A
Precision
Purpose
Handle
Ref. T210-A
Suction Filter
Ref. 0821830
Module Cable
R ef. 0 0 14 874
Electric Desoldering Module
Ref. MSE-A
To another peripheral
To Pedal
Ref. P-405
Stand
Ref. AD-SE
Stand
Ref. AM-SA
www.jbctools.com
5

350ºC
Port
3
Power
45%
Selected 350º
+
C245-003
MENU
17:14 ?
Features
USB-A connector
3.5” Color TFT Touch screen
Tilt the display
for easy reading
Main Switch
Work Screen
The DME-A offers an intuitive user interface which provides quick access to the station parameters.
Default PIN: 0105 Station Information
Help for each parameter
Power indicator
Shows the %
power delivered
by the tool.
Tool in use
Press on the
tool image
to see the
Ports Screen
Cartridge
in use
Introduce the
reference for
more precise
temperature
accuracity
Station Lock
PIN required
for unlocking
Station troubleshooting available on the product page at www.jbctools.com
Troubleshooting
6

17:14 ?
Station Tools Counters
Peripherals
Utilities Profiles Language Reset
Graphics
JBC Net
Update
Files
Registers total
and partial hours
for each port: work,
sleep, hibernation...
Multi-language
10 languages to choose from
Personalize
the station:
Station name, PIN
activation, Screen
settings, Robot
activation, Partial
resets...
Adjust tool settings for each port Join station ports with modules and pedals
Menu Screen
Press the station information button (?) to get information of the different features being displayed.
Utilities
Useful additional applications
that complement and
support your work.
Advanced functionalities
It provides detailed graphics of tip temperature and power delivery in real time during
solder joint formation for analysis purposes. This helps you decide how to adjust your
process or which tip to use to obtain the best quality soldering.
The first system to optimize traceability in soldering
- Get greater quality and control in your production
- Manage your whole soldering process remotely in real time
Station update
Download the JBC Update File from
www.jbctools.com/software.html
Insert the USB flash drive with the file downloaded to the station.
Export graphics
Insert a USB flash drive into the USB-A connector to save your soldering process in
csv format.
350ºC
Port
3
Power
45%
Selected 350º
+
C245-003
MENU
17:14 ?
Features
USB-A connector
3.5” Color TFT Touch screen
Tilt the display
for easy reading
Main Switch
Work Screen
The DME-A offers an intuitive user interface which provides quick access to the station parameters.
Default PIN: 0105 Station Information
Help for each parameter
Power indicator
Shows the %
power delivered
by the tool.
Tool in use
Press on the
tool image
to see the
Ports Screen
Cartridge
in use
Introduce the
reference for
more precise
temperature
accuracity
Station Lock
PIN required
for unlocking
Station troubleshooting available on the product page at www.jbctools.com
Troubleshooting
www.jbctools.com
7

Peripherals
17:14
Port 1 2 3 4
MS a
?
PERIPHERAL
Peripheral 1 plugged:
Electric Suction Module
Setup Postpone
Port 2
MENU
17:14 ?
Port 1
Port 3 Port 4
Hibern. Sleep
350º
C120-001
C560-001
Hibern.
C210-001
C560-903
Peripherals
17:14
Port 1 2 3 4
MS a
PD a
?
See the information for all ports in real time when pressing the tool image on the Work screen.
Simultaneous control of ports
Tool port
Press any port
to show on the
Work Screen
Tool Status
Tip temperature,
Sleep or
Hibernation
1. To configure your Electric Suction Module
press Setup in the popup window.
MSE / Pedal Initial Setup
After connecting the electric desoldering module (MSE-A), a popup window is
opened.
2. Select the module from the list of peripheral
connections.Remember your first connection
is denoted as “a”, the second being “b”, etc.
(e.g. MS_a, MS_b,...). Do the same with the
pedal (e.g. PD_a,...)
3. Select the port of the tool you want to link to
the peripheral.
4. Press Menu or Back to save changes.
Once set up, you can change the module
settings by entering the Peripherals Menu.
Peripherals
8

350ºC
Port
3
Power
45%
Selected 350º
+
C245-003
MENU
17:14 ?
Port
3
Port
3
Sleep
Tool in the stand
Actual Temp. 180ºC
Delay to hibernation: 29:30
MENU
17:14
?
3
Port
Hibernation
Actual Temp. 25ºC
MENU
17:14
?
3. Hibernation
Operation
The JBC Most Efficient Soldering System
Our revolutionary technology is able to recover tip temperature extremely quickly. It means the user
can work at a lower temperature and improve the quality of soldering. The tip temperature is further
reduced thanks to the Sleep and Hibernation modes which increase up to 5 times the life of the tip.
1. Work 2. Sleep
When the tool is lifted from
the stand the tip will heat up
to the selected temperature.
When the tool is in the stand,
the temperature falls to the
preset Sleep temperature.
After longer periods of
inactivity, the power is cut off
and the tool cools down to
room temperature.
Long period
in the stand
Tools Menu:
· Adjust temperature limits and
cartridge.
· Set temperature levels.
Tools Menu:
· Set Sleep temperature.
· Set Sleep delay.
(from 0 to 9 min or no Sleep)
Tools Menu:
· Set Hibernation delay.
(from 0 to 60 min or no
hibernation)
www.jbctools.com
9

Tools
?
17:14
T245 - port 3
Cartridge Adjust C245-003
Temperature adjust 0ºC
Temp. level set Off
Sleep delay 0 min.
USB flash drive is connected.
Station is controlled by a PC.
Station is controlled by a robot.
Station software update.
Press INFO to start the process.
System notifications
Warning.
Press INFO for failure description.
Error.
Press INFO for failure description,
the type of error and how to proceed.
Indicates there is a peripheral to be
installed.
Insert the cartridge model and the station will recognize its characteristics (size and shape) to provide
better temperature precission.
Cartridge Adjustment
The following icons will be displayed on the screen’s status bar.
After inserting
the cartridge,
introduce
the last 3
numbers of
its reference.
Desoldering process
Use a tip with a larger diameter than the pad to achieve maximum aspiration and thermal efficiency.
Place the tip over the
lead.
If any solder remains are left on a terminal after desoldering it, resolder it with fresh solder and
repeat the desoldering operation.
When the solder
melts, gently move
the tip in a circular
motion.
Press and hold the
tool button to start the
suction and continue
the movement
completing 3 o 4
circles.
3. Aspirating1. Placing 2. Rotating 4. Removing
Remove the tip
while maintaining
the suction to make
sure all the solder is
removed from the
joint.
If desoldering tips does not provide enough heat to desolder leads from ground planes, consider
using a preheater PCB.
10

Quick Tip Changer
1. Removing 2. Inserting 3. Fixing
Place the cartridge in the
extractor and pull the handle
to remove it.
Place the handle on top
of the new cartridge and
press down.
Use the holes to fix the
cartridge as follows:
A. For curved C210
B. For C245
C. For straight C210
D. cartridge Storage rack
Save time and change cartridges safely without switching the station off. Be careful, the cartridges
may be hot, when placing them in the storage rack.
Important: It is essential to insert the cartridge as far as the mark for a proper connection.
Mark
DR560 Changing Tips
1. Removing
Unscrew the tip using the spanner
supplied.
2. Inserting
Fit the new tip and tighten with the
spanner to make sure it is air tight.
The DR560 uses C560 tips.
Find the model that best suits your soldering needs in www.jbctools.com
Removing
Inserting
BC
A
D
www.jbctools.com
11

2. Removing
3. Rotational and Vertical Cartridge alignment
1. Unlocking
Mark
Slightly turn the wheels to align the cartridges
as required.
Once the alignment has been made, do not forget to fix the cartridges by tightening the fixing
knobs. A single turn of the knob is required to get them fixed.
Also make sure that the cartridges are in good condition so that the tweezers work properly.
!
The tail wheel guarantees that the cartridges
are equally aligned with vertical symmetry.
AM120 Changing cartridges
Unlock the fixing knobs. Place the cartridges in the extractor and pull
the tweezers to remove them.
Place the tweezers on top of the new cartridge
and slightly press down.
Use the grooves to insert the cartridges as
far as they stop.
*Important
It is essential to insert the cartridges as far as the mark for a proper connection.
12

Tip Cleaner
Improve thermal transfer by cleaning the tip after each solder joint.
Brass wool
Ref. CL6210
Splashguard
Ref. 0 017576
Very effective cleaning
method. It leaves a small
layer of solder on the tip to
prevent oxidation between
cleaning and rewetting.
It prevents splashing of
solder particles when
using the brass wool.
ESD Tip Wiper
Ref. CL0240
A temperature resistant
receptacle lets the
operator remove
excess solder by gentle
tapping or wiping.
Antisplash
Membrane
R ef. 0 0 17574
Prevents splashing
to maintain the
work area clean.
Non-slip base
Sponge
Ref. S0354
No need to hold the
base while cleaning tips.
The least harmful
cleaning method. Keep
the sponge damp with
distilled water when
working to avoid tip wear.
Tapping: Wiping:
Tap to remove excess solder. Use the slots to remove remaining particles.
www.jbctools.com
13

MSE Changing filters
- Keep the casing clean by using a damp cloth. Periodically check all cable and tube connections.
- Keep filters clean to ensure proper solder suction and replace them when necessary.
DR560 Maintenance
The intake tube should be periodically cleaned with the largest rod possible.
Important
DO NOT press the vacuum pump button while tinning the desoldering tip, as the fumes given off
by the flux would quickly block the ducts and the air filter.
Tip Care
Spare filters
Ref. 0005966
Cotton filters
Ref. 0781046
Suction filter
Ref. 0821830
O Ring
Ref. 0007717
Filter cover
Ref. 0004710
Important
Do not use sharp
pointed objects
to open the
suction filter.
14

Glass Solder Collector Cleaning
1. Removing the lid
3. Inserting the glass solder collector
Check filter
Lid
Check
internal joint
2. Cleaning
Check the filter and replace it if it is dirty or
damaged.
Remove the coil and clean the inside of the glass
solder collector with the cleaning stick.
The lid must be unscrewed with the DR560 in a
vertical position.
The glass solder collector must be inserted
with coil filter in place, positioned between the
2 lines marked.
Then the whole unit must be closed by
screwing the lid.
Marks
www.jbctools.com
15

Clean periodically
- Replace a blown fuse as follows:
- Replace any defective or damaged pieces. Use original JBC spare parts only.
- Repairs should only be performed by a JBC authorized technical service.
Maintenance
Before carrying out maintenance or storage, always allow the equipment to cool.
- Clean the station screen with a glass cleaner
or a damp cloth.
1. Pull off the fuse holder and remove the
fuse. If necessary use a tool to lever it off.
2. Press the new fuse into the fuse holder
and replace it in the station.
- Use a damp cloth to clean the casing and the
tool. Alcohol can only be used to clean the
metal parts.
- Periodically check that the metal parts of the
tool and stand are clean so that the station
can detect the tool status.
Fuse holder
Fuse holder
- Maintain tip surface clean and tinned prior to
storage in order to avoid tip oxidation. Rusty
and dirty surfaces reduce heat transfer to
the solder joint.
- Periodically check all cables and tubes.
Fuse
16

Safety
- Do not use the units for any purpose other than soldering or rework. Incorrect use may cause fire.
- The power cord must be plugged into approved bases. Be sure that it is properly grounded
before use. When unplugging it, hold the plug, not the wire.
- Do not work on electrically live parts.
- The tool should be placed in the stand when not in use in order to activate the sleep mode.
The soldering tip, the metal part of the tool and the stand may still be hot even when the station
is turned off. Handle with care, including when adjusting the stand position.
- Do not leave the appliance unattended when it is on.
- Do not cover the ventilation grills. Heat can cause inflamable products to ignite.
- Avoid the contact of flux with skin or eyes to prevent irritation.
- Be careful with the fumes produced when soldering.
- Keep your workplace clean and tidy. Wear appropriate protection glasses and gloves when
working to avoid personal harm.
- Utmost care must be taken with liquid tin waste which can cause burns.
- This appliance can be used by children over the age of eight and also persons with reduced
physical, sensory or mental capabilities or lack of experience provided that they have been given
adequate supervision or instruction concerning use of the appliance and understand the hazards
involved. Children must not play with the appliance.
- Maintenance must not be carried out by children unless supervised.
It is imperative to follow safety guidelines to prevent electric
shock, injury, fire or explosion.
www.jbctools.com
17

产品中有害物质的名称及含量
有害物质含量表
部件名称
有害物质
铅(Pb) 汞(Hg) 镉(Cd) 六价铬
(Cr(VI))
多溴联苯
(PBB)
多溴二苯醚
(PBDE)
烙铁头 O O O O O O
手柄 O O O O O O
电源线 O O O O O O
主机 O O O O O O
电源插座 O O O O O O
保险丝 O O O O O O
主开关 O O O O O O
电位连接 X O O O O O
变压器 O O O O O O
线路板 X O O O O O
O 表示该有害物质在该部件所有均质材料中的含量均在GB/T 26572 规定的限量要求以下。
X 表示该有害物质至少在该部件的某一均质材料中的含量超出GB/T 26572 规定的限量要求。
18

Specifications
4 Tools DME Station with Electric Pump
DMPSE-1QA /DMPSE-2QA / DMPSE-9QA
DME-1A 120V 50/60Hz. Input fuse: 6A. Output: 23.5V
DME-2A 230V 50/60Hz. Input fuse: 3.15A. Output: 23.5V
DME-9A 100V 50/60Hz. Input fuse: 8A. Output: 23.5V
- Temperature Range: 90 - 450 °C (190 - 840 ºF)
- Idle Temp. Stability (still air): ±1.5 ºC (±3 ºF)
- Output Peak Power: 160W per tool
- Tip to ground resistance: <2 ohms
- Tip to ground voltage: <2mV RMS
- Ambient Operating Temperature: 10 - 50 ºC (50 - 122 ºF)
- Connectors: RJ12 for RS232 (robot) and for PSE Power Supply
RJ45 connector for LAN (Ethernet)
USB-A / USB-B / Peripherals connectors
- Control Unit Weight: 4,6 kg (10 lb)
- Control Unit Dimensions: 148 x 120 x 232 mm (5.83 x 4.72 x 9.13 in)
MSE-A
- Ambient Operating Temperature: 10 - 50 ºC (50 - 122 ºF)
- Vacuum: 75% / 570 mmHg / 22.4 inHg
- Flow rate: 9 SLPM
- Peripheral Weight: 1,2 kg (2.7 lb)
- Peripheral Dimensions: 145 x 55 x 225 mm (5.71 x 2.17 x 8.86 in)
- Connector: Pedal for P-005
- Total Package: 480 x 370 x 380 mm / 14,71 kg
18.9 x 14.6 x 15.0 in / 32.43 lb
Complies with CE standards.
ESD protected.
www.jbctools.com
19

0023136-0120
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at the end of its life must
be collected and returned to an authorized recycling facility.
Warranty
JBC’s 2 year warranty covers this equipment against
all manufacturing defects, including the replacement
of defective parts and labour.
Warranty does not cover product wear or misuse.
In order for the warranty to be valid, equipment must
be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/
within 30 days of purchase.
www.jbctools.com
Table of contents
Other jbc Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

KPS
KPS DCM3500T instruction manual

PRECISION DIGITAL
PRECISION DIGITAL PD603 instruction manual

METREL
METREL EurotestIM instruction manual

ISCO
ISCO 4210 Installation and operation guide

Bosch
Bosch Professional GLM 30-23 Original instructions

Dwyer Instruments
Dwyer Instruments VP2 Specifications-installation and operating instructions