CONNECTINGTHE OVEN
Electric Supply PRESSURESIN EXCESS OF 0.5 P.S.I. CANDAMAGE
THE APPLIANCE PRESSURE REGULATOR AND
The appliance, wheninstalled, must be electrically OTHERGAS COMPONENTSINTHIS APPL(ANCEAND
groundedin accordancewithlocalcodesor,intheabsence CAN RESULTIN A GAS LEAK.
of local codes, with the NationalElectrical Code,
ANSI/NFPA70. a. A GAS CUTOFF VALVE SHOULD BE PUT IN AN
ACCESSIBLE LOCATION IN THE SUPPLY LINE
InCanadatheovenmustbeinstalledinaccordancewiththeAHEAD OF THE UNIT, FOR TURNINGON AND
current CSA Standard C22.1 - CanadianElectricalCode TURNING OFF GAS SUPPLY.If the unit is to be
Part 1.connected to house piping with flexible or semi-rigid
metalconnectors for gas appliances, CONNECTOR
ELECTRICALSUPPLYCONNECTION: NUTS MUST NOT BE CONNECTED DIRECTLYTO
The oven requires120volts, 60cycle alternatingcurrent PIPE THREADS. THE CONNECTOR MUST BE
from an outlet capable of supplying 15 amperes for INSTALLEDWITHADAPTORSPROVIDEDWITHTHE
non-combounits and 20 amperesfor combo units (with CONNECTOR.
microwave). b. Thehousepipingand/orovenconnectorusedtoconnec
the oven to the maingas supply must beclean,freeo
WARNING metalshavings,rust, dirt and liquids (oilor water). Dirt
ElectricalGroundingInstructions etc.inthesupplylinescancausefailureofthegasvalve,=
This applianceis equipped with a(three-prong) or controlsandctog burners.
groundingplugfor yourprotectionagainstshockhazard
andshouldbepluggeddirectlyintoa properlygrounded CAUTION:DONOTLIFT ORMOVETHEWALLOVEI
receptacle.Do not cut or removethegroundingprong BYTHE DOOR HANDLES.
fromthisplug,c.Turn off all pilotsandmaingas valveof other ga
appliances.
WARNING d.Turnoff maingas valveatmeter.
DISCONNECT ELECTRICAL SUPPLY
BEFORESERVICINGTHEAPPLIANCE.e.Beforeconnectingtheunit,applypipethreadeompour
approvedfor LPGto allthreads.
f.Connectunittogas supply.
GasSupply
Installationofthisovenmustconformwithlocalcodesor,in g. Turn on main gas valve at meter, and relight pilots
other gas appliances.
the absence of local codes, with the National FuelGas
Code,ANSIZ223.1-latestedition, h. Applyanon-corrosiveleakdetectionfluidtoalljointsa_
fittings in the gas connectionbetween the supply lil
InCanadatheovenmustbeinstalledinaccordancewiththe shut-off valve and therange. Includegas fittings a,
currentCGAStandardCAN/CGA-B149- InstallationCodes joints inthe range if connectionswere disturbedduri
for Gas BurningAppliancesand Equipment andor local installation.Checkfor leaks!bubblesappearingarou
codes, fittings and connectionswill indicate a leak. If a I_
appears,turn off supply linegas shut-offvalve,tight
GAS SUPPLY CONNECTION: connections,turnonthe supplylinegas shut offval,
A TRAINED SERVICEMAN OR GAS APPLIANCE andretestforieaks. Nevertest forgas leakswithano_;
INSTALLER MUST MAKE THE GAS SUPPLY flame.
CONNECTION.Leak testing ofthe appliance shall be
conducted by the installer according to the CAUTION: NEVER CHECK FOR LEAKS WlTI_
instructionsgivenin sectionh.FLAME.
NATURAL GAS SUPPLY LINE MUST HAVEAWHENLEAKCHECKISCOMPLETE,WIPEOFF
NATURAL GAS SERVICE REGULATOR. INLET RESIDUE.
PRESSURE TOTHIS APPLIANCESHOULD BE
REDUCED TO A MAXIMUM OF 14 INCHES WATER i,Adjustburnerairshuttertothewidestopeningthat
COLUMN (0,5 POUNDSPER SQUAREINCH (P,S,I,)not causetheflameto lift or blowoff theburnerw
LIQUEFIED PETROLEUM(L.P,)/PROPANE GAS cold.
SUPPLYLINE MUST HAVE AL.P. GAS PRESSURE
REGULATOR.INLET PRESSURETOTHIS APPLIANCE BEFORELIGHTING ANY BURNER, SEE THAT
SHOULD BE REDUCED TO A MAXIMUM OF 14 PACKING MATERIALS HAVE BEEN REMO\
INCHES WATER COLUMN (0.5 P.S.I.). INLET FROMTHE UNITS.
-5-