JingYan TLL90S User manual

2014 Dec 10
0
TLL90S Digital Protractor
User Guide

2014 Dec 10
1
Features:
1) TLL90S: High accuracy ±0.005°, high resolution 0.001°
2) Dual and Single axis with user friendly LCD display angle
3) Laser module installed for alignment
4) Rechargeable
5) V Shape Aluminum metal case for easy to fit at the corner or pipe.
6) 2 Side Magnetic base with milled surface
7) Audible alarming at settable angle range
8) Any angle measurement with gyro
9) USB / Bluetooth to pc connection need adapter
10) PLC Modbus RS485 connection with 6P6C socket, connect up to 255 unit in
one network
Specifications
Gravity Measurement Accuracy: 0 to 20°: ± (0.005°)
20 to 70°: ± (0.01°)
70 to 90°: ± (0.005°)
*After Calibrated
Measuring range: Single axis: 360°, Dual axis: ±40°
Resolution: 0.001°
Gyro Measurement 0.5°
Accuracy:
Gyro Measurement 0.1°
Accuracy:
Gyro Rotation Speed: <50°/s

2014 Dec 10
2
Display Response time: <0.6 second
Audio sound: 60dB @ 30cm
Zero offset drift angle per °C: 0.002° (typical)
Operating temperature: 0 to 50°C
Storage temperature: -10 to 60°C
User Interface: Mono-color LCD with backlight
Supply Power: Rechargeable Li-Polymer 3.7V
Charger port: 5V 500mA Mini type-B USB port
Power Consumption: Standby: 10uA, Operation: 20mA.
Standby Battery Life: 4000 hours
Operating Battery Life: 30 hours
Dimensions (in mm): 93(L) x 66(W) x 28(H)
Magnetic Base: affix at 2 face
Magnetic Force: N35
Weight: 120gram

2014 Dec 10
3
Button Functions
Function Descriptions
Button Normal Mode MENU Mode
This button turns the device ON.
Press and release will turn laser on/ off.
Long Press for 3 seconds will turn off.
Serves as the
escape key at
menu mode
When pressed, the current reading is set to zero;
subsequent measurements are relative to this
reading. The LCD will show the icon to indicate
the device is in zero mode.
Press and hold for 3 seconds to enable or disable
sound. The icon on LCD will be displaced
accordingly. The buzzer alarming could be set at
different accuracy level. Refer to section “Angle
Alarming”.
Serves as the
upward key
for option
selection
When pressed, the current value will freeze; the unit
icon flashes to indicate the reading is on hold.
Press and hold for 3 seconds to switch the
measurement mode Degree -> mm/M -> Gradient
%
Serves as the
downward
key at menu
mode

2014 Dec 10
4
Press and hold for 3 seconds to enter MENU mode,
for set mode options.
Serves as the
Set key.
Any angle measurement start button. Refer to
section “Any Angle”
Press and hold for 3 seconds to enter MENU mode,
for set mode options.
Serves as the
Set key.
LCD Icons Representations
Battery status indication icons
These icons indicate the battery level. There are 3 levels
representing empty, half and full.
In dual-axis mode, the LCD displays the direction of tilt graphically.
It will show as E bubble to display the direction of tilt
Degree mode. Flash when unit is in HOLD mode
mm/M, the height of one end for 1m long plate.
Gradient % mode. Flash when unit is in HOLD mode
Sound notification on.
Blank as off

2014 Dec 10
5
Show this logo as relative value is showing. When the Zero button
is pressed, the unit reset current angle to zero.
Direction of tilt icons, show the tilt angle direction
Dual-Axis Mode. Both the X and Y axis angle will be showed. Dual
axis mode measures inclination up to +-40 degree for each axis
before it automatically switch to single axis mode.
Single Axis Mode. Measure slope up to +-90 degree.
The triangle icon indicates the direction of tilt with respect to the
bottom right corner of the unit.
Battery Charging
It has a built in Lithium Ion rechargeable battery. A standard charger is supplied that
the input voltage is 110V to 240V AC, 50/60Hz, and the output is 5V DC, 500mA.
The charger operating procedure is list below:
1) Plug the Charger into AC socket, the RED indicator on the charger should
turned ON,
2) Plug the USB charging cable to the Charger,
3) Insert the other end of the USB cable to the unit,
4) The battery icon on the LCD blinks to indicate charging in process. Upon
charging complete, the icon stops blinking.
5) The charging time is approx. 3 hours.
The unit could also be charged by connecting the USB cable to the unit and a

2014 Dec 10
6
computer’s USB port. This has the same effect when charging the unit with the
provided adaptor.
Note: When the unit is turned OFF, and plug in the USB charge cable, the LCD will
no show anything, it is NORMAL. Once the unit is turned ON, the battery icon should
flash indicating the unit is in charging mode.
Relative/ Absolute Measurement
Relative Measurement
LCD Icon:
Absolute Measurement
LCD Icon: Blank
Relative and Absolute Mode Switching:
1 Press and release the “ZERO” key to set the relative measurement zero point
2 Press and release the “ZERO” key to cancel the relative zero point and back
to absolute measurement mode.
Hold Function
Holding Mode:
LCD Icon blinking:
Holding function:
1. Press and release the “HOLD” key to activate holding function, digit will freeze.
2. Press and release the “HOLD” key to cancel the holding function.

2014 Dec 10
7
Auto Power Off
For no movement in 30 minutes, the unit will power off.
Or we can set to never sleep mode at below instruction.
Power auto off setting:
1. Press and hold “SET” / “ANGLE” key and enter MENU mode
2. Select “POWER” by “ZERO” and “HOLD” key, press “SET” key to enter Power
mode
3. Scroll “NEVER” or “30MIN” by “ON/OFF” and “HOLD” key
4. Press “SET” key to confirm NEVER or 30MIN (30 minutes) sleep
Restore Factory Setting
When you find that the unit is abnormal, you can restore the unit to factory setting.
All tilt mode calibration setting will be restored to factory setting.
*Not suggest restore to factory setting in normal status, for accuracy drift, please
follow Calibration. After factory set, please redo calibration to ensure the accuracy.
Restore to factory setting:
1. Press and hold “SET” / “ANGLE” key and enter MENU mode
2. Select “FACTORY SET” by “ZERO” and “HOLD” key, press “SET” key to enter
FACTORY SET mode
3. Scroll “YES” or “NO” by “ZERO” and “HOLD” key
4. Press “SET” key to confirm
Angle Alarming
Alarming Mode:
LCD Icon:
BUZZER
>SINGLE : 0 0 . 0 0 0
DUAL. X: 0 0 . 0 0 0
DUAL. Y: 0 0 . 0 0 0
RANGE : 0 0 . 5 0 0
ACTIVE : IN OUT

2014 Dec 10
8
Alarming Angle setting:
1. Press and hold “SET” / “ANGLE” key and enter MENU mode
2. Select “BUZZER” by “ZERO” and “HOLD” key, press “SET” or “ANGLE” key to
enter BUZZER setting
Press and hold “ZERO” and “HOLD” key for fast scrolling the digit.
3. Press “SET” or “ANGLE” to enter setting value
SINGLE Vertical / Single axis mode alarming angle (Degree)
DUAL.X Horizontal/ Dual axis mode X axis alarming angle (Degree)
DUAL.Y Horizontal/ Dual axis mode Y axis alarming angle (Degree)
RANGE The range (Degree)that will trigger the audible alarming
For example: SINGLE. set to 20.000
RANGE set to 01.000
While the unit is in +19° to +21°or -19 ° to -21°, the unit will alarm
ACTIVE IN or OUT to set the alarm will alarm in of range or out of range
Calibration
Calibrate the unit, once you found that there is accuracy drift on the unit. You can
verify the accuracy at below step:

2014 Dec 10
9
At Step1, you measured X and Y value, X1 and Y1
At Step2, you measured X2 and Y2, in theory X1=-X2, Y1=-Y2.
If the error is too large, you can enter calibration mode to eliminate the error
Accuracy drift is causing by large ambient temperature change (5 to 10 Degree
Celsius) or the unit has been dropped.
Calibration Procedure:
Step 1: Press and hold the “Angle/Set” key enter Menu mode. Select “Calibration”
mode, press “SET”. Place the unit on a flat table (no need perfect level table)
LCD display “CALIBRATE DUAL AXIS PRESS SET”, press “SET” and buzzer will
beep; wait until the beep sound stop. While the buzzer is beeping keep the unit
stable.
Step 2: Then rotate the unit 180 degree with the other side against the same place.
Press the Set button again, and wait for the beep finished.

2014 Dec 10
10
Step 3: LCD display “CALIBRATE HORIZONTAL PRESS SET”. Place the unit
horizontal like the picture “STEP 3” and then press “SET”, wait until the beep sound
stop.
Step 4: Then rotate the unit 180 degree at the same place. Press the “ZERO” button
again, and wait for the beep finished.
Step 5: LCD display “CALIBRATE VERTICAL PRESS SET”, mention that the
ON/OFF Key at upper side, hold on a flat wall. And then press “SET” Key. Wait for
the “Beep” sound stop.
Step 6: Then rotate the unit 180 degree with the other side against the same place
of wall (ON/OFF Key at upper side). Press the Set button again, and wait for the
beep finished. Now, the LCD should go back to the selection menu. The calibration
is done, by selecting “Back” to go back for normal operation

2014 Dec 10
11
ANY ANGLE measurement:
Any angle measurement is using gyro technique.
You can measure the angle between two faces, not only in earth gravity direction.
1) Press Angle key at the first face, and then rotate slowly and must keep the
rotation axis to another testing face
2) It will then show the angle once you not move the unit.
The rotation axis:

2014 Dec 10
12
Any Angle Measurement Method:
Example: Measure angle between two wooden walls is 88.2°

2014 Dec 10
13
Calibrate Gyro
1) Place Unit At Flat Table And then Press Set
2) Flip 360 degree in clockwise and then press set
Please rotate slowly to increase the accuracy
3) Place unit at flat table and then press set

2014 Dec 10
14
4) Flip 360 degree counter clockwise and then press set
Please rotate slowly to increase the accuracy
Data Communication
Communication is in MODBUS format:
Baud Rate 9600
Can connect up to 255 TLL90 in the same RS485 network
Choose the output port
1. Press and hold “Angle/Set” key and enter MENU mode

2014 Dec 10
15
2. Select “POWER” by “ZERO” and “HOLD” key, press “SET” key to enter Data
communication
3. Scroll “USB” or “RS485” by “Zero” and “HOLD” key
4. Press “SET” key to confirm which port to communicate
Set the address
1. Press and hold “Angle/Set” key and enter MENU mode
2. Select “POWER” by “ZERO” and “HOLD” key, press “SET” key to enter Data
communication
3. Set the device address by “Zero” and “HOLD” key
4. Press “SET” key to confirm
RS485 is 6P6C socket
Pin1&2 is power DC 6 to 9V
Pin 3 is RS485 A
Pin 4 is RS485 B
Pin 5&6 is ground.
USB port:
It is not standard USB protocol, but serial port
Pin 1 is VBUS to provide 5VDC
Pin 2 is D-, RS232 TX transmission pin in cmos 3.3V level
Pin 3 is D+, RS232 RX transmission pin in cmos 3.3V level
Pin 4 is not connected
Pin 5 is GND ground
** can order a RS232 adapter to convert to USB serial port and connect to computer.

2014 Dec 10
16
Modbus protocol of communication
Sent to read (16 bit) (example to modify display mode)
Hex Dec Purpose
0x01 1 Address of device
0x03 3 Function read
0x00 0 High Byte of register address (100 Display mode)
0x66 102 Low Byte of register address (100 Display mode)
0x00 0 High Byte of number of register to read (Always 0)
0x02 2 Low Byte of number of 16 bit register to read
0x24 36 Low Byte of CRC
0x14 20 High Byte of CRC
Sent to write (16bit) (example to set measuring mode)
Hex Dec Purpose
0x01 1 Address of device
0x06 6 Function write
0x01 1 High Byte of register address (300 Measuring mode)
0x2C 44 Low Byte of register address (300 Measuring mode)
0x00 0 High Byte of number of register to write
0x01 1 Low Byte of number of register to write
0x3F 63 Low Byte of CRC
0x88 136 High Byte of CRC

2014 Dec 10
17
Register to read
Address Purpose (16 bit data)
0 Single Axis
0x0064 Display
Tilt Mode 1 Dual Axis
0 Degree
1 mm/M
0x0065 Measuring
format 2 Gradient (Slope)
0x0066 High 16 bit
0x0067 Low 16 bit
X axis/ Single axis tilt angle: 32 bit signed integer 2’s
complement 00001= 00.001 degree
0x0068 High 16 bit
0x0069 Low 16 bit
Y axis tilt angle: 32 bit signed integer 2’s complement
00001= 00.001 degree
0x006A High 16 bit
0x006B Low 16 bit
Gyro value: 32 bit signed integer 2’s complement
0001= 000.1 Degree
0x006C High 16 bit
0x006D Low 16 bit Sensor’s temperature 00001=000.01 degree Celsius
Register to Write
Address Purpose (16 bit data)
0 Tilt angle reading mode
0x12C Measuring
Mode 1 Gyro measuring mode
0 Degree
1 mm/M
0x12D Measuring
Format 2 Gradient (Slope)

2014 Dec 10
18
TLL90S 双轴激光水平用说明书
产品特点:
1)高精度 ±0.005°, 高分辨率 0.001°
2) 可测单轴、双轴倾斜角度,大屏 LCD 清晰显示角度。
3)激光打标

2014 Dec 10
19
4) 充电功能
5) 外壳 V 槽设计可以轻松放置在拐角和圆管上。
6) 磁铁吸附功能
7) 可对指定角度设定蜂鸣报警
8) 可任意物体之间的角度
9) 通过 USB,蓝牙和电脑连接
10)可以用 MODBUS 485 模式连接 PLC,可同时连接 255 台 TLL-90S
产品规格
产品精度: 0 至 20°: ± (0.005°)
20 至 70°: ± (0.01°)
70 至 90°: ± (0.005°)
*校正之后的精度*
测量范围: 单轴模式: 360°,
双轴模式: ±40°
分辨率: 0.001°
任意物体之间角度测量精度: 0.5°
任意物体之间角度测量分辨率: 0.1°
陀螺仪旋转速度: <50°/秒
响应时间: <0.7 秒
蜂鸣音量: 60dB @ 30cm
水平仪零度的时候每°C 角度偏差: 0.002° (一般状态)
Other manuals for TLL90S
1
Table of contents
Other JingYan Measuring Instrument manuals