manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Johansson
  6. •
  7. Amplifier
  8. •
  9. Johansson 7708 User manual

Johansson 7708 User manual

Other Johansson Amplifier manuals

Johansson 7411 User manual

Johansson

Johansson 7411 User manual

Johansson 7750 User manual

Johansson

Johansson 7750 User manual

Johansson 9650 User manual

Johansson

Johansson 9650 User manual

Johansson Profiler Lite 6601 User manual

Johansson

Johansson Profiler Lite 6601 User manual

Johansson 7412 User manual

Johansson

Johansson 7412 User manual

Johansson 9657 User manual

Johansson

Johansson 9657 User manual

Johansson 7717 User manual

Johansson

Johansson 7717 User manual

Johansson 7720L User manual

Johansson

Johansson 7720L User manual

Johansson Profino 6610 User manual

Johansson

Johansson Profino 6610 User manual

Johansson 7412 User manual

Johansson

Johansson 7412 User manual

Johansson Profino Revolution Lite User manual

Johansson

Johansson Profino Revolution Lite User manual

Johansson 7712 User manual

Johansson

Johansson 7712 User manual

Johansson 9654 User manual

Johansson

Johansson 9654 User manual

Johansson 9658 User manual

Johansson

Johansson 9658 User manual

Johansson 7781 User manual

Johansson

Johansson 7781 User manual

Johansson 7750 User manual

Johansson

Johansson 7750 User manual

Johansson 6600 User manual

Johansson

Johansson 6600 User manual

Johansson 7710 User manual

Johansson

Johansson 7710 User manual

Johansson Super Profiler 6630 User manual

Johansson

Johansson Super Profiler 6630 User manual

Johansson Profiler SAT User manual

Johansson

Johansson Profiler SAT User manual

Popular Amplifier manuals by other brands

Magnat Audio EDITION FOUR Owner's manual/warranty document

Magnat Audio

Magnat Audio EDITION FOUR Owner's manual/warranty document

Inter-m PA-2000A Operation manual

Inter-m

Inter-m PA-2000A Operation manual

Yamaha TX6n owner's manual

Yamaha

Yamaha TX6n owner's manual

Peavey TNT 150 user guide

Peavey

Peavey TNT 150 user guide

Bosch LBB 1903/10 Installation and user instructions

Bosch

Bosch LBB 1903/10 Installation and user instructions

Avocent Emerge DA1200D Installer/user guide

Avocent

Avocent Emerge DA1200D Installer/user guide

Redgum RGi35 operating instructions

Redgum

Redgum RGi35 operating instructions

Cambridge Audio AXA25 user manual

Cambridge Audio

Cambridge Audio AXA25 user manual

Alpine MRP-M200 owner's manual

Alpine

Alpine MRP-M200 owner's manual

Technical Pro H1502UrBT user manual

Technical Pro

Technical Pro H1502UrBT user manual

FMS EMGZ307 operating manual

FMS

FMS EMGZ307 operating manual

Racal Instruments 5601 user manual

Racal Instruments

Racal Instruments 5601 user manual

Valcom V-1094A Technical specifications

Valcom

Valcom V-1094A Technical specifications

Cambridge Audio 851D user manual

Cambridge Audio

Cambridge Audio 851D user manual

QSC 3800 Specifications

QSC

QSC 3800 Specifications

NAD C300 owner's manual

NAD

NAD C300 owner's manual

Rotel RMB-1077 owner's manual

Rotel

Rotel RMB-1077 owner's manual

Peavey Monitor 300 Series operating guide

Peavey

Peavey Monitor 300 Series operating guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

Consignes de sécurité
Safety Instructions
Technical Specifications
Caractéristiques techniques
2 outputs indoor amplifier
Amplificateur d'intérieur 2 sorties
Technical Specifications
Frankrijklaan 27, B-8970 Poperinge, Belgium
TEL +32 57 33 33 63 FAX +32 57 33 45 24
www.johansson.be e-mail: [email protected]
R
Instruction Manual / Mode d'emploi
R
Caractéristiques techniques
Products are subject to change without notice.
REF.: 7708
Safety Instructions
Consignes de sécurité
Read carefully these instructions before connecting
the unit.
The operating voltage is indicated on the nameplate of
the housing.
To prevent fire, short circuit, shock hazard : Do not expose
the unit to rain or moisture.
Install the unit in a dry location without infiltration or
condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on
the apparatus.
If any liquid should accidentally fall into the cabinet,
disconnect the power plug.
Refer to qualified technician before it's further operation.
To avoid any risk of overheating:
Install the unit in a well aery location and keep a minimum
distance of 10 cm around
the apparatus for sufficient ventilation.
Do not place any items such as newspapers, table-cloths,
curtains ... on the unit that
might cover the ventilation holes.
The unit must not be exposed to any source of heat (sun,
heater,...).
Do not place any naked flame sources, such as lighted
candles, on the apparatus.
Do not install the product in a dusty place. Pull out power
plug to make the different
connections of cables. To avoid electrical shock, do not
open the housing.
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualified
personnel.
Lire attentivement ces instructions avant le branchement
au réseau électrique.
La plaque signalétique sur le produit indiquela tension de
fonctionnement.
Afin d'éviter tout risque de court-circuit ou de choc
électrique :
Ne pas exposer cet appareil à la pluie ou à l'humidité.
Installer le produit dans un lieu sec, sans infiltration ni
condensation d'eau.
Ne pas l'exposer à des égouttements ou à des
éclaboussures d'eau.
Aucun objet rempli de liquide tel qu'un vase... ne doit être
posé sur l'appareil.
Si un liquide tombe accidentellement dans le boîtier,
débrancher le cordon secteur.
S'adresser à un technicien qualifié avant sa remise en service.
Afin d'éviter tout risque de surchauffe:
Installer le produit dans un endroit bien ventilé et laisser une
distance minimale de 10 cm autour de l'appareil pour une
aération suffisante.
Ne mettre aucun objet sur le produit tel que journal, rideau,
nappe ...qui puisse couvrir ou boucher les ouvertures
d'aération.
Ne pas exposer le produit à une source de chaleur (soleil,
chauffage,...).
Ne pas placer sur l'appareil des sources de flammes nues
telles que des bougies allumées.
L'appareil ne doit pasétre installéen milieu poussiéreux.
Ne brancher la prise de courant qu'après avoir réalisé le
raccordement de tous les câbles.
Afin d'éviter tout risque de choc électrique, ne pas ouvrir
le boîtier.
Entretien :
Utiliser uniquement un chiffon doux et sec pour
nettoyer le boîtier.
Ne pas utiliser de solvant.
Réparation :
Toute intervention ou réparation doit être
effectuée par un personnel qualifié.
Les spécifications peuvent être modifiées sans préavis. 03/04
- Frequency range :
- Adjustable gain :
- Noise figure :
- Max. output level (DIN 45004 B) :
- Return loss (input and outputs) :
- Isolation :
- Number of outputs :
- Connectors :
- Power :
- Dimensions :
40-300 + 470-862 MHz
VHF : 0-12 dB
UHF : 7-22 dB
VHF : 5.5 dB
UHF : 5.0 dB
100 dBµV
10 dB min.
VHF : 10 dB min.
UHF : 15 dB min.
2
Type "F" fem.
230 V~ ± 10%, 50 Hz, 9 VA
138 x 102 x 48 mm.
- Fréquences :
- Gain réglable :
- Facteur de bruit :
- Niveau de sortie max (DIN 45004 B) :
- Affaiblissement de réflexion (entrée et sorties) :
- Réjection entre sorties :
- Nombre de sorties :
- Connecteurs :
- Alimentation :
- Dimensions :
40-300 + 470-862 MHz
VHF : 0-12 dB
UHF : 7-22 dB
VHF : 5.5 dB
UHF : 5.0 dB
100 dBµV
10 dB min.
VHF : 10 dB min.
UHF : 15 dB min.
2
Type "F" fem.
230 V~ ± 10%, 50 Hz, 9 VA
138 x 102 x 48 mm.
UNITRON n.v.
Application
Application
Mounting
Mounting Montage
Montage
7708
IN
INDOOR AMPLIFIER
OUT 1
OUT 2
40-300 MHz :0- 12 dB
470-862 MHz:7-22 dB
230 V~/ 50 Hz
Pmax. : 9 VA
Do not open. Live parts inside.
-
UHF
VHF
ATTENTION !
Ne pas ouvrir. Ri squ ede choc électrique.
+
-
+
1000
(6)
(7)
(5)
(4)
(1)
(2) (3)
This VHF-UHF indoor amplifier is used to
compensate losses of cable length and splitter.
2 attenuators allow equalizing signal
between UHF and VHF.
7708
IN
INDOOR AMPLIFIER
OUT 1 OU T 2
40-300 MHz : 0-12 dB
470-862MHz : 7-22 dB
230V~ /50 Hz
Pmax. :9 VA
Donot open.Live parts inside.
-
UHF
VHF
ATTENTION !
Nepas ouvrir. Risquede chocélectrique.
+
-
+
1000
R
7708
TV
Branchement d'une seule sortie, boucler la seconde
sortie avec 75 Ohms.
NOTE : Remarque :
Use this template to
mount the screws. Utiliser ce gabarit pour le
montage des vis de fixation.
45 mm.
TV
Cet amplificateur d'intérieur VHF-UHF s'utilise pour
compenser les pertes dues à la répartition et aux
longueurs de câble.
2 atténuateurs permettent d'équilibrer les signaux UHF et VHF.
When connecting one output only, load the
second output with 75 Ohms.
Connections
Connections
Branchements
Branchements
7708
VHF-UHF input signal
Outputs to TV
VHF gain adjustment
UHF gain adjustment
Mains power
LED
(1)
(2) (3)
(4)
(5)
(6)
(7)
Entrée signal VHF-UHF
Sorties vers TV
Réglage gain VHF
Réglage gain UHF
Alimentation secteur
Témoin lumineux
=
=
=
=
=
=
(1)
(2) (3)
(4)
(5)
(6)
(7)
=
=
=
=
=
=