CONDITIONS OF
W
ARRANTY
PERIOD OF
W
ARRANTY
Unitron N.V. warrants the product as being free from defects in material and
workmanship for a period of 24 months starting from the date of production indicated
on it. See note below.
If during this period of warranty the product proves defective, under normal use, due to
defective materials or workmanship, Unitron N.V, at its sole option, will repair or replace
the product. Return the product to your local dealer for reparation.
THE WARRANTY IS APPLIED ONLY
FOR DEFECTS
IN MATERIAL AND WORKMANSHIP
AND DOES NOT COVER
DAMAGE RESULTING FROM
•Misuse or use of the product out of its specifications.
• Installation or use in a manner inconsistent with the technical or safety
Standards in force in the country where the product is used.
• Use of non-suitable accessories (power supply, adapters ...).
• Installation in a defect system.
• External cause beyond the control of Unitron N.V. such as drop, accidents,
lightning, water, fire, improper ventilation…
THE WARRANTY IS NOT APPLIED IF
• Production date or serial number on the product is illegible, altered,
deleted or removed.
• The product has been opened or repaired by a non-authorised person.
NOTE
Date ofproduction is YYWW
format,
example
1425
=
year
2014 –week 25.
For
the serial number barcodes, the date corresponds to the 4 firstnumbers.
5051ETH / 5051UKETH
INPUT
VOL
TAGE
VA
C
90
to 264
OUTPUT
VOL
TAGE
VDC
15
OUTPUT
CURRENT
A
20
OUTPUT POWER
W
300
FAN ALARM CONTACT
-
2A @ 30VDC
TEMPERA
TURE
°C
0
to 40
DIMENSIONS
-
5 RU x 12 TE x 330
mm
Specifications are subject to change without notice 06/14
user
manual
5051ETH
5051UKETH
15 VDC Power Supply
for
Digital Modular
Headends
FAN ALARM CONTACT
NO = Normal open contact, is open in alarm condition
Common = common contact
NC = Normal closed contact, is closed in alarm condition
GREEN LED = OFF in alarm condition
Following conditions generate Alarm :
-Unit not powered
-Unit powered but power supply fail
-Unit powered but Fan is stopped, electrically or mechanically
SAFETY INSTRUCTIONS
To prevent fire, short circuit or shock hazard:
-Do not expose the unit to rain or moisture.
-Install the unit in a dry location without infiltration or condensation of water.
-Do not expose it to dripping or splashing.
-Do not place objects filled with liquids, such as vases, on the apparatus.
-If any liquid should accidentally fall into the cabinet, disconnect the power.
To avoid any risk of overheating:
-Install the unit in a well aery location and keep a minimum distance of 15 cm
around the apparatus for sufficient ventilation.
-Do not place any items such as newspapers, table-cloths, curtains,…on the
unit that might cover the ventilation holes.
-The unit must not be exposed to any source of heat (sun, heater,...).
-Do not place any naked flame sources, such as lighted candles, on the apparatus.
-Do not install the product in a dusty place.
-Use the apparatus only in moderate climates (not in tropical climates).
-Respect the minimum and maximum temperature specifications.
To avoid any risk of electrical shocks:
-Operation is permitted only on sockets with an earthing contact and protective
earth connection.
-Intentionally breaking the protective earth connection either in feed line or in the
product itself is not permitted
-The mains plug shall remain readily operable.
-Pull out power plug to make the different connections of cables or replace fuses.
-To avoid electrical shock, do not open the housing of adapter.
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
For repairing and servicing refer to qualified personnel.
Only original parts may be used for replacing parts relevant to safety.(e.g. fuses)
johansson
johansson

This manual suits for next models

1

Other Johansson Power Supply manuals

Johansson 9933 User manual

Johansson

Johansson 9933 User manual

Johansson 9933 User manual

Johansson

Johansson 9933 User manual

Johansson 9933UK User manual

Johansson

Johansson 9933UK User manual

Popular Power Supply manuals by other brands

Fisher Scientific Midi300V/4 instruction manual

Fisher Scientific

Fisher Scientific Midi300V/4 instruction manual

METREL MA 4852 instruction manual

METREL

METREL MA 4852 instruction manual

Vimar ELVOX 6837 instruction manual

Vimar

Vimar ELVOX 6837 instruction manual

Fortis SG200 user manual

Fortis

Fortis SG200 user manual

Gallagher S10 instructions

Gallagher

Gallagher S10 instructions

Teledyne Power Pod 400 instruction manual

Teledyne

Teledyne Power Pod 400 instruction manual

Altronics Maximal11EV installation guide

Altronics

Altronics Maximal11EV installation guide

Thermaltake Litepower Series user manual

Thermaltake

Thermaltake Litepower Series user manual

Elenco Electronics XP-625 instruction manual

Elenco Electronics

Elenco Electronics XP-625 instruction manual

Alpha Technologies CXPS-E101 manual

Alpha Technologies

Alpha Technologies CXPS-E101 manual

ELC ALR3220 user manual

ELC

ELC ALR3220 user manual

Matsusada Precision DOEF Series instruction manual

Matsusada Precision

Matsusada Precision DOEF Series instruction manual

Mastech HY1503D user manual

Mastech

Mastech HY1503D user manual

Pulsar PSD480250 manual

Pulsar

Pulsar PSD480250 manual

SYBRILLO BATTERY user guide

SYBRILLO

SYBRILLO BATTERY user guide

Sharkoon Silent Storm SHA460-135A user manual

Sharkoon

Sharkoon Silent Storm SHA460-135A user manual

Altronix ALTV248Hi220 installation guide

Altronix

Altronix ALTV248Hi220 installation guide

Amada DC25 Operation manual

Amada

Amada DC25 Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.