UNITRON n.v., Frankrijklaan 27, B-8970 Poperinge, Belgium
TEL +32 57 33 33 63 FAX +32 57 33 45 24
www.johansson.be E-mail : sales@johansson.be
R
Products are subject to change without notice. 02/06
16 - 64 outlets
Profiler Lite
45 dB
9934 (4 x SAT)
9935 (4 x SAT + 1 Terr)
TV
TV
The power supply is connected to
whichever multiswitch and is used to feed
the LNBs and the amplifiers ref. 9934 / 9935.
Maximum delivered current is 2000 mA.
In order to avoid overload, check the total
consumption of the installation :
LNBs , ref. 9934 = 400 mA,
ref. 9935 = 500 mA ….
Connect the power supply to mains after
all coaxial cables have been connected.
Current is present on all 4 SAT trunk lines.
Each multiswitch and amplifier has a
LED power indicator.
or
V
H
V
H
V
H
V
H
Low Band
Low Band
High Ba nd
High Ba nd
V
H
V
H
V
H
V
H
LowBa nd
LowB and
High Band
HighBand
V
H
V
H
V
H
V
H
Low Ban d
Low Ban d
High Band
High Band
V
H
V
H
Low Ban d High Band
5 x 4 / 6 / 8 / 12 / 16
-20 dB
5 x 4 / 6 / 8 / 12 / 16
- 15 dB
5 x 4 / 6 / 8 / 12 / 16
- 10 dB
5 x 4 / 6 / 8 / 12 / 16
- 5 dB
LNB
Quattro
15 V
15 V
15 V
15 V
Power Supply
REF. 9933UK
Amplifier
Power Supply 15V / 2.0 A
R
Instruction Manual
REF. : 9933UK
- AC input :
- DC output :
- Max. output current :
- Connector :
- Power :
- Security :
- Operating temperature range :
- Dimensions :
240 V~ / 50 Hz
2.0 A
Jack Ø2.1 female
50 VA
Short circuit protected
Double isolated
-5° to +50° C
176 x 71 x 47 mm.
Read carefully these instructions before connecting the unit.
The operating voltage is indicated on the nameplate of the housing.
To prevent fire, short circuit, shock hazard : Do not expose the unit to rain or moisture.
Install the unit in a dry location without infiltration or condensation of water.
Do not expose it to dripping or splashing.
Do not place objects filled with liquids, such as vases, on the apparatus.
If any liquid should accidentally fall into the cabinet, disconnect the power plug.
Refer to qualified technician before it's further operation.
To avoid any risk of overheating: Install the unit in a well aery location and keep a minimum
distance of 15 cm around the apparatus for sufficient ventilation.
The unit must not be exposed to any source of heat (sun, heater,...).
Do not place any naked flame sources, such as lighted candles, on the apparatus.
Do not install the product in a dusty place. Pull out power plug to make the different
connections of cables.
To avoid electrical shock, do not open the housing.
Cleaning :
Only use a dry soft cloth to clean the cabinet.
Do not use solvent.
Servicing :
For repairing and servicing refer to qualified personnel.
15 V
Technical specifications
Safety instructions
LED