3
FOR SERVICE ASSISTANCE, CALL 800-433-0708 OR VISIT JOHNDOW.COM
ASSEMBLY INSTRUCTIONS
1. Remove screen from JDI-17PLP. Flip drain over.
2. Remove and discard the hose and ball valve from
bottom port of drain. Keep hose clamp.
3. Mount electric pump [1] to bracket, making sure
inlet port is facing drain port, using the 1/4” hex
nuts [2] and 1/4” bolts [3] with 7/16” wrench
(Figure 1).
4. Check size of drain port:
a. If drain port is 1/2”: Attach 1/2” ID x 8” drain
hose [4] to port. Slip 1/2” hose clamp [6] and
hose clamp from step 2 over hose. Attach 3/8”
hose barb tting [5] to pump inlet port,
tightening with adjustable wrench. Tighten
hose clamps on each end of hose with at
head screwdriver.
b. If drain port is 1”: Attach 1” ID x 9” hose [7]
tting to pump inlet port, tighten with adjust-
able wrench (Figure 2). Place hose clamp
from step 2 onto hose. Insert the hose over
the drain port. Tighten clamp with at head
screwdriver.
5. Attach 3/4” GHT x 3/4” NPT tting [8] to pump
outlet port. Tighten with adjustable wrench.
6. Attach 90° barb tting [9], turn until barb is tight
and pointing left (Figure 3).
7. Attach 19mm ID x 28cm hose [10] to barb using a
1” hose clamp [11] and at head screwdriver.
8. Flip drain back over and replace screen onto
drain. Wrap pump cord around cord wrap bracket
(Figure 4).
9. Attach 3/4” ball valve [12] to hose tting. Tighten
with adjustable wrenches.
10. Assemble 3/4” NPT x 3/4” hose barb tting [13]
onto drain hose with J-Hook [14] using 1” hose
clamp [11], tighten with at head screwdriver.
Adjustable Wrenches Flat Head Screwdriver 7/16” Wrenches
TOOLS & SUPPLIES NEEDED
Figure 1
Figure 3
Figure 4
Figure 2