4FOR SERVICE ASSISTANCE, CALL 800-433-0708 OR VISIT JOHNDOW.COM
OPERATING INSTRUCTIONS
To Fill:
1. Roll the drain under the vehicle and drain the uid into the drain.
To Empty:
1. Position the drain next to the used oil storage receptacle.
2. Attach the 10’ evacuation hose to the pump outlet side quick connect coupler. Make sure
connection is secure.
3. Place the other end of the evacuation hose securely into the used oil receptacle.
4. Plug the electric pump into a 120V outlet. The pump will self prime and start to pump.
5. Monitor the level in the drain and unplug the pump when the drain is evacuated.
6. When nished, disconnect the evacuation hose and position the end onto the cradle.
Wrap the electrical cord onto the storage cleat.
ASSEMBLY INSTRUCTIONS
1. Assemble M12 at washer [15], nut [16], and hex head screw [14] to wheels [13] using
19mm socket and wrench (Figure 1).
2. Assemble four M10 hex head screws [9], four M10 nuts [12], and eight M10 at washers
[10] per caster [11] using 17mm socket and wrench (Figure 2).
3. Wrap ¾ NPT threads on drain with PTFE tape and assemble ¾ NPT elbow [17]. Tighten
using pipe wrench and position facing upward (Figure 3).
4. Remove eight M6 bolts [22] and pump cover [21] from rear of drain using 10mm wrench
(Figure 4). Mount the pump [23] and reinstall four M6 bolts with 10mm wrench.
5. Wrap ¾ NPT end of the ½ x 6-1/2 inch hose [18] with PTFE tape and thread into ¾ NPT
elbow [17]. Tighten with a 1-1/16 inch wrench (Figure 5).
6. Wrap PTFE tape onto the ½ x 3/8 NPT hose barb tting [20] and thread into the inside of
the pump [23]. Tighten with a 11/16 wrench.
7. Place the hose clamp [19] on the ½ x 6-1/2 hose [18]. Flex the hose to form a 90° arc and
slide the hose end onto the ½ x 3/8 hose barb tting [20] on the pump (Figure 6).
8. Position the hose clamp and tighten with at head screw driver.
9. Wrap PTFE tape onto ½ NPT thread end of the ½ x 5-1/2 inch outlet hose [24] and assem-
ble female quick connector tting.
10. Wrap PTFE tape onto the 3/8 NPT end of the ½ x 5-1/2 inch outlet hose [24] and thread
into pump [23]. Tighten with 11/16 wrench (Figure 7).
11. Reinstall the pump cover [21] using four M6 bolts [22] and tighten with 10mm wrench
(Figure 8).
12. Wrap the electrical cord of pump on the cleat of pump cover.
13. Wrap PTFE on the ½ NPT thread of the ½ x 10’ evacuation hose and assemble to the
male quick connect ttings.
14. Assemble four-piece handle assembly [3, 6 x2, 8] with four M8 washers [4], nuts [7], and
hex head screws [5], using 13mm socket and wrench (Figure 9).
15. Attach handle assembly to tank with two M8 washers [4], nut [7], and hex head screw [5]
using 13mm socket and wrench.
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9