10. METHODS OF CONFIGURING AND SELECTING INSTALLATION
1. Install the unit at the air inlet so
that the air flows smoothly and the
noise is lower.
2. The noise value varies with the
length.
3. The hose joint should be bent lest
detachment of the pipe.
1. Install the unitat a diffuserso
that the air flowssmoothly and the
noise is lower.
2. Select 1BY2 or1BY3 according
to the quantity ofthe diffusers.
3. The diffuserpipes should
preferably have the samelength
after branching, and theminimum
length of the ventilationpipes is 5m.
1. Fixed model thatdiffuses air at
a angle.
2. The outlinesize should increase
when the air volumeis over
&0+ (for above ,i.e.,
when about 9 diffusers are
required, the outline sizeshould
increase.
3. The diffuserpipes should
preferably have the samelength
after branching, and theminimum
length of the ventilationpipes is 5m.
Material name Material name
1
2
3
4
5
6
7
9
12
8
10
11
1. Fixed model that diffuses air ata
36 angle.
2. The outline size should increase
when the air volume is over
35CMH. (for above 33), i.e., When
about 9 diffusers are required, the
outline size should increase.
3. Proper air speed: For airspeed of
over 2-3.5m/s, select other diffusers
(with greater noise).
4. Install the diffuser pipe if it is
necessary to install the model of
over 3.5m/s.
5. For purpose of cooling-only model
1 The lengthwiseadjustable model
which diffuses airat a angle.
2. With the changeof the cooling/
heating air flow,the horizontal and
vertical distance of thefan can be
adjusted (applicable to department
store and exhibition hallwhere the
decorative effect isessential).
1. Low noise comparedwith other
air outlets. Applicableto tall
buildings that require along
distance of air conditioning.
2. Select the ventilationpipe
connection calibre according tothe
distance and the airspeed.
3. Applicable tostorey height of over
5m (for design oftall storeys such
as temple, consult manfacturer).
1. The fan is the adjustable type
which can change direction of air
flow. It isused for deluxe decoration.
2. The outline size should increase
when the air volume is over
45CMH. (3 or4SOLT) When about
6 diffusers are required, theoutline
size should increase.
3. Ifthe proper air speed is 2.5 5m/s
and actual airspeed reaches over
5m/s, it is necessary tochoose other
diffusers (with higher noise values).
1. Low noise comparedwith other
air outlets. Applicableto tall
buildings that require along distance
of air conditioning.
2. Select the ventilationpipe
connection calibre according tothe
distance and the airspeed.
3. Applicable tostorey height of over
5m (for design oftall storeys such
as temple, consult manfacturer).
1. Flanges and pipelinesconnected
to the ventilation pipes.
2. When the noisepipe is connected
with the hose, theventilation pipe
tape must be applied(otherwise,
with only adhesive tape,the
adhesion will be weakeneddue to
change of temperature).
1. It is used to prevent glass wool
leak and seal the gas at the time of
connecting the flanges and
pipelines of the ventilation pipes.
2. Entwine for over 3 circles.
3. Use ventilation pipe-specific
tapes (instead of ordinary adhesive
tapes).
In order to ensure the installation
quality and durability, it is necessary
to use auxiliary materials of standard
specifications provided by
manfacturer Electr
onics and the
auxiliary products of thespecified
manufacturers.
Air inlet wooden grille
Filter
Aluminium adhesive tape
Duct wrapping tape
Air outlet wooden grille
Linear diffuser
Round
Rectangular
1. Install the unit at the air outlet so
that the air flows smoothly and the
noise is lower.
2. The noise value varies with the
length.
3. The hose joint should be bent lest
detachment of the pipe.
14
Installation Manual
Characteristics,advantages
and other contents
Characteristics,advantages
and other contents
1. Install the fillter at the main body
grille in case the storey height is low,
and at the main body of the indoor
unit in case the storey height is high.
2. It cleans conveniently at the
time of installing/uninstalling the
fillter.
3. The button structure is easy to
install and uninstall.
Hose(for absorbing noise)
Hose(for general purpose)
Air inlet noise pipe
Air outlet noise pipe
Distributor
Rectangular air outlet
1. For purpose of air inlet
2. Must adopt fire-resistant materials.
(Those materials other than specified
by manfacturer shall not be applied)
3. The heat insulation material must
be glass wool.
1. For purpose of air outlet
2. Must adopt fire-resistant materials.
(Those materials other than specified
by manfacturer shall not be applied)
3. The heat insulation material must
be glass wool.
Air outlet
Air outlet
Air outlet
Auxiliary materials