DVN 5000 Rackmount Series Server Quick Installation Guide
24-10129-4 Rev. E 7
This document contains confidential and proprietary information of Johnson Controls, Inc.
© 2009 Johnson Controls, Inc.
Uninterruptible Power Supply (UPS)
Johnson Controls strongly recommends providing power to the DVN 5000 unit via a
listed UPS for temporary, backup power in the event of a power failure.
Recommended Manufacturer: APC®
Recommended UPS Minimum Wattage and Volt-Amperes Rating:
500 W (833 VA) each
NOTE
The backup time and therefore battery size varies, depending on the
requirements of the site.
For more information on using a UPS device with the DVN 5000, refer to the
DVN 5000 Series Software Installation and Configuration Manual.
Voltage Selection
The DVN 5000 series server does not have a voltage selection switch. The rating is
100-240 VAC, 50/60 Hz. Verify that this voltage type and range matches the local
power supply value
Non Standard Connectors Rating
The rating of non standard connectors (alarm relays outputs and switched digital
inputs) is maximum 0.5 A at 12 VDC, 24 VAC, or max 42 VDC for all DVN 5000
Series models.
Mounting
If applicable, mount the unit in an appropriate server rack using the rack
manufacturer’s specific mounting hardware or on a fixed shelf.
Refer to the rack manufacturer’s documentation for instructions on the proper
installation of rack-mounted devices, including any weight and spacing
requirements and restrictions. Ideally, if using a server rack, mount any UPS device
at the bottom of the rack followed by the DVN 5000 server(s). For proper
ventilation, leave some space between the units.
!
CAUTION
Do not place the DVN 5000 in a location where the unit’s vents will be
obstructed, as this may cause the unit to overheat.